Generic
Filter
Showing 2101–2130 of 5744 results
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PG-300 |
| Instrument Type | Portable Flue Gas Analyzer |
| Measurement Accuracy | ≤5% of reading |
| Repeatability | ±1.0% F.S. |
| Response Time (T90) | ≤45 s (SO₂: ≤180 s) |
| Stability | ≤5% F.S. over 24 h |
| Zero Drift | ±1.0% F.S./day (SO₂: ±2.0% F.S./day) |
| Span Drift | ±1.0% F.S./day |
| Linearity Error | ±2.0% F.S. |
| Sample Flow Rate | ~0.5 L/min |
| Power Supply | 100–120 VAC / 200–240 VAC, 50/60 Hz |
| Operating Temperature | 5–40 °C |
| Relative Humidity | ≤85% RH (non-condensing) |
| Dimensions (W×H×D) | 226 × 265 × 510 mm |
| Weight | ~14 kg |
| Data Storage | SD card |
| Output Interfaces | 4–20 mA analog output, Ethernet |
| Warm-up Time | 30 min (±2.0% F.S. drift within 2 h) |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TIA-51d / TIA-51p |
| Pricing | Upon Request |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | UV-2500 (UV Absorption Method) & SDY (Electrochemical Oxidation Method) |
| Pricing | Available Upon Request |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | XGT-1000WR/1700WR |
| Pricing | Available Upon Request |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | XGT-1700 |
| Price Range | USD 42,000–70,000 |
| Instrument Type | Scanning |
| X-ray Tube Power | Not Applicable (Rh anode, max 50 kV / 1 mA) |
| Elemental Range | Na to U |
| Detection Limits | Cd ≤ 2 ppm, Pb ≤ 5 ppm, Cl ≤ 50 ppm |
| Sample Chamber Max Size | 460 × 360 × 150 mm |
| X-ray Beam Diameters | Φ1.2 mm and Φ3.0 mm (motorized switching) |
| Detector | High-Purity Silicon XEROPHY Detector |
| Liquid Nitrogen Capacity | 3 L |
| LN₂ Consumption | <1 L/day (only during operation) |
| Optical Magnification | 50× (coaxial with X-ray beam) |
| Software | Automated qualitative/quantitative analysis (fundamental parameters method, calibration curve method, single-point correction) |
| PC Requirements | Pentium IV ≥1.8 GHz, ≥1 GB RAM, ≥120 GB HDD, Windows XP, 17″ monitor, color inkjet printer |
| Ambient Temp | 10–35 °C (optimal), 5–40 °C (operational) |
| Humidity | ≤80% RH at 5–31 °C |
| Power Supply | AC 100/120/220/240 V ±10%, 50/60 Hz |
| Power Consumption | ≤1.3 kVA (system-wide) |
| Weight | ~265 kg (analysis unit only) |
| Dimensions | Analyzer Unit: 610(W) × 750(D) × 500(H) mm |
| Signal Processing Unit | 220(W) × 500(D) × 480(H) mm |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | XGT-5200 |
| Price Range | USD 42,000–70,000 (FOB) |
| Instrument Type | Scanning Micro-XRF |
| X-Ray Tube Power | 50 kV / 1 mA |
| Target Material | Rhodium (Rh) |
| Detectable Elements | Na (Z=11) to U (Z=92) |
| Primary Beam Spot Sizes | 10, 50, 100, 400 µm, 1.2 mm, 3 mm |
| Detector | Silicon Drift Detector (SDD) |
| Sample Stage | 100 × 100 mm (standard), up to 200 × 200 mm (optional) |
| Sample Chamber Dimensions | 400 × 350 × 40 mm (customizable) |
| Optical Imaging | Macro-view 100 × 100 mm (400K pixels standard |
| Analysis Modes | Qualitative (auto-identification, ROI color mapping, background subtraction, spectral matching) and Quantitative (Fundamental Parameters Method, calibration curve, Cl/thickness/wire compensation) |
| Data Export | Excel®-compatible reporting module |
| Power Supply | AC 100/120/220/240 V, 50/60 Hz |
| Weight | ~280 kg |
| Dimensions (W×D×H) | 680 × 833 × 670 mm |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | XGT-7200 |
| Price Range | USD 42,000 – 70,000 (FOB) |
| Instrument Type | Scanning Micro-XRF |
| X-ray Tube Power | Not Applicable (Microfocus Rh Target, Fixed Excitation) |
| Elemental Range | Na (11) to U (92) |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | XP-3110 |
| Price Range | USD 700–1,400 |
| Instrument Type | Portable |
| Detectable Gases | Combustible Gases (e.g., Methane, Propane, Butane, LPG, Town Gas) |
| Response Time | ≤45 s (T90) |
| Measurement Accuracy | ±5% of Full Scale |
| Measurement Ranges | 0–10% LEL and 0–100% LEL (auto-ranging) |
| Key | Origin: Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (PRC) |
| Model | Pull-Off |
| Instrument Type | Electromechanical Universal Testing Machine |
| Load Capacity | 10 kN |
| Load Cell Accuracy | ±0.01% FS |
| Force Measurement Accuracy | ±0.5% of reading |
| Test Speed Range | 0.001–300 mm/min |
| Effective Test Stroke | ≥200 mm |
| Power Supply | AC 220 V, 50/60 Hz |
| Dimensions (W×D×H) | 600 × 300 × 300 mm |
| Weight | ~40 kg |
| Key | Max. Load: 100 kg (customizable) |
|---|---|
| Frequency Range | 1–600 Hz / 1–3000 Hz / 1–5000 Hz |
| Sweep Range | 1–600 Hz / 1–3000 Hz / 1–5000 Hz |
| Peak-to-Peak Amplitude | 0–5 mm |
| Max. Acceleration | 20 g |
| Vibration Axes | Vertical (Z) + Horizontal (X/Y) |
| Waveform | Sine |
| Programmable Segments | 1–15 segments, each with user-defined frequency & duration, loopable |
| Octave Sweep Modes | 5-step logarithmic (low→high, high→low, low→high→low, repeatable) |
| Power Rating | 2.2 kW |
| Table Dimensions (L×W) | 500×500 mm (customizable) |
| Unit Dimensions (L×H×W) | Vertical unit: 500×200×500 mm |
| Horizontal unit | 500×250×500 mm |
| Input Voltage | 1φ AC 220 V, 50/60 Hz |
| Max. Current | 6 A |
| Frequency Resolution | 0.01 Hz, Accuracy: ±0.1 Hz |
| Table Mounting Pattern | Customizable M6/M8 threaded holes |
| Optional Accessories | Magnesium alloy fixtures, FEM-optimized fixtures, circular/square/octagonal extension tables, thermal isolation pads for environmental chamber integration |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 0130 |
| Price Range | USD 6,800 – 13,500 |
| Instrument Type | Manual Hydraulic Pellet Press |
| Compatible Pellet Diameters | 1 mm, 3 mm, 7 mm |
| Die Head Material | Stainless Steel (AISI 304) |
| Construction | Compact and Rugged Benchtop Design |
| Maintenance | Tool-Free Disassembly for Cleaning |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Hound-FR |
| Pricing | Available Upon Request |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | HP 5890 Series II |
| Detection Options | FID / TCD |
| Injection Options | SSI / PPI |
| Data System | Integrated GC Control & Analysis Software |
| Autosampler | HP 7673 |
| Origin | Hunan, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | HPA-300 |
| Price Range | USD 7,000–14,000 |
| Instrument Type | Heat Flow Method |
| Dimensions (L×W×H) | 750 × 650 × 1100 mm |
| Accuracy | ±3% |
| Thermal Conductivity Range | 0.015–100 W/(m·K) |
| Repeatability | ±1% |
| Maximum Test Temperature | 300 °C |
| Applied Load Range | 0–1000 N (adjustable) |
| Specimen Size | φ50 × 100 mm or φ37.5 × 100 mm |
| Cooling Base Temperature | 20 °C (integrated constant-temperature water bath) |
| Axial Temperature Sensors | 4 points |
| Radial Temperature Sensors | 3–6 gradient points |
| Heating Power | 60 W |
| Software | Fully Automated Acquisition & Analysis Suite with Touchscreen Interface |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | HPE-01 |
| Instrument Type | Automated Quantitative Concentrator |
| Rated Power | 1100 W |
| Temperature Control Range | Ambient +5 °C to 100 °C |
| Temperature Accuracy | ±1 °C |
| Rotational Speed | 50–420 rpm |
| Centrifugal Radius | 5 mm |
| Net Weight | 32 kg |
| Dimensions (W×D×H) | 490 × 320 × 355 mm |
| Sample Capacity | 24 positions, standard tube volume: 30 mL |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | HDG-04 / DG-03 / DG-02 |
| Price | USD 1,380 (FOB Shanghai) |
| Channels | 2 (HDG-02), 3 (DG-03), 4 (HDG-04) |
| Degassing Efficiency | ≤1.8 ppm O₂ at 1 mL/min, ≤4.0 ppm O₂ at 5 mL/min (inlet: 8 ppm O₂, 25°C) |
| Vacuum Pressure | −0.085 MPa (absolute) |
| Max Flow per Channel | 10 mL/min |
| Solvent Volume per Channel | 12 mL |
| Dimensions (W×D×H) | 150 × 340 × 180 mm |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Speed-Up Wafer-level Magnetic Test |
| Price | Upon Request |
| Origin | Germany |
|---|---|
| Supplier Type | Authorized Distributor |
| Import Status | Imported |
| Model | HPW Series |
| Pricing | Available Upon Request |
| Origin | Shanghai |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | HQH-300 / HQH-150 |
| Price | ¥18,800 |
| Temperature Control Range | 10–50 °C (with light), 4–50 °C (without light) |
| Temperature Uniformity | ±1 °C |
| Temperature Resolution | 0.1 °C |
| Humidity Range | 50–90 %RH |
| Humidity Deviation | ±5–7 %RH |
| Illumination Intensity | 0–20,000 lx (6-level adjustable) |
| Lighting System | Triple-side T4 fluorescent lamps |
| Power Input | 3000 W |
| Interior Dimensions (W×D×H) | 580×550×950 mm |
| Nominal Volume | 300 L |
| Standard Shelves | 3 pcs |
| Operating Ambient | 5–30 °C |
| Refrigerant | R134a / R406a (CFC-free) |
| Air Circulation | JAKEL centrifugal blower with optimized duct design |
| Control System | Microprocessor-based PID control with 99-cycle programmability (30 segments/cycle, up to 99 h 59 min/segment) |
| Interface Options | RS485 or USB (optional) |
| Safety Features | Over-temperature auto-shutdown with audible/visual alarm, dual-compressor alternation mode (optional), continuous operation ≥360 h |
| Origin | Beijing |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | HQJY |
| Quotation | Upon Request |
| Instrument Type | Soil Moisture / Water Potential Analyzer |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | HQNS-13 |
| Quotation | Upon Request |
| Instrument Type | Environmental Sediment & Runoff Analyzer |
| Flow Measurement Accuracy | ≤0.2% FS |
| Suspended Sediment Concentration (SSC) Accuracy | ≤3% FS |
| Sampling Interval | 2–99 min (configurable) |
| SSC Measurement Ranges | 0–30 kg/m³ (±0.3 kg/m³), 30–250 kg/m³ (±4 kg/m³), 0–1000 kg/m³ (±17 kg/m³) |
| Water Level Resolution | <0.1 cm |
| Max. Data Channels | 6 |
| Power Consumption | <5 W |
| Operating Temperature | 0–60 °C (non-freezing) |
| Storage | −40–80 °C |
| Standby Runtime on Battery Backup | 7 days |
| Communication | RS-232 local download |
| 堰Flow Computation Models | Preloaded Weir Hydraulics Library (e.g., V-notch, rectangular, compound weirs) |
| Data Storage | Onboard non-volatile memory (capacity supports ≥1 year at 15-min interval) |
| Sensor Configuration | Up to 12 SSC sensors or 6 flow + SSC sensor pairs |
| Origin | Hunan, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | HR/T20M |
| Quotation | ¥28,500 |
| Speed Range | 10,000–30,000 rpm |
| Centrifugation Class | Biomacromolecules |
| Maximum Capacity | 4 × 100 mL |
| Maximum Speed | 20,000 rpm |
| Dimensions | 710 × 630 × 350 mm |
| RCF Max | 27,700 × g |
| Temperature Range | −20 °C to +40 °C |
| Temperature Accuracy | ±1 °C |
| Timer Range | 0–99 h 59 min |
| Noise Level | ≤65 dB(A) |
| Power Supply | AC 220 V, 50 Hz |
| Total Power | 1.5 kW |
| Weight | 75 kg |
| Rotor Options | Fixed-angle (e.g., 12 × 1.5/2.0 mL, 6 × 50 mL), Horizontal (e.g., 4 × 10 mL, 12 × 10 mL), Microplate (2 × 2 × 48-well) |
| Acceleration/Deceleration Control | 9-step programmable |
| Drive System | Brushless frequency-controlled motor |
| Cooling System | Imported non-CFC refrigeration unit (R404a) |
| Safety Features | Triple-layer steel rotor chamber, imbalance detection, overtemperature protection, lid interlock, standby cooling, momentary spin function |
| Origin | Germany |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | HR63 |
| Pricing | Upon Request |
| Dimensions (L×W×H) | 1000 × 250 × 250 mm |
| Net Weight | 17 kg |
| Chamber Material | AISI 304 stainless steel (1.4301) |
| Working Chamber | Ø59 × 400 mm (~1 L volume) |
| Max Operating Temperature | 200 °C (programmable temperature controller) |
| Sample Capacity | ~400 g (powder) |
| Power Rating | 533 W @ 240 V |
| Vacuum Interface | 2 × DN63 (main), DN16 & DN25 (auxiliary) |
| Ultimate Vacuum | 1 × 10⁻⁴ mbar |
| Heating Source | Electric heating plate |
| Includes | Thermal insulation adapter, cooling tube, flange set (DN63 ×2, DN16, DN25), vacuum/gas line adapters, pressure/vacuum gauges, control unit with PID programming, temperature sensor, mounting hardware, and operation manual |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | HS-2 |
| Pricing | Upon Request |
| Instrument Type | Static Headspace Sampler |
| Sample Heating Range | 40–200 °C (±1 °C accuracy) |
| Valve Heating Range | 40–200 °C (±1 °C) |
| Transfer Line Heating Range | 40–200 °C (±1 °C) |
| Sampling Time | 0–20 min |
| Pressurization Time | 0–30 s |
| Loop Volume | 1 mL |
| Vial Capacity | 10 mL or 20 mL vials |
| Sample Position Capacity | 10 positions |
| RSD | ≤1.5% (measured in 200 ppm ethanol in water) |
| Power Consumption | 220 W |
| Dimensions (W×H×D) | 500×180×400 mm |
| Net Weight | ~15 kg |
| Origin | Tianjin, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | HS-W-B (400–1000) |
| Price Range | USD 42,000 – 70,000 |
| Spectral Range | 400–1000 nm |
| Spectral Resolution | ≤5 nm |
| Sampling Interval | <3 nm |
| Number of Spectral Channels | 300 |
| Light Source | Integrated Halogen Lamp |
| Measurement Frequency | Configurable, up to 1 measurement per 5 seconds |
| Detection Accuracy | >85% (vs. Standard Laboratory Methods) |
| Power Supply | Rechargeable Lithium Battery / Solar Panel / AC Mains |
| Operational Duration | ≥6 months (at 30-min sampling interval) |
| Dimensions | 70 cm × 20 cm × 32 cm |
| Weight | <20 kg (including buoy assembly) |
| Communication Interface | 4G/5G Cellular Module |
| Ingress Protection Rating | IP67 |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | HS.Z68-10 |
| Power Rating | 7.5 kW, 380 V AC |
| Output Capacity | 10 L/h |
| Construction Material | AISI 304 Stainless Steel |
| Safety Features | Automatic dry-run protection with audible alarm and auto-refill restart |
| Indicators | LED status indicators for power, heating, and low-water condition |
| Compliance | Designed to meet general laboratory safety and electrical standards per GB/T 12801–2022 (Basic Requirements for Safety in Production Processes) and IEC 61010-1:2010 (Safety Requirements for Electrical Equipment for Measurement, Control, and Laboratory Use) |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HS.Z68-20 |
| Power Rating | 15 kW, 380 V AC |
| Output Capacity | 20 L/h |
| Construction Material | AISI 304 Stainless Steel |
| Safety Features | Auto shut-off with low-water alarm, auto-refill & restart function |
| Indicators | Power ON, Heating Active, Low-Water Status |
| Compliance | Designed for GLP-compliant laboratory environments per ISO 6425 and ASTM D1193 Type IV water specifications |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | HS.Z68-5 |
| Power Rating | 5 kW |
| Voltage | 220 V AC |
| Distillate Output | 5 L/h |
| Construction Material | AISI 304 Stainless Steel |
| Safety Features | Automatic Dry-run Protection with Audible Alarm and Auto-refill Restart |
| Indicators | Power On, Heating Active, Low-Water Status |
| Compliance | Designed to meet general laboratory-grade water purification requirements per GB/T 6682–2008 (China National Standard for Water for Analytical Laboratory Use) |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | HS5628 |
| Price Range | USD 280–700 |
| Frequency Range | 20 Hz–10 kHz |
| Sound Pressure Level Range | 30 dB(A) to 130 dB(A) |
| Frequency Weighting | A, C |
| Time Weighting | Fast (F), Slow (S) |
| Detector | Digital True RMS with Peak Factor ≥ 3 |
| Dynamic Range per Range | ≥ 60 dB (High/Mid/Low 3-range auto-switching) |
| Measurement Duration Options | 10 s, 1 min, 5 min, 10 min, 15 min, 20 min, 30 min, 1 h, 8 h, 24 h, Manual |
| Metrics Calculated | L<sub>p</sub>, L<sub>eq</sub>, L<sub>AE</sub>, SD, L<sub>max</sub>, L<sub>min</sub>, E (Sound Exposure) |
| Display | 8×2 dot-matrix LCD |
| AC Output | Yes |
| Power Supply | 2 × AA alkaline batteries |
| Dimensions (L×W×H) | 200 × 62 × 30 mm |
| Mass | 200 g (including batteries) |
| Operating Temperature | –10 °C to +50 °C |
| Relative Humidity Range | 20%–90% RH (non-condensing) |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | HS5633 |
| Price Range | USD 140–280 |
| Frequency Range | 31.5 Hz – 8 kHz |
| Measurement Range | 35 dB(A) – 130 dB(A) |
| Frequency Weighting | A-weighting, C-weighting |
| Time Weighting | Fast (F) |
| Display | 2-line alphanumeric LCD with backlight |
| Output | AC & DC analog outputs |
| Power Supply | 1 × 9 V alkaline battery |
| Dimensions | 230 × 72 × 30 mm |
| Mass | 200 g |
| Compliance | GB/T 3785–2010 Class 2, IEC 61672-1:2013 Class 2 |