Generic
Filter
Showing 3001–3030 of 5744 results
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | WNB7 |
| Price Range | USD 26,000 – 39,000 |
| Origin | Switzerland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MENHIR-1550 |
| Key Components | Solid-state femtosecond laser system with integrated fiber-optic and free-space output |
| Center Wavelength | 1560 nm ± 10 nm |
| Repetition Rate | Up to 2.5 GHz (standard: 250/500 MHz, 1/1.25/2/2.5 GHz |
| Pulse Width | < 200 fs, transform-limited |
| Average Output Power | >50 mW (MENHIR-1550), up to 2 W (MENHIR-1550+) |
| Pulse Energy | >0.05 nJ (MENHIR-1550), up to 1 nJ (MENHIR-1550+) |
| Peak Power | >0.1 kW (MENHIR-1550), up to 4 kW (MENHIR-1550+) |
| Spectral Bandwidth | >12.5 nm (3 dB) |
| Amplitude Noise | < 0.1% RMS (24 h) |
| Timing Jitter | < 30 fs (1 kHz – 10 MHz) |
| Beam Quality | TEM₀₀, M² < 1.05 |
| Polarization | Linear, PER > 23 dB (>200:1) |
| Output Interface | Polarization-maintaining fiber (FC/APC) and collimated free-space beam |
| Power Supply | 5 V / 2 A (MENHIR-1550), 24 V / 2 A (MENHIR-1550+) |
| Power Consumption | < 10 W (MENHIR-1550), < 50 W (MENHIR-1550+) |
| Cooling | Active air-cooling |
| Warm-up Time | < 10 s (cold start) |
| Dimensions & Weight | 240 mm × 160 mm × 89 mm, 5 kg |
| Operating Temperature | 5 – 45 °C |
| Analog I/O | Power modulation, alarm, internal lock, trigger, status monitoring |
| Digital Interfaces | USB, RS-232, Ethernet, CAN |
| Origin | Germany |
|---|---|
| Supplier Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | RQflex® 20 |
| Price | Upon Request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Pricing | Upon Request |
| Measurement Principle | 90° Nephelometric Scattering |
| Light Source | Tungsten Lamp (Turb 550) / Infrared LED (Turb 550 IR) |
| Range | 0.01–1000 NTU, Auto-ranging |
| Resolution | 0.01 NTU (0.00–9.99), 0.1 NTU (10.0–99.9), 1 NTU (100–1000) |
| Accuracy | ±2% of reading or ±0.01 NTU |
| Repeatability | <±1% of reading or ±0.01 NTU |
| Calibration | Auto 1–3-point with user-definable intervals |
| Response Time | 3 s |
| Display | Dual-line LCD with special character support |
| Sample Cell | 28 × 70 mm round glass vial |
| Sample Volume | 25 mL |
| Interface | RS232 serial output |
| Real-time Clock & Calendar | Integrated |
| GLP Compliance | Calibration due-date alert, operator ID logging, measurement timestamping |
| Dimensions (L×W×D) | 250 × 290 × 110 mm |
| Operating Temperature | 10–40 °C |
| Power Supply | 90–250 VAC via external transformer |
| Certifications | CE, UL, cUL, TÜV/GS |
| Standard Kit | Universal power adapter, three blank cuvettes, English operating manual, quick-reference guide |
| Origin | USA |
|---|---|
| Manufacturer | METEK GmbH (Germany), Distributed in North America |
| Instrument Type | Imported High-Precision Turbulence-Grade 3D Ultrasonic Anemometer |
| Model | uSonic-3 Cage MP / uSonic-3 Class A MP |
| Sampling Rate | Up to 30 Hz per transducer pair (90 Hz total radial data rate) |
| Wind Speed Range | ±40 m/s |
| Operating Temperature | −40 °C to +60 °C |
| Relative Humidity | 5–100 % RH |
| Wind Accuracy | ±0.5–1 % RMS @ 5 m/s (horizontal, 0°–20° sector) |
| Vertical Velocity Resolution | 0.006 m/s |
| Temperature Resolution | 0.01 K |
| Output Data | 9 radial wind components, 9 sonic temperature values, Cartesian (u, v, w), scalar wind speed & direction, turbulence statistics (with optional module) |
| Communication | RS422, RS485 (300–115.2 kbaud), 10/100 Mbit Ethernet (ASCII protocol, NMEA-compliant framing, checksum support) |
| Power | 10–36 VDC, 2.5 W (heating optional: 10–24 VDC, ≤100 W) |
| Mounting Options | Cage-mount (Cage MP) or Class A meteorological mast mount (Class A MP) |
| Compliance | Designed for eddy covariance systems compliant with AmeriFlux, ICOS, and FLUXNET protocols |
| Origin | Switzerland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model(s) | AE50, AE163, AE200 |
| Operational Age | 3–4 years |
| Warranty | 6 months |
| Compliance | Fully tested per Mettler Toledo service protocols |
| Calibration Documentation | Available upon request |
| Packaging | Original or certified refurbished shipping crate |
| Origin | Switzerland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | AG245 |
| Price Range | USD 1,400–7,200 (FOB) |
| Product Category | Precision Weighing Instrument |
| Operational Age | 3–4 years |
| Warranty | 6 months |
| Instrument Serial Verification | Performed per ISO/IEC 17025 traceable procedures |
| Key | Readability: 0.1 mg |
|---|---|
| Max Capacity | 110 g |
| Repeatability | 0.1 mg |
| Linearity | ±0.2 mg |
| Pan Diameter | Ø90 mm |
| Draft Shield Height | 220 mm |
| Dimensions (W×D×H) | 238 × 335 × 364 mm |
| External Calibration | 100 g weight (optional) |
| Interface | RS232 |
| Housing Material | Corrosion-resistant ABS engineering plastic |
| Built-in Applications | Weighing, Percentage Weighing, Piece Counting, Dynamic Weighing, Net/Gross/Tare Addition/Subtraction |
| Compliance | Designed for GLP/GMP environments with audit-ready data handling capabilities |
| Origin | Switzerland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Models | AT20 / AT200 / AT261 |
| Warranty | 6 months |
| Operational Age | 3–4 years |
| Calibration Status | Verified and Functionally Tested |
| Compliance | Meets ISO/IEC 17025 traceable verification standards (per SpectraLab Scientific in-house protocol) |
| Reconditioning Level | Refurbished to OEM functional specifications |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | FE20K |
| Price | USD 580 (approx.) |
| pH Range | 0.00–14.00 |
| Resolution | 0.01 pH |
| Accuracy | ±0.01 pH |
| mV Range | ±1999 mV |
| mV Accuracy | ±1 mV |
| Temperature Range | 0–100 °C |
| Calibration Points | Up to 3-point |
| Temperature Compensation | Automatic or Manual |
| Endpoint Detection | Automatic or Manual |
| Buffer Recognition | Yes |
| Electrode Status Indicator | Yes |
| Slope Display | Yes |
| Reference Electrode Input | Yes |
| Origin | Switzerland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PB3002 |
| Warranty | 6 months |
| Operational Age | 3–4 years |
| Price Range | USD 1,400–7,000 (FOB) |
| Compliance | ISO/IEC 17025-aligned calibration documentation available |
| Included Accessories | Draft shield, calibration weights (class E2), RS232 interface cable, user manual (English) |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | PL2002 |
| Price | USD 1,090 (FOB Shanghai) |
| Readability | 0.01 g |
| Max Capacity | 2100 g |
| Repeatability (SD) | 0.01 g |
| Linearity Error | ±0.02 g |
| Stabilization Time | ≤3.0 s |
| Calibration | External, 2000 g weight required |
| Pan Dimensions (W×D) | 180 mm × 180 mm |
| Clear Height Above Pan | 150 mm |
| Overall Dimensions (W×D×H) | 238 mm × 335 mm × 287 mm |
| Interface | RS232 |
| Standard Accessories | In-use plastic draft shield, AC adapter, calibration certificate |
| Origin | Switzerland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | PM4800 |
| Warranty | 6 months |
| Operational Age | 3–4 years |
| Price Range | USD 1,400–7,000 (FOB) |
| Configuration | Fully Tested & Calibrated Unit with Original Accessories |
| Origin | Switzerland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | 780 Advanced |
| Pricing | Available Upon Request |
| Origin | Netherlands |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Metorex C100 |
| Detection Principle | Energy-Dispersive X-ray Fluorescence (EDXRF) |
| Portability | Fixed-Installation |
| Analyte | Total Sulfur |
| Measurement Range | 0.5 ppm to 10 wt% |
| Analysis Mode | Real-Time Continuous Monitoring |
| Detection Limit | 0.5 ppm (S, in liquid hydrocarbons) |
| Accuracy | Compliant with ASTM D4294 and ASTM D7212 |
| Regulatory Compliance | Designed for GLP/GMP environments |
| Origin | Switzerland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 702 Economy |
| Price | Upon Request |
| pH Range | 0 to ±20.00 |
| Potential Range | 0 to ±2000 mV |
| Current Range | 0 to ±200.0 µA |
| Temperature Range | −150.0 to +450.0 °C |
| Burette Volumes | 1, 5, 10, 20, or 50 mL |
| Burette Resolution | 1/10,000 of selected volume |
| Absolute Burette Error | ±0.02 mL (with 10 mL burette) |
| Relative Accuracy | ±0.2% (with 10 mL burette) |
| Input Impedance | >10¹³ Ω |
| Current Compensation | <3.1 × 10⁻¹³ A |
| Thermal EMF Compensation Drift | 15 µV/K |
| Electrode Inputs | 2 high-impedance measuring electrodes, 1 reference electrode, 1 polarizable electrode, 1 temperature sensor |
| Polarization Range | Current 0 to ±127 µA |
| Differential Amplifier | Optimized for low-conductivity non-aqueous titrations |
| Method Storage Capacity | 100 pre-programmed or user-defined methods |
| Dimensions (W × H × D) | 150 × 450 × 275 mm |
| Origin | Switzerland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | 719 SET Basic |
| Pricing | Available Upon Request |
| Origin | Switzerland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 744 |
| Pricing | Available Upon Request |
| Origin | Switzerland |
|---|---|
| Type | Imported Instrument |
| Model | 785 Universal |
| Pricing | Upon Request |
| Measurement Range | pH 0 to ±20.00 |
| Potential | ±2000 mV |
| Current | ±200.0 µA |
| Temperature | −150.0 to +450.0 °C |
| Burette Volumes | 1, 5, 10, 20, or 50 mL |
| Resolution | 1/10,000 of burette volume |
| Absolute Accuracy | ±0.02 mL (with 10 mL burette) |
| Relative Accuracy | ±0.2% (with 10 mL burette) |
| Input Impedance | >10¹³ Ω |
| Polarization Current | ±127 µA |
| Polarization Potential | ±1270 mV (10 mV steps) |
| Electrode Inputs | 2 high-impedance indicator electrodes, 1 reference electrode, 1 polarization electrode, 1 temperature sensor |
| Origin | Switzerland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 794 Standard |
| Price | Upon Request |
| pH Range | 0 to ±20.00 |
| Potential Range | 0 to ±2000 mV |
| Current Range | 0 to ±200.0 µA |
| Temperature Range | −150.0 to +450.0 °C |
| Burette Volumes | 1, 5, 10, 20, or 50 mL |
| Burette Resolution | 1/10000 of selected volume |
| Absolute Accuracy (10 mL burette) | ±0.02 mL |
| Relative Accuracy (10 mL burette) | ±0.2% |
| Input Impedance | >10¹³ Ω |
| Polarization Current | 0 to ±127 µA |
| Polarization Potential | 0 to ±1270 mV (10 mV steps) |
| Electrode Inputs | 2 high-impedance measuring electrodes, 1 reference electrode, 1 polarization electrode, 1 temperature sensor |
| Method Storage Capacity | 100 methods |
| Dimensions (W×H×D) | 150 × 450 × 275 mm |
| Origin | Switzerland |
|---|---|
| Titration Volume Options | 1, 2, 5, 10, 20, or 50 mL |
| pH Range | 0 to ±20.00 |
| Potential Range | ±2000 mV |
| Current Range | ±200.0 µA |
| Temperature Range | −150.0 to +450.0 °C |
| Titration Resolution | 1/10,000 of burette volume |
| Absolute Accuracy (10 mL burette) | ±0.02 mL |
| Relative Accuracy (10 mL burette) | ±0.2% |
| Input Impedance | >10¹³ Ω |
| Polarization Current | ±127 µA |
| Polarization Potential | ±1270 mV (10 mV steps) |
| Electrode Inputs | 2 high-impedance measuring, 1 reference, 1 polarization, 1 temperature sensor |
| Method Storage Capacity | 100 methods |
| Dimensions (W×H×D) | 150 × 450 × 275 mm |
| Origin | Switzerland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 800 |
| Pricing | Upon Request |
| Instrument Type | Electrochemical Sample Handler / Reagent Dispenser |
| Origin | Switzerland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 826 |
| Pricing | Upon Request |
| Origin | Switzerland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | 916s |
| Pricing | Available Upon Request |
| Origin | Netherlands |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | NOVA |
| Pricing | Available Upon Request |
| Origin | Switzerland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 827 |
| Pricing | Upon Request |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | AL104 |
| Readability | 0.1 mg |
| Maximum Capacity | 110 g |
| Repeatability (s) | 0.1 mg |
| Linearity | ±0.2 mg |
| Calibration | External, 100 g weight (optional) |
| Pan Diameter | Φ90 mm |
| Draft Shield Height | 220 mm |
| Dimensions (W×D×H) | 238 × 335 × 364 mm |
| Interface | RS232 |
| Compliance | ISO/IEC 17025–compatible operation, GLP/GMP-ready audit trail support via e-Loader II software |
| Key | Origin: Switzerland |
|---|---|
| Model | AL204 / AL104 |
| Readability | 0.1 mg |
| Max Capacity | 210 g (AL204) / 110 g (AL104) |
| Repeatability | 0.1 mg |
| Linearity | ±0.3 mg (AL204) / ±0.2 mg (AL104) |
| Pan Diameter | 90 mm |
| Draft Shield Height | 220 mm |
| Dimensions (W×D×H) | 238 × 335 × 364 mm |
| Calibration | External, with optional 100 g or 200 g weights |
| Interface | RS232 |
| Housing Material | Corrosion- and impact-resistant ABS engineering plastic |
| Standard Accessories | In-use protective cover, keypad with tactile feedback, backlit LCD display |
| Origin | Switzerland |
|---|---|
| Model | EM120 |
| Maximum Capacity | 124 g |
| Readability | 0.001 g / 0.01% |
| Pan Diameter | 90 mm |
| Repeatability | ±0.2% (1 g sample), ±0.02% (10 g sample) |
| Heating Source | Halogen lamp |
| Temperature Range | 30–230 °C |
| Temperature Increment | 1 °C |
| Heating Mode | Boost function (140% target temperature for first 3 min) |
| Termination Criteria | Automatic, semi-automatic (user-defined mass change per second), or time-based (0.1–240 min) |
| Data Output Interval | 0.1–10.0 min |
| Stored Methods | 5 user-defined profiles |
| Security | Password-protected settings, physical lock slot |
| Interface | RS232 |
| Firmware Update | Network-enabled via PC connection |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MF-830 |
| Pricing | Available Upon Request |