| [Origin | France |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | Smartchem 200 |
| Product Type | Discrete Flow Analyzer |
| Measurement Speed | 200 samples/hr |
| Sample Capacity | 5 racks × 126 positions |
| Reaction Temperature | 37.2 °C ± 0.1 °C |
| Optical Range | 420–880 nm |
| Absorbance Linearity | 0.001–2.500 AUFS |
| Resolution | 0.0001 Abs |
| Minimum Reaction Volume | 300 µL |
| Pipetting Range | 3–450 µL |
| Dilution Factor | Up to 100× |
| Reagent Positions | 16 (10 refrigerated + 6 ambient) |
| Standard Positions | 10 |
| Diluent Positions | 2 |
| Filter Wheel | 9 optical filters + 1 blank filter |
| Reaction Cuvettes | 60-position rotating disc, semi-reusable, auto-cleaned and QC-verified |
| Compliance | ASTM, ISO, AOAC, US EPA Method 353.2 (NO₃⁻/NO₂⁻), AFNOR, COFRAC, BATF, USEPA] |
| [Origin | Italy |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | Smartchem 300 |
| Pricing | Available Upon Request |
| Analysis Types | End-point, Kinetic, Differential, Dual-wavelength, Fixed-time |
| Reagent Positions | Up to 72 positions with refrigeration (4 movable racks × 16 slots + 8 fixed slots |
| Sample Positions | 4 universal sample carousels (15 positions each for cups or tubes Ø10–16 mm × 40–100 mm H) |
| Throughput | Up to 450 samples/h (with ISE module), 300 samples/h (photometric only) |
| Photometer | Dual-channel, direct-read, 9-position auto-select narrow-band interference filters (340–880 nm), 6 V/10 W halogen lamp, 6 mm pathlength, linear range 0.001–4.200 Abs, resolution 0.0001 Abs |
| Minimum Reaction Volume | 200 µL |
| Sample/Reagent Dispensing | Capacitive microdispenser, 3.0 µL–330 µL (1 µL increment), 37 °C reagent preheating, integrated probe washing, on-board dilution capability |
| Reaction Cuvettes | 80 reusable quartz/glass cuvettes across 4 independent rotating carousels (20 per carousel), automated cleaning with selectable acidic/alkaline/neutral wash solutions, temperature control at 37 °C ± 0.3 °C |
| Nitrate/Nitrite Module | Fully compliant with US EPA Method 353.2 |
| Optional ISE Module | Direct potentiometric measurement of Na⁺, K⁺, Cl⁻, Li⁺ (140 samples/h) |
| Barcode Scanning | Optional reagent and sample tube barcode readers |
| Compliance | ISO, AOAC, BATF, US EPA, AFNOR, COFRAC] |
| Brand | Resonon |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | Resonon Bio-LIF Hyperspectral Fluorescence Imaging System |
| Price Range | USD 1,500–1,500,000 (FOB) |
| Spectral Resolution (FWHM) | 1.9 nm |
| Excitation Wavelength | 532 nm |
| Emission Range | 550–1000 nm |
| Spatial Resolution | 60 µm/pixel |
| Image Dimensions | 1600 × 2065 pixels |
| Spectral Bands per Pixel | 335 |
| Scan Time | 25 s |
| SNR (max) | 255 |
| Weight | 28 kg |
| Dimensions | 50 × 70 × 28 cm |
| Power Supply | 120/240 VAC |
| Operating Temperature | +10 to +35 °C |
| Sample Compatibility | 90 mm Ø Petri dishes or standard 96-well microplates (127 × 86 mm) |
| Brand | Resonon |
|---|---|
| Origin | USA |
| Model | Pika UV |
| Operating Principle | Push-broom |
| Imaging Method | Dispersive |
| Platform Compatibility | Ground-based & Airborne |
| Spectral Range | 350–800 nm |
| Spectral Resolution | 2.3 nm |
| Spatial Channels | 1600 |
| Spectral Channels | 196 |
| Field of View (TFOV) | 29.0° |
| Instantaneous Field of View (IFOV) | ≤1600 × n (n = scan lines) |
| Frame Rate | 165 fps |
| Bit Depth | 12-bit |
| Weight | 2.1 kg |
| Dimensions | 10.0 × 26.4 × 7.4 cm |
| Interface | USB 3.0 |
| Operating Temperature | 5–40 °C |
| Aperture | f/2.4 |
| Pixel Size | 8 µm |
| RMS Spot Radius (avg.) | 8 µm |
| Smile (peak-to-peak) | 4 µm |
| Keystone (peak-to-peak) | 6 µm |
| SNR | >600:1 (typ. @ full well) |
| Stray Light Rejection | <0.05% |
| Distortion | <0.1% radial |
| Brand | YSI |
|---|---|
| Origin | USA |
| Model | YSI 30 |
| Type | Handheld, Battery-Powered, Waterproof Conductivity/Salinity/Temperature Meter |
| Electrode | Four-Pure-Nickel Electrode (Platinum-Black-Free) |
| Calibration | Factory-Calibrated (No Field Calibration Required) |
| Temperature Compensation | Automatic, Adjustable Reference Temperature (e.g., 25°C) and Temperature Coefficient (β) |
| Display | Large Backlit LCD |
| Enclosure Rating | IP67 Submersible |
| Battery Life | Up to 100 hours (Alkaline AA batteries) |
| Cable Options | 3 m, 7.5 m, 15 m |
| Data Logging | None (YSI 30) |
| Compliance | Designed for field-deployable environmental monitoring per ASTM D1125, ISO 7888, and US EPA Method 120.1 |
| Brand | Resonon |
|---|---|
| Origin | USA |
| Model | Pika II |
| Operating Principle | Push-broom |
| Imaging Method | Dispersive |
| Deployment | Ground-based & Airborne |
| Spectral Range | 400–900 nm |
| Spectral Resolution | 2.1 nm |
| Spatial Channels | 640 |
| Spectral Channels | 240 |
| Frame Rate | 145 fps |
| Field of View (TFOV) | 3.9°, 5.5°, 12.0°, 16.0°, 22.5°, 33.0°, or 43.5° (interchangeable optics) |
| Instantaneous Field of View (IFOV) | 0.20, 0.30, 0.65, 0.88, 1.25, 1.9, or 2.5 mrad (optics-dependent) |
| Bit Depth | 12-bit |
| Interface | IEEE 1394b & Gigabit Ethernet |
| Power | 8–30 VDC, <2.5 W |
| Weight | 1.3 kg |
| Dimensions | 124 × 239 × 210 mm |
| Operating Temperature | 0–45 °C |
| Aperture | f/3.0 |
| RMS Spot Radius (avg.) | 7 µm |
| Smile (peak-to-peak) | 5 µm |
| Keystone (peak-to-peak) | 7 µm |
| Brand | LGR |
|---|---|
| Origin | USA |
| Model | 908-0008, 912-0008 |
| Measurement Principle | Off-Axis Integrated Cavity Output Spectroscopy (OA-ICOS) |
| Isotopes Measured | δ²H and δ¹⁸O in liquid water |
| Precision (High-Accuracy Mode, 1σ) | δ²H < 0.3‰, δ¹⁸O < 0.1‰ |
| Precision (High-Throughput Mode, 1σ) | δ²H < 0.6‰, δ¹⁸O < 0.2‰ |
| Sample Volume per Injection | < 1 µL (adjustable) |
| Max. Daily Injections | 1080 |
| Unknown Samples per Day | 150 (high-throughput), 30 (high-accuracy) |
| Salinity Tolerance | < 4% w/w |
| Operating Temperature | 5–45 °C |
| Sample Temperature Range | 0–50 °C |
| Output Interfaces | RS-232, Ethernet, USB |
| Power | 115/230 VAC, 50/60 Hz, 150 W |
| Dimensions | 25.4 cm (H) × 96.5 cm (W) × 35.6 cm (D) |
| Weight | 27 kg |
| Brand | LICA |
|---|---|
| Origin | Beijing, China |
| Model | LR1601 |
| Operating Principle | Push-broom |
| Platform Compatibility | Airborne & Ground-based |
| Spectral Range | 400–1000 nm |
| Spectral Resolution | 2.7 nm |
| Spectral Sampling Interval | 2.1 nm |
| Number of Spectral Bands | 561 (binning option: 281) |
| Spatial Pixels per Line | 1364 |
| Max Frame Rate | 249 fps |
| LiDAR Scan Rate | 320,000 pts/sec |
| Maximum Range | 150 m |
| Horizontal Accuracy | ±2 cm (1σ) |
| Vertical Accuracy | ±1 cm (1σ) |
| IMU Attitude RMS (Pitch/Roll) | 0.04° (PPK-aided) |
| GNSS Support | GPS, GLONASS, BeiDou, RTK |
| System Weight | 2.4 kg |
| Optional Sensors | RGB Camera, Thermal Imaging Camera |
| Brand | NC Technologies |
|---|---|
| Origin | Italy |
| Model | ECS 8024 Soil-Specific CN Elemental Analyzer |
| Measurement Principle | Dumas combustion coupled with gas chromatographic separation |
| Detection | High-resolution thermal conductivity detector (TCD) |
| Sample Throughput | Up to 147 positions (pneumatic/electronic/manual samplers) |
| Analysis Time | ~5 min per CN determination |
| Quantification Range | 0.002–20 mg C and N per sample |
| Accuracy | <0.2% RSD (relative standard deviation) |
| Precision | <0.1% RSD |
| Dual-Furnace System | Left & right furnaces, up to 1100 °C each |
| Separation Oven Temperature | Up to 110 °C |
| Carrier Gas | Helium |
| Oxidant | Automated oxygen dosing |
| GC Column | 3 m packed capillary column |
| Software | EAS Clarity™ with linear/quad/cubic calibration, active recalibration, audit trail, and GLP-compliant data handling |
| Compliance | Designed for ASTM D5373, ISO 13878, USP <281>, and EN 15936 workflows |
| Brand | NC Technologies |
|---|---|
| Origin | Italy |
| Model | ECS 8040 CHNS-O Organic Elemental Analyzer |
| Measurement Principle | Dumas combustion coupled with gas chromatographic separation and thermal conductivity detection (TCD) |
| Elemental Range | C, H, N, S, O (0.002–20 mg for C/H/N |
| Accuracy | <0.2% (certified reference materials, purity >99.9%) |
| Precision | <0.1% RSD (certified reference materials, purity >99.9%) |
| Combustion Temperature | up to 1100 °C |
| Reduction Oven Temperature | up to 110 °C |
| Carrier Gas | Helium |
| Oxygen Delivery | Automated dosing with electronic flow control |
| GC Column | 0.8–4 m capillary or packed GC column (dedicated for CO₂, H₂O, N₂, SO₂ separation) |
| Detector | High-sensitivity, reference-free TCD |
| Sample Throughput | Up to 147 positions (pneumatic autosampler), 32/50/100 positions (electronic autosampler), manual option available |
| User Interface | Integrated touchscreen display |
| Software | EAS Clarity™ with linear/quadratic/cubic calibration, active recalibration, audit trail, and GLP-compliant data handling |
| Power Management | Standby mode for reduced He/O₂ consumption and energy use |
| Compliance | Designed to support ASTM D5291, ISO 16968, USP <28>, and FDA 21 CFR Part 11 requirements (when configured with full audit trail and electronic signature modules) |
| Brand | Resonon |
|---|---|
| Origin | USA |
| Model | Pika IR |
| Instrument Type | Online Hyperspectral Imager |
| Principle | Push-broom Imaging Spectroscopy |
| Spectral Range | 900–1700 nm |
| Spectral Resolution | 4.9 nm |
| Spectral Bands | 164 |
| Spatial Pixels per Line | 320 |
| Max Frame Rate | 520 fps |
| Bit Depth | 14-bit |
| Weight | 2.7 kg |
| Dimensions (L×W×H) | 11.0 × 29.6 × 8.9 cm |
| Interface | Gigabit Ethernet |
| Operating Temperature | 5–40 °C |
| Aperture | f/1.8 |
| Pixel Size | 30 µm |
| Average RMS Spot Radius | 10 µm |
| Smile (Peak-to-Peak) | 10 µm |
| Keystone (Peak-to-Peak) | 10 µm |
| Radiometric Calibration | Included |
| Pre-installed Software | SpectrononPro, Resonon Acquisition & Analysis Suite |
| Brand | SciAps |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Z-903 |
| Instrument Type | Handheld |
| Integration | Fully Integrated |
| Spectral Range | 190–950 nm |
| Detection Capability | H to U (All Elements) |
| Weight | 1.97 kg (4.35 lb) |
| Dimensions | 273 × 73 × 219 mm (10.75 × 2.875 × 8.625 in) |
| Operating System | Android™ (ARM Quad-Core Cortex-A53, 1.2 GHz) |
| Memory | 2 GB LPDDR3 RAM + 16 GB eMMC internal storage |
| Data Storage | 32 GB microSD card |
| Display | 3.5-inch high-brightness color touchscreen (rear-mounted) |
| Laser Class | Class 3B |
| Safety Compliance | CE, RoHS, US FDA Registered |
| Environmental Control | Integrated Opti-Purge™ argon purge system |
| Calibration Reference | Onboard 316 stainless steel validation standard |
| Grade Libraries | >500 preloaded alloy/geochemical libraries, user-editable and multi-library support |
| Connectivity | Wi-Fi (802.11b/g/n), Bluetooth BR/EDR + BLE, GPS, USB-C |
| Power | Rechargeable Li-ion battery (internal & external charging), AC adapter compatible |
| Sample Alignment | Integrated coaxial laser targeting + dual-camera system (wide-field + macro) |
| Drift Correction | Onboard auto-drift correction using factory or user-defined reference materials |
| Software | SciAps AnalyzAR™ suite with spectral comparison, quantitative calibration curve generation, and full parameter control (laser firing pattern, spectrometer integration time, lens cleaning protocol) |
| Brand | LGR |
|---|---|
| Origin | USA |
| Model | CCIA/WVIA |
| Measurement Principle | Off-Axis Integrated Cavity Output Spectroscopy (OA-ICOS) |
| Isotopic Ratios | δ¹³C/δ¹⁸O (CO₂), δ²H/δ¹⁷O/δ¹⁸O (H₂O) |
| Precision (1σ) | δ¹³C ≤ 0.1‰ (5 min), δ¹⁸O ≤ 1‰ (5 min), δ²H ≤ 0.2‰ (100 s), δ¹⁷O ≤ 0.05‰ (100 s) |
| Measurement Frequency | Up to 2 Hz (WVIA), 1 Hz (CCIA) |
| Effective Optical Path | >2 km |
| Operating Temperature | 0–45 °C |
| Sample Temp Range | −20 to +50 °C |
| Pressure Control Accuracy | ±0.001 torr |
| Temperature Control Accuracy | ±0.003 °C |
| Data Interfaces | RS-232, Ethernet, USB |
| Power | 115/230 VAC, 50/60 Hz, 550 W max |
| Brand | NC Technologies |
|---|---|
| Origin | Italy |
| Model | ECS 4024 Classic CHNS-O Elemental Analyzer |
| Detection Principle | Flash Combustion coupled with Gas Chromatographic Separation |
| Elements Analyzed | C, H, N, S, O |
| Detection Range | 200 ppm – 100% |
| Sample Mass | 0.01–100 mg (matrix-dependent) |
| Accuracy | < 0.2% (vs. certified reference materials) |
| Precision | < 0.1% RSD (vs. certified reference materials) |
| Combustion Furnace Temperature | 800–1100 °C |
| GC Column Temperature Range | 30–110 °C |
| TCD Limit of Quantification | 1–5 µg |
| Analysis Time | 15 min (CHNS), 3 min (CN, using 2-m GC column) |
| Auto-samplers | Pneumatic (up to 147 positions), Electronic (32/50/100 positions), Manual |
| Software | EAS CLARITY for Windows |
| Gas Requirements | He (99.999%, 3–5 bar), O₂ (99.999%, 3–5 bar), Oil-free dry compressed air |
| Dimensions | 760 × 350 × 700 mm (L×W×H) |
| Power Supply | 230 VAC ±10%, 1–10 A |
| Brand | Picarro |
|---|---|
| Origin | USA |
| Model | G2210-i |
| Instrument Type | Cavity Ring-Down Spectroscopy (CRDS)-Based Stable Isotope Analyzer |
| Measurement Targets | δ¹³CH₄, CH₄, C₂H₆, CO₂, H₂O |
| Precision (1σ, 5-min avg) | δ¹³CH₄: 0.5–1.0 ‰ |
| CH₄ | <0.1 ppb |
| C₂H₆ | <1 ppb |
| CO₂ | <200 ppb |
| Dynamic Range | CH₄: 2–30 ppm |
| C₂H₆ | 0–100 ppm |
| CO₂ | 300–2000 ppm |
| Measurement Frequency | up to 1.5 Hz |
| Sample Flow | ~40 sccm |
| Cavity Volume | 35 mL |
| Temperature Control Stability | ±0.005 °C |
| Pressure Control Stability | ±0.0002 atm |
| Operating Ambient | 15–35 °C |
| Power | 100–240 VAC, 47–63 Hz, <375 W peak |
| Brand | Resonon |
|---|---|
| Origin | USA |
| Model | Pika IR+ |
| Instrument Type | Online Hyperspectral Imager |
| Principle | Push-broom Imaging Spectroscopy |
| Spectral Range | 900–1700 nm |
| Spectral Resolution | 2.5 nm |
| Spectral Bands | 328 |
| Spatial Pixels | 640 |
| Max Frame Rate | 249 fps |
| Data Bit Depth | 14-bit |
| Weight | 2.7 kg |
| Dimensions (L×W×H) | 11.0 × 29.6 × 8.9 cm |
| Interface | GigE Vision |
| Operating Temperature | 5–40 °C |
| Aperture | f/1.8 |
| Pixel Size | 15 µm |
| RMS Spot Radius (avg.) | 10 µm |
| Smile (peak-to-peak) | 10 µm |
| Keystone (peak-to-peak) | 10 µm |
| Radiometric Calibration | Included |
| Pre-installed Software | SpectrononPro, Resonon Acquisition & Analysis Suite |
| Brand | Resonon |
|---|---|
| Origin | USA |
| Model | Pika NIR |
| Operating Principle | Push-broom |
| Imaging Method | Dispersive |
| Platform Compatibility | Ground-based & Airborne |
| Spectral Range | 900–1700 nm |
| Spectral Resolution | 4.9 nm |
| Spatial Channels | 3200 |
| Field of View (TFOV) | 7.3°, 11°, 22°, or 90° (selectable) |
| Instantaneous Field of View (IFOV) | 0.4, 0.6, 1.2, or 6.3 mrad |
| Frame Rate | 520 fps |
| Spectral Bands | 164 |
| Bit Depth | 14-bit |
| Interface | GigE Vision |
| Weight | 2.7 kg |
| Dimensions | 11.0 × 29.6 × 8.9 cm |
| Operating Temperature | 5–40 °C |
| Aperture | f/1.8 |
| RMS Spot Radius (avg.) | 10 µm |
| Smile (peak-to-peak) | 10 µm |
| Keystone (peak-to-peak) | 10 µm |
| Brand | NC Technologies |
|---|---|
| Origin | Italy |
| Model | ECS 8020 CHNS-O Organic Elemental Analyzer |
| Measurement Principle | Dumas combustion coupled with gas chromatographic separation and thermal conductivity detection (TCD) |
| Elemental Modes | CHNS, CHN, CN, CNS, O |
| Sample Types | Solid and liquid |
| Sample Weight Range | C/H/N/S: 0.002–20 mg |
| O | 0.002–2 mg |
| Analysis Time | CHN: 5 min |
| CHNS | 10–25 min |
| O | 4 min |
| Accuracy | <0.2% (certified reference materials, purity >99.9%) |
| Precision (RSD) | <0.1% |
| Dual Combustion Furnaces | Max. 1100 °C each |
| Separation Oven Temp. | Up to 110 °C |
| Carrier Gas | Helium |
| Oxygen Delivery | Integrated mass-flow controlled O₂ dosing |
| GC Column Length | 0.8–4 m |
| Detector | High-sensitivity TCD, reference-gas-free operation |
| Autosamplers | Pneumatic (147 positions), electronic (32/50/100 positions), manual |
| Software | EAS Clarity v.x.x with linear/quadratic/cubic calibration, active recalibration, audit trail, GLP-compliant data handling |
| Compliance | Designed for ISO 17025, ASTM D5291, ASTM D7622, USP <28>, EN 15407, and FDA 21 CFR Part 11-ready configurations |
| Origin | Italy |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Smartchem 300 |
| Pricing | Upon Request |
| Brand | Picarro |
|---|---|
| Origin | USA |
| Model | L2130-i |
| Instrument Type | Cavity Ring-Down Spectroscopy (CRDS) Isotope Ratio Analyzer |
| Measurement Targets | δ¹⁸O and δD in H₂O |
| Precision (1σ, liquid water) | δ¹⁸O ≤ 0.025‰, δD ≤ 0.100‰ |
| 24-h Drift (liquid) | δ¹⁸O ≤ 0.200‰, δD ≤ 0.800‰ |
| Water Vapor Range | 1,000–50,000 ppm |
| Detection Technique | Off-axis Integrated Cavity Output Spectroscopy (OA-ICOS) |
| Operating Temperature | 10–35°C (liquid analysis), –10 to 45°C (vapor analysis) |
| Dimensions | 43.2 × 19.1 × 43.2 cm (W × H × D) |
| Weight | 20.4 kg |
| Power | 90–240 VAC, 50/60 Hz, <150 W (analyzer), +80 W (external pump) |
| Software | Pre-installed Picarro Analysis Suite on Windows 10 Pro |
| Brand | Resonon |
|---|---|
| Origin | USA |
| Model | Pika XC |
| Operating Principle | Push-broom |
| Imaging Method | Dispersive |
| Platform Compatibility | Ground-based & Airborne |
| Spectral Range | 400–1000 nm |
| Spectral Resolution | 2.4 nm |
| Spatial Pixels | 1384 |
| Frame Rate | 240 fps |
| Field of View (TFOV) | 7.2°, 10.0°, 21.5°, 29.0°, 40.0°, 57.5°, or 72.0° (selectable) |
| Instantaneous Field of View (IFOV) | 0.36, 0.5, 1.1, 1.5, 2.1, 3.1, or 4.2 mrad (selectable) |
| Bit Depth | 14-bit |
| Power Requirement | 8–30 VDC, <2.5 W |
| Weight | 1.9 kg |
| Dimensions | 12.4 × 23.9 × 21.0 cm |
| Operating Temperature | 0–45 °C |
| f-number | f/2.4 |
| RMS Spot Radius (avg.) | 6 µm |
| Smile (peak-to-peak) | 2 µm |
| Keystone (peak-to-peak) | 6 µm |
| Interface | IEEE 1394b |
| Brand | NC Technologies |
|---|---|
| Origin | Italy |
| Model | ECS 4010 Classic CHNS-O Elemental Analyzer |
| Detection Principle | Flash Combustion coupled with Gas Chromatographic Separation |
| Elements Analyzed | C, H, N, S, O |
| Detection Range | 200 ppm – 100% |
| Sample Mass | 0.01–100 mg (matrix-dependent) |
| Accuracy | < 0.2% (vs. certified reference materials) |
| Precision | < 0.1% RSD (vs. certified reference materials) |
| Column Temperature Control | 30–110 °C (user-programmable) |
| Oxidation Reactor Temp | 800–1100 °C |
| Reduction Reactor Temp | 600–1100 °C |
| Analysis Time | ~15 min (CHNS), ~3 min (CN only, 2-m column) |
| Detector | Thermal Conductivity Detector (TCD) |
| LOQ | 1–5 µg |
| Auto-samplers | Pneumatic (up to 147 positions), Electronic (32/50/100 positions), Manual |
| Software | EAS CLARITY v.x.x (Windows OS) |
| Gas Requirements | He (99.999%, 3–5 bar), O₂ (99.999%, 3–5 bar), Oil-free Dry Compressed Air |
| Dimensions | 760 × 350 × 700 mm (L×W×H) |
| Power | 230 VAC ±10%, 1–10 A |
| Brand | Picarro |
|---|---|
| Origin | USA |
| Model | G2301 |
| Measurement Principle | Cavity Ring-Down Spectroscopy (CRDS) |
| Simultaneous Target Gases | CO₂, CH₄, H₂O |
| Detection Sensitivity | <0.5 ppb (CH₄), <70 ppb (CO₂), <80 ppm (H₂O) |
| Precision (1σ, 5 s) | CO₂ <70 ppb, CH₄ <0.5 ppb, H₂O <80 ppm |
| Precision (1σ, 5 min) | CO₂ <25 ppb, CH₄ <0.22 ppb, H₂O <30 ppm |
| Max Drift (24 h, STP) | CO₂ <120 ppb, CH₄ <1 ppb, H₂O <100 ppm |
| Water Vapor Correction | Automatic dry-mole-fraction reporting |
| Operating Pressure Range | 300–1000 Torr (40–133 kPa) |
| Sample Flow Rate | <0.4 SLM at 760 Torr |
| Temperature Control Stability | ±0.005 °C (cavity) |
| Pressure Control Stability | ±0.0002 atm (cavity) |
| Sample Temp. Range | −10 to +45 °C |
| Ambient Temp. Range (operational) | 10 to 35 °C |
| Data Interfaces | RS-232, Ethernet, USB, analog (0–10 V optional) |
| Dimensions (Analyzer) | 43.2 × 17.8 × 44.5 cm (W×H×D) |
| Weight | 26.9 kg (incl. external pump) |
| Power | 100–240 VAC, 47–63 Hz, <375 W peak |
| Brand | Resonon |
|---|---|
| Origin | USA |
| Model | Pika XC2 |
| Operating Principle | Push-broom |
| Imaging Method | Dispersive |
| Platform Compatibility | Ground-based & Airborne |
| Spectral Range | 400–1000 nm |
| Spectral Resolution | 1.3 nm |
| Spatial Resolution (IFOV) | 0.36–1.1 mrad (configurable) |
| Field of View (TFOV) | 7.2°, 10.0°, or 21.5° (interchangeable optics) |
| Maximum Frame Rate | 171 fps |
| Spatial Pixels per Line | 1600 |
| Spectral Bands | 447 |
| Bit Depth | 12-bit |
| Weight | 2.2 kg |
| Dimensions | 10.1 × 27.5 × 7.4 cm |
| Aperture | f/2.4 |
| Pixel Size | 5.86 µm |
| RMS Spot Radius (avg.) | 6 µm |
| Smile (peak-to-peak) | 4 µm |
| Keystone (peak-to-peak) | 5 µm |
| Interface | USB 3.0 |
| Operating Temperature | 5–40 °C |
| Software Support | Native Windows & Linux drivers |