Gerber
Filter
Showing all 21 results
| Brand | GERBER |
|---|---|
| Origin | Germany |
| Model | ColonyStar |
| Instrument Type | Fully Automated Colony Counter |
| Magnification | 2× |
| Display | 5-digit LCD (0–99999) |
| Counting Area Diameter | 145 mm |
| Resolution | 0.1 cm² |
| Dimensions (L×W×H) | 250 mm × 230 mm × 95 mm |
| Weight | 1.5 kg |
| Base Options | Black or White Contrast Background |
| Counting Speed | Adaptive to colony density (typical range: 1–5 s per Petri dish under standard conditions) |
| Brand | Gerber |
|---|---|
| Origin | Switzerland |
| Model | Cryoscope C1 |
| Measurement Range | 0 to −1000 m°C/m°H |
| Display Resolution | 0.1 m°C/m°H |
| Repeatability | ±2 m°C/m°H (1S.D.) |
| Sample Volume | 2.0–2.5 mL |
| Measurement Time | ~90 s (Rapid Mode: ~30 s) |
| Operating Ambient Temperature | 15–35 °C |
| Relative Humidity | 5–80 % RH |
| Power Supply | 110–240 V, 50/60 Hz |
| Power Consumption | 90 W |
| Dimensions (W×D×H) | 28 × 42 × 32 cm |
| Net Weight | 11 kg |
| Gross Weight | 15 kg |
| Brand | GERBER |
|---|---|
| Origin | Germany |
| Model | CryoStar Automatic |
| Accuracy | ±0.0001 °C |
| Repeatability | ±0.002 °C |
| Measurement Range | −1.5000 °C to 0.0000 °C |
| Sample Volume | 2.0–2.5 mL |
| Throughput | 40 samples/hour |
| Dimensions (W×H×D) | 44×44×20 cm |
| Test Head Height | 24 cm |
| Net Weight | 14.6 kg |
| Power Supply | 230 V, 50–60 Hz, 180 W + 12 V DC |
| Interface | RS232 |
| Sample Capacity | 12-position automated carousel |
| Compliance | ISO/DIS 5764 |
| Brand | Gerber |
|---|---|
| Origin | Germany |
| Model | CryoStar I |
| Measurement Range | 0.000 to −1.5000 °C |
| Accuracy | ±0.0001 °C (0.1 m°C) |
| Repeatability | ±0.002 °C |
| Sample Throughput | up to 40 samples/hour (typ. 30/h) |
| Sample Volume | 2.0–2.5 mL |
| Cooling Time to Operating Temperature | ≤15 min |
| Display | Full-color LCD touchscreen |
| Data Output | Ice point curve, ice point value, water adulteration %, timestamp, operator ID, calibration status, error codes |
| Interfaces | RS232, dual USB ports (U-drive data export supported) |
| Power Supply | 220 V / 50 Hz, 180 W |
| Dimensions (W×D×H) | 29 × 33 × 34 cm |
| Weight | 8.7 kg |
| Brand | GERBER |
|---|---|
| Origin | Germany |
| Model | CryoStar I |
| Measurement Range | 0.0000 to −1.5000 °C |
| Resolution | 0.0001 °C (0.1 m°C) |
| Accuracy | ±0.002 °C (repeatability) |
| Sample Volume | 2.0–2.5 mL |
| Throughput | up to 40 samples/hour (typical: 30 samples/hour) |
| Cooling Time | ≤15 min to operational temperature |
| Display | Full-color LCD touchscreen |
| Data Interfaces | RS232, 2× USB (U-disk data export) |
| Power Supply | 220 V / 50 Hz, 180 W |
| Dimensions | 29 × 33 × 34 cm |
| Weight | 8.7 kg |
| Brand | GERBER |
|---|---|
| Origin | Germany |
| Model | CryoStar I |
| Measurement Range | 0.000 to −1.5000 °C |
| Resolution | 0.0001 °C (0.1 m°C) |
| Repeatability | ±0.002 °C |
| Sample Throughput | up to 40 samples/hour (typical: 30 samples/hour) |
| Sample Volume | 2.0–2.5 mL |
| Cooling Time to Operating Temperature | ≤15 min |
| Display | Full-color LCD touchscreen |
| Data Output | Ice-point curve, ice-point value, water adulteration percentage, timestamp, operator ID, calibration status, error codes |
| Interfaces | RS232, two USB ports (U-disk data export supported) |
| Power Supply | 220 V / 50 Hz, 180 W |
| Dimensions (W×D×H) | 29 × 33 × 34 cm |
| Weight | 8.7 kg |
| Brand | Gerber |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | FermentoFlash |
| Instrument Type | Beer-Specific Analyzer |
| Application | Laboratory Use |
| Analysis Time | ≤2 min (including sample loading) |
| Alcohol Content Range | 0.00–15.00 % v/v |
| Apparent Extract Range | 0.00–10.00 % w/w |
| Original Wort Range | 0.00–20.00 % w/w |
| Alcohol Extraction Range | 0.00–10.00 % w/w |
| Repeatability (Alcohol) | ±0.02 % v/v |
| Repeatability (Extract & Original Wort) | ±0.04 % w/w |
| Dimensions (W × H × D) | 30 × 24 × 33 cm |
| Weight | 5 kg |
| pH Measurement | Not applicable — device does not measure pH (parameter misattributed in source |
| Brand | GERBER |
|---|---|
| Origin | Germany |
| Model | Flash |
| Instrument Type | Beer-Specific Analyzer |
| Application | Laboratory |
| Throughput | 40 samples/hour |
| Alcohol Content Range | 0–15% v/v |
| pH Range | 0–15 |
| Dimensions (W×H×D) | 40 × 20 × 26 cm |
| Weight | 10 kg |
| Sample Volume | 18 mL |
| Measurement Accuracy | ±0.01% for alcohol and extract parameters |
| Interface | RS-232 standard port |
| Data Output | Printer-compatible, PC-integrated |
| Brand | Gerber |
|---|---|
| Origin | Germany |
| Model | LactoFlash |
| Automation | Fully Automatic |
| Analysis Speed | 120 samples/hour |
| Measurement Range | Fat 0.01–30.00% |
| Density | ≥0.0001 g/cm³ resolution |
| Freezing Point Depression | ±0.001 °C resolution |
| Repeatability | ±0.02–±0.2% depending on analyte and concentration range |
| Accuracy | ±0.01% for fat, protein, lactose, and non-fat solids |
| Sample Volume | 12–20 mL (adjustable) |
| Power Supply | 230 V / 115 V, 50/60 Hz, 60 W |
| Dimensions | 30 × 24 × 33 cm (W×H×D) |
| Weight | 5 kg |
| Interface | RS-232 serial port |
| Compliance | Designed to support ISO 9001-aligned QA workflows and routine GLP-compliant dairy testing |
| Brand | Gerber |
|---|---|
| Origin | Germany |
| Model | LactoStar |
| Automation | Fully Automatic |
| Analysis Speed | ≥40 samples/hour |
| Measurement Range | Fat 0–35%, Protein 0–10%, Lactose 0–10%, Non-Fat Solids 0–15%, Minerals 0–5%, Freezing Point Depression –0.001 °C |
| Repeatability | ±0.002% (w/w) |
| Accuracy | ±0.001% (w/w) |
| Sample Volume | 12 mL |
| Calibration Storage | Up to 20 user-defined calibration profiles |
| Interface | RS-232 serial port |
| Data Output | Integrated thermal printer support |
| Brand | GERBER |
|---|---|
| Origin | Germany |
| Model | Nova Safety |
| Max Speed | 1350 rpm |
| Relative Centrifugal Acceleration (RCF) | 350 × g |
| Capacity | 8 tubes |
| Temperature Control | 65 °C (heated) |
| Timer | Digital display |
| Safety Features | Automatic lid lock, electronic brake (<8 s stop time) |
| Dimensions (L×W×H) | 470 × 380 × 230 mm |
| Weight | 13.2 kg |
| Voltage | 230 V, 50 Hz |
| Power | 450 W |
| Brand | GERBER |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | NOVA-SAFETY |
| Speed | 1350 rpm |
| Relative Centrifugal Acceleration (RCF) | 350 × g |
| Heating Temperature Control | 65 °C ± 1 °C |
| Capacity | 8 tubes (10–12 mL Gerber-specific centrifuge tubes) |
| Safety Lock | Automatic lid interlock with force-sensing engagement |
| Brake Time | < 8 s after rotor stop command |
| Timer | Digital, adjustable 0–30 min in 1-sec increments |
| Compliance | Designed to meet ASTM D943, ISO 1735, and IDF Standard 102 for Gerber fat determination |
| Brand | Gerber |
|---|---|
| Origin | Germany |
| Model | SEDILAB-E |
| Application | Milk and Dairy Product Sediment Analysis |
| Automation Level | Fully Automatic |
| Sample Throughput | 800 samples/hour |
| Sample Volume per Test | 500 mL |
| Sediment Disc Diameter | 32 mm |
| Repeatability | Grade-based Classification (per ISO 707 & IDF 50) |
| Compliance | Designed for ISO, IDF, and national dairy quality standards |
| Brand | Gerber |
|---|---|
| Origin | Germany |
| Model | SoluStar 7640 |
| Standard Compliance | IDF 129, ISO 8156 |
| Rotational Speed Range | 1,000–4,000 rpm (adjustable in 10 rpm increments) |
| Fixed setting | 3,600 rpm |
| Stirring Duration | 1–599 s (adjustable) |
| Default setting | 90 s |
| Safety Interlock | Magnetic door switch with transparent safety cover |
| Vessel Handling | Motorized vertical lift and height adjustment for 500 mL borosilicate glass stirring cup |
| Impeller | 16-blade stainless steel, clockwise rotation, blades oriented with flat side downward and upward tilt from right to left |
| Dimensions (W × D × H) | 16.5 × 20.5 × 44.5 cm |
| Weight | 5 kg |
| Power Supply | 220 V, 50 Hz |
| Max. Power Consumption | 43 W |
| Brand | GERBER |
|---|---|
| Origin | Germany |
| Model | Solution Index Mixer |
| Motor Speed | 2800 rpm (drive), 3600 rpm (impeller) |
| Impeller | 16-blade stainless steel, clockwise rotation, flat side down, upward tilt from right to left |
| Vessel | 500 mL borosilicate glass beaker |
| Standards Compliance | ADPI, DLG, DIN ISO 8156 |
| Dimensions | 38 × 26 × 25 cm |
| Power | 65 W (220 V, 50 Hz) |
| Brand | GERBER |
|---|---|
| Origin | Germany |
| Model | Super-Vario-N |
| Max Speed | 1130 rpm |
| Speed Adjustment | 10 rpm increments (600–1130 rpm) |
| Heating Range | Ambient to 68 °C (1 °C increments) |
| Timer Range | 1–99 min |
| Chamber Material | Stainless steel |
| Safety Features | Automatic lid lock and brake system |
| Sample Capacity | 12 samples per run (Schmidt-Lewandowsky / solubility method) |
| Compliance | Designed for Gerber, Mojonnier, Babcock, and solubility fat determination methods |
| Brand | Gerber |
|---|---|
| Origin | Germany |
| Model | SUPER-VARIO-N |
| Max Speed | 1130 rpm |
| Speed Adjustment | 10 rpm increments (600–1130 rpm) |
| Heating Range | Ambient to 68 °C (1 °C increments) |
| Timer Range | 1–99 min |
| Chamber Material | Stainless Steel |
| Safety Features | Automatic lid lock and brake system |
| Sample Capacity | 12 positions for Mojonnier and solubility methods |
| Compliance | Designed for ASTM D129, ISO 1735, IDF 14, and AOAC 923.04 dairy fat determination protocols |
| Brand | Gerber |
|---|---|
| Origin | Germany |
| Model | TDT |
| Standards Compliance | DIN ISO 8967, ISO 3953, ISO 8460, ISO 9161, ISO 787-11, ASTM D4164, ASTM D4781, ASTM B527, USP <616> Method I, IDF 134 |
| Predefined Programs | 5 |
| Tap Count Range | 5–9995 cycles |
| Tap Rate | 250 taps/min |
| Tap Amplitude | 3 mm |
| Included Accessory | 250 mL calibrated graduated cylinder |
| Category | Food Quality Detector for Powder Bulk Density and Tap Density Measurement |
| Brand | GERBER |
|---|---|
| Origin | Switzerland |
| Model | Universal |
| Speed Range | 200–1100 rpm (fixed 1300 rpm option available) |
| Temperature Control | Up to 65 °C (heating only) |
| Timer Range | 0–255 minutes |
| Sample Capacity | 12 positions for Mohr and solubility methods |
| Method Selection | Gerber, Mohr, Babcock, and solubility methods |
| Safety Features | Automatic lid lock, electronic braking, imbalance detection and auto-shutdown |
| Compliance | Designed for routine dairy and food quality control per ISO 8570, IDF 128, AOAC 920.132, and FDA Grade A standards |
| Brand | Gerber |
|---|---|
| Origin | Germany |
| Model | WB 436-D |
| Bath Volume | 16 L |
| Temperature Range | Ambient to 99 °C |
| Temperature Stability | ±0.3 °C (at 37 °C, steady state) |
| Circulation | Internal & External Pump |
| Power | 1000 W |
| Voltage/Frequency | 230 V / 50–60 Hz |
| Display | 4-digit LED |
| Timer Range | 1–99 min |
| Dimensions (L×W×H) | 396 × 331 × 265 mm |
| Weight | 10.1 kg |
| Construction | Stainless Steel Inner & Outer Chamber |
| Overheat Protection | Dual-stage thermal cutoff |
| Recommended Fluid | Distilled Water |
| Brand | Gerber |
|---|---|
| Model | WYA-2W |
| Measurement Range | nD 1.3000–1.7000 |
| Accuracy | ±0.0002 (nD), ±0.1% (Brix) |
| Temperature Display Range | 0–50 °C (0.1 °C resolution) |
| Mass | 10 kg |
| Interface | RS-232 serial port for data output |