| Brand | Hach |
|---|---|
| Origin | USA |
| Manufacturer | Hach Company |
| Product Type | Online TOC Analyzer |
| Model | 8653700 |
| Detection Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Oxidation Method | UV/Persulfate with Optional Hydroxyl Radical Enhancement |
| Measurement Range | 0–100 µg C/L and 0–2000 µg C/L (Auto-Ranging) |
| Accuracy | ±10 µg C/L or ±3% of reading (whichever is greater) |
| Resolution | 0.001 ppb C |
| Detection Limit | <10 µg C/L |
| Repeatability | ±10 µg C/L or ±2% of reading (whichever is greater) |
| Carrier Gas Options | High-Purity Oxygen (for enhanced oxidation) or Instrument Air (for standard operation) |
| Sample Pathway | Integrated 4-mm ID flow cell, no pretreatment required |
| Reagent-Free Operation | No alkaline reagents used in CO₂ detection pathway |
| Brand | Hach |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | 8653800 |
| Instrument Type | Online TOC Analyzer |
| Detection Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Oxidation Method | UV/Persulfate with Hydroxyl Radical Enhancement (O₂ carrier gas mode) or UV/Persulfate alone (instrument air carrier gas mode) |
| Operating Temperature Range | 5–45 °C |
| Accuracy | ±0.5 mg C/L or ±3% of reading (whichever is greater) |
| Resolution | 0.5 mg C/L |
| Detection Limit | >0.5 mg C/L |
| Repeatability | TOC: ±0.5 mg C/L or ±2% of reading (whichever is greater) |
| TIC | ±4% of reading |
| Sample Pathway | 4 mm ID integrated flow cell, no pretreatment required |
| Brand | HACH |
|---|---|
| Origin | Imported |
| Manufacturer | HACH Company |
| Model Numbers | 8653600, 8651600 |
| Instrument Type | Online TOC Analyzer |
| Detection Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Oxidation Method | UV/Persulfate Oxidation |
| Measurement Range | 0–25 mg C/L to 0–100 mg C/L (Auto-ranging) |
| Accuracy | ±0.5 mg C/L or ±3% of reading (whichever is greater) |
| Resolution | 0.5 mg C/L |
| Detection Limit | 0.5 mg C/L |
| Repeatability | TOC: ±0.5 mg C/L or ±2% of reading (whichever is greater) |
| TIC | ±4% of reading |
| Brand | HACH |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Instrument Type | Online TOC Analyzer |
| Model | QL3580M |
| Detection Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Oxidation Method | UV/Persulfate with Hydroxyl Radical Enhancement |
| Measurement Range | 0–10 mg C/L |
| Accuracy | ±3% of reading or ±0.05 mg C/L (whichever is greater) |
| Resolution | 0.5 mg C/L |
| Detection Limit | 0.5 mg C/L |
| Repeatability | ±2% of reading or ±0.05 mg C/L (whichever is greater) |
| Brand | HACH |
|---|---|
| Origin | Imported |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Laboratory-Based TOC Analyzer |
| Model | QP1680 TOC Analyzer |
| Oxidation Method | High-Temperature Catalytic Combustion (680 °C) |
| Detection Principle | Non-Dispersive Infrared (NDIR) Detection of CO₂ |
| Measurement Range | 0.5–30,000 µg/L (ppb to ppm) as C |
| Detection Limit | ≤0.5 µg/L (ppb) as C |
| Sample Throughput | Up to 60 samples per hour with autosampler |
| Compliance | ASTM D5997, USP <643>, EP 2.2.44, ISO 8245, and compliant with FDA 21 CFR Part 11 requirements for electronic records and signatures |
| Brand | Hach |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model(s) | QP1680-TOC, QP1680-TOC/TN, QP1680-TN |
| Instrument Type | Laboratory TOC/TN Analyzer |
| Detection Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Oxidation Method | High-Temperature Catalytic Combustion |
| Measurement Range | TC, TIC, NPOC, TN: 0–30,000 mg/L |
| Detection Limits | TC/TIC/NPOC > 50 µg/L |
| Resolution | Particles ≤ 800 µm |
| Repeatability | < 5% (0–10 mg/L) |
| Brand | HACH |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | Rocksand |
| Detection Principle | High-Definition X-Ray Fluorescence (HDXRF) |
| Sample Forms | Solid, Powder, Slurry, Filtered Liquid |
| Operating Modes | Handheld, Tripod-Mounted, Quantitative Benchtop |
| Key Elements Detected | As, Cd, Cr, Cu, Hg, Ni, Pb, Zn, and up to 40 elements total |
| Detection Limits | Sub-ppm (µg/g) range for key heavy metals in soil matrices |
| Compliance | Designed for ASTM D6988, EPA Method 6200, ISO 18587, and CLP/RCRA screening workflows |
| Software | Pre-loaded regulatory decision logic with real-time exceedance alerts |
| Data Management | GLP-compliant audit trail, CSV/PDF export, cloud-sync capable |
| Weight | <3.5 kg (instrument only) |
| Power | Rechargeable Li-ion battery (≥8 hrs continuous operation) |
| Brand | HACH |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | SC100 |
| Pricing | Available Upon Request |
| Brand | HACH |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | SC1000 |
| Operating Temperature | -20–55°C, 0–95% RH (non-condensing) |
| Storage Temperature | -20–70°C, 0–95% RH (non-condensing) |
| Power Supply | 100–230 VAC, 50/60 Hz |
| Display | 1/4 VGA color TFT touchscreen with backlight |
| Relays | 4 × SPDT |
| Analog Outputs | 4–20 mA (max. 500 Ω load, up to 12 expandable) |
| Analog Inputs | 12 × 4–20 mA (500 Ω max. per channel) |
| Digital Communications | Modbus RTU (RS-485 & RS-232), PROFIBUS DP, Ethernet (standard), GSM cellular module option |
| Brand | Hach |
|---|---|
| Origin | USA |
| Model | SC1000 |
| Operating Temperature | -20 to 55 °C |
| Storage Temperature | -20 to 70 °C |
| Relative Humidity | 0–95% RH (non-condensing) |
| Power Supply | 100–230 VAC, 50/60 Hz |
| Display | 1/4 VGA backlit TFT color touchscreen |
| Relay Outputs | 4 × SPDT |
| Analog Outputs | 4–20 mA (up to 12 channels, 500 Ω max load) |
| Analog Inputs | 12 × 4–20 mA (500 Ω max input impedance) |
| Digital Communication | MODBUS RTU (RS485 & RS232), PROFIBUS DP, Ethernet service port, optional GSM cellular module |
| Sensor Connectivity | Up to 8 digital sensors per probe module |
| Enclosure Rating | IP65 (panel-mounted display module) |
| Brand | Hach |
|---|---|
| Origin | USA |
| Model | SC200 |
| Input Types | Dual digital (Hach Digital Sensor Protocol) and/or analog (4–20 mA, 0–20 mA, mV) sensor inputs |
| Communication Protocols | MODBUS RTU (RS232/RS485), Profibus DPV1 (optional) |
| Display | 240 × 160 pixel graphical LCD with LED backlight |
| Enclosure Rating | NEMA 4X / IP66 |
| Power Supply | 100–240 VAC ±10%, 50/60 Hz or 24 VDC (−15% / +20%) |
| Operating Temperature | −20 to 60 °C |
| Housing Material | Polycarbonate front, powder-coated aluminum and stainless steel chassis |
| Mounting Options | Wall, pole, or panel mount |
| Output Signals | Two independent 4–20 mA outputs (max. 500 Ω load) |
| Relay Outputs | Four SPDT relays (5 A, 250 VAC, 1200 W) |
| Data Storage | Flash memory with password-protected SD card slot |
| Certifications | CE (EMC: EN 50081-2, immunity: EN 61000-6-2), UL 61010-1, ETL Listed |
| Brand | Hach |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | SC200 Universal Controller |
| Instrument Type | Online Water Quality Analyzer |
| Measurable Parameters | pH, Conductivity, Turbidity, Dissolved Oxygen (DO), Flow |
| Communication Protocols | MODBUS RTU (RS232/RS485), Profibus DPV1 (optional), HART |
| Display | 240 × 160 pixel graphical LCD with LED backlight |
| Input Options | Dual digital sensor inputs, dual analog (4–20 mA) inputs, or hybrid digital + analog configurations |
| Output | Two independent 4–20 mA outputs (500 Ω load) |
| Enclosure Rating | NEMA 4X / IP66 |
| Operating Temperature | –20 to 60 °C |
| Power Supply | 100–240 VAC ±10%, 50/60 Hz or 24 VDC (–15% / +20%) |
| Weight | 1.70 kg |
| Certifications | CE (EMC: EN 50081-2, Immunity: EN 61000-6-2), UL, ETL |
| Brand | HACH |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | SC4500 |
| Display | 3.5" TFT capacitive color touchscreen |
| Operating Temperature | −20–60°C (8 W AC / 9 W DC sensor load) or −20–45°C (28 W AC / 20 W DC sensor load) |
| Storage Conditions | −20–70°C, 0–95% RH non-condensing |
| Sensor Channels | Dual-channel for SC-series sensors |
| Relays | 2 SPDT relays (0.75–1.5 mm² / 18–16 AWG) |
| AC | 100–240 VAC, 5 A resistive / 1 A pilot |
| DC | ≤42 VDC, 4 A resistive / 1 A pilot |
| Analog I/O | Up to 5 × 0–20 mA or 4–20 mA outputs per module |
| Digital Communication Options | Modbus RS485, Profibus DPV1, Modbus TCP, PROFINET IO, EtherNet/IP |
| USB Port | For firmware update and data export |
| Data Storage | ~20,000 records |
| Enclosure Rating | UL 50E Type 4X, IEC/EN 60529 IP66, NEMA 250 Type 4X, corrosion-resistant metal housing |
| Power Supply | AC 100–240 VAC ±10%, 50/60 Hz, 1 A (28 W load) |
| Dimensions | 144 × 144 × 192 mm |
| Weight | 1.7 kg (controller only) |
| Certifications | CE, ETL, UL, CSA |
| Brand | Hach |
|---|---|
| Model | SDI-12 |
| Measurement Principle | ASTM D4189-95 (Constant Pressure Filtration) |
| Channel Configuration | Single-Channel (Configurable up to 4 Channels) |
| Calibration & Maintenance | Auto-calibration and auto-cleaning cycles |
| Compliance | ASTM D4189-95, ISO 15714:2016 (Water quality — Determination of silt density index), GLP/GMP-ready data logging |
| Application Environment | Industrial feed water monitoring for UF/RO systems, including high-salinity variants (seawater-grade option available) |
| Output Interface | 4–20 mA analog + Modbus RTU/TCP |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Enclosure Rating | IP65 |
| Brand | HACH |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | sensION+ Benchtop pH Meter |
| Instrument Type | Benchtop |
| Parameter Types | Multi-parameter |
| Measurement Accuracy | ±0.1 pH |
| Measurement Range | 0–14 pH |
| Resolution | 0.1 pH |
| Display Precision | 0.001 pH |
| Calibration Solutions | User-Defined |
| Brand | HACH |
|---|---|
| Origin | Imported |
| Manufacturer | HACH Company |
| Model | sensION+ DO6 |
| Instrument Type | Portable |
| Measurement Principle | Polarographic Electrochemical Probe |
| Range | 0.00–20.00 mg/L (or 0–200% saturation) |
| Accuracy | ±0.2 mg/L |
| Repeatability | ±0.05% of reading |
| Detection Limit | 0–2 ppb (dissolved oxygen in ultrapure water mode, with zero-current measurement capability) |
| Enclosure Rating | IP67 |
| Keypress Durability | >6 million cycles |
| Brand | Hach |
|---|---|
| Model | sensION+ MM156 |
| Type | Portable / Handheld Multiparameter Water Quality Analyzer |
| Measurement Parameters | pH, Electrical Conductivity, Dissolved Oxygen (DO), Temperature |
| Enclosure Rating | IP67 |
| Probe | Integrated sensION+ 5049 Multiparameter Sensor Cartridge |
| Sensor Replaceability | Individual sensor modules (pH, conductivity, DO) |
| Probe Housing Material | Polycarbonate |
| Probe Dimensions | 40 mm × 170 mm |
| Electrode Configuration | Gel-filled pH electrode, Platinum-coated conductivity cell with integrated 30 kΩ thermistor, Polarographic DO sensor with replaceable membrane |
| Connector Coding | Color-coded (blue = DO, green = conductivity, black = pH) |
| Display | Backlit graphical LCD with icon-based interface |
| Operation | Single-hand ergonomic design |
| Data Handling | Auto-stabilization, on-screen parameter correlation, real-time temperature compensation |
| Accessories Included | Rugged carrying case (doubles as field workstation), calibration/storage kit, spare membranes, buffer solutions, cleaning tools |
| Compliance | Designed for field deployment under ASTM D1129, ISO 7888, ISO 5814, and USP <643> guidelines |
| Brand | Hach |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | sensION+ MM378 |
| Instrument Type | Laboratory Water Quality Analyzer |
| Measurement Parameters | pH, ORP (mV), ISE, Conductivity, Dissolved Oxygen (DO) |
| Dual-Channel Architecture | Channel 1 (pH/ORP/ISE/Conductivity), Channel 2 (DO) |
| GLP Compliance | Yes |
| Data Storage Capacity | 400 measurement records |
| Temperature Compensation | Automatic (NTC or Pt1000), Electrode Isoelectric Point Detection Supported |
| Software Integration | LabCom PC Software (optional, bidirectional control) |
| Accessories Included | pH electrode, conductivity electrode, polarographic DO probe, magnetic stirrer (dual-control capable), electrode stand, base, beakers, and calibration accessories |
| Brand | HACH |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Instrument Type | Benchtop pH Meter |
| Parameter Types | Multi-parameter (pH, mV, Temperature) |
| Measurement Range | pH: −2.000 to 19.990 |
| Temperature | −20 to 150 °C |
| mV | ±2000 |
| Resolution | pH: 0.1 / 0.01 / 0.001 |
| Temperature | 0.1 °C |
| mV | 0.1 / 1 |
| Accuracy | pH: ±0.001 |
| Temperature | ±0.1 °C |
| mV | ±0.1 mV |
| Calibration Points | 1–13 (auto/manual) |
| Data Storage | 400 readings |
| Temperature Compensation | Automatic or Manual |
| Connectivity | RS232 |
| IP Rating | IP54 |
| GLP Compliance | Yes |
| Power Supply | External AC/DC adapter (20 VAC / 12 VDC, 3.3 W) |
| Brand | HACH |
|---|---|
| Model | sensION+ |
| Device Type | Portable Electrochemical Meter |
| Enclosure Rating | IP67 |
| Display | 50 × 66 mm LCD (46 × 62 mm active area) |
| Power Supply | 3 × AA alkaline batteries (1.5 V each) |
| Battery Life | >1000 hours |
| Keypad | 5 sealed membrane keys (PET with protective coating), rated for 6 million actuations |
| Connector Types | MP-5 (IP67, for pH1, EC5, DO6 electrodes) and MP-8 (IP67, for MM110, MM150 electrodes) |
| Measurement Modes | Stable-read and Continuous-read |
| Electrode Health Indicator | On-screen elapsed measurement time display |
| Language Support | English, Spanish, French, Portuguese, Chinese |
| Compliance | Designed for field-deployable electrochemical measurements per ASTM D1293 (pH), ASTM D1129 (conductivity), ASTM D888 (dissolved oxygen), and ISO 7888 (conductivity), with full traceability support for GLP/GMP environments |
| Brand | HACH |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Instrument Type | Multiparameter |
| Parameter Types | pH, mV, Temperature |
| Measurement Accuracy | ±0.1 pH |
| Resolution | 0.01 pH |
| Measurement Range | 0–14 pH |
| Calibration Options | Custom buffer recognition (up to 5-point calibration) |
| Environmental Rating | IP67 |
| Display | Backlit LCD with intuitive menu navigation |
| Keyboard Durability | >6,000,000 keystrokes |
| Electrode Compatibility | Universal BNC + ATC (Automatic Temperature Compensation) input |
| Electrode Technology | ContATC™ (Compensated Automatic Temperature Compensation) |
| Brand | Hach |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Instrument Type | Portable |
| Parameter Types | Multi-parameter |
| pH Range | -2.00 to 19.99 |
| Temperature Range | -20 to 150 °C |
| mV Range | ±1999 mV |
| pH Resolution | 0.01 |
| Temperature Resolution | 0.1 °C |
| mV Resolution | 1 mV (0.1 mV in ±199.9 mV range) |
| pH Accuracy | ±0.01 |
| Temperature Accuracy | ±0.1 °C |
| mV Accuracy | ±1 mV |
| Calibration Points | 1–5 point, automatic or manual |
| Temperature Compensation | Manual or Automatic (with integrated temperature sensor) |
| Data Storage | Yes |
| Power Supply | 3 × AA batteries |
| IP Rating | IP67 |
| Battery Life | >1000 hours |
| Keypress Durability | 6 million cycles |
| Electrode | Hach 5052T Low-Ionic-Strength pH Electrode |
| Includes | Carrying case, calibration buffers (pH 4.01, 7.00, 10.01), storage solution, calibration tubes, and accessories |
| Brand | HACH |
|---|---|
| Origin | Imported |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | SG1000 Series Remote Monitoring Quality Control System |
| Pricing | Available Upon Request |
| Brand | HACH |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | si792 |
| Communication Protocols | HART®, PROFIBUS PA, Foundation® Fieldbus |
| Hazardous Area Certifications | FM, CSA, ATEX |
| Intrinsically Safe Rating | Class I, Division 1 (IS), Class I, Division 2 |
| Sensor Compatibility | GLI pH (differential & combination), ORP, Inductive Conductivity (GLI 3400 series), Electrodeless Conductivity (GLI 3700 series) |
| Diagnostic Capabilities | Asymmetry voltage monitoring, electrode slope tracking, response time evaluation, cable integrity check, glass electrode health assessment |
| Security Levels | Three-tier password protection (sensor calibration, transmitter configuration, administrator access) |
| Brand | Hach |
|---|---|
| Origin | Imported |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Portable Composite and Discrete Water Sampler |
| Model | Sigma SD900 |
| Enclosure Rating | NEMA 4X / 6, IP67 |
| Operating Temperature | 0–50 °C |
| Storage Temperature | −30–60 °C |
| Data Logging Capacity | 255 sample events + 255 system events |
| Sample Bottle Configurations | Up to 24 × 1 L PE bottles, or 8 × 2.3 L PE bottles, or 4 × 3.8 L PE/glass bottles, or 1 × 15.1 L (4 gal), 1 × 20.8 L (5.5 gal), or 1 × 9.5 L (2.5 gal) PE/glass bottle |
| Pump Tube Life | ≥20,000 cycles |
| Pump Type | Positive-displacement peristaltic pump with spring-loaded roller assembly and 3/8″ (9.5 mm) tubing |
| Software Interface | Hach SampleView™ for remote programming, event log export, and firmware updates |
| Power Supply | Rechargeable 12 V DC battery (optional AC adapter) |
| Dimensions (Standard Base) | 50.5 × 69.4 cm (19.9 × 27.3 in) |
| Brand | Hach |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | SL1000/250 |
| Instrument Type | Laboratory Water Quality Analyzer |
| Colorimetric Parameters | Free Chlorine, Total Chlorine, Free Ammonia, Total Ammonia, Monochloramine, Nitrite, Copper, Alkalinity, Phosphate, Dissolved Iron, Hardness, Peracetic Acid |
| Electrochemical Parameters | pH, Conductivity, Dissolved Oxygen (DO), Temperature, Ion-Selective Electrode (ISE) |
| Measurement Capacity | Up to 6 parameters simultaneously |
| Technology | Chemkey® Microfluidic Cartridge-Based System (U.S. Patents #9012234, #9052302, #9180449, #9182353) |