Bruker
Filter
Showing 271–300 of 315 results
| Brand | Bruker |
|---|---|
| Origin | Belgium |
| Model | SkyScan 1273 |
| X-ray Source | 40–130 kV, up to 39 W |
| Detector | 6 MP CMOS flat-panel (3072 × 1944 pixels) |
| Spatial Resolution | < 5 µm |
| Voxel Size | < 3 µm |
| Max Sample Dimensions | Ø250 mm × H250 mm |
| Max Sample Weight | 20 kg |
| Reconstructed Volume | up to 4800 × 4800 pixels |
| External Dimensions | 1250 × 815 × 820 mm (W × D × H) |
| Radiation Leakage | < 1 µSv/h at any point on external surface |
| Power Supply | 100–240 V, 50–60 Hz, 3 A |
| Weight | 400 kg (net) |
| Brand | Bruker |
|---|---|
| Origin | Belgium |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SkyScan 1275 |
| X-ray Source | 20–100 kV, 10 W, < 5 µm focal spot size at 4 W |
| Detector | 3 MP CMOS flat-panel detector (1944 × 1536 effective pixels) |
| Spatial Resolution | < 4 µm (nominal, at maximum magnification) |
| Density Resolution | < 4 µm (nominal, inferred from spatial resolution and contrast transfer performance) |
| Sample Capacity | Max height 120 mm, max diameter 96 mm |
| Dimensional Measurement Accuracy | Consistent with < 4 µm spatial resolution under calibrated conditions |
| Density Measurement Accuracy | Supported by high dynamic range (16-bit) detector and beam-hardening correction algorithms |
| Power Requirement | Standard 230 V AC, 50/60 Hz, single-phase outlet |
| Radiation Safety | Compliant with IEC 61000-6-3, IEC 61000-6-4, and national regulatory requirements for Class II B radiation devices |
| Brand | Bruker |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China-made) |
| Model | SKYSCAN 1275 |
| Service Pricing | USD 5,000–10,000 per scan session |
| Years of Service Experience | 3 |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | SkyScan 1276 |
| Imaging Modality | X-ray micro-computed tomography (micro-CT) |
| Spatial Resolution (nominal) | ≤2.8 µm |
| Scan Modes | Step-and-shoot, continuous gantry rotation with slip-ring interface |
| Scan Time per Reconstruction | as low as 3.9 s |
| Reconstructed Slice Count per Scan | >1600 slices |
| Max Image Matrix Size | 8000 × 8000 pixels |
| X-ray Source Voltage Range | 20–100 kV adjustable |
| Automatic Filter Changer | 6-position |
| Dose Reduction Technology | Beam-shaping collimator (patented by Bruker microCT) |
| Physiological Monitoring Integration | Respiratory gating, ECG synchronization, temperature stabilization, motion detection |
| Animal Handling | Interchangeable mouse/rat beds with integrated anesthesia mask and sensor interface |
| Real-time Dose Monitoring | On-screen dosimetry derived from projection image analysis |
| Reconstruction Acceleration | GPU-accelerated algorithms + InstaRecon® layered reconstruction (≥10× faster than conventional FBP) |
| Software Compliance | GLP-compliant software suite with audit trail, user access control, and electronic signature support |
| Data Export & Remote Viewing | Direct export to iOS/Android devices via dedicated viewer app |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | SkyScan 2211 |
| X-ray Source | 20–190 kV, 4/10/25 W, sub-micron focal spot size, 5-position filter wheel |
| X-ray Target | Tungsten (standard) |
| Detector | 3 MP CMOS flat panel (1920 × 1536 px) or 11 MP cooled CCD (4032 × 2670 px) |
| Reconstruction Volume (CMOS) | up to 3776 × 3776 × 1160 px (dual offset mode) |
| Reconstruction Volume (CCD) | up to 8000 × 8000 × 2272 px (dual offset mode) |
| Spatial Resolution | down to 100 nm (detector-limited, geometry-dependent) |
| Sample Capacity | Ø204 mm × L200 mm, max. 25 kg |
| Sample Positioning | direct-drive air-bearing rotation stage with integrated piezo-driven micro-positioning (5.5 mm travel) |
| Reconstruct Time | 1 min 12 sec (600 projections, 2K × 2K × 1K) |
| Radiation Safety | <0.5 µSv/h at 10 cm from surface (measured at 190 keV, 4 W on target) |
| Power Supply | 100–130 V or 200–240 V AC, 50–60 Hz |
| Cooling & Air Supply | integrated closed-loop water chiller and oil-free air compressor with particle filters and desiccant dryer |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SKYSCAN 2214 CMOS |
| Price | USD 280,000 (FOB Hamburg) |
| Brand | Bruker |
|---|---|
| Origin | Belgium |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SKYSCAN 2214 |
| X-ray Source | 20–100 kV, 10 W, <5 µm focal spot size at 4 W |
| Maximum Voxel Resolution | <0.35 µm (16 MP detector) / <0.45 µm (11 MP detector) |
| Max Reconstructed Volume | 14456 × 14456 × 2630 px (16 MP) or 11840 × 11840 × 2150 px (11 MP) |
| Sample Capacity | Ø ≤ 75 mm, H ≤ 70 mm (standard) |
| Detector | 16 MP (4904 × 3280 px) or 11 MP (4032 × 2688 px), 14-bit cooled CCD coupled 1:1 to scintillator via fiber optic taper |
| Spatial & Density Resolution | <0.35 µm (16 MP) / <0.45 µm (11 MP), isotropic voxel capability |
| Reconstruction Engine | InstaRecon® real-time GPU-accelerated 3D reconstruction |
| Scan Modes | Cone-beam, helical, phase-contrast enabled, dynamic time-lapse |
| Compliance | Fully compatible with ASTM E1441, ISO 15732, and USP <1059> for non-destructive volumetric analysis |
| Brand | Bruker |
|---|---|
| Origin | Belgium |
| Model | SKYSCAN 2214 |
| X-ray Source | 20–100 kV, 10 W, <5 µm focal spot size at 4 W |
| Maximum Reconstruction Volume | 14456 × 14456 × 2630 px (16 MP detector) or 11840 × 11840 × 2150 px (11 MP detector) |
| Spatial Resolution | <0.35 µm (16 MP), <0.45 µm (11 MP) |
| Sample Capacity | Ø ≤ 75 mm, H ≤ 70 mm |
| Detector | 16 MP (4904 × 3280 px) or 11 MP (4032 × 2688 px), 14-bit cooled CCD coupled 1:1 to scintillator via fiber optic taper |
| Density Resolution | <0.35 µm (16 MP), <0.45 µm (11 MP) |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SkyScan1278 |
| Instrument Type | Tomographic Imaging System |
| Energy Resolution | 17% |
| Spatial Resolution | 50 µm |
| Scan Time | 7.2 s per full-body mouse scan |
| Field of View Diameter | 80 mm |
| Scan Length | 200 mm |
| Sample Capacity | 1 animal per scan |
| X-ray Source | Adjustable 20–65 kV microfocus tube with patented beam shaping optics |
| Detector | High-sensitivity CMOS flat-panel detector |
| Dose Level | <6 mGy for whole-body murine scan |
| Physiological Gating | Integrated respiratory, ECG, temperature, and motion monitoring |
| Data Output Formats | DICOM, TIFF, JPG, BMP, PNG, AVI |
| Software Compliance | GLP-compliant acquisition and reconstruction suite |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | solariX |
| Instrument Type | FTMS (Fourier Transform Mass Spectrometer) |
| Magnetic Field Strength Options | 7T, 12T, 15T |
| Ionization Modes | ESI and MALDI (dual-source configurable) |
| Detection Technology | ParaCell detector with AMP (Absorption Mode Processing) |
| Software Platform | Bruker Compass suite including SmartFormula |
| Compliance Framework | Designed for GLP/GMP environments |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | SPR #64 |
| Instrument Type | Surface Plasmon Resonance (SPR) |
| Channel Configuration | 8-Channel Orthogonal Flow Cell with 64 Sensor Spots |
| Fluidic Flexibility | Up to 8 Simultaneous Buffer Streams |
| Automation Interface | RESTful API & Robotic Integration Ready |
| Sample Format Support | 96-well & 384-well Microplates, Reagent Reservoirs, External Cooling-Compatible Stage |
| Cleaning Mechanism | Integrated Dual-Prism Cartridge with Auto-Clean Protocol |
| Data Output Format | Open HDF5, CSV, and JSON |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TANGO |
| Instrument Type | Laboratory |
| Principle | Fourier Transform (FT) |
| Wavelength Range | 11,500–4,000 cm⁻¹ |
| Scan Speed | 8 scans/sec |
| Data Sampling Interval | 4 cm⁻¹ |
| Measurement Modes | Diffuse Reflectance / Transmission |
| Chemometrics Software | OPUS |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Instrument Type | Laboratory FTIR Spectrometer |
| Model | Tensor 27 |
| Instrument Category | Fourier Transform Infrared Spectrometer |
| Condition | Professionally Refurbished |
| Compliance | Meets ISO/IEC 17025 calibration traceability standards for used analytical instrumentation |
| Brand | Bruker |
|---|---|
| Origin | USA |
| Model | TI 980 |
| Instrument Type | Nanoindentation and Scratch Tester |
| Key Technology | Three-Plate Capacitive Transduction |
| Compliance | ASTM E2546, ISO 14577, ISO 20503, USP <1062> |
| Optional Modules | High-Temperature Stage, Electrical Characterization Module, Humidity Control Chamber, Cryogenic Stage, Raman Coupling Interface |
| Brand | Bruker |
|---|---|
| Origin | USA |
| Model | TI 990 |
| Drive Technology | Electrostatic actuation |
| Noise Floor | <0.1 nm RMS displacement noise |
| Maximum Load Resolution | 50 nN |
| Depth Resolution | <0.01 nm |
| Active Vibration Isolation | Integrated pneumatic + electromagnetic hybrid system |
| Platform | Precision granite base with environmental enclosure |
| Control Architecture | Performech III dual-lock-in parallel processing module |
| Software Platform | Tribo iQ v4.x (FDA 21 CFR Part 11 compliant audit trail, GLP/GMP-ready reporting) |
| Brand | Bruker |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TI Premier II |
| Instrument Type | Nanoindentation and Scratch Tester |
| Measurement Principle | Capacitive Displacement Sensing with Electromechanical Actuation |
| Compliance Framework | ASTM E2546, ISO 14577, ISO 20519, USP <1062>, GLP/GMP-Ready Data Integrity Architecture |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Instrument Type | Trapped Ion Mobility Spectrometry (TIMS) Mass Spectrometer |
| Model | timsMetabo™ |
| Application Scope | Universal (Metabolomics, Lipidomics, Untargeted Small-Molecule Analysis) |
| Regulatory Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Instrument Type | Trapped Ion Mobility Spectrometry (TIMS)–based Mass Spectrometer |
| Model | timsOmni |
| Application Scope | Universal for native and denatured proteoforms, intact proteins, oligonucleotides, PTMs, small molecules, and multi-specific biologics |
| Regulatory Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | timsTOF fleX™ |
| Instrument Type | Trapped Ion Mobility Spectrometry (TIMS) Mass Spectrometer |
| Application Scope | Universal Platform for Spatial Omics and Molecular Imaging |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Instrument Type | Ion Mobility Mass Spectrometer |
| Model | timsTOF fleX with MALDI-2 |
| Application Scope | Universal (Biological Tissue Imaging, Lipidomics, Metabolomics, Drug Distribution Studies) |
| Regulatory Compliance | Designed for GLP/GMP-aligned workflows |
| Software Platform | SCiLS Lab, DataAnalysis, and TIMS Control integrated in Compass 6.0 suite |
| Ionization Modes | MALDI and MALDI-2 (laser post-ionization), ESI (via LC coupling) |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | timsTOF HT |
| Instrument Type | Trapped Ion Mobility Spectrometry (TIMS) Mass Spectrometer |
| Technology | Parallel Accumulation–Serial Fragmentation (PASEF®), CCS-enabled 4D-Proteomics |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Instrument Type | Trapped Ion Mobility Spectrometry–Time-of-Flight Mass Spectrometer (TIMS-TOF MS) |
| Ionization Modes | Dual MALDI/ESI |
| Application Focus | Label-free Ultra-High-Throughput Screening (uHTS) in Drug Discovery |
| Software Platform | MALDI PharmaPulse® 2023 |
| Compliance Ready | GLP/GMP-aligned data handling, 21 CFR Part 11–compatible audit trail (via optional software configuration) |
| Throughput | Up to 3 samples/sec on 1536-well plates |
| CCS Calibration | Yes, with internal standards |
| MALDI Source | 10 kHz smartbeam™ 3D laser, MALDI-2 option available |
| Sample Handling | Robotic MALDI target auto-loader, disposable targets (96–1536-well compatible) |
| Data Export | Native support for Genedata Screener®, Assay Explorer, and other HTS informatics platforms |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | timsTOF Pro 2 |
| Instrument Type | Trapped Ion Mobility Spectrometry (TIMS) Mass Spectrometer |
| Application Domain | Specialized Omics Research (Proteomics, Lipidomics, Phosphoproteomics, Clinical Biomarker Discovery) |
| Regulatory Context | Compliant with GLP/GMP data integrity requirements |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Instrument Type | Trapped Ion Mobility Spectrometry–Time-of-Flight Mass Spectrometer (TIMS-TOF) |
| Model | timsTOF SCP |
| Application Domain | Specialized Single-Cell Proteomics, Immunopeptidomics, PTM Analysis, Epigenoproteomics |
| Ion Source | Optimized Dual-Orthogonal Reflectron Ion Source with 1-mm Transfer Capillary |
| Vacuum Architecture | 8-stage Differential Vacuum System |
| Acquisition Mode | dia-PASEF® (Data-Independent Acquisition Parallel Accumulation–Serial Fragmentation) |
| CCS Capability | Yes, Collision Cross Section–enabled Ion Mobility Separation |
| Scan Speed | >120 Hz MS/MS |
| Software Platform | timsControl, PaSER (Real-time Parallel Database Search Engine), Compatible with MaxQuant/Perseus, PEAKS Studio |
| Data Format | Open .d Format (Bruker) |
| Regulatory Compliance | Supports 21 CFR Part 11–compliant workflows (audit trail, electronic signatures, data integrity controls) |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | timsUltra AIP |
| Instrument Type | Trapped Ion Mobility Spectrometry (TIMS) Mass Spectrometer |
| Application Scope | Specialized Proteomics & Multi-Omics Platforms |
| Software Integration | TIMS PASEF®, TIMScore™, DIA-NN 4D-Proteomics™, Spectronaut® 20, ICC 2.0 |
| Brand | Bruker |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | TRACER 5 |
| Application | Handheld / Portable |
| Industry Use | General-Purpose |
| Elemental Range | F to U |
| Quantification Range | ppm to wt% |
| Energy Resolution | 145 eV |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | TRACER 5g |
| Application | Handheld/Portable |
| Instrument Type | General-Purpose Research-Grade ED-XRF |
| Industry-Specific Use | Geoscience & Mineral Exploration |
| Elemental Range | Na (Z=11) to U (Z=92) |
| Quantification Range | 1 ppm – 99.99% |
| Energy Resolution | <140 eV |
| Repeatability | 0.1% RSD |
| Detector | Silicon Drift Detector (SDD) with 1 µm Graphene Window |
| Brand | Bruker |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Tracer 5i |
| Application | Handheld/Portable |
| Industry Type | General-Purpose |
| Elemental Range | Na (11) – U (92), down to F (9) under vacuum/He flush |
| Quantification Range | 1 ppm – 99.99% |
| Energy Resolution | <140 eV (at Mn Kα) |
| Repeatability | 0.1% RSD |
| Detector | Silicon Drift Detector (SDD) |
| Brand | Bruker |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | TriboLab CMP |
| Instrument Type | Multifunctional Tribological Tester |
| Maximum Friction Force | 200 N |
| Friction Force Resolution | 10 mN |
| Maximum Operating Temperature | 1000 °C |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Type | Total Reflection X-ray Fluorescence (TXRF) Spectrometer |
| Model | Blood Heavy Metal Analyzer |
| Element Range | Al (13) to U (92) |
| Detection Limit | 2 pg |
| Sample Volume (Liquid/Suspension) | 1–50 µL |
| Sample Mass (Powder) | <10 µg |
| Detector | 4th-Generation XFlash® SDD Silicon Drift Detector |
| Cooling | Peltier (No Liquid Nitrogen Required) |
| Energy Resolution | <160 eV at Mn Kα (100 kcps) |
| Automation Options | 1-position or 25-position Auto-sampler |
| Compliance | ASTM D7782, ISO 17294-2, USP <232>/<233>, GLP/GMP-ready data integrity features |