| Brand | Instec |
|---|---|
| Origin | USA |
| Model | HCS622G |
| Temperature Range | −190 °C to +600 °C (optional up to +700 °C) |
| Temperature Resolution | 0.1 °C |
| Temperature Stability | ±0.01 °C at 100 °C |
| Max. Heating Rate | 230 °C/min at 200 °C |
| Max. Cooling Rate | −130 °C/min at 200 °C |
| Min. Ramp Rate | ±0.1 °C/hour |
| Control Method | Switching PID (LVDC PID optional) |
| Sensor | 100 Ω Platinum RTD |
| Working Distance | 5.8 mm |
| Condenser Distance | 12.7 mm |
| Sample Area | 38 mm × 38 mm |
| Chamber Height | 0.76 mm (with inner cover) |
| Viewing Aperture | 26.5 mm (reflected light), 2.0 mm (transmitted light) |
| Vacuum Port | 1/8″ NPT female |
| Gauge Port | 1/8″ NPT female |
| Brand | Instec |
|---|---|
| Origin | USA |
| Model | HCS410 |
| Temperature Range | –60 °C to 400 °C |
| Temp. Resolution | 0.01 °C |
| Temp. Stability | ±0.02 °C at 100 °C |
| Max. Heating Rate | +50 °C/min |
| Max. Cooling Rate | –50 °C/min |
| Control Method | Switching PID (LVDC PID optional) |
| Sensor | 100 Ω Platinum RTD |
| Sample Area | 38 mm × 50 mm |
| Chamber Height | 2.0 mm / 6.0 mm (w/ spacers) |
| Viewing Aperture | 5 mm |
| Working Distance | 6.5 mm |
| Condenser Distance | 13 mm |
| X-Y Micropositioner (optional) | 10 µm resolution |
| Brand | Instec |
|---|---|
| Origin | USA |
| Model | TSA02i |
| Temperature Range | –25°C to +60°C (optional extended range available) |
| Temperature Resolution | ±0.01°C at 37°C |
| Temperature Stability | ±0.1°C/hour |
| Max Heating Rate | +50°C/min at 37°C |
| Max Cooling Rate | –50°C/min at 37°C |
| Sample Area | 53 mm × 78 mm |
| Viewing Aperture | 17 mm (with sample plate), 40 mm (without sample plate) |
| Working Distance | 1.3 mm (standard), 2.8 mm (with sample plate), 14.6 mm (inner cover only) |
| Chamber Height | 12.8 mm (inner cover), 32 mm (outer cover) |
| Condenser Clearance | 35 mm (with outer cover), 14.6 mm (inner cover only) |
| Brand | Instec |
|---|---|
| Origin | USA |
| Model | HCS602 |
| Temperature Range | –190 °C to +600 °C (optional up to +700 °C) |
| Temperature Stability | ±0.1 °C at 100 °C |
| Minimum Temperature Resolution | 0.01 °C |
| Max Heating Rate | +200 °C/min at 100 °C |
| Max Cooling Rate | –130 °C/min at 100 °C (with LN2-P4 accessory) |
| Sample Area | 35 mm × 35 mm |
| Standard Optical Window | 20 mm × 20 mm |
| Optional Large Optical Window | 38 mm × 38 mm |
| Minimum Working Distance | Objective ≥ 5.3 mm, Condenser ≥ 10.0 mm |
| Controller | STC200 standalone unit with RS232 interface and Windows software |
| Software Support | LabVIEW drivers (IEEE-488 & RS232) included |
| Compliance | Designed for ASTM E2267, ISO 11357, and USP <1031> thermal microscopy applications |