Hanon
Filter
Showing 1–30 of 57 results
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | A630 |
| Instrument Type | Benchtop Refractometer |
| Temperature Control | Peltier-based |
| Digital Display | Yes |
| Refractive Index Range | 1.3000–1.7000 (nD) |
| Brix Accuracy | ±0.1% |
| nD Resolution | 0.0001 |
| Temperature Control Range | 10–50 °C |
| Temperature Stability | ±0.05 °C |
| Display | 7-inch capacitive touchscreen (Android OS) |
| Data Storage | 4 GB internal |
| Connectivity | 2× USB, RS232, Ethernet |
| Prism Material | Sapphire-grade optical glass |
| Light Source | >100,000 h LED |
| Compliance | FDA 21 CFR Part 11 (audit trail, user roles, electronic signature support) |
| Brand | Hanon |
|---|---|
| Model | A670 |
| Type | Benchtop Refractometer |
| Temperature Control | Peltier-based, 5–80 °C (±0.02 °C) |
| Display | 7-inch capacitive touchscreen (Android OS) |
| Measurement Range | 1.30000–1.70000 (nD) |
| Accuracy | ±0.0001 (nD) |
| Resolution | 0.0001 / 0.00001 (nD) selectable |
| Brix Range | 0–100.0% (±0.1%) |
| Light Source | >100,000 hr LED |
| Prism Material | Sapphire-grade optical glass |
| Data Storage | 4 GB internal + USB backup |
| Connectivity | 2× USB, RS232, Ethernet, Wi-Fi (A670 only) |
| Compliance | FDA 21 CFR Part 11 (user roles, audit trail, electronic signature, data integrity) |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | BS280CD |
| Chamber Volume | 180 L |
| Heating Power | 6 kW |
| Maximum Wash Temperature | 93 °C |
| Compatible Cleaning Agents | Acidic & Alkaline Liquid Detergents |
| External Dimensions (L×W×D) | 875 (845) × 900 × 710 mm |
| Brand | Hanon |
|---|---|
| Model | BS580D |
| Chamber Volume | 360 L |
| Heating Power | 9 kW |
| Maximum Wash Temperature | 93 °C |
| Wash Solution Compatibility | Acidic & Alkaline Liquid Detergents |
| External Dimensions (L×W×D) | 1800 × 785 × 765 mm |
| Power Supply | 380 V / 50 Hz (3-phase) |
| Control System | Programmable Logic Controller (PLC) with Touchscreen Interface |
| Wash Cycle Duration | Adjustable (Typical Range: 25–60 min) |
| Water Consumption per Cycle | ≤ 80 L |
| Drainage Capacity | ≥ 20 L/min |
| Safety Certification | CE-compliant design, IP54-rated electrical enclosure |
| Material of Chamber | 316L Stainless Steel |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | CEC400 |
| Sample Capacity | 4 positions |
| Max Sample Weight | ≤5 g per vessel |
| Acetate Buffer Dispensing Volume | ≤150 mL per step |
| Ethanol Dispensing Volume | ≤150 mL per step |
| Stirring Mode | Paddle-type agitation with programmable duration |
| Filtration | Vacuum-assisted, programmable duration & cycles |
| Cleaning | Rotational rinse, configurable cycles |
| Filtration Flask Volume | 500 mL |
| Power Rating | 320 W |
| Input Voltage | AC 220 V ±10%, 50/60 Hz |
| Dimensions (W×D×H) | 604 × 358 × 672 mm |
| Enclosure Material | Austenitic stainless steel with anti-fingerprint coating |
| Control Interface | External wall-mounted Android-based touchscreen panel |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | D200 |
| Analysis Principle | Dumas Combustion Method |
| Nitrogen Range | 0.1–500 mg |
| Sample Throughput | 3–4 min per sample |
| Repeatability | ≤0.5% RSD |
| Sample Mass | ≤1 g (solid) or ≤1 mL (liquid) |
| Recovery Rate | ≥99.5% |
| Power Consumption | 2000 W |
| Dimensions (L×W×H) | 735 mm × 560 mm × 560 mm |
| Detector | Thermal Conductivity Detector (TCD) |
| TCD Temperature Stability | ≤0.01 °C |
| Combustion Furnace Max Temp | 1200 °C |
| Carrier Gas | CO₂ (≥99.999% purity) |
| Oxygen Purity | ≥99.999% |
| Autosampler | 120-position single tray |
| Weight | 80 kg |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | D50 |
| Principle | Dumas Combustion Method |
| Nitrogen Range | 0.1–500 mg |
| Analysis Time | 3–4 min per sample |
| Repeatability | ≤0.5% RSD (using 150 mg of 10% N standard) |
| Sample Mass | ≤1 g (solid) or ≤1 mL (liquid) |
| Recovery Rate | >99.5% |
| Power Consumption | 2000 W |
| Dimensions (L×W×H) | 735 mm × 560 mm × 560 mm |
| Detector | Thermal Conductivity Detector (TCD) |
| Combustion Temperature | Up to 1200 °C |
| Carrier Gas | CO₂ (99.999% purity) |
| Oxygen Supply | High-purity O₂ (99.999%) |
| Autosampler Capacity | 1 × 60 positions |
| Calibration | Linear or user-defined non-linear curve |
| Communication Interface | RS485 (internal), RS232/USB (external) |
| Operating Environment | 15–30 °C, ≤85% RH |
| Weight | 80 kg |
| Brand | Hanon |
|---|---|
| Model | DF06 |
| Origin | Shandong, China |
| Type | Automated Enzymatic-Gravimetric Dietary Fiber Analyzer |
| Standards Compliance | GB 5009.88, GB/T 22224-2008, AOAC 985.29, AOAC 991.43 |
| Sample Capacity | 0.2–1 g per vessel |
| Throughput | 6 independent channels |
| Temperature Control Accuracy | ±1 °C |
| Repeatability (RSD) | ≤1% |
| Total Dietary Fiber (TDF) Assay Time | ~3.5 h |
| Insoluble (IDF) / Soluble (SDF) Fiber Assay Time | 1–3 h |
| Filtration Method | Vacuum-assisted membrane filtration (no backflush or external air supply) |
| Power Supply | AC 220 V ±10%, 50 Hz ±1 Hz |
| Rated Power | 1300 W |
| Dimensions (L×W×H) | 800 × 350 × 650 mm |
| Net Weight | 60 kg |
| Software Compliance | FDA 21 CFR Part 11–compliant user authentication and audit trail |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | E500 |
| Measured Elements | C, H, O, N, S |
| Analysis Time | 3–4 min per element |
| Detection Limits | ≤30 ppm for C/H/N/S (TCD), ≤20 ppm for O (NDIR) |
| Measurement Accuracy | Absolute error ≤0.1% (10 mg standard sample) |
| Sample Mass | Up to 1.5 g or 1 mL liquid |
| Detector Configuration | TCD for C/H/N/S |
| Combustion Temperature | Up to 1400 °C |
| Autosampler Capacity | 120-position ceramic crucible tray |
| Gas Requirements | He (99.999%), O₂ (99.999%) |
| Dimensions (L×W×H) | 735 × 560 × 1160 mm |
| Net Weight | 100 kg |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | F2000 |
| Sample Capacity | 24+ positions per batch |
| Temperature Control Accuracy | ±0.1°C |
| Repeatability | ≤0.5% RSD |
| Daily Throughput | ≥96 samples (4 batches) |
| Power Supply | AC 220±10 V, 50±1 Hz |
| Rated Power | 2000 W |
| Dimensions (L×W×H) | 520 × 450 × 510 mm |
| Net Weight | 52 kg |
| Compliance | GB/T 6434-2006, GB/T 20805-2006, GB/T 20806-2006, GB/T 5515-2008, GB/T 8310-2013, GB/T 5009.10-2003 |
| Brand | Hanon |
|---|---|
| Model | F800 |
| Origin | Shandong, China |
| Type | Semi-Automatic Fiber Analyzer |
| Compliance | GB/T 5515, GB/T 6434 |
| Sample Capacity | 6 samples/batch |
| Sample Weight Range | 0.5–3 g |
| Detection Range | 0.1–100% |
| Repeatability | ≤0.4% (for crude fiber <10%), ≤1% (for crude fiber ≥10%) |
| Heating Method | Integrated Infrared Heating |
| Preheating Time (Distilled Water) | 10–12 min |
| Boiling Time | 13–15 min |
| Rated Power | 2.2 kW |
| Voltage/Frequency | 220 VAC ±10%, 50 Hz |
| Dimensions | 776 × 476 × 644 mm |
| Optional Accessory | F800-B Cold Extraction Unit |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | FC1200 |
| Instrument Type | Integrated Circulating Chiller |
| Cooling Method | Water-Cooled |
| Temperature Control Range | 5.0–40.0 °C |
| Temperature Stability | ±0.3 °C |
| Refrigeration Capacity | 1200 W @ 20 °C |
| Circulating Pump Pressure | 0–1.5 bar (adjustable) |
| Flow Rate | 20 L/min |
| Reservoir Volume | 8 L |
| Operating Mode | Continuous |
| Refrigerant | R134a |
| Temperature Sensor | PT100 |
| Control Technology | PID + Hot-Gas Bypass |
| Display | Color LCD with 0.1 °C resolution |
| Dimensions | 550 × 400 × 644 mm |
| Power Supply | 220 VAC ±10%, 50 Hz |
| Max. Head | 15 m |
| Safety Features | Over/under-temperature alarm, low-level liquid detection with audible alert, flow interruption detection (auto-switch to internal recirculation) |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | FC1200E |
| Instrument Type | Integrated Circulating Chiller |
| Cooling Method | Water-Cooled |
| Temperature Control Range | −5.0 °C to Ambient |
| Refrigeration Capacity | 1200 W @ 20 °C |
| Temperature Stability | ±2 °C |
| Circulation Pump Pressure | 0–1.5 bar (adjustable) |
| Flow Rate | 20 L/min |
| Reservoir Volume | 6 L |
| Operating Mode | Continuous |
| Refrigerant | R134a |
| Temperature Sensor | PT100 |
| Display Resolution | 0.1 °C |
| Pump Head | 15 m |
| Dimensions (W×D×H) | 618 × 477 × 540 mm |
| Power Supply | 220 V AC ±10%, 50 Hz |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | FC1500 |
| Instrument Type | Constant-Temperature Bath |
| Circulation Mode | Internal & External |
| Temperature Control | Refrigeration & Heating |
| Bath Volume | 10 L |
| Temperature Range | 5 °C to 100 °C |
| Temperature Stability | ±0.05 °C |
| Display Resolution | 0.1 °C |
| Control Algorithm | Fuzzy PID |
| Sensor Type | PT100 |
| Heating Power | 2000 W |
| Refrigeration Capacity | 1500 W (at 20 °C ambient) |
| Refrigerant | R134a |
| Pump Flow Rate | 10 L/min |
| Pump Pressure | 0.35 bar |
| Dimensions | 555 mm × 350 mm × 750 mm |
| Weight | 40 kg |
| Power Supply | 220 VAC ±10%, 50 Hz |
| Operating Ambient | 10 °C–25 °C |
| Protection Features | Overcurrent, High/Low Temperature, Overtemperature, Low-Level Audible/Visual Alarm, Dry-Run Prevention |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | FC400 |
| Instrument Type | Integrated Circulating Chiller |
| Cooling Method | Water-Cooled |
| Temperature Control Range | 5°C to 100°C |
| Refrigeration Capacity | 400 W |
| Temperature Stability | ±0.3°C |
| Circulation Pump Pressure | 0.35 bar |
| Circulation Flow Rate | 10 L/min |
| Reservoir Volume | 4.5 L |
| Operating Mode | Continuous |
| Heating Power | 1000 W |
| Temperature Resolution | 0.1°C |
| Temperature Sensor | PT100 |
| Refrigerant | R134a |
| Power Supply | 220 V AC ±10%, 50 Hz |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | FCL35-20 |
| Instrument Type | Beer-Specific Accelerated Stability Testing System |
| Application | Laboratory-Based Shelf-Life Prediction |
| Temperature Range | 0–60 °C |
| Temperature Control Accuracy | ±0.05 °C |
| Display Resolution | ±0.01 °C |
| Bath Capacity | 35 L |
| Bath Opening Dimensions | 350 × 270 × 300 mm |
| Sample Capacity | 12 Bottles (adjustable basket) |
| Refrigeration Power | 1.05 kW (at 20 °C), 0.68 kW (at 0 °C), 0.35 kW (at −20 °C) |
| Heating Power | 2 kW |
| Pump Pressure Range | 0–0.8 bar |
| Pump Flow Rate | 0–20 L/min |
| Power Supply | 220 V AC ±10%, 50 Hz |
| Ambient Operating Temperature | 5–40 °C |
| Dimensions (L×W×H) | 640 × 440 × 740 mm |
| Weight | 50 kg |
| Touchscreen | 7-inch Color LCD with Capacitive Touch |
| Connectivity | Dual-band 2.4/5 GHz Wi-Fi Module |
| Compliance | Designed for ASTM E2041, ISO 11348, and internal brewery QC protocols requiring accelerated aging under controlled thermal cycling |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | FCLW6-20 |
| Bath Volume | 6 L |
| Temperature Range | -20 °C to 100 °C |
| Temperature Stability | ±0.05 °C |
| Display Resolution | 0.1 °C |
| Pump Flow Rate | 10 L/min |
| Pump Pressure | 0.35 bar |
| Heating Power | 1000 W |
| Cooling Power | 250 W |
| Refrigerant | R134a |
| Temperature Sensor | PT100 |
| Control Algorithm | Fuzzy PID |
| Circulation Mode | Internal & External |
| Protection Features | Over-current, High/Low Temperature, Over-temperature, Low-level Audio-Visual Alarm |
| Power Supply | 220 V AC ±10%, 50 Hz |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | i2 |
| Optical Design | Double-beam |
| Detector | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.1 nm (at D₂ line, 656.1 nm), ±0.3 nm across full range |
| Wavelength Repeatability | ≤0.2 nm |
| Spectral Bandwidth | 0.5 / 1 / 2 / 4 / 5.0 nm (selectable) |
| Stray Light | ≤0.03% T |
| Wavelength Scanning | Automatic |
| A/D Resolution | 24-bit |
| Data Storage | 200 measurement sets + 200 calibration curves |
| Baseline Flatness | ±0.001 A |
| Photometric Accuracy | ±0.3% T |
| Photometric Repeatability | ≤0.15% T |
| Drift | ±0.001 A/h at 500 nm |
| Noise | ±0.0005 A/h |
| Photometric Range | 0–200% T, –0.3 to 3 A, 0–9999 C |
| Display | 128 × 64 LCD |
| Interface | USB port for data export |
| Power Supply | AC 220 V/50 Hz or 110 V/60 Hz |
| Dimensions | 460 × 380 × 180 mm |
| Weight | 15 kg |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | i3 |
| Optical Design | Double-beam |
| Detector | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Spectral Bandwidth | 0.5 / 1 / 2 / 4 / 5.0 nm |
| Wavelength Accuracy | ±0.1 nm (at D₂ line, 656.1 nm), ±0.3 nm across full range |
| Wavelength Repeatability | ≤0.3 nm |
| Stray Light | ≤0.03% T |
| Wavelength Setting | Automatic |
| Photometric Range | 0–200% T, –0.3–3 A, 0–9999 C |
| Photometric Accuracy | ±0.5% T |
| Photometric Repeatability | ≤0.2% T |
| Baseline Stability | ±0.001 A/h at 500 nm |
| Display | 128×64 dot-matrix LCD |
| Data Interface | USB |
| Printer Interface | Parallel port |
| Light Sources | Imported deuterium and tungsten lamps |
| Power Supply | AC 220 V/50 Hz or 110 V/60 Hz |
| Dimensions | 420 × 300 × 160 mm |
| Weight | 13 kg |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | i5 |
| Optical Design | Double-beam |
| Detector | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.1 nm (at D₂ line, 656.1 nm), ±0.3 nm across full range |
| Wavelength Repeatability | ≤0.2 nm |
| Spectral Bandwidth | 0.5 / 1 / 2 / 4 / 5.0 nm (selectable) |
| Stray Light | ≤0.03% T |
| A/D Resolution | 24-bit |
| Baseline Flatness | ±0.001 A |
| Photometric Accuracy | ±0.3% T |
| Photometric Repeatability | ±0.15% T |
| Drift | ≤0.001 A/h (at 500 nm) |
| Noise | ≤0.0005 A |
| Photometric Range | 0–200% T, –0.3 to 3 A, 0–9999 C |
| Wavelength Setting | Automatic |
| Scan Speed | High/Medium/Low (user-selectable) |
| Display | 320 × 240 LCD |
| Light Sources | Imported Deuterium & Tungsten Lamps |
| Power Supply | AC 220 V/50 Hz or 110 V/60 Hz |
| Dimensions | 460 × 380 × 180 mm |
| Weight | 20 kg |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | i6 |
| Optical Design | Double-beam |
| Detector Type | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.1 nm at D₂ line (656.1 nm), ±0.3 nm across full range |
| Wavelength Repeatability | ≤0.1 nm |
| Spectral Bandwidth | 0.5 / 1 / 2 / 4 / 5.0 nm (selectable) |
| Stray Light | ≤0.03% T |
| Photometric Accuracy | ±0.2% T |
| Photometric Repeatability | ±0.15% T |
| Baseline Flatness | ±0.001 A |
| Drift | ≤0.001 A/h at 500 nm |
| Noise Level | ≤0.0005 A |
| Photometric Range | 0–200% T, –4.0 to +4.0 A, 0–9999 C |
| Wavelength Setting | Automatic |
| Scan Speed | High/Medium/Low (3-step selectable) |
| A/D Resolution | 24-bit |
| Display | 320 × 240 LCD |
| Light Sources | Imported deuterium lamp & tungsten-halogen lamp |
| Power Supply | AC 220 V/50 Hz or 110 V/60 Hz |
| Dimensions | 470 × 370 × 180 mm |
| Weight | 20 kg |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | i7 |
| Optical Design | Double-beam |
| Detector | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.1 nm at 656.1 nm (D₂ line), ±0.3 nm across full range |
| Wavelength Repeatability | ≤0.1 nm |
| Spectral Bandwidth | 0.5 / 1.0 / 2.0 / 4.0 / 5.0 nm (user-selectable) |
| Stray Light | ≤0.03% T |
| Photometric Accuracy | ±0.2% T |
| Photometric Repeatability | ±0.15% T |
| Baseline Flatness | ±0.001 A |
| Drift | ≤0.001 A/h at 500 nm |
| Noise | ≤0.0005 A |
| Photometric Range | 0–200% T, –4.0 to +4.0 A, 0–9999 C |
| Wavelength Setting | Automatic |
| Scan Speed | High/Medium/Low (3 modes) |
| A/D Resolution | 24-bit |
| Display | 320 × 240 LCD |
| Light Sources | Imported Tungsten and Deuterium Lamps |
| Detector Type | Imported Silicon Photodiode |
| Power Supply | AC 220 V/50 Hz or 110 V/60 Hz |
| Dimensions | 470 × 370 × 180 mm |
| Weight | 20 kg |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | i8 |
| Optical System | Dual-beam |
| Detector | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.1 nm (at D₂ line, 656.1 nm), ±0.3 nm across full range |
| Wavelength Repeatability | ≤0.1 nm |
| Spectral Bandwidth | 1.8 nm |
| Stray Light | ≤0.03% T |
| Photometric Accuracy | ±0.2% T |
| Photometric Repeatability | ≤0.15% T |
| Baseline Flatness | ±0.001 A |
| Drift | ≤0.0004 A/h (at 500 nm) |
| Noise | ≤0.0005 A |
| Photometric Range | 0–200% T, –4.0 to +4.0 A, 0–9999 C |
| Wavelength Setting | Automatic |
| Scan Speed | High/Medium/Low selectable |
| Data Interface | USB |
| Display | 320 × 240 pixel LCD |
| Light Sources | Imported tungsten and deuterium lamps |
| Detector Type | Imported silicon photodiode |
| Power Supply | AC 220 V/50 Hz or 110 V/60 Hz |
| Dimensions | 625 × 430 × 210 mm |
| Weight | 28 kg |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | i9 |
| Optical System | Dual-beam |
| Detector | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.1 nm @ 656.1 nm (D₂ line), ±0.3 nm across full range |
| Wavelength Repeatability | ≤0.1 nm |
| Spectral Bandwidth | 0.5 / 1.0 / 2.0 / 4.0 / 5.0 nm (motorized, user-selectable) |
| Stray Light | ≤0.03% T |
| Photometric Accuracy | ±0.2% T |
| Photometric Repeatability | ≤0.15% T |
| Baseline Flatness | ±0.001 A |
| Drift | ±0.0004 A/h @ 500 nm |
| Noise | ±0.0005 A |
| Photometric Range | 0–200% T, –4.0 to +4.0 A, 0–9999 C |
| Wavelength Setting | Automatic |
| Scan Speed | High/Medium/Low (3 modes) |
| Data Interface | USB |
| Display | 320 × 240 pixel LCD |
| Light Sources | Imported deuterium and tungsten lamps |
| Detector | Imported silicon photodiode |
| Power Supply | AC 220 V/50 Hz or 110 V/60 Hz |
| Dimensions | 625 × 430 × 210 mm |
| Weight | 28 kg |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | K1100 |
| Instrument Type | Kjeldahl Nitrogen Analyzer |
| Automation Level | Fully Automated |
| Nitrogen Determination Range | 0.1–240 mg N |
| Sample Weight Capacity | ≤5 g (solid), ≤20 mL (liquid) |
| Repeatability | ≤0.5% RSD |
| Recovery Rate | ≥99.5% |
| Steam Generation Control | Adjustable flow with real-time distillate temperature monitoring |
| Distillation Time | Programmable |
| Titration Resolution | 1.0 µL/step |
| Cooling Water Consumption | 1.5 L/min |
| Data Storage Capacity | 1800 test records |
| Power Supply | 220 V AC ±10%, 50 Hz |
| Rated Power | 2 kW |
| Dimensions (L×W×H) | 455 mm × 391 mm × 730 mm |
| Net Weight | 38 kg |
| Compliance | GB, NY, HJ, Chinese Pharmacopoeia, AOAC Official Methods, ISO 8968 & ISO 5983 |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | K1160 + K1124 |
| Instrument Type | Fully Automated Kjeldahl Nitrogen Analyzer |
| Nitrogen Determination Range | 0.1–240 mg N |
| Distillation Time | 2.8–3 min per sample |
| Repeatability (RSD) | ≤0.5% |
| Sample Weight Capacity | ≤5 g (solid), ≤20 mL (liquid) |
| Nitrogen Recovery Rate | ≥99.5% |
| Titration Resolution | 0.2 / 0.4 / 1.0 µL/step (selectable) |
| Power Consumption | 2 kW |
| Dimensions (L×W×H) | 460 × 360 × 725 mm |
| Net Weight | 38 kg |
| K1124 Autosampler | 24-position, 300 mL digestion tube capacity, integrated CAN interface, 24 VDC, 40 W, 920 × 625 × 908 mm, 80 kg |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | K9840 |
| Nitrogen Determination Range | 0.1–240 mg N |
| Distillation Time | 0–60 min |
| Repeatability | ±0.5% |
| Sample Weight Capacity | ≤6 g (solid) / ≤16 mL (liquid) |
| Nitrogen Recovery Rate | ≥99.5% |
| Power Consumption | 1.3 kW |
| Dimensions (L×W×H) | 400 × 385 × 735 mm |
| Net Weight | 30 kg |
| Compliance | GB, NY, HJ, Chinese Pharmacopoeia, AOAC Official Methods, ISO 8968 & ISO 5983 |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | K9860 |
| Nitrogen Determination Range | 0.1 mg – 200 mg |
| Distillation Time | 5–10 min per sample |
| Repeatability | ±0.5% RSD |
| Sample Weight Capacity | ≤5 g (solid), ≤20 mL (liquid) |
| Nitrogen Recovery Rate | ≥99.5% |
| Power Consumption | 2 kW |
| Dimensions (L×W×H) | 455 mm × 391 mm × 730 mm |
| Touchscreen | 5.6-inch color LCD |
| Titration Resolution | 2.0 µL/step |
| Cooling Water Flow | 1.5 L/min |
| Data Storage | 1000 methods/results |
| Voltage | 220 VAC ±10%, 50 Hz |
| Net Weight | 38 kg |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | MP360 |
| Temperature Range | 0–100 °C |
| Heating Rate | 0.1–20.0 °C/min |
| Temperature Repeatability | ±0.2 °C (at 0.20 °C/min) |
| Temperature Accuracy | ±0.3 °C |
| Capillary Dimensions | ID 0.9–1.1 mm, Wall Thickness 0.10–0.15 mm (optional 1.6 mm OD) |
| Sample Capacity | 3 samples per run |
| Temperature Resolution | 0.1 °C |
| Data Storage | 32 GB internal |
| Video Storage | ~10,000 minutes (H.264 encoded) |
| Compliance | FDA 21 CFR Part 11, ASTM D3104, GB/T 24892–2010, GB/T 12766–2008, SN/T 0801.5–1999 |
| Connectivity | USB ×3, RS-232, Wi-Fi, RJ45 Ethernet |
| Calibration | Multi-point temperature calibration |
| User Management | Role-based access control with audit trail |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | MP420 |
| Temperature Range | Ambient to 300 °C |
| Heating Rate | 0.1–20 °C/min |
| Temperature Repeatability | ±0.2 °C (at 0.20 °C/min) |
| Temperature Accuracy | ±0.4 °C (<200 °C), ±0.7 °C (<300 °C) |
| Capillary Dimensions | Sealed-end, OD 1.3–1.4 mm, L 110 mm |
| Sample Capacity | 4 samples per run |
| Temperature Resolution | 0.1 °C |
| Display | 8-inch capacitive TFT touchscreen (Android OS) |
| Camera | 720p HD, 8× optical zoom |
| Data Storage | 16 GB internal (expandable via USB) |
| Compliance | FDA 21 CFR Part 11 (audit trail, user permission tiers, password policy, electronic signature support) |