Hach
Filter
Showing 61–90 of 371 results
| Brand | Hach |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | BODTrak II |
| Instrument Type | Laboratory BOD Analyzer |
| Measurement Principle | Manometric (Pressure-Difference) Method |
| Measurement Ranges | 0–35, 0–70, 0–350, 0–700 mg/L O₂ |
| Detection Limit | 0.01 mg/L O₂ |
| Accuracy | ±2% at 235 mg/L BOD |
| Repeatability | ±2% at 235 mg/L BOD |
| Incubation Temperature | 20 °C (±0.5 °C) |
| Sample Throughput | 6 samples per run (473 mL bottles) |
| Data Storage | 480 data points per sample |
| Display | Real-time graphical trace with cursor readout |
| Power Supply | AC adapter |
| Dimensions | 28.9 × 26.0 × 9.8 cm |
| Weight | 3.6 kg |
| Brand | Hach |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China-manufactured under Hach licensing) |
| Model | BODTrak II |
| Instrument Type | Laboratory BOD Analyzer |
| Measurement Principle | Pressure Differential Method |
| Measurement Ranges | 0–35, 0–70, 0–350, 0–700 mg/L |
| Detection Limit | 1 mg/L |
| Accuracy | ±1 mg/L |
| Incubation Duration | 5–10 days (user-selectable) |
| Incubation Temperature | 20 °C ±0.5 °C |
| Repeatability | 3–5% RSD |
| Sample Throughput | Up to 6 samples simultaneously |
| Data Logging Interval | Every 15 minutes |
| Total Data Points Storage | 480 |
| Software Interface | HachLink™ PC software (Windows-compatible) |
| Compliance | Designed to meet ASTM D5210, ISO 5815-1, and EPA Method 405.1 requirements for BOD₅ determination |
| Brand | Hach |
|---|---|
| Origin | Imported |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Laboratory BOD Analyzer |
| Model | BODTrak II |
| Measurement Principle | Manometric (Pressure-Difference) Method |
| Measurement Range | 0–700 mg/L O₂ |
| Accuracy | ±5% of reading |
| Sample Throughput | 6 samples per run (473 mL bottles) |
| Incubation Temperature | 20 °C (±0.5 °C) |
| Data Storage | Up to 480 data points per sample |
| Display | Graphical LCD with real-time BOD curve visualization |
| Sensor | Integrated microprocessor-controlled pressure transducer |
| Power Supply | AC-powered magnetic stirrer base |
| Dimensions | 28.9 × 26.0 × 9.8 cm |
| Compliance | Designed to meet ASTM D5210, ISO 5815-1, and EPA 405-B-16-001 requirements for BOD₅ testing |
| Brand | Hach |
|---|---|
| Origin | USA |
| Model | BODTrak II |
| Measurement Principle | Manometric (pressure-difference) respirometry |
| Sample Capacity | 6 simultaneous samples |
| BOD Range | 0–700 mg/L (four auto-ranging scales: 0–35, 0–70, 0–350, 0–700 mg/L) |
| Resolution | 0.1 mg/L |
| Repeatability | CV ≤ 5% |
| Data Logging | 480 points (15-min interval) |
| Display | Backlit LCD with real-time BOD curve and numeric readout |
| Connectivity | USB interface for HachLink™ software |
| Power Supply | AC 220 V / 50 Hz |
| Compliance | ASTM D5210, ISO 5815-1, US EPA 405.1 (respirometric BOD), GLP-compliant data storage with timestamped audit trail |
| Brand | Hach |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Instrument Type | Laboratory BOD Analyzer |
| Principle | Manometric (Pressure-Difference) Method |
| Measurement Ranges | 0–35 mg/L, 0–70 mg/L, 0–350 mg/L, 0–700 mg/L |
| Detection Limit | 0.05 mg/L |
| Accuracy | ±0.1% of reading + 1 LSD |
| Single-Sample Analysis Time | 15 minutes |
| Repeatability | ≤5% |
| Sample Capacity | 6 simultaneous samples |
| Data Storage | 480 data points |
| Incubation Durations | 5, 7, or 10 days |
| Test Bottle Volume | 473 mL |
| Operating Temperature | 20 °C (68 °F) |
| Power Input | 230 V, 50/60 Hz |
| Output Voltage | 20.5 V DC |
| Brand | HACH |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | CA610 |
| Price | Upon Request |
| Measurement Range | 0.1–10 mg/L F⁻ |
| Accuracy | ±10% or ±0.10 mg/L (whichever is greater) |
| Detection Limit | 0.01 ppm |
| Cycle Time | 4.2 minutes |
| Analog Output | 1 × 4–20 mA (configurable within 0.1–10 mg/L range) |
| Alarm Outputs | 2 SPDT relays (5 A, 230 VAC), configurable for concentration alarm, system warning, or system shutdown |
| Brand | HACH |
|---|---|
| Origin | Imported |
| Manufacturer Status | Manufacturer |
| Form Factor | Benchtop |
| Application | Industrial Online Monitoring |
| Conductivity Range | 0–200 mS/cm |
| Salinity Range | 0–45 ppt |
| Accuracy | ±1% FS |
| Enclosure Rating | IP66 |
| Explosion Protection | NEPSI Ex ia IIC T4 Ga (GB/T 3836.x-2021 compliant) |
| Communication Protocol | HART 7 |
| Display | 3.5″ Graphical LCD with Icon-Based Menu |
| Housing Material | 316 Stainless Steel with Corrosion-Resistant Coating |
| Compensation Options | Temperature, Linear, Nonlinear (Ultra-Pure Water, Pure Water, Wastewater), and Custom Curves |
| Security | Password-Protected Configuration Access |
| Diagnostics | Real-time Sensor Health Monitoring & Predictive Alerting |
| Brand | HACH |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Instrument Type | Benchtop |
| Parameter Types | Multi-parameter |
| Measurement Range | pH: −2.0 to 16.0 |
| ORP | −2000 mV to +2000 mV |
| Resolution | pH: ±0.01 |
| ORP | ±1 mV |
| Temperature Accuracy | ≤0.2 °C (PT100/PT1000) |
| Enclosure Rating | IP66 |
| Certification | NEPSI Ex ia IIC T4 Ga, compliant with GB/T 3836.x–2021 |
| Communication Protocol | HART 7 |
| Housing Material | 316 Stainless Steel with corrosion-resistant coating |
| Display | 3.5″ graphical LCD with icon-based navigation and status visualization |
| Brand | HACH |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model Numbers | CA9300.0100 (pH/ORP), CA9300.0200 (Conductivity) |
| Power Supply | 100–240 VAC, 50/60 Hz ±10% |
| Enclosure Rating | IP65 |
| Display | 3.5-inch color LCD (Chinese UI) |
| Outputs | Dual 4–20 mA analog outputs, 1 × MODBUS RTU over RS-485 |
| Relay Outputs | 2 configurable SPDT relays |
| Mounting Options | Panel mount, wall mount, pipe clamp |
| Compliance | Designed for industrial process environments per IEC 61000-6-2/-6-4 EMC standards |
| Brand | HACH |
|---|---|
| Origin | Imported |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | CA9400 Single-Channel / Dual-Channel Transmitter |
| Pricing | Available Upon Request |
| Brand | Hach |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | CL17 |
| Instrument Type | Online Analyzer |
| Measurement Principle | DPD Colorimetric Method (N,N-Diethyl-p-phenylenediamine) |
| Measured Parameter | Residual Chlorine and Total Chlorine |
| Range | 0–5 mg/L as Cl₂ |
| Accuracy | ±5% or ±0.035 mg/L as Cl₂ (whichever is greater) |
| Repeatability | 0.02 mg/L as Cl₂ |
| Resolution | 0.001 mg/L as Cl₂ |
| Detection Limit | 0.035 mg/L as Cl₂ |
| Sample Temperature Range | 5–40 °C |
| Analog Output | 4–20 mA, scalable within 0–5 mg/L range |
| Alarm Outputs | Two user-configurable concentration alarms, each with SPDT relay (5 A, 230 VAC) |
| Dimensions | 42 mm (H) × 32 mm (W) × 18 mm (D) |
| Brand | Hach |
|---|---|
| Origin | USA |
| Manufacturer | Hach Company |
| Product Type | Imported |
| Model | CL17D Residual and Total Chlorine Analyzer – Distribution Network Version |
| Instrument Type | Online Analyzer |
| Measurement Principle | DPD Colorimetric Method (N,N-Diethyl-p-phenylenediamine) |
| Measured Parameter | Residual Chlorine / Total Chlorine |
| Range | 0–5 mg/L as Cl₂ |
| Accuracy | ±5% or ±0.005 mg/L as Cl₂ (whichever is greater) |
| Repeatability | ±0.035 mg/L or ±5% as Cl₂ (whichever is greater) |
| Detection Limit | 0.035 mg/L as Cl₂ |
| Sample Temperature Range | 5–40 °C |
| Cycle Time | 10 minutes |
| Analog Output | 4–20 mA (configurable across 0–5 mg/L range) |
| Alarm Outputs | Two user-configurable concentration alarms, each with SPDT relay (5 A, 230 VAC) |
| Dimensions | 42 × 32 × 18 cm |
| Turbidity & Color Compensation | Automatic |
| Calibration | Built-in calibration curve |
| Diagnostic Capability | Self-diagnostic system |
| Reagent Lifetime | Up to 120 days (unopened) |
| Brand | HACH |
|---|---|
| Origin | USA |
| Manufacturer | HACH Company (a Danaher subsidiary) |
| Product Type | Imported Online Analyzer |
| Model | CL17sc / CL17Dsc |
| Instrument Category | Online Residual & Total Chlorine Analyzer |
| Measurement Principle | DPD Colorimetric Method (ASTM D1253, ISO 7393-2) |
| Measured Parameter | Free Chlorine, Total Chlorine |
| Range | 0–10 mg/L as Cl₂ |
| Accuracy | ±5% or ±0.04 mg/L (whichever is greater) for 0–5 mg/L |
| Detection Limit | 0.03 mg/L as Cl₂ |
| Cycle Time | 2.5 min (standard) or 10 min (extended) per measurement |
| Compliance | Designed to meet EPA 334.0, USP <643>, and WHO Guidelines for drinking water quality monitoring |
| Brand | Hach |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | CLF10sc / CLT10sc |
| Instrument Type | Laboratory-Grade Analyzer |
| Measurement Principle | Amperometric (Three-Electrode Electrochemical Detection) |
| Measured Parameters | Free Chlorine, Total Chlorine |
| Measurement Range | 0–10 ppm |
| LOD | ≤30 ppb (0.030 ppm) |
| Resolution | 0.001 ppm (1 ppb) |
| Accuracy | ±3% for free chlorine |
| Repeatability | ±30 ppb or ±3%, whichever is greater |
| Operating Temperature | 0–45 °C (32–113 °F) |
| Compliance | EPA Method 334.0 |
| Brand | HACH |
|---|---|
| Origin | Imported |
| Manufacturer | DKK TOA Corporation |
| Model | CM31PW-1-1B |
| Portability | Portable |
| Conductivity Range | 0.05–200 µS/cm |
| TDS Range | 0–100 mg/L |
| Resistivity Range | 50 Ω·m–182 kΩ·m |
| Salinity Range | 0–100 mg/L |
| Temperature Range | 0–80 °C |
| Accuracy | ±0.5% FS |
| Minimum Resolution | 0.001 µS/cm |
| Electrode Constant | 0.01 cm⁻¹ |
| Repeatability | ±0.5% FS (conductivity/resistivity), ±0.2 °C (temperature) |
| Temperature Compensation | Manual/Automatic (0–100 °C) |
| Calibration | Electrode constant calibration + single-point temperature calibration |
| Data Storage | 1,000 measurement records |
| IP Rating | IP67 |
| Display | LCD |
| Output | Analog signal or RS-232C |
| Power | Two AA alkaline batteries or 100 VAC adapter |
| Dimensions | 35 × 78 × 173 mm (H×W×D) |
| Weight | 0.28 kg |
| Brand | Hach |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Instrument Type | Laboratory |
| Measurement Principle | UV Absorption Spectrophotometry (Portable) |
| Wavelength | 420 nm |
| Range | 0.7–15,000 mg/L COD |
| Accuracy | ≤ ±10% |
| Repeatability | ≤ ±5% |
| LOD | 0.1 mg/L |
| Analysis Time | 20 min per batch |
| Batch Capacity | 15 or 30 samples |
| Brand | Hach |
|---|---|
| Origin | Imported |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | TNTplus 820/821/822/823 Series COD Reagent Vials |
| Pricing | Available Upon Request |
| Brand | Hach |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model Series | COD Pre-Mixed Reagent Vials |
| Price Range | USD 55 – 280 (per kit) |
| Pack Sizes | 25 vials or 150 vials per kit |
| Compatible Instruments | DR6000, DR3900, DR1900, DR900, DR1010 |
| Measurement Ranges | 0.7–40 mg/L, 3–150 mg/L, 20–1500 mg/L, 200–15000 mg/L |
| Brand | Hach |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported |
| Model Range | COD21258-15, COD21258-25, COD21259-15, COD21259-25 |
| Measurement Ranges | 0–150 mg/L and 0–1500 mg/L |
| Package Sizes | 150-test and 25-test kits |
| Instrument Compatibility | Hach DR5000, DR2800, DR850, DR890 spectrophotometers and colorimeters |
| Brand | Hach |
|---|---|
| Origin | Imported |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Measurement Principle | Potassium Permanganate Oxidation with ORP Endpoint Detection |
| Range | 0–20 mg/L and 0–2000 mg/L |
| Repeatability | ±1% FS (0–20 mg/L), ±2% FS (20–200 mg/L), ±5% FS (>200 mg/L) |
| Resolution | 0.01 mg/L |
| Single-Test Duration | 60 minutes |
| Display | LCD |
| Stability | Zero Drift ±3% FS |
| Operating Environment | Indoor installation |
| Sample Temp. | 5–40°C, Ambient Pressure |
| Sample Volume per Test | 500 mL |
| Analog Output | 4–20 mA (max. load 600 Ω) |
| Power Supply | 220 VAC, 50/60 Hz |
| Power Consumption | Max. 550 VA, Avg. 200 VA |
| Dimensions | 600 × 600 × 1600 mm |
| Weight | 150 kg |
| Data Storage | 14-day onboard logging |
| Optional Accessories | Thermal printer interface |
| Maintenance Frequency | Low (automated line flushing, air-jet nozzle for titration tip) |
| Brand | Hach |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Instrument Type | Portable |
| Measurement Principle | Coulometric Titration (Acidic/Alkaline KMnO₄ Method) |
| Measurement Range | 0–5000 mg/L as O₂ |
| Accuracy | ±2% of full scale |
| Repeatability | ±2% of full scale |
| Detection Limit | 0.2 mg/L |
| Typical Analysis Time | 15 minutes |
| Batch Capacity | Single-sample per run |
| Brand | HACH |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Measurement Principle | Coulometric Titration with Acidic Potassium Permanganate Oxidation |
| Range | 0–20 / 40 / 100 / 200 / 400 / 1000 mg/L as O₂ |
| Repeatability | ±2% RSD |
| Accuracy | ±5% of reading |
| LOD | 0.4 mg/L |
| Resolution | 0.01 mg/L |
| Single-Test Duration | 5–10 min |
| Data Storage | 100 test records |
| Brand | Hach |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Instrument Type | Online Analyzer |
| Measurement Principle | Potassium Dichromate Digestion Method |
| Measurement Range | 10–5,000 mg/L COD |
| Repeatability | ≤5% |
| Measurement Cycle Time | 20 min (to >90% response) |
| Batch Capacity | 15 or 30 samples per cycle |
| Digestion Temperature | 175 °C |
| Digestion Duration Options | 3–120 min (selectable in 1-min increments) |
| Calibration Interval | User-defined automatic schedule |
| Cleaning Interval | User-defined automatic schedule |
| Maintenance Requirement | ~1 hour per month |
| Analog Outputs | Two 4–20 mA isolated outputs |
| Relay Outputs | Two 24 VDC / 1 A digital relays |
| Communication Interfaces | RS232, MODBUS RTU over RS485, Profibus DP (optional) |
| Data Storage | 2,000 measurement records |
| Operating Ambient Temperature | +5 to +40 °C |
| Power Supply | 220 VAC ±10%, 50–60 Hz |
| Power Consumption | ~100 VA |
| Dimensions (W×H×D) | 550 × 810 × 390 mm |
| Weight | ~25 kg (excluding reagents) |
| Brand | Hach |
|---|---|
| Model | CODmax III |
| Type | Online Analyzer |
| Measurement Principle | Potassium Dichromate Digestion Method |
| Range | 10–5000 mg/L COD |
| Accuracy | ±10% |
| Repeatability | ≤5% |
| Detection Limit | 5 mg/L |
| Cycle Time | 2 hours per sample |
| Batch Capacity | 15 samples per run |
| Compliance | Meets Chinese Environmental Monitoring Standard HJ 399-2017 and ISO 6060 |
| Brand | Hach |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | CODmax III |
| Instrument Type | Online Analyzer |
| Measurement Principle | Potassium Dichromate Digestion Method (High-Temperature Closed-System Digestion) |
| Detection Wavelength | LED at 620 nm |
| Measurement Range | 10.0–5,000 mg/L COD |
| Accuracy | ±10% (10.0–39.9 mg/L), ±6% (40.0–99.9 mg/L), ±3% (100.0–5,000.0 mg/L) |
| Optical Metrology | Multi-stage photometric dosing system |
| Sample Introduction | Precision piston pump with >12-month service life |
| Maintenance Interval | Extended via anti-fouling measurement cycle |
| Diagnostics | Integrated Prognosys predictive diagnostics and Diagnose self-diagnostic engine |
| Compliance | Fully aligned with HJ 377–2019, HJ 35X–2019, and method-equivalent to HJ 828–2017 |
| Brand | HACH |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Instrument Type | Online Analyzer |
| Measurement Principle | Potassium Dichromate Digestion Method (Online) |
| Wavelengths | 420 nm (Low Range), 610 nm (High Range) |
| Measurement Range | 10–5000 mg/L COD |
| Accuracy | ±8% of reading |
| Repeatability | ≤3% RSD |
| Detection Limit | 10 mg/L COD |
| Cycle Time | 20 min (standard digestion time |
| Operation Mode | Continuous measurement |
| Compliance | GB 11914–1989, ASTM D1252–2022 (Method B), ISO 6060:1989 |
| Brand | Hach |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | CODMn Pre-dosed Reagent Vials |
| Measurement Range | Low Range 0.50–5.00 mg/L, High Range 4.50–15.00 mg/L |
| Vial Size | 16 mm diameter |
| Package Quantity | 50 vials per kit |
| Digestion Temperature/Time | 100 °C / 30 min |
| Compatibility | DR6000, DR5000, DR3900, DR2800 Spectrophotometers |
| Regulatory Alignment | ASTM D1253, ISO 8467, Standard Methods 5210 B |
| Brand | HACH |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | COSMOS-25 |
| Turbidity Measurement Principle | Dual-channel 90° scattered light (DIN/EN 27027 & ISO 7027 compliant, 860 nm) + 8-angle multi-angle scattering verification |
| SS Measurement Principle | Enhanced multi-angle absorbance (8-channel, 860 nm) |
| Turbidity Range | 0.001–10,000 NTU |
| Turbidity Resolution | 0.001 NTU (0–0.999 FNU), 0.01 NTU (1–9.99 FNU), 0.1 NTU (10–99.9 FNU), 1 NTU (>100 FNU) |
| Turbidity Accuracy | < ±3% of reading |
| Turbidity Repeatability | < ±4% of reading |
| SS Range | ≥0.001 g/L (upper limit medium-dependent |
| SS Resolution | 0.001 g/L (0–0.999 g/L), 0.01 g/L (1–9.99 g/L), 0.1 g/L (10–99.9 g/L), 1 g/L (>100 g/L) |
| SS Accuracy | Medium- and calibration-dependent |
| SS Repeatability | Dependent on sample homogeneity |
| Cleaning | Integrated mechanical self-positioning wiper |
| Signal Transmission | Long-distance analog/digital output without intermediate transmitter |
| Architecture | Modular, field-expandable design |