BioCool
Filter
Showing 61–90 of 113 results
| Brand | BIOCOOL |
|---|---|
| Origin | Beijing, China |
| Model | LYO-5E |
| Instrument Type | Standard Shelf-Type Freeze Dryer |
| Application Scope | Production-Scale |
| Lyophilization Area | 5 m² |
| Ultimate Vacuum | <4 Pa |
| Condensate Capacity (24 h) | 100 kg/24 h |
| Cold Trap Temperature (No-Load) | <−75 °C |
| Shelf Temperature Range (No-Load) | −55 °C to +110 °C |
| Shelf Quantity | 6+1 |
| Shelf Spacing | 100 mm |
| Maximum Vial Capacity (Ø22 mm) | 9,450 units |
| Wall-Penetration Isolation | Yes |
| Stoppering | Not equipped (S-variant required) |
| Compliance | Designed for GLP-compliant operation |
| Brand | BIOCOOL |
|---|---|
| Origin | Beijing, China |
| Model | LYO-5SE |
| Instrument Type | Shelf-Type Freeze Dryer |
| Application | Production-Scale Lyophilization |
| Freeze-Drying Area | 5 m² |
| Ultimate Vacuum | <4 Pa |
| Condensate Capacity (24 h) | 100 kg/24 h |
| Cold Trap Temperature (No-Load) | <−75 °C |
| Shelf Temperature Range | −55 °C to +110 °C |
| Shelf Count | 6+1 |
| Shelf Spacing | 100 mm |
| Control Interface | Industrial Touchscreen (HMI), Programmable Logic Controller (PLC) Based |
| Data Logging Frequency | 50 ms |
| Stored Protocols | Up to 2000 User-Defined or Predefined Lyo Cycles |
| Remote Monitoring Distance (Optional) | Up to 1.5 km |
| Calibration Capability | Temperature & Vacuum Sensors |
| Optional Accessories | Eutectic Point Tester, Dry Vacuum Pump, Cascade Compressor Unit, Extended Vacuum Pump Array, Organic Solvent Trap, Vacuum Oil Mist Filter |
| Brand | BIOCOOL |
|---|---|
| Origin | Beijing, China |
| Model | LYO-7 |
| Instrument Type | Standard Shelf-Type Freeze Dryer |
| Application Scope | Production-Scale |
| Lyophilization Area | 7 m² |
| Ultimate Vacuum | <4 Pa |
| Condensate Capacity (24 h) | 150 kg/24 h |
| Cold Trap Temperature | <−75 °C |
| Brand | BIOCOOL |
|---|---|
| Origin | Beijing, China |
| Model | LYO-7E |
| Instrument Type | Standard Shelf-Type Freeze Dryer |
| Application Scope | Production-Scale |
| Lyophilization Area | 7.5 m² |
| Ultimate Vacuum | <4 Pa |
| Condensate Capacity (24 h) | 150 kg/24 h |
| Cold Trap Temperature | <−75 °C |
| Shelf Temperature Range | −55 °C to +110 °C |
| Shelf Count | 7+1 |
| Shelf Spacing | 100 mm |
| Vial Capacity (Ø22 mm) | 15,750 units |
| Wall-Penetrating Isolation | Yes |
| Stoppering | Not equipped |
| Compliance | Designed for GLP-aligned production environments |
| Brand | BIOCOOL |
|---|---|
| Origin | Beijing, China |
| Model | LYO-7SE |
| Instrument Type | Shelf-Type Freeze Dryer |
| Application | Production-Scale Lyophilization |
| Freeze-Drying Area | 7.5 m² |
| Ultimate Vacuum | <4 Pa |
| Condenser Capacity (24 h) | 150 kg/24h |
| Condenser Temperature (No-Load) | <−75 °C |
| Shelf Temperature Range | −55 °C to +110 °C |
| Shelf Configuration | 7+1 shelves |
| Shelf Spacing | 100 mm |
| Programmable Recipes | 2000 |
| Data Acquisition Rate | 50 ms |
| Touchscreen Interface | Industrial HMI Panel |
| Optional Features | Eutectic Point Tester, Dry Vacuum Pump, Cascade Compressor System, Solvent Trap, Vacuum Oil Mist Filter, Remote Monitoring (up to 1.5 km) |
| Brand | BIOCOOL |
|---|---|
| Origin | Beijing, China |
| Model | LYO-F Series |
| Instrument Type | Standard Shelf-Type Freeze Dryer |
| Application Scope | Production-Scale |
| Lyophilization Area | 400 m² |
| Ultimate Vacuum | 4 Pa |
| Condensate Capacity (24 h) | 8,000 L |
| Cold Trap Temperature | −75 °C |
| Brand | BIOCOOL |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | Pilot Serials OEM |
| Instrument Type | Shelf-Type Freeze Dryer |
| Application Scope | Pilot-Scale |
| Lyophilization Area | 0.1–1 m² |
| Ultimate Vacuum | <3 Pa |
| Condensate Capacity (24 h) | 6 L/24 h |
| Cold Trap Temperature | <−100 °C |
| Shelf Temperature Range (Customizable) | −60 to −100 °C |
| Cold Trap Temperature Range (Customizable) | −100 to −130 °C |
| CIP/SIP Integration | Available for 0.1–1 m² silicone oil-based units |
| Nitrogen Purge & Organic Solvent Compatibility | Optional |
| Dual-Redundant Systems | Refrigeration, Vacuum, Circulation, and Electrical Subsystems |
| Control System | Industrial PLC + HMI Touchscreen |
| Shelf Temperature Uniformity | ±0.1 °C (per shelf area) |
| Eutectic Point Detection | AC Excitation (1 kHz), NI Hardware + Proprietary Algorithmic Analysis |
| In-Line Moisture Monitoring | Gravimetric Method |
| Brand | BIOCOOL |
|---|---|
| Origin | Beijing, China |
| Model | Pilot1-2LD |
| Type | Shelf-Type Freeze Dryer |
| Application | Pilot-Scale Processing |
| Lyophilization Area | 0.1 m² |
| Ultimate Vacuum | <9 Pa |
| Condensate Capacity (24 h) | 2 L/24 h |
| Cold Trap Temperature | −55 °C |
| Compressor | International Brand |
| Vacuum Pump | Korean Brand |
| Control Interface | Industrial Touchscreen |
| Programmable Logic Control | Yes |
| Optional Features | Nitrogen Backfilling, Vacuum Regulation, Endpoint Detection, Non-Electric Defrost, Pulse Backfill, Auto Drain Interlock, Multi-Mode Data Logging |
| Brand | BIOCOOL |
|---|---|
| Origin | Beijing, China |
| Model | Pilot1-2MD |
| Type | Shelf-Type Freeze Dryer |
| Application | Pilot-Scale Processing |
| Lyophilization Area | 0.1 m² |
| Ultimate Vacuum | <7 Pa |
| Condensate Capacity (24 h) | 2 L/24h |
| Cold Trap Temperature (No Load) | <−55 °C |
| Compressor | Imported High-Efficiency Unit |
| Vacuum Pump | Imported High-Speed Rotary Vane Pump |
| Control System | Industrial Touchscreen with Programmable Logic Controller (PLC) |
| Temperature & Vacuum Monitoring Frequency | 50 ms/sample |
| Process Recipe Storage | 500 user-defined protocols |
| Data Logging Options | Internal memory (3-month retention), USB flash drive (optional), PC database (optional) |
| Safety Features | Overcurrent protection, overload protection, 36 V safe-voltage heating circuit, overtemperature cutoff, vacuum interlock, pump anti-backflow device |
| Warranty | 18 months (excl. vacuum pump) |
| Brand | BIOCOOL |
|---|---|
| Origin | Beijing, China |
| Model | Pilot10-15L |
| Type | Standard Shelf-Type Freeze Dryer |
| Application | Pilot-Scale Production |
| Lyophilization Area | 1.0 m² |
| Ultimate Vacuum | ≤3 Pa |
| Condensation Capacity | 15 L/24h |
| Cold Trap Temperature | <−55 °C |
| Brand | BIOCOOL |
|---|---|
| Origin | Beijing, China |
| Model | Pilot10-15M |
| Type | Standard Shelf-Type Freeze Dryer |
| Application | Pilot-Scale Processing |
| Lyophilization Area | 1.0 m² |
| Ultimate Vacuum | ≤3 Pa |
| Condensate Capacity (24 h) | 15 L/24 h |
| Cold Trap Temperature | <−85 °C |
| Shelf Temperature Range (Empty) | −40 to +60 °C |
| Shelf Cooling Method | Silicone Oil Circulation |
| Shelf Spacing | 85 mm |
| Compressor Power | 3 HP (Dual) |
| Vacuum Pump Speed | 4 L/s |
| Safety Features | Overcurrent Protection, Overload Protection, Shelf Overtemperature Protection, Vacuum Process Interlock, Vacuum Pump Backflow Prevention |
| Brand | BIOCOOL |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | Pilot10-15S |
| Instrument Type | Shelf-Type Freeze Dryer |
| Application Scope | Pilot-Scale Production |
| Lyophilization Area | 0.525 m² |
| Ultimate Vacuum | <10 Pa |
| Condensate Capacity (24 h) | 8 L/24 h |
| Cold Trap Temperature | −55 °C |
| Brand | BIOCOOL |
|---|---|
| Origin | Beijing, China |
| Model | Pilot10-15T |
| Type | Standard Shelf-Type Freeze Dryer |
| Application | Pilot-Scale Lyophilization |
| Shelf Area | 1 m² |
| Ultimate Vacuum | ≤ 2.5 Pa |
| Condenser Capacity | 15 kg/24h |
| Condenser Temperature | ≤ −80 °C |
| Shelf Temperature Range | ≤ −50 °C (empty) |
| Shelf Dimensions | 350 mm × 600 mm |
| Number of Shelves | 5 + 1 Radiant Shelf |
| Shelf Spacing | 70 mm |
| Installed Power | 8 kW (3-phase) |
| Unit Dimensions (W×D×H) | ≈ 880 × 2200 × 1900 mm |
| Weight | ≈ 1200 kg |
| Noise Level | ≤ 70 dB(A) |
| Compliance | GMP, GB/T 5226.1–1996 |
| Brand | BIOCOOL |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Pilot10-15T |
| Instrument Type | Shelf-Type Freeze Dryer |
| Application Scale | Pilot-Scale |
| Lyophilization Area | 1 m² |
| Ultimate Vacuum | ≤ 2.5 Pa |
| Condensate Capacity (24 h) | 15 kg/24 h |
| Cold Trap Temperature | ≤ −80 °C |
| Shelf Temperature Range (Empty Load) | ≤ −50 °C |
| Shelf Dimensions | 350 mm × 600 mm |
| Number of Shelves | 5 + 1 Radiant Shelf |
| Shelf Spacing | 70 mm |
| Installed Power | 8 kW (3-Phase) |
| Cooling Method | Air-Cooled (Required Heat Dissipation Area: 8 m²) |
| Overall Dimensions (W×D×H) | ≈ 880 × 2200 × 1900 mm |
| Net Weight | ≈ 1200 kg |
| Sound Pressure Level | ≤ 70 dB(A) |
| Compliance Standards | GMP Guidelines, GMP Implementation Manual for Pharmaceutical Production, GB/T 5226.1–1996 |
| Brand | BIOCOOL |
|---|---|
| Origin | Beijing, China |
| Model | Pilot10-15T |
| Type | Shelf-Type Pilot Freeze Dryer |
| Application | Pilot-Scale Lyophilization |
| Shelf Area | 1 m² |
| Ultimate Vacuum | ≤ 2.5 Pa |
| Condenser Capacity (24 h) | 15 kg/24h |
| Condenser Temperature | ≤ −80 °C |
| Shelf Temperature Range | ≤ −50 °C to +80 °C (empty) |
| Shelf Dimensions | 350 mm × 600 mm |
| Number of Shelves | 5 + 1 Radiant Shelf |
| Shelf Spacing | 70 mm |
| Installed Power | 8 kW (3-phase) |
| Unit Dimensions (W×D×H) | ~880 × 2200 × 1900 mm |
| Weight | ~1200 kg |
| Noise Level | ≤ 70 dB(A) |
| Compliance | GMP, GB/T 5226.1–1996, WHO TRS No. 986 Annex 3 |
| Brand | BIOCOOL |
|---|---|
| Origin | Beijing, China |
| Model | Pilot10-15T (Fully Automated Silicone Oil Heated/Cooled Shelf Freeze Dryer) |
| Type | Standard Shelf-Type |
| Application | Pilot-Scale Production |
| Lyophilization Area | 1 m² |
| Ultimate Vacuum | ≤ 2.5 Pa |
| Condensate Capacity (24 h) | 15 kg/24 h |
| Cold Trap Temperature | ≤ −80 °C |
| Shelf Temperature Range | ≤ −50 °C (empty load) |
| Shelf Dimensions | 350 mm × 600 mm |
| Number of Shelves | 5 + 1 Radiant Shelf |
| Shelf Spacing | 70 mm |
| Installed Power | 8 kW (3-phase) |
| Unit Dimensions (W×D×H) | ≈ 880 × 2200 × 1900 mm |
| Weight | ≈ 1200 kg |
| Noise Level | ≤ 70 dB(A) |
| Brand | BIOCOOL |
|---|---|
| Origin | Shandong, China |
| Model | Pilot10-15T |
| Type | Shelf-Type Freeze Dryer |
| Application | Pilot-Scale Process Development & Intermediate-Scale Production |
| Freeze-Drying Area | 1 m² |
| Ultimate Vacuum | ≤ 2.5 Pa |
| Condenser Capacity (24 h) | 15 kg/24h |
| Condenser Temperature | ≤ −80 °C |
| Shelf Temperature Range (Empty Load) | ≤ −50 °C to +80 °C |
| Shelf Dimensions | 350 mm × 600 mm |
| Number of Shelves | 5 + 1 Radiant Shelf |
| Shelf Spacing | 70 mm |
| Installed Power | 8 kW (3-phase) |
| Unit Dimensions (W×D×H) | ≈ 880 × 2200 × 1900 mm |
| Weight | ≈ 1200 kg |
| Noise Level | ≤ 70 dB(A) |
| Compliance | GMP, GB/T 5226.1–1996 |
| Brand | BIOCOOL |
|---|---|
| Origin | Beijing, China |
| Model | Pilot10-15T |
| Type | Standard Shelf-Type Freeze Dryer |
| Application | Pilot-Scale |
| Freeze-Drying Area | 1 m² |
| Ultimate Vacuum | ≤ 2.5 Pa |
| Condenser Capacity (24 h) | 15 kg/24 h |
| Condenser Temperature | ≤ −80 °C |
| Shelf Temperature Range (Empty Load) | ≤ −50 °C to +80 °C |
| Shelf Dimensions | 350 mm × 600 mm |
| Number of Shelves | 5 + 1 Radiant Shelf |
| Shelf Spacing | 70 mm |
| Installed Power | 8 kW (3-phase) |
| Unit Dimensions (W×D×H) | ~880 × 2200 × 1900 mm |
| Weight | ~1200 kg |
| Noise Level | ≤ 70 dB(A) |
| Compliance | GMP, GB/T 5226.1–1996 |
| Brand | BIOCOOL |
|---|---|
| Origin | Beijing, China |
| Model | Pilot10-15T (Fully Automated Silicone-Oil Heated Shelf, Pilot-Scale Process Development) |
| Type | Standard Shelf-Type Freeze Dryer |
| Application Scale | Pilot-Scale |
| Lyophilization Area | 1 m² |
| Ultimate Vacuum | ≤ 2.5 Pa |
| Condenser Capacity (24 h) | 15 kg/24 h |
| Condenser Temperature | ≤ –80 °C |
| Shelf Temperature Range (Empty Load) | ≤ –50 °C to +70 °C |
| Shelf Dimensions | 350 mm × 600 mm |
| Number of Shelves | 5 + 1 Radiant Shelf |
| Shelf Spacing | 70 mm |
| Installed Power | 8 kW (3-phase) |
| Unit Dimensions (W×D×H) | ≈ 880 × 2200 × 1900 mm |
| Weight | ≈ 1200 kg |
| Noise Level | ≤ 70 dB(A) |
| Compliance Standards | GMP, GB/T 5226.1–1996, WHO TRS No. 986 Annex 6 |
| Brand | BIOCOOL |
|---|---|
| Origin | Beijing, China |
| Model | Pilot10-15T |
| Type | Shelf-Type Pilot Freeze Dryer |
| Lyophilization Area | 1 m² |
| Ultimate Vacuum | ≤ 2.5 Pa |
| Condenser Capacity | 15 kg/24h |
| Condenser Temperature | ≤ −80 °C |
| Shelf Temperature Range | ≤ −50 °C (empty) to +80 °C |
| Shelf Configuration | 5 active shelves + 1 radiation shelf |
| Shelf Dimensions | 350 mm × 600 mm |
| Shelf Spacing | 70 mm |
| Installed Power | 8 kW (3-phase) |
| Overall Dimensions (W×D×H) | 880 × 2200 × 1900 mm |
| Weight | ~1200 kg |
| Noise Level | ≤ 70 dB(A) |
| Compliance | GMP, GB/T 5226.1–1996 |
| Brand | BIOCOOL |
|---|---|
| Origin | Beijing, China |
| Model | Pilot10-15T |
| Type | Standard Shelf-Type Freeze Dryer |
| Application | Pilot-Scale Production & Process Development |
| Lyophilization Area | 1.05 m² |
| Ultimate Vacuum | ≤1 Pa |
| Condenser Capacity (24h) | 15 L/24h |
| Condenser Temperature (No-Load) | <−85 °C |
| Shelf Temperature Range | −55 °C to +70 °C |
| Shelf Cooling Method | Silicone Oil Circulation |
| Shelf Spacing | 80 mm |
| Compressor & Vacuum Pump | Imported Industrial-Grade Units |
| Hydraulic Stoppering System | Imported |
| Data Storage | Internal (3-month buffer), USB (optional), PC Database (optional) |
| Compliance | Designed for GLP/GMP-aligned environments |
| Control Interface | Industrial Touchscreen HMI with 50 ms real-time monitoring frequency |
| Brand | BIOCOOL |
|---|---|
| Origin | Beijing, China |
| Model | Pilot10-15T |
| Type | Shelf-Type Freeze Dryer |
| Application | Pilot-Scale Processing |
| Freeze-Drying Area | 1 m² |
| Ultimate Vacuum | ≤ 2.5 Pa |
| Condensate Capacity (24 h) | 15 L/24 h |
| Cold Trap Temperature (No Load) | ≤ −80 °C |
| Shelf Temperature Range (No Load) | ≤ −50 °C |
| Shelf Dimensions | 350 mm × 600 mm |
| Number of Shelves | 5 + 1 Radiant Shelf |
| Shelf Spacing | 70 mm |
| Installed Power | 8 kW (3-Phase) |
| Unit Dimensions (W×D×H) | ≈ 880 × 2200 × 1900 mm |
| Unit Weight | ≈ 1200 kg |
| Noise Level | ≤ 70 dB(A) |
| Compliance | GMP, GB/T 5226.1–1996 |
| Brand | BIOCOOL |
|---|---|
| Origin | Beijing, China |
| Model | Pilot10-15T |
| Type | Standard Shelf-Type Freeze Dryer |
| Application | Pilot-Scale Processing |
| Lyophilization Area | 1 m² |
| Ultimate Vacuum | ≤ 2.5 Pa |
| Condenser Capacity (24 h) | 15 kg/24 h |
| Condenser Temperature | ≤ −80 °C |
| Shelf Temperature Range (Empty Load) | ≤ −50 °C |
| Shelf Dimensions | 350 mm × 600 mm |
| Number of Shelves | 5 + 1 Radiant Shelf |
| Shelf Spacing | 70 mm |
| Installed Power | 8 kW (3-phase) |
| Unit Dimensions (W×D×H) | ≈ 880 × 2200 × 1900 mm |
| Weight | ≈ 1200 kg |
| Noise Level | ≤ 70 dB(A) |
| Compliance | GMP, GB/T 5226.1–1996 |
| Brand | BIOCOOL |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Pilot10-15T (Fully Automated Pilot-Scale Freeze Dryer) |
| Instrument Type | Shelf-Type Freeze Dryer |
| Application Scope | Pilot-Scale Processing |
| Lyophilization Area | 1 m² |
| Ultimate Vacuum | ≤ 2.5 Pa |
| Condensate Capacity (24 h) | 15 kg/24 h |
| Cold Trap Temperature | ≤ −80 °C |
| Shelf Temperature Range (Empty Load) | ≤ −50 °C |
| Shelf Dimensions | 350 mm × 600 mm |
| Number of Shelves | 5 + 1 Radiant Shelf |
| Shelf Spacing | 70 mm |
| Installed Power | 8 kW (3-phase) |
| Unit Dimensions (W×D×H) | ~880 × 2200 × 1900 mm |
| Unit Weight | ~1200 kg |
| Noise Level | ≤ 70 dB(A) |
| Brand | BIOCOOL |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | Pilot10-15T (1 m² Pilot-Scale Freeze Dryer) |
| Instrument Type | Standard Shelf-Type Freeze Dryer |
| Application Scope | Pilot-Scale Processing |
| Freeze-Drying Area | 1 m² |
| Ultimate Vacuum | < 2.5 Pa |
| Condensate Capacity (24 h) | 15 kg/24 h |
| Cold Trap Temperature | < −80 °C |
| Shelf Minimum Temperature (Empty Load) | ≤ −50 °C |
| Shelf Dimensions | 350 mm × 600 mm |
| Number of Shelves | 5 + 1 Radiant Shelf |
| Shelf Spacing | 70 mm |
| Installed Power | 8 kW (3-phase) |
| Cooling Method | Air-Cooled (Required Heat Dissipation Area: 8 m²) |
| Overall Dimensions (W×D×H) | ≈ 880 × 2200 × 1900 mm |
| Unit Weight | ≈ 1200 kg |
| Sound Pressure Level | ≤ 70 dB(A) |
| Compliance Standards | GMP Guidelines, GMP Implementation Manual for Pharmaceutical Production, GB/T 5226.1–1996 |
| Brand | BIOCOOL |
|---|---|
| Origin | Beijing, China |
| Model | Pilot10-15T (Freeze Dryer) |
| Type | Standard Heated Shelf Pilot-Scale Freeze Dryer |
| Application | Pilot-Scale Pharmaceutical & Biotech Processing |
| Lyophilization Area | 1 m² |
| Ultimate Vacuum | ≤ 2.5 Pa |
| Condenser Capacity | 15 kg/24 h |
| Condenser Temperature | ≤ −80 °C |
| Shelf Temperature Range | ≤ −50 °C (empty) to +80 °C |
| Shelf Configuration | 5 heated shelves + 1 radiation shelf |
| Shelf Dimensions | 350 mm × 600 mm |
| Shelf Spacing | 70 mm |
| Installed Power | 8 kW (3-phase) |
| Unit Dimensions (W×D×H) | ≈ 880 × 2200 × 1900 mm |
| Weight | ≈ 1200 kg |
| Noise Level | ≤ 70 dB(A) |
| Compliance | GMP, GB/T 5226.1–1996, EU Annex 1-aligned design principles |
| Validation Support | IQ/OQ documentation package, traceable calibration protocols, and qualification-ready architecture |
| Brand | BIOCOOL |
|---|---|
| Origin | Beijing, China |
| Model | Pilot10-15T |
| Freeze-Drying Area | 1 m² |
| Ultimate Vacuum | ≤ 2.5 Pa |
| Condenser Capacity | 15 kg/24h |
| Condenser Temperature | ≤ −80 °C |
| Shelf Temperature Range | ≤ −50 °C (empty) |
| Shelf Configuration | 5 + 1 radiant shelves (350 mm × 600 mm, 70 mm spacing) |
| Installed Power | 8 kW (3-phase) |
| Dimensions (W×D×H) | ≈ 880 × 2200 × 1900 mm |
| Weight | ≈ 1200 kg |
| Noise Level | ≤ 70 dB(A) |
| Compliance | GMP, GB/T 5226.1–1996 |
| Brand | BIOCOOL |
|---|---|
| Origin | Beijing, China |
| Model | Pilot10-15T (Wall-Mounted Pilot-Scale Freeze Dryer) |
| Type | Shelf-Type Freeze Dryer |
| Application Scale | Pilot-Scale |
| Shelf Area | 1 m² |
| Ultimate Vacuum | ≤ 2.5 Pa |
| Condensate Capacity (24 h) | 15 kg/24 h |
| Cold Trap Temperature | ≤ −80 °C |
| Shelf Minimum Temperature (Empty) | ≤ −50 °C |
| Installed Power | 8 kW (3-Phase) |
| Dimensions (W×D×H) | 880 × 2200 × 1900 mm |
| Weight | ~1200 kg |
| Noise Level | ≤ 70 dB(A) |
| Compliance | GMP, GB/T 5226.1–1996 |
| Brand | BIOCOOL |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Pilot2-4H |
| Instrument Type | Standard Shelf-Type Freeze Dryer |
| Application Scope | Pilot-Scale Production |
| Lyophilization Area | 0.2 m² |
| Ultimate Vacuum | <6 Pa |
| Condensate Capacity (24 h) | 6 L/24 h |
| Cold Trap Temperature | <−80 °C |
| Brand | BIOCOOL |
|---|---|
| Origin | Beijing, China |
| Model | Pilot2-4L |
| Type | Standard Shelf-Type Freeze Dryer |
| Application | Pilot-Scale Processing |
| Lyophilization Area | 0.2 m² |
| Ultimate Vacuum | <7 Pa |
| Condensate Capacity (24 h) | 4 L/24h |
| Cold Trap Temperature (No Load) | <−55 °C |
| Refrigeration Method | Direct Cooling |
| Shelf Temperature Range (No Load) | −40 °C to +60 °C |
| Shelf Spacing | 80 mm |
| Compressor Power | 7/8 HP |
| Vacuum Pump Speed | 2 L/s |
| Safety Features | Overcurrent Protection, Overload Protection, 36 V Low-Voltage Heating Circuit, Shelf Overtemperature Protection, Vacuum Process Interlock, Vacuum Pump Anti-Backflow Device |
| Warranty | 18 Months (Excluding Vacuum Pump) |