Bruker
Filter
Showing 181–210 of 315 results
| Key | Brand: Bruker |
|---|---|
| Origin | Germany |
| Model | PepSep™ C18 |
| Type | Reversed-phase analytical column for nano/micro-flow LC-MS |
| Packing Material | Surface-modified silica with endcapping |
| Particle Size | 1.6 µm (typical for PepSep™ series) |
| Pore Size | 100 Å |
| Column ID | 75 µm × 25–50 cm (standard configurations) |
| Pressure Rating | ≤1000 bar |
| Compatible With | NanoLC, microLC, and timsTOF platforms (e.g., timsTOF Pro, timsTOF SCP) |
| Surface Chemistry | C18 bonded phase with low silanol activity |
| Batch-to-batch reproducibility | ≤3% RSD in retention time (n=5 injections, standard peptide mix) |
| Brand | Bruker |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PET/MR 3T |
| Imaging Modality | Integrated Positron Emission Tomography / Magnetic Resonance Imaging |
| Energy Resolution | 17% FWHM at 511 keV |
| Spatial Resolution (PET) | <0.7 mm (NEMA NU-4) |
| Spatial Resolution (MRI) | ≤1.2 mm isotropic (with CryoProbe™) |
| Scan Speed | Up to 10 min per dynamic PET frame (variable by protocol) |
| Field of View (FOV) | 80 mm (PET transaxial), 148 mm (MRI transaxial), 285 mm (whole-body MRI longitudinal) |
| Animal Capacity | 1 subject per scan (mouse or rat) |
| Brand | Bruker |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PI 89 |
| Pricing | Available Upon Request |
| Brand | Bruker |
|---|---|
| Origin | USA |
| Model | PI 89 AUTO |
| Application Domain | In situ SEM-integrated nanomechanical characterization |
| Automation Level | Fully motorized stage + patented dual-axis rotation/tilt (R/T) mechanism |
| Software Platform | TriboScan Auto v5.0+ |
| Compliance Framework | Designed for GLP-compliant workflows |
| Sample Environment | Compatible with standard high-vacuum and low-vacuum SEM chambers (FEI, Thermo Fisher, Zeiss, JEOL) |
| Maximum Load Resolution | Sub-100 nN |
| Displacement Resolution | < 0.05 nm |
| Stage Precision | ±50 nm positional repeatability over 10 mm × 10 mm travel range |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Instrument Type | Benchtop |
| Excitation Source | Spark |
| Detector Configuration | Dual Detector (PMT + CCD) |
| Focal Length | 400 mm |
| Grating Groove Density | 3600 lines/mm |
| Wavelength Range | 170–685 nm |
| Number of Analytical Channels | 32 |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Instrument Type | Benchtop |
| Excitation Source | Spark Discharge |
| Detector Configuration | Dual Detector (PMT + CCD) |
| Focal Length | 400 mm |
| Grating Groove Density | 3600 lines/mm |
| Wavelength Range | 170–685 nm |
| Number of Analytical Channels | 32 |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | Q4 POLO |
| Instrument Type | Benchtop |
| Excitation Method | Spark |
| Detector Type | Photomultiplier Tube (PMT) |
| Focal Length | 800 mm |
| Grating Groove Density | 3600 lines/mm |
| Wavelength Range | 120–200 nm |
| Number of Channels | 128 |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | Q4 POLO |
| Instrument Type | Benchtop |
| Excitation Method | Spark |
| Detector Type | Photomultiplier Tube (PMT) |
| Focal Length | 800 mm |
| Grating Groove Density | 3600 lines/mm |
| Wavelength Range | 120–785 nm (dual optical paths: 130–785 nm total coverage) |
| Number of Channels | 128 |
| Optical System | MultiVision™ with argon-purged vacuum UV path |
| Temperature Compensation | AAC™ Active Ambient Compensation |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Q4 TASMAN |
| Instrument Type | Desktop |
| Excitation Method | Spark |
| Detector Type | Dual Detector (PMT + CCD) |
| Focal Length | 800 mm |
| Grating Groove Density | 3600 lines/mm |
| Wavelength Range | 130–800 nm |
| Number of Channels | 128 |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Instrument Type | Benchtop |
| Excitation Method | Spark |
| Detector Type | Dual Detector (PMT + CCD) |
| Focal Length | 800 mm |
| Grating Groove Density | 3600 lines/mm |
| Wavelength Range | 130–800 nm |
| Number of Channels | 128 |
| Argon Consumption | 2–4 L/min (during analysis) |
| Detector Pixel Count / Pixel Size | 3880 pixels per CCD chip |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Q4 TASMAN |
| Instrument Type | Benchtop |
| Excitation Method | Spark |
| Detector Type | Dual Detector (PMT + CCD) |
| Focal Length | 800 mm |
| Grating Groove Density | 3600 lines/mm |
| Wavelength Range | 130–800 nm |
| Number of Channels | 128 |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Q4 TASMAN |
| Instrument Type | Benchtop |
| Excitation Method | Spark |
| Detector Type | Dual Detector (PMT + CCD) |
| Focal Length | 800 mm |
| Grating Groove Density | 3600 lines/mm |
| Wavelength Range | 130–800 nm |
| Number of Channels | 128 |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | Q6 NEWTON |
| Instrument Type | Benchtop |
| Excitation Method | Spark |
| Detector Type | Photomultiplier Tube (PMT) |
| Focal Length | 800 mm |
| Grating Groove Density | 3600 lines/mm |
| Wavelength Range | 120–200 nm |
| Number of Channels | 128 |
| Argon Consumption | 2–4 L/min (during analysis) |
| Detector Pixel Count / Pixel Size | 3880 pixels per single detector block |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Instrument Type | Benchtop |
| Excitation Source | Spark |
| Detector Type | Photomultiplier Tube (PMT) |
| Focal Length | 800 mm |
| Grating Density | 3600 lines/mm |
| Wavelength Range | 120–200 nm |
| Number of Channels | 128 |
| Argon Consumption | 2–4 L/min (during analysis) |
| Detector Configuration | Single PMT with 3880 discrete detection channels |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Instrument Type | Benchtop |
| Excitation Method | Spark |
| Detector Type | Photomultiplier Tube (PMT) |
| Focal Length | 1000 mm |
| Grating Groove Density | 3600 lines/mm |
| Wavelength Range | 110–800 nm |
| Number of Channels | 128 |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Instrument Type | Benchtop |
| Excitation Method | Spark |
| Detector Type | Photomultiplier Tube (PMT) |
| Focal Length | 1000 mm |
| Grating Groove Density | 3600 lines/mm |
| Wavelength Range | 110–800 nm |
| Number of Channels | 128 |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | QUANTAX EBSD |
| Pricing | Upon Request |
| CCD Camera Resolution | 640 × 480 pixels |
| Maximum Stage Speed | 10 mm/s |
| Spatial Resolution | 1.5 nm |
| Angular Resolution | 0.1° |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model Series | QUANTAX Transmission Electron Microscopy (TEM/STEM) EDS |
| Energy Resolution | <129 eV |
| Peak-to-Background Ratio | 20,000:1 |
| Maximum Count Rate | 1500 kcps |
| Elemental Detection Range | Be to Cf |
| Detector Active Area | 10–300 mm² |
| Window Options | Polymer Ultrathin Window or Windowless |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | QUANTAX FlatQUAD |
| Energy Resolution | <129 eV |
| Peak-to-Background Ratio | 20,000:1 |
| Maximum Count Rate | 4,000 kcps |
| Elemental Detection Range | Boron (B) to Californium (Cf) |
| Detector Active Area | 10–300 mm² |
| Window Type | Windowless |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | Quantax XFlash Series |
| Energy Resolution | <129 eV |
| Peak-to-Background Ratio | 20,000:1 |
| Maximum Count Rate | 1,500 kcps |
| Elemental Detection Range | Be to Cf |
| Detector Active Area | 10–300 mm² |
| Window Options | Ultrathin Polymer Window or Windowless Configuration |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | QUANTAX xsense |
| Pricing | Upon Request |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | QUANTAX XTrace |
| Pricing | Available Upon Request |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | RAM II |
| Instrument Type | FT-Raman Module |
| Spectral Range | 3600 – 50 cm⁻¹ (Stokes shift) |
| Compatibility | INVENIO, VERTEX 70v, VERTEX 80v, VERTEX 80 vacuum FTIR spectrometers |
| Laser Source | Software-controlled Nd:YAG (1064 nm) |
| Detector Options | Room-temperature InGaAs (1× or 2×), proprietary liquid-nitrogen-cooled Ge photodiode |
| Cooling Duration | Up to 7 days per fill |
| Optical Coupling | Dual fiber-optic ports, 90° scattering geometry, defocusing optics |
| Sample Stage | Motorized XYZ stage with focus control |
| Calibration Source | Integrated spectral response correction lamp |
| Software Platform | OPUS v8.x or later with automated FT-Raman/FT-IR switching |
| Brand | Bruker |
|---|---|
| Origin | USA |
| Model | S1 TITAN 200 |
| Instrument Type | Heavy Metal Contaminant Analyzer |
| Elemental Range | ≥40 elements (S–U) |
| Application Scope | Soil, sediment, sludge, dust, filter media, solid waste |
| Compliance | Meets ASTM D6739, EPA Method 6200, ISO 18551, and EU RoHS/WEEE screening requirements |
| Detector | High-resolution silicon drift detector (SDD) |
| Excitation Source | Rhodium-target microfocus X-ray tube |
| Operating Environment | Field-deployable (–10 °C to 50 °C), IP54 rated |
| Data Output | Quantitative ppm/wt% results with statistical uncertainty reporting |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | S1 TITAN 300 |
| Application | Handheld/Portable |
| Industry-Specific Type | Non-Ferrous & Alloy Metals |
| Elemental Range | Mg–U (High-Performance Configuration) / Ti–U (Standard Configuration) |
| Quantification Range | 1 ppm – 99.99 wt% |
| Energy Resolution | <140 eV (at Mn Kα) |
| Repeatability | ≤0.1% RSD (for major elements under controlled conditions) |
| Detector | Silicon Drift Detector (SDD) |
| Brand | Bruker |
|---|---|
| Origin | USA |
| Model | S1 TITAN |
| Application | Handheld/Portable |
| Industry-Specific Type | Geological & Mining |
| Elemental Range | Na (11) to U (92) |
| Concentration Range | 1 ppm – 99.99% |
| Energy Resolution | < 140 eV |
| Repeatability | 0.1% |
| Detector | Silicon Drift Detector (SDD) |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | S1 TITAN |
| Application | Field-Portable |
| Element Range | Mg–U |
| Detection Limit | 1 ppm–99.99% |
| Energy Resolution | <140 eV (Mn Kα) |
| Repeatability | ±0.1% RSD |
| Detector | Silicon Drift Detector (SDD) |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | S1 TITAN |
| Application | Handheld/Portable |
| Element Range | Mg–U |
| Concentration Range | 1 ppm – 99.99% |
| Energy Resolution | <140 eV (Mn Kα) |
| Detector | Silicon Drift Detector (SDD) |
| Weight | 1.23 kg |
| X-ray Tube | 50 kV |
| Compliance | ASTM F963, RoHS, USP <232>/<233>, EPA Method 6200, ISO 12885, EN 62321 |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Configuration | Handheld Portable |
| Element Range | Mg–U |
| Detection Limit | 1 ppm |
| Concentration Range | 1 ppm – 99.99 wt% |
| Energy Resolution | <140 eV (Mn Kα) |
| Detector Type | Silicon Drift Detector (SDD) |
| Compliance | CE, RoHS, FCC Class B, IEC 61000-4-2/3/4/6 |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | S1 TITAN |
| Application | Handheld / Portable |
| Industry Type | General-Purpose |
| Elemental Range | Mg–U |
| Quantification Range | 1 ppm – 99.99% |
| Energy Resolution | <140 eV (Mn Kα) |
| Detector | Silicon Drift Detector (SDD) |
| X-ray Tube | 50 kV |
| Weight | 1.23 kg |
| Display | Integrated Color Touchscreen |
| Key Technologies | SharpBeam® X-ray Geometry Optimization, SMART®Grade Timing Algorithm, X-Flash® SDD |