| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | MP430 |
| Temperature Range | Ambient to 350 °C |
| Heating Rate | 0.1–20 °C/min |
| Temperature Repeatability | ±0.2 °C (at 0.20 °C/min) |
| Temperature Accuracy | ±0.4 °C (<200 °C), ±0.7 °C (<300 °C) |
| Capillary Dimensions | Sealed-end, OD 1.3–1.4 mm, L 110 mm |
| Sample Capacity | 4 samples per run |
| Temperature Resolution | 0.1 °C |
| Camera | 720p HD, 8× optical zoom |
| Display | 8-inch capacitive TFT touchscreen running Android OS |
| Data Storage | Up to 128 GB (supports USB backup/restore) |
| Connectivity | Wi-Fi, USB ×3, RS-232, RJ45 |
| Compliance | FDA 21 CFR Part 11 (audit trail enabled), GLP/GMP-ready user management & electronic signature support |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | MP450 |
| Temperature Range | Ambient to 350 °C |
| Heating Rate | 0.1–20 °C/min |
| Temperature Repeatability | ±0.2 °C (at 0.20 °C/min) |
| Temperature Accuracy | ±0.4 °C (<200 °C), ±0.7 °C (<300 °C) |
| Capillary Dimensions | Sealed-end, OD 1.3–1.4 mm, L 110 mm |
| Sample Capacity | 4 samples per run |
| Temperature Resolution | 0.1 °C |
| Data Storage | 128 GB internal (≥40,000 min video archive) |
| Compliance | FDA 21 CFR Part 11 (audit trail enabled), GLP/GMP-ready |
| Display | 8-inch capacitive TFT touchscreen (Android OS) |
| Camera | 720p HD, 8× optical zoom |
| Connectivity | USB ×3, RS-232, Wi-Fi, RJ45 Ethernet |
| Cooling | Ambient to 50 °C in ≤7 min |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | MP470 |
| Temperature Range | Ambient to 400 °C |
| Heating Rate | 0.1–20 °C/min |
| Temperature Repeatability | ±0.2 °C (at 0.20 °C/min) |
| Temperature Accuracy | ±0.4 °C (<200 °C), ±0.7 °C (<300 °C) |
| Capillary Dimensions | Sealed-end, OD 1.3–1.4 mm, L 110 mm |
| Sample Capacity | 4 samples per run |
| Temperature Resolution | 0.1 °C |
| Display | 8-inch capacitive TFT touchscreen (Android OS) |
| Data Storage | Up to 128 GB (≥40,000 min video archive) |
| Connectivity | USB ×3, RS232, Wi-Fi, RJ45 |
| Video | 720p, 8× optical zoom, real-time watermarking (timestamp + temperature), synchronized thermal profile playback |
| Calibration | Up to 6-point certified reference material calibration |
| Compliance | FDA 21 CFR Part 11 audit trail, user role-based access control (Admin/Supervisor/Operator/IT), password aging & complexity policies, screen lock timeout |
| Brand | Hanon |
|---|---|
| Origin | Shanghai, China |
| Model | MP490 |
| Temperature Range | Ambient to 400 °C |
| Heating Rate | 0.1–20 °C/min |
| Temperature Repeatability | ±0.2 °C (at 0.20 °C/min) |
| Temperature Accuracy | ±0.4 °C (<200 °C), ±0.7 °C (<300 °C) |
| Capillary Dimensions | Sealed-end, OD 1.3–1.4 mm, L 110 mm |
| Sample Capacity | 4 samples per run |
| Temperature Resolution | 0.01 °C |
| Data Storage | 128 GB internal (≥40,000 min video capacity) |
| Display | 8-inch capacitive TFT touchscreen (Android OS) |
| Camera | 720p HD, 8× optical zoom |
| Compliance | FDA 21 CFR Part 11 (audit trail enabled), GLP/GMP-ready |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | N110 |
| Instrument Type | Portable NIR Spectrometer |
| Principle | MEMS-based Micro-Grating Monochromator with Array Detector |
| Wavelength Range | 640–1050 nm (Reflectance), 340–750 nm (Transmittance) |
| Optical Resolution | ≤20 nm (Reflectance), ≤14 nm (Transmittance) |
| Wavelength Repeatability | ±0.5 nm |
| Noise Level | ≤60 µAU |
| Signal-to-Noise Ratio | ≥7500 |
| Operating Temperature | 5–40 °C |
| Relative Humidity | <85% RH (recommended <75% RH) |
| Dimensions (L×W×H) | 179 × 126.5 × 52.6 mm |
| Weight | 215 g |
| Power Supply | DC 5 V / 1000 mA |
| Tungsten Lamp Current | 400 mA × 2 |
| Sampling Modes | Reflectance Ratio, Transmittance |
| Data Acquisition Interval | Configurable via Hanir Software |
| Scan Speed | Up to 10 spectra/sec (typical, dependent on integration time) |
| Software Platform | Android-based Hanir v3.x with GLP-compliant audit trail logging |
| Chemometrics Engine | Integrated MEMS-optimized PLS and PCA algorithms |
| Compliance | Supports ASTM E1655, ISO 12099, and USP <857> spectral data handling conventions |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | N500 |
| Instrument Type | Portable |
| Principle | Micro-Electro-Mechanical Systems (MEMS)-based Fabry–Pérot Interferometer (FPI) |
| Wavelength Range | 1750–2150 nm (extendable to 2450 nm) |
| Detector | InGaAs |
| Wavelength Resolution (FWHM) | ≤20 nm (≤1% of operating wavelength) |
| Wavelength Accuracy | ±1 nm |
| Signal-to-Noise Ratio (SNR) | ≥3000 |
| Sample Measurement Time | <30 s |
| Light Source Lifetime | 5000 h |
| Measurement Mode | Diffuse Reflectance |
| Dimensions (L×W×H) | 395 × 280 × 215 mm |
| Weight | 5.5 kg |
| Included Computing Platform | Microsoft Surface tablet |
| Software | MEMS Chemometrics Suite |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | N500 |
| Instrument Type | Portable |
| Measurement Principle | MEMS-based Micro-FPI (Fabry–Pérot Interferometer) |
| Wavelength Range | 1750–2150 nm |
| Sampling Mode | Diffuse Reflectance |
| Detector Type | InGaAs |
| Spectral Resolution (FWHM) | ≤20 nm (≤1% of center wavelength) |
| Wavelength Accuracy | ±1 nm |
| Signal-to-Noise Ratio (SNR) | ≥3000 |
| Measurement Time per Sample | <30 s |
| Light Source Lifetime | 5000 h |
| Dimensions (L×W×H) | 395 × 280 × 215 mm |
| Weight | 5.5 kg |
| Integrated Computing Platform | Microsoft Surface Tablet |
| Software Suite | MEMS Chemometrics Platform (Model Management, Quantitative Analysis, Audit Trail, User Permissions) |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | N550 |
| Instrument Type | Laboratory NIR Spectrometer |
| Principle | MEMS Micro-Electro-Mechanical Systems Spectral Modulation |
| Wavelength Range | 900–1700 nm |
| Detector | Thermoelectrically Cooled InGaAs Array (256 pixels) |
| Slit Width | 50 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | ±0.2 nm |
| Signal-to-Noise Ratio | ≥3000 |
| Measurement Time per Sample | <30 s |
| Sampling Mode | Diffuse Reflectance |
| Sample Holders | 10 cm wide-mouth cup & 3 cm powder cup |
| Dimensions (L×W×H) | 450 × 280 × 228 mm |
| Weight | 15 kg |
| Compliance | ASTM E1655, ISO 12099, USP <857>, GLP/GMP-ready software architecture |
| Chemometrics Software | MEMS Quantitative Analysis Suite |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | N70 |
| Instrument Type | Laboratory FT-NIR Spectrometer |
| Principle | Fourier Transform Interferometry |
| Wavenumber Range | 3750–12500 cm⁻¹ |
| Scan Speed | <1 s (at 8 cm⁻¹ resolution) |
| Data Sampling Intervals | 2, 4, 8, or 16 cm⁻¹ |
| Measurement Modes | Integrating Sphere Diffuse Reflectance / Transflectance |
| Chemometrics Software | PLSQ — Partial Least Squares Spectral Modeling System |
| Detector | TEC-cooled InGaAs (2-stage thermoelectric cooling) |
| Resolution | <2 cm⁻¹ @ 7306.74 cm⁻¹ |
| Wavenumber Accuracy | <0.1 cm⁻¹ @ 7306.74 cm⁻¹ |
| Wavenumber Reproducibility | <0.04 cm⁻¹ @ 7306.74 cm⁻¹ |
| Inter-instrument Wavenumber Reproducibility | <0.05 cm⁻¹ @ 7306.74 cm⁻¹ |
| Absorbance Precision | ±0.1% T |
| Sample Measurement Time | <30 s |
| Dimensions | 445 × 237 × 320 mm |
| Weight | 20 kg |
| Power Consumption | 60 W |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | OS280 |
| Pricing | Upon Request |
| Measurement Principle | Capacitive Sensing of Total Polar Materials (TPM) |
| Temperature Range | 0–200 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±1 °C |
| TPM Range | 0–50% |
| TPM Accuracy | ±2% TPM |
| TPM Resolution | 0.1% |
| TPM Response Time | <10 s |
| Temperature Sensor | PTC |
| TPM Sensor | Patented Capacitive Sensor (Patent No.: ZL201310243911.2) |
| Display | Color LCD with Chinese UI |
| Operating Temp. | 0–50 °C |
| Storage Temp. | −40–70 °C |
| Enclosure Material | ABS Engineering Plastic |
| Probe Material | Food-Grade Stainless Steel (316) |
| IP Rating | IP65 |
| Power | Two AA Alkaline Batteries (1.5 V each) |
| Data Storage Capacity | 10,000 Records |
| Weight (with protective probe cap) | 218 g |
| Wireless Connectivity | Wi-Fi & Bluetooth |
| Probe Design | Quick-Release Modular Probe |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Product Type | Automated Polarimeter |
| Temperature Control | Integrated Peltier System |
| Display | 8-inch TFT Touchscreen (Android-based UI) |
| Light Source | LED (589.3 nm) |
| Measurement Range | ±89.99° |
| Minimum Resolution | 0.001° |
| Accuracy | ±0.01° (within ±45°), ±0.02° (outside ±45°) |
| Repeatability (SD) | 0.002° |
| Sample Transmittance Limit | ≥1% |
| Temp. Control Range | 10–50 °C |
| Temp. Accuracy | ±0.2 °C |
| Temp. Resolution | 0.1 °C |
| Data Storage | 8 GB internal |
| Compliance | FDA 21 CFR Part 11 audit trail, GLP/GMP-ready user management |
| Connectivity | 3× USB, RS232, Wi-Fi |
| Power | 220 V AC ±10%, 50 Hz, 250 W |
| Net Weight | 26 kg |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SH220F |
| Instrument Type | Graphite Block Digestion System |
| Automation Level | Fully Automatic |
| Digestion Positions | 30 |
| Temperature Range | Ambient +5 °C to 450 °C |
| Temperature Control Accuracy | ±1 °C |
| Heating Principle | Infrared Radiation + High-Purity Graphite Thermal Conduction |
| Reagent Channel Capacity | Up to 20 Samples Simultaneously |
| Display | 4.3-inch Color TFT LCD |
| Programmable Methods | 10 Predefined Multi-Stage Programs (up to 5 Temp/Time Segments Each) |
| Power Supply | 220 VAC ±10%, 50 Hz |
| Rated Power | 3.6 kW |
| Dimensions (L×W×H) | 515 mm × 421 mm × 211 mm |
| Net Weight | 25 kg |
| Safety Protections | Over-Temperature, Over-Current, Over-Voltage, Real-Time Heating Element Diagnostics |
| Graphite Block Treatment | CVD-Coated Surface for Oxidation Resistance |
| Housing Finish | PTFE-Impregnated Stainless Steel with Ceramic Fiber + Optimized Air-Channel Insulation |
| Exhaust Integration | Compatible with WD03 Acid Fume Extraction Unit and S402 Triple-Stage Neutralization System (Water Wash + NaOH Neutralization + Activated Carbon Adsorption) |
| Digestion Vessel Compatibility | 300 mL Borosilicate or Quartz Tubes (H₂O @ 20 °C) |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | SH230N |
| Instrument Type | Graphite Block Digestion System |
| Automation Level | Fully Automatic |
| Digestion Positions | 30 |
| Temperature Range | Ambient +5°C to 450°C |
| Temperature Control Accuracy | ±0.1°C |
| Heating Principle | Infrared Heating + High-Purity Graphite Thermal Conduction |
| Reagent Channels | 30 per batch |
| Insulation Material | Eco-Friendly Ceramic Fiber + Optimized Air-Channel Design |
| Digestion Vessels | Optional Borosilicate Glass (50 mL calibrated / 100 mL max) or PTFE (70 mL max) |
| Power Supply | 220 V AC ±10%, 50 Hz |
| Rated Power | 3.6 kW |
| Dimensions (L×W×H) | 515 × 421 × 211 mm |
| Net Weight | 22 kg |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | SH420F |
| Instrument Type | Graphite Block Digestion System |
| Automation Level | Fully Automatic |
| Sample Capacity | 20 positions |
| Temperature Range | Ambient +5°C to 450°C |
| Temperature Accuracy | ±1°C |
| Heating Principle | Infrared Radiation + High-Purity Graphite Thermal Conduction |
| Reagent Handling | Simultaneous digestion of 20 samples |
| Display | 5.6-inch full-color LCD touchscreen |
| Safety Features | Over-temperature, over-current, over-voltage protection with audible/visual alarm |
| Insulation | Ceramic barrier + optimized air-channel thermal isolation |
| Surface Finish | PTFE-coated corrosion-resistant housing |
| Cooling | Standard quick-cooling rack (manual post-digestion cooling) |
| Compliance | Designed for ISO/IEC 17025-compliant labs |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | SH520 / SH508 |
| Automation Level | Fully Automatic |
| Digestion Positions | 20 or 8 per batch |
| Temperature Range | Ambient +5°C to 450°C |
| Temperature Control Accuracy | ±1°C |
| Heating Principle | Electric Tubular Heater with Conductive Aluminum Block |
| Reagent Channels | 20 or 8 per batch |
| Digestion Vessels | 300 mL (SH520), 300/380 mL (SH508) |
| Power Rating | 2950 W (SH520), 1400 W (SH508) |
| Dimensions (L×W×H) | 305×590×151 mm (SH520), 328×440×151 mm (SH508) |
| Net Weight | 21 kg (SH520), 15 kg (SH508) |
| Data Connectivity | Wi-Fi & USB |
| Compliance | FDA 21 CFR Part 11–compliant audit trail and user permission management |
| Cooling | Optional motorized lift module with independent cooling rack |
| Exhaust Treatment | Integrated WD03 acid fume extraction system (standard) + optional S403 dual-mode (cooling + chemical neutralization) absorption unit |
| Housing | Electropolished stainless steel with PTFE-coated exterior |
| Storage | ≥8 GB internal flash memory |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | SOA100 |
| Detection Range | 0.1–50 mg |
| Detection Limit | ppm-level |
| Sample Throughput | 5–10 min/sample |
| Stirring Speed | 15–1500 rpm |
| Repeatability | RSD ≤ 1% |
| Distillation Time | 0–90 min |
| Cooling Water Consumption | 1.5 L/min |
| Display | 4.3-inch high-resolution color LCD |
| Rated Power | 1.3 kW |
| Input Voltage | 220 VAC ±10%, 50 Hz |
| Dimensions (L×W×H) | 400 × 385 × 735 mm |
| Net Weight | 30 kg |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | SOA600 |
| Type | Intelligent Automated SO₂ Distillation System |
| Max. Sample Capacity | 6 channels |
| Distillation Time Range | 1–999 min |
| N₂ Flow Rate | 50–2000 mL/min per channel |
| Distillation Flask Volume | 1000 mL |
| Power per Channel | 0–500 W |
| Total Rated Power | 3100 W |
| Dimensions (W×D×H) | 970 × 500 × 470 mm |
| Net Weight | 75 kg |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | SOX406 |
| Heating Method | Sealed Metal Bath |
| Temperature Range | Ambient +5 °C to 280 °C |
| Temperature Control Accuracy | ±1 °C |
| Channels | 6 |
| Receiver Flask Volume | 80 mL |
| Sample Weight Range | 0.5–15 g (typical: 2–5 g) |
| Solvent Recovery Rate | ≥80% |
| Power Supply | 220 VAC ±10%, 50 Hz |
| Rated Power | 1 kW |
| Dimensions (L×W×H) | 650 × 320 × 715 mm |
| Net Weight | 35 kg |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | SOX606 |
| Extraction Chamber Volume | 145 mL |
| Receiving Flask Volume | 150 mL |
| Temperature Range | Ambient +5°C to 300°C |
| Temperature Control Accuracy | ±1°C |
| Number of Channels | 6 |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | T860 |
| Instrument Type | General-purpose Potentiometric Titrator |
| Application Scope | Universal |
| Measurement Range | mV: −2000.0 to +2000.0 mV |
| pH | −20.000 to +20.000 pH |
| Temperature | −5 to 120 °C |
| Meter Accuracy | ±0.1 mV, ±0.003 pH, ±0.1 °C |
| High-Resolution Mode (Optional) | 0.05 mV, 0.0001 pH |
| Meter Resolution | 0.1 mV, 0.001 pH, 0.1 °C |
| Titration Accuracy | ±0.2% |
| Titration Resolution | 1/48,000 |
| Burette Options | Standard 10 mL |
| Burette Refill Time | 16 s (at 100% fill rate) |
| Stirring Method | Magnetic stirring |
| Electrode Interfaces | mV/pH input, reference electrode input, PT1000 temperature probe input |
| Communication Ports | 2× USB, RS232, power interface |
| Data Storage | 4 GB internal flash memory with multi-level search capability |
| User Management | Four-tier permission system with customizable access rights, electronic signature support, audit-trail-enabled data integrity controls, password policy enforcement (complexity, aging, expiration) |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | T910 |
| Instrument Type | Universal Potentiometric Titrator |
| Application Scope | General-purpose |
| Measurement Range | 0–300 mg KOH/100 g dry matter |
| mV Range | −2000.0 to +2000.0 mV |
| pH Range | −20.000 to +20.000 pH |
| Electrode Readout Accuracy | RSD ≤ 0.3% |
| Resolution | 0.01 mg KOH/100 g dry matter |
| Titration Resolution | 1/1,500,000 |
| Temperature Range | −5 to 120 °C |
| Temp. Accuracy | ±0.1 °C |
| Titration Tube Options | 1 mL / 5 mL / 10 mL / 25 mL |
| Refill Time (100% fill) | 16 s |
| Communication Interfaces | Dual USB, RS-232, Ethernet, CAN bus |
| Electrode Ports | mV/pH input, reference electrode port, PT1000 temperature probe port |
| Audit Trail | FDA 21 CFR Part 11 compliant |
| Electronic Signature | Supported |
| Data Integrity | Immutable export with checksum verification |
| User Management | Role-based, multi-level permissions |
| Sample Handling | Standalone station or optional auto-samplers (16×100 mL, 12×250 mL, 18×50 mL) |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | T930 |
| Titration Method | Fully Automated Volumetric Karl Fischer |
| Moisture Range | 0.001–100% (recommended: 0.1–100%) |
| Polarization Current Range | 1–24 µA |
| Polarization Current Resolution | 0.01 µA |
| Polarization Current Accuracy | ±0.05 µA |
| Voltage Range | 0–1999 mV |
| Voltage Resolution | 0.1 mV |
| Voltage Accuracy | ±0.2 mV |
| Titration Control Precision | 1/1,500,000 |
| Minimum Dispense Volume | 0.0001 mL |
| Standard Burette Capacity | 5 mL (optional: 1 mL or 10 mL) |
| Burette Accuracy | ±0.01 mL (1 mL), ±0.01 mL (5 mL), ±0.02 mL (10 mL) |
| Drift Resolution | 0.1 µg/min |
| Dynamic Delivery Rate | 0.02 µL/s to 0.1 mL/s (auto-switching) |
| Sample Cell Volume | 120 mL |
| Stirring | Integrated Magnetic Stirrer (manual/automatic modes) |
| Display | 10-inch capacitive TFT touchscreen |
| Data Storage | 8 GB internal flash memory |
| Export Formats | Excel, PDF |
| Communication Interfaces | Wi-Fi, USB, RS-232, BNC |
| Power Input | 100–240 V AC ±10%, 50–60 Hz |
| Compliance | FDA 21 CFR Part 11 (audit trail, role-based access control, electronic signatures) |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | T931 |
| Titration Method | Fully Automatic Coulometric Titration |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer |
| Moisture Measurement Range | 10 µg H₂O to 200 mg H₂O |
| Water Content Range | 0.0001%–100% (w/w) |
| Measurement Resolution | 0.001 µg H₂O (0.093 µg H₂O detection limit) |
| Current Resolution | 0.01 µA |
| Polarization Current Range | 1–24 µA |
| Polarization Current Accuracy | ±0.05 µA |
| Voltage Range | 0–1999 mV |
| Voltage Resolution | 0.1 mV |
| Voltage Accuracy | ±0.2 mV |
| Electrolysis Current Options | 1, 2, 5, 10, 20, 50, 100, 200, 400 mA |
| Max. Electrolysis Rate | 37.34 µg H₂O/s (2240 µg H₂O/min) |
| Titration Control Precision | 1/1,500,000 |
| Minimum Dispense Volume | 0.001 mL |
| Power Input | 100–240 V AC ±10%, 50–60 Hz |
| Output Voltage | 24 V DC |
| Data Storage | 8 GB internal flash memory |
| Display | 10-inch capacitive TFT touchscreen (Android-based UI) |
| Compliance | FDA 21 CFR Part 11, audit trail, four-tier user permission system, electronic signature, data integrity controls |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | T960 |
| Instrument Type | Universal Potentiometric Titrator |
| Application Scope | General-purpose |
| mV Measurement Range | −2000.0 mV to +2000.0 mV |
| mV Resolution & Accuracy | 0.1 mV resolution, ±0.1 mV ± 0.03% accuracy |
| pH Measurement Range | −20.000 to +20.000 pH |
| pH Resolution & Accuracy | 0.001 pH resolution, ±0.003 pH accuracy |
| Temperature Measurement Range | −5 °C to 120 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Resolution | 0.1 °C |
| Burette Resolution | 1/1,500,000 |
| Burette Volume Options | 1 mL / 5 mL / 10 mL / 25 mL |
| Auxiliary Reagent Channels | Up to 4+4 (8-channel synchronized dosing) |
| Electrode Interfaces | mV/pH, reference, PT1000 temperature, optional polarographic |
| Brand | Hanon |
|---|---|
| Origin | Shanghai, China |
| Model | UWave-2000 |
| Microwave Power | 0–1000 W (PID-controlled, non-pulsed continuous output) |
| Frequency | 2450 MHz (magnetron) |
| Temperature Control | Dual-mode (infrared: 0–300 °C, ±1 °C |
| Pt100 resistance probe | 0–250 °C, ±1 °C) |
| Pressure Control (sealed mode) | Piezoelectric sensor, 0–5 MPa, ±0.01 MPa |
| Max. Atmospheric Reaction Volume | 2000 mL (glass) |
| Max. Sealed Reaction Volume | 500 mL (stainless steel + PEEK/Quartz vessels) |
| Max. Sealed Operating Conditions | 230 °C, 2 MPa |
| Ultrasonic Module | Immersion-type, 0–800 W, 28 kHz, auto-sweep & frequency lock |
| UV Irradiation | Dual-source — standard 300 W @ 365 nm, optional 100 W @ 254 nm |
| Stirring | Dual-mode — magnetic (0–800 rpm), mechanical (30–1600 rpm, torque 300 N·m, PEEK or quartz shaft) |
| Safety Certification | ISO 9001:2008, CE compliant |
| Software | Windows-based PC interface with full parameter logging, real-time remote control, video capture, and audit-trail-capable data export |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Region | Domestic (China) |
| Model | W100 |
| Pricing | Available Upon Request |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Yundata |
| Instrument Category | Biological Degradation Air Purification System |
| Suitable Area | ≤60 m² |
| Noise Level | 55 dB(A) |
| Air Velocity | 7.4 m/s |
| Dimensions (W×D×H) | 542.6 × 320 × 577.5 mm |