Empowering Scientific Discovery

Beijing Meijiatu Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandInstec
OriginUSA
ModelHCS622G
Temperature Range−190 °C to +600 °C (optional up to +700 °C)
Temperature Resolution0.1 °C
Temperature Stability±0.01 °C at 100 °C
Max. Heating Rate230 °C/min at 200 °C
Max. Cooling Rate−130 °C/min at 200 °C
Min. Ramp Rate±0.1 °C/hour
Control MethodSwitching PID (LVDC PID optional)
Sensor100 Ω Platinum RTD
Working Distance5.8 mm
Condenser Distance12.7 mm
Sample Area38 mm × 38 mm
Chamber Height0.76 mm (with inner cover)
Viewing Aperture26.5 mm (reflected light), 2.0 mm (transmitted light)
Vacuum Port1/8″ NPT female
Gauge Port1/8″ NPT female
Added to wishlistRemoved from wishlist 0
Add to compare
BrandInstec
OriginUSA
ModelHCS410
Temperature Range–60 °C to 400 °C
Temp. Resolution0.01 °C
Temp. Stability±0.02 °C at 100 °C
Max. Heating Rate+50 °C/min
Max. Cooling Rate–50 °C/min
Control MethodSwitching PID (LVDC PID optional)
Sensor100 Ω Platinum RTD
Sample Area38 mm × 50 mm
Chamber Height2.0 mm / 6.0 mm (w/ spacers)
Viewing Aperture5 mm
Working Distance6.5 mm
Condenser Distance13 mm
X-Y Micropositioner (optional)10 µm resolution
Added to wishlistRemoved from wishlist 0
Add to compare
BrandInstec
OriginUSA
ModelTSA02i
Temperature Range–25°C to +60°C (optional extended range available)
Temperature Resolution±0.01°C at 37°C
Temperature Stability±0.1°C/hour
Max Heating Rate+50°C/min at 37°C
Max Cooling Rate–50°C/min at 37°C
Sample Area53 mm × 78 mm
Viewing Aperture17 mm (with sample plate), 40 mm (without sample plate)
Working Distance1.3 mm (standard), 2.8 mm (with sample plate), 14.6 mm (inner cover only)
Chamber Height12.8 mm (inner cover), 32 mm (outer cover)
Condenser Clearance35 mm (with outer cover), 14.6 mm (inner cover only)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandInstec
OriginUSA
ModelHCS602
Temperature Range–190 °C to +600 °C (optional up to +700 °C)
Temperature Stability±0.1 °C at 100 °C
Minimum Temperature Resolution0.01 °C
Max Heating Rate+200 °C/min at 100 °C
Max Cooling Rate–130 °C/min at 100 °C (with LN2-P4 accessory)
Sample Area35 mm × 35 mm
Standard Optical Window20 mm × 20 mm
Optional Large Optical Window38 mm × 38 mm
Minimum Working DistanceObjective ≥ 5.3 mm, Condenser ≥ 10.0 mm
ControllerSTC200 standalone unit with RS232 interface and Windows software
Software SupportLabVIEW drivers (IEEE-488 & RS232) included
ComplianceDesigned for ASTM E2267, ISO 11357, and USP <1031> thermal microscopy applications