Hach
Filter
Showing 331–360 of 371 results
| Brand | HACH |
|---|---|
| Origin | Imported |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Type | Online Sensor |
| Measurement Range | 0.001–4000 NTU |
| Operating Temperature | 0–40 °C |
| Accuracy | ±1% of reading or ±0.001 NTU, whichever is greater |
| Optical Wavelength | 880 nm (near-infrared LED) |
| Detection Principle | Dual-angle scattered light photometry (90° for turbidity |
| Self-cleaning Capability | Yes |
| Compliance | Designed for continuous operation in municipal and industrial water/wastewater applications per ISO 7027 and EPA Method 180.1 principles |
| Brand | HACH |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Instrument Type | Online Analyzer |
| Model | SOLITAX™ sc |
| Measurement Principle | Dual-Angle Infrared Nephelometry (90° forward scatter for turbidity |
| Light Source | 880 nm LED |
| Optical Compensation | Color-independent measurement via near-infrared wavelength |
| Probe Feature | Integrated self-cleaning mechanism |
| Installation Options | Submersible, flow-through, or insertion-type mounting |
| Compliance Context | Designed for continuous compliance monitoring per ISO 7027, ASTM D6508, and EPA Method 180.1 |
| Brand | HACH |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | SONATAX sc |
| Measurement Principle | Ultrasonic Time-of-Flight |
| Measurement Range | 0.2–12 m |
| Resolution | <0.04 m |
| Accuracy | ±0.1 m (with ±0.05 m offset tolerance) |
| Response Time | 10–600 s (user-adjustable) |
| Calibration | Single-point automatic calibration at power-on |
| Pressure Rating | ≤0.3 bar |
| Operating Temperature | 0–50 °C |
| Temperature Compensation | Automatic |
| Ingress Protection | IP68 |
| Maximum Flow Velocity | ≤3 m/s |
| Dimensions (H×D) | 130 mm × 185 mm |
| Weight | ~3.5 kg |
| Maintenance Interval | <1 hour/month |
| Cable Length | Standard 10 m (extendable up to 100 m) |
| Compatible Controllers | SC100 (supports 2 probes), SC1000 (supports 8 probes) |
| Self-Cleaning Mechanism | Mechanical wiper system |
| Brand | HACH |
|---|---|
| Model | SP510 |
| Measurement Principle | Colorimetric (Titanium Yellow Method) |
| Range | 0.3–100 mg/L as CaCO₃ |
| Accuracy | ±10% of setpoint (0.3–2 mg/L), ±4% of setpoint (5–100 mg/L) |
| Cycle Time | ~2 minutes per measurement |
| Alarm Outputs | 1 SPDT relay |
| Power Supply | 115/230 VAC, 50/60 Hz |
| Certifications | UL, CSA, CE |
| Reagent Consumption | Up to 2 months per reagent pack |
| Maintenance Interval | Pump tube replacement every 6 months |
| Calibration | Automatic zero and span calibration supported |
| Compliance | Designed for continuous operation in industrial water treatment environments per ISO 9001-manufactured quality system |
| Brand | Hach |
|---|---|
| Origin | USA |
| Model | SP510 |
| Detection Principle | Colorimetric (EDTA Complexometric Titration) |
| Measurement Range | 0.3–100 mg/L as CaCO₃ |
| Accuracy | ±10% of setpoint (0.3–2 mg/L), ±4% of setpoint (5–100 mg/L) |
| Cycle Time | ~2 minutes per measurement |
| Alarm Output | 1 SPDT relay |
| Power Supply | 115/230 VAC, 50/60 Hz |
| Certifications | UL, CSA, CE |
| Reagent Consumption | Up to 2 months per reagent pack |
| Maintenance Interval | Pump tube replacement every 6 months |
| Calibration | Automatic on-demand and scheduled calibration |
| Brand | Hach |
|---|---|
| Model | SP510 |
| Origin | USA |
| Instrument Type | Online Water Quality Analyzer |
| Measurement Principle | Colorimetric Method (Calcium/Magnesium Complexation with Arsenazo III) |
| Measured Parameter | Total Hardness (as CaCO₃) |
| Range | 0.3–100 mg/L as CaCO₃ |
| Repeatability | ≤4% RSD |
| Accuracy | ±10% of setpoint at 0.3–2 mg/L |
| Cycle Time | ~2 minutes per measurement |
| Calibration | Automatic on-board standardization using factory-preloaded reagent cartridges |
| Reagent Consumption | One cartridge supports ~60 days of continuous operation |
| Maintenance Interval | Pump tubing replacement every 6 months |
| Alarm Outputs | 1 SPDT relay (configurable setpoints: 0.3, 1, 2, 5, 10, 20, 50, 100 mg/L) |
| Power Supply | 115/230 VAC, 50/60 Hz |
| Certifications | UL 61010-1, CSA C22.2 No. 61010-1, CE marked per EMC and LVD directives |
| Compliance | Designed for use in industrial water treatment environments requiring GLP-aligned operational traceability |
| Brand | HACH |
|---|---|
| Origin | Imported |
| Manufacturer | HACH Company |
| Instrument Type | Benchtop/Laboratory |
| Measurement Range | 0.0001–1000 FNU (NTU) |
| Resolution | 0.0001–0.9999 / 1.000–9.999 / 10.00–99.99 / 100–1000 FNU (NTU) |
| Operating Temperature | 2–40 °C |
| Accuracy | ±0.008 FNU + ±1% of reading (0–10 FNU) |
| Sample Flow Rate | 1.0–2.0 L/min |
| Sample Temperature Range | 0–70 °C |
| Power Supply | 220 VAC, 50 Hz, 40 VA |
| Optical Principle | Surface Scatter (90° scattered light detection at air–liquid interface) |
| Compliance | Meets ISO 7027 and EPA Method 180.1 requirements for turbidity measurement |
| Output Interfaces | Compatible with HACH SC100 or SC1000 universal controllers (4–20 mA analog, Modbus RTU, relay alarms) |
| Brand | HACH |
|---|---|
| Model | TC2300 |
| Type | Online Liquid Particle Counter |
| Origin | Shanghai, China |
| Flow Rate Range | High-Flow Configuration |
| Flow Rate Accuracy | ≤ ±2% |
| Repeatability | ≤ ±2% (at concentration ≥ 100 counts/mL) |
| Size Distribution Accuracy | ±10% or ≤ 5 counts/mL (whichever is greater) |
| Measurement Accuracy (Count Error) | ≤ ±5% |
| Brand | HACH |
|---|---|
| Model | TC2300 |
| Type | Online Optical Particle Counter |
| Origin | Imported (USA-manufactured) |
| Manufacturer | HACH Company, a Danaher Corporation business |
| Particle Detection Principle | Light Obscuration (LO) / Single-Particle Optical Sizing (SPOS) |
| Measurement Channels | 8 user-selectable size thresholds |
| Flow Control | Integrated precision peristaltic sampling pump with adjustable flow rate (typically 20–60 mL/min) |
| Display | 7-inch full-color capacitive touchscreen interface |
| Compliance | Designed to support ASTM D6978-05 (for clean water), ISO 21501-4, and USP <788> & <789> particulate matter testing guidelines (when configured per application requirements) |
| Data Output | Modbus RTU/TCP, 4–20 mA analog outputs, optional Ethernet/IP or OPC UA integration |
| Enclosure Rating | IP65-rated NEMA 4X housing for industrial environments |
| Brand | HACH |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | Titralab 1000 |
| Instrument Type | General-purpose Potentiometric Titrator |
| Application Scope | Dedicated Use |
| pH Measurement Range | 0–14 |
| Burette Resolution | 1/20,000 |
| Titrant Dispensing Precision | ±0.001 mL |
| Display Resolution (pH/mV) | 0.001 pH / 0.1 mV |
| Temperature Range | –10 to +100 °C (0.1 °C resolution) |
| Compliance | GLP, FDA 21 CFR Part 11, ISO/IEC 17025-aligned operation |
| Brand | Hach |
|---|---|
| Origin | USA |
| Model | AT1000 |
| Instrument Type | General-purpose Potentiometric Titrator |
| Titration Modes | Potentiometric (zero-current or controlled-current), Amperometric, Colorimetric |
| Measured Parameters | mV/pH, Conductivity, Temperature |
| Resolution | ±0.1 mV / ±0.001 pH |
| Conductivity | ±0.5% of reading |
| Temperature | ±0.3°C |
| Sample Holder | Integrated magnetic stirrer, max. 250 mL beaker |
| Electrode Inputs | Dual-channel, supports IntelliCAL digital electrodes (plug-and-play), analog electrodes, and colorimetric sensors |
| Burette Capacity Options | 2.5 / 5 / 10 / 25 mL (ISO 8655-3 compliant) |
| Stepper Motor Resolution | 20,000 steps with microstepping (128 µsteps/step) |
| Calibration Modes | Electrode and titrant calibration (auto, fixed, custom |
| Calibration Reminders | User-definable intervals |
| Data Storage | Last 100 measurements (samples, blanks, QC standards) + last 10 calibrations, including timestamp, operator ID, sample ID |
| Data Export | USB drive, CSV format |
| Interface | Silicone keypad |
| Display | 5.7" color VGA touchscreen |
| Calibration Curve Display | Direct or derivative plots, electrode response curves |
| Software & Accessories | PC software (TitraWin), analytical balance interface, autosampler, barcode scanner, peristaltic pump, paddle stirrer |
| Maintenance Scheduler | Configurable user-defined schedule |
| Predefined Functions | Bubble purge, reagent pre-fill, replaceable burette and pump modules |
| Password Protection | Enabled, customizable |
| Languages | English, French, German, Italian, Spanish |
| Connectivity | 2× electrode ports, 2× USB, 1× RS-232, 1× Ethernet |
| Dimensions (H×W×D) | 220 × 400 × 360 mm |
| Weight | 4 kg |
| Power | 100–240 VAC, 50/60 Hz |
| Operating Environment | 15–35°C, 20–80% RH (non-condensing) |
| Storage Range | −5–40°C |
| Safety & EMC Compliance | IEC/EN 61010-1, IEC/EN 61326-1 |
| Application Library | Preloaded methods for water/wastewater (alkalinity, hardness, chlorine, FOS/TAC), food & beverage (total acidity, SO₂, salt), petrochemical (TAN, TBN, bromine number), environmental (AUTOCAT), and Karl Fischer moisture (KF1121 variant) |
| Brand | Hach |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | TitraLab AT1000 |
| Titration Types | Potentiometric (zero-current or controlled-current), Amperometric, Colorimetric |
| Titration Modes | Sample, Blank, Sample + Blank, QC Sample, QC Sample + Blank |
| Measured Parameters | mV/pH, Conductivity, Temperature |
| Resolution | mV/pH: ±0.1 mV / ±0.001 pH |
| Conductivity | ±0.5% of reading |
| Temperature | ±0.3 °C / ±0.51 °F |
| Sample Holder | Integrated design with magnetic stirring |
| max. beaker capacity | 250 mL |
| Electrode Inputs | Dual-channel |
| Burette Capacities | 2.5 / 5 / 10 / 25 mL (ISO 8655-3 compliant) |
| Motor Resolution | 20,000 steps with microstepping (128 μsteps/step) |
| Calibration Modes | Electrode & titrant calibration — automatic, fixed-point, or user-defined (up to 5 points) |
| Calibration Scheduling | Configurable interval-based alerts and reminders |
| Data Storage | Last 100 measurements (samples, blanks, QC samples) + last 10 calibrations, including timestamp, operator ID, sample ID |
| Data Export | USB drive |
| Interface | 5.7" color VGA touchscreen |
| Calibration Curve Display | Direct or derivative plots |
| Connectivity | 2× electrode ports, 2× USB, 1× RS-232, 1× Ethernet |
| Dimensions (H×W×D) | 220 × 400 × 360 mm |
| Weight | 4 kg |
| Power Supply | 100–240 V AC, 50/60 Hz |
| Operating Environment | 15–35 °C, 20–80% RH (non-condensing) |
| Storage Range | −5–40 °C |
| Safety Certification | IEC/EN 61010-1 |
| EMC Compliance | IEC/EN 61326-1 |
| Brand | Hach |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | TL23 Benchtop Turbidimeter |
| Pricing | Upon Request |
| Brand | Hach |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported |
| Model | TL23 Series |
| Measurement Range | 0–20000 NTU |
| Resolution | 0.001 NTU |
| Operating Temperature | 0–40 °C |
| Accuracy | ±2% (0–1000 NTU), ±5% (1000–4000 NTU), ±10% (4000–10000 NTU) |
| Compliance | EPA Method 180.1, ISO 7027, DIN EN 27027, DIN 38404, NFT 90-33 |
| Display | 7-inch color touchscreen |
| Light Source | Tungsten lamp or LED (860 ± 30 nm) |
| Units | NTU, FNU, FAU, EBC, Abs, %T, mg/L |
| Sample Cell | 95 × 25 mm borosilicate glass vial with rubber-sealed cap |
| Data Storage | 2000 records (measurements, calibrations, verifications) |
| Interface | Dual USB-A ports |
| Power | 100–240 V AC, 50/60 Hz, 3.4 A |
| Certifications | CE, RoHS, CMC |
| Warranty | 1 year |
| Brand | HACH |
|---|---|
| Origin | USA |
| Model | TL23 Series |
| Measurement Principle | Nephelometric Turbidity (90° light scatter, compliant with ISO 7027 and EPA Method 180.1) |
| Light Source | Tungsten halogen lamp (stable output, 860 ± 30 nm) |
| Detection Range | 0.001–4000 NTU (auto-ranging) |
| Resolution | 0.001 NTU (at low range), 1 NTU (at high range) |
| Accuracy | ±2% of reading or ±0.01 NTU (whichever is greater) |
| Repeatability | <0.5% RSD |
| Sample Cell | Standard 25-mm round glass vials (also compatible with 50-mm square cells and flow-through cells) |
| Calibration | Up to 6-point user-defined calibration with traceable StablCal® standards |
| Data Storage | 1000+ measurement records with timestamp, operator ID, and calibration history |
| Connectivity | USB and optional RS-232 |
| Compliance | Meets ISO 7027:2016, EPA 180.1, ASTM D6508, and GLP/GMP data integrity requirements |
| Brand | Hach |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Product Type | Benchtop/Laboratory |
| Model | TL2300 |
| Measurement Range | 0–4000 NTU |
| Resolution | 0.001 NTU |
| Operating Temperature | 0–40 °C |
| Accuracy | ±2% + 0.01 NTU (0–1000 NTU) |
| Brand | HACH |
|---|---|
| Origin | USA |
| Product Line | Phosphate Pre-Mixed Reagent Series |
| Measurement Range (TNT843) | 0.05–1.50 mg/L PO₄–P (Reactive Phosphate) |
| Measurement Range (TNT846) | 0.15–4.50 mg/L PO₄–P (Total Phosphate) |
| Package Format | 25-vial sealed kits |
| Compliance | Designed for ASTM D515-89, ISO 6878:2004, and EPA Method 365.1 |
| Brand | Hach |
|---|---|
| Model | TSS Portable |
| Measurement Principle | Multi-beam alternating light method with infrared diodes |
| Turbidity Range | 0.001–4000 NTU |
| Suspended Solids Range | 0.001–400 g/L (1–400,000 mg/L, upper limit sample-dependent) |
| Turbidity Accuracy | ±3% or ±0.02 NTU (whichever is greater) |
| Suspended Solids Accuracy | ±4% or ±0.001 g/L (whichever is greater) |
| Turbidity Resolution | 0.001 NTU (0–0.999), 0.01 NTU (1–9.99), 0.1 NTU (10–99.9), 1 NTU (>100) |
| Suspended Solids Resolution | 0.001 g/L (0–0.999), 0.01 g/L (1–9.99), 0.1 g/L (10–99.9), 1 g/L (>100) |
| Turbidity Units | NTU, FNU, EBC |
| SS Units | mg/L, g/L, ppm, % |
| Calibration | 4 pre-stored SS calibration curves + 1 turbidity curve |
| Bubble Compensation | Automated software-based correction |
| Sensor Material | Electropolished stainless steel housing with sapphire optical window |
| Data Storage | 290 measurement records (timestamp, location, value, homogeneity flag) |
| Operating Modes | Single-point, interval, or continuous measurement |
| Power | Rechargeable battery — up to 30 days in typical intermittent use, 4 hours in continuous mode |
| Display | Backlit graphical LCD with intuitive menu navigation |
| Brand | Hach |
|---|---|
| Origin | USA |
| Model | TSS Portable |
| Instrument Type | Portable |
| Measurement Principle | Multi-beam alternating infrared photometry with dual-channel 90° scattering (turbidity) and six-channel multi-angle absorbance-corrected detection (suspended solids) |
| Turbidity Range | 0.001–4000 NTU |
| Suspended Solids Range | 0.001–400 g/L (1–400,000 mg/L, upper limit sample-dependent) |
| Turbidity Accuracy | ±3% or ±0.02 NTU (whichever is greater) |
| SS Accuracy | ±4% or ±0.001 g/L (whichever is greater) |
| Turbidity Resolution | 0.001 NTU (0–0.999), 0.01 NTU (1–9.99), 0.1 NTU (10–99.9), 1 NTU (>100) |
| SS Resolution | 0.001 g/L (0–0.999), 0.01 g/L (1–9.99), 0.1 g/L (10–99.9), 1 g/L (>100) |
| Units | NTU, FNU, EBC (turbidity) |
| Calibration | 4 pre-stored SS calibration curves + 1 turbidity curve |
| Bubble Compensation | Real-time software-based bubble interference correction |
| Sensor Material | Electropolished 316 stainless steel housing with scratch-resistant sapphire window |
| Data Storage | 290 measurement records (timestamp, location, value, homogeneity flag) |
| Operating Modes | Single-point, Interval, Continuous |
| Battery | Rechargeable Li-ion |
| Display | Backlit graphical LCD with intuitive menu navigation |
| Compliance | Meets DIN EN ISO 7027 (turbidity), supports ASTM D3852, ISO 13319, and USP <730> for suspended solids quantification in water matrices |
| Brand | HACH |
|---|---|
| Origin | Imported |
| Manufacturer | HACH Company |
| Model | TSS Portable |
| Power Supply | Rechargeable Battery |
| Measurement Principle | Dual-beam alternating infrared LED optical system with bubble compensation |
| Calibration | Multi-curve calibration support |
| Construction | Rugged, field-deployable housing |
| Compliance | Designed for ASTM D6507, ISO 7027, and USP <85> turbidity measurement guidelines |
| Sample Compatibility | Liquid samples from municipal/industrial wastewater, drinking water, surface water, and activated sludge basins |
| Brand | Hach |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Instrument Type | Portable |
| Model | TSS sc |
| Measurement Principle | Dual-source, 8-beam infrared (860 nm) nephelometric and multi-angle absorption method |
| Turbidity Range | 0.001–4000 FNU/NTU |
| SS Range | 0.001–500 g/L |
| Turbidity Accuracy | ±5% of reading or ±0.01 FNU/NTU |
| Turbidity Repeatability | <3% |
| SS Repeatability | <4% |
| Response Time | 1 s |
| Max Pressure | up to 16 bar (model-dependent) |
| Temp Range | –10°C to +90°C (model-dependent) |
| Compliance | DIN EN 27027 / ISO 7027 (turbidity), software-based bubble compensation |
| Probe Materials | Sapphire window, optional titanium alloy (TITANIUM2/TITANIUM7), sanitary-grade stainless steel, explosion-proof (EX1), high-temp (HT), variable-pressure (VARI), extended-range (XL) |
| Brand | HACH |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | TSS sc Probe |
| Instrument Type | Online |
| Measurement Principle | Dual-source, 8-beam infrared (860 nm) optical system |
| Compliance | DIN EN 27027 / ISO 7027 (turbidity), multi-angle scattering for suspended solids |
| Material Options | Sapphire measuring window, titanium alloy body (corrosive media), hygienic 3-A compliant design, high-temperature version (up to 90 °C), ATEX-certified explosion-proof variant (Zone 1) |
| Cleaning Option | Optional automatic brush cleaner |
| Sample Compatibility | Municipal wastewater, industrial effluents, surface water, drinking water, process streams in pulp & paper, power generation, pharmaceuticals, food & beverage, chemical, and aluminum production |
| Brand | Hach |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | TU5 Series Turbidimeter |
| Pricing | Upon Request |
| Brand | Hach |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | TU5200 |
| Product Type | Benchtop/Laboratory |
| Measurement Range | EPA: 0–700 NTU, FNU, TE/F, FTU |
| ISO | 0–1000 NTU/FNU/TE/F/FTU |
| Resolution | 0.0001 NTU / FNU / TE/F / FTU / EBC / mg/L |
| Operating Temperature | 10–40 °C (50–104 °F), Relative Humidity: 5–95% RH (non-condensing) |
| Accuracy | ±2% of reading + 0.01 NTU for 0–40 NTU |
| Brand | HACH |
|---|---|
| Origin | Imported |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | TX1315 |
| Instrument Type | Field-Portable |
| Biological Indicator | *Aliivibrio fischeri* (formerly *Vibrio fischeri*) bioluminescent bacteria |
| Operating Temperature Range | +5 °C to +45 °C |
| Storage Temperature Range | −10 °C to +50 °C |
| Reagent Temperature Range | +5 °C to +45 °C |
| Batch Capacity | Up to 50 sequential tests per reagent kit (wastewater matrix) |
| Detection Time | <15 minutes for luminescence-based toxicity assay |
| Measurement Principle | Bioluminescence inhibition assay (ISO 11348-3 compliant) and ATP bioluminescence quantification (ISO 22192 & EPA 1605B aligned) |
| Brand | HACH |
|---|---|
| Model | Txpro-2 |
| Measurement Principle | Quadruple-beam Optical Transmission/Scattering |
| Measurement Range (RD240/242) | 0–10 g/L |
| Measurement Range (RD260/262) | 0–25 g/L |
| Accuracy (RD240/242) | ±2% of reading or ±0.1 g/L, whichever is greater |
| Accuracy (RD260/262) | ±2% of reading or ±0.2 g/L, whichever is greater |
| Repeatability (RD240/242) | ±2% of reading or ±0.05 g/L, whichever is greater |
| Repeatability (RD260/262) | ±2% of reading or ±0.1 g/L, whichever is greater |
| Operating Temperature | –20 °C to +55 °C |
| Analog Outputs | Two isolated 0/4–20 mA outputs, max. load 800 Ω |
| Relays | Three SPDT relays, 2 A @ 250 VAC |
| Signal Averaging | Adjustable from 1 second to 5 minutes |
| Power Supply | 90–265 VAC, 50/60 Hz |
| Max. Power Consumption | 25 VA |
| Enclosure Rating | NEMA 4X (IP66) |
| Mounting | Pipe clamp for up to 50 mm OD pipe |
| Compliance | CE, UL 61010-1, CSA C22.2 No. 61010-1 |
| Dimensions | 144 × 144 × 150 mm |
| Brand | HACH |
|---|---|
| Origin | Imported |
| Manufacturer | HACH Company |
| Model | U53 |
| Measurement Principle | Ultrasonic Time-of-Flight (Pulse-Echo) |
| Range | 0.25–6.0 m |
| Depth Resolution | ±1 mm |
| Accuracy | ±0.5% of full scale |
| Repeatability | ±0.1% of full scale |
| Sensitivity | ±0.1% of full scale |
| Temperature Compensation Range | –40 to +80 °C |
| Operating Ambient Temperature | –20 to +60 °C |
| Output | Two independent 4–20 mA or 0–20 mA analog outputs |
| Relays | Four SPDT relays |
| Enclosure Rating | NEMA 4X (IP65) |
| Mounting Options | Panel, surface, and pipe mounting |
| Sensor Weight | 1.6 kg |
| Sensor Cable Length | 3.05 m (10 ft) |
| Instrument Weight | 0.5 kg |
| Flow Units | L/s, m³/s, gal/min, ft³/s, ML/d, Mgal/d |
| Depth Units | mm, m, in, ft |
| Brand | HACH |
|---|---|
| Origin | USA |
| Manufacturer | HACH Company |
| Product Type | Imported |
| Model | ULR CL17 sc |
| Instrument Category | Online Analyzer |
| Measurement Principle | DPD Colorimetric Method (ASTM D1253, ISO 7393-2) |
| Measured Parameter | Total Chlorine (as Cl₂) |
| Measurement Range | 0.008–5 mg/L Cl₂ |
| Accuracy | ±5% or ±0.01 mg/L (whichever is greater) for 0–4 mg/L |
| Detection Limit | 0.008 mg/L Cl₂ at 25 °C |
| Brand | HACH |
|---|---|
| Origin | USA |
| Model | ULR CL17sc |
| Measurement Principle | DPD (N,N-Diethyl-p-phenylenediamine) Colorimetric Method |
| Measurement Range | 0.008–5 mg/L Cl₂ |
| Accuracy | ±5% or ±0.01 mg/L (whichever is greater) for 0–4 mg/L |
| Detection Limit | 0.008 mg/L Cl₂ at 25°C |
| Cycle Time | 2.5 minutes |
| Sample Flow Rate | 60–200 mL/min |
| Inlet Pressure | 0.3–5.2 bar (to Y-strainer) |
| Sample Temperature | 5–40°C |
| Operating Temperature | 5–40°C |
| Operating Humidity | 0–90% RH, non-condensing |
| IP Rating | IP66 |
| Power Supply | 12 VDC, max. 400 mA |
| Dimensions (H×W×D) | 342 × 329 × 177 mm |
| Weight | 4.1 kg |
| Light Source | LED at 510 nm, 1 cm optical path |
| Certifications | CE (EN 61326-1, CISPR 11, EN 50581), ACMA RCM, Korea KC, FCC DoC, IEC/EN 60529, ICES-003 |
| Brand | HACH |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | ULTRATURB plus sc |
| Measurement Range | 0–1000 FNU (NTU) |
| Light Source | 860 nm Infrared LED |
| Detection Principle | ISO 7027 Compliant Ratio Method (90° + 180° Dual-Detector Scattering) |
| Self-Cleaning Option | Magnetic Coupling Brush System |
| Calibration Support | Dry-Check Validation Module |
| Compliance | ISO 7027, EN 27027, US EPA Method 180.1 (for turbidity), GLP/GMP-ready data logging capability |