HEL (UK)
Filter
Showing all 12 results
| Brand | HEL (UK) |
|---|---|
| Origin | United Kingdom |
| Model | CrystalEYES |
| Temperature Range | −40 °C to 200 °C |
| Detection Principle | Near-Infrared (NIR) Laser Turbidity Sensing |
| pH Monitoring | Integrated Auto-Logging |
| Data Output | CSV/Excel-Compatible Export |
| Software | Real-Time Graphical Acquisition & MSZW Analysis Module |
| Compliance | Designed for GLP/GMP-Aligned Process Development Environments |
| Brand | HEL (UK) |
|---|---|
| Origin | United Kingdom |
| Model | AutoLAB & AutoLAB Custom |
| Reactor Volume | 500 mL – 5 L |
| Material | Borosilicate Glass (Pyrex®), Stainless Steel, Corrosion-Resistant Alloys |
| Operating Pressure | Up to 200 bar (customizable) |
| Configuration | 1–8 parallel reactors |
| Modular PAT Integration | Yes |
| Software | WinISO v6.x (FDA 21 CFR Part 11 compliant, audit trail enabled) |
| Temperature Control Range | −80 °C to +250 °C (dependent on jacketed reactor & circulator) |
| Stirring | Independent digital torque-controlled overhead stirring per reactor |
| Automation Level | Fully programmable multi-parameter sequence control (T, P, agitation, dosing, sampling, pH, spectroscopy) |
| Brand | HEL (UK) |
|---|---|
| Origin | United Kingdom |
| Model | AutoMATE 4 |
| Reactor Type | Modular Parallel Reactor System |
| Volume Range | 10–1000 mL |
| Pressure Rating | Up to 200 bar (customizable) |
| Temperature Range | −80 °C to 250 °C |
| Control Precision | ±0.1 °C |
| Stirring Options | Magnetic, Overhead Mechanical, or Dual-mode |
| Liquid Dosing Accuracy | ±0.1% (volumetric), ±0.01 g (gravimetric) |
| Gas Dosing | Mass Flow Controlled |
| Vacuum Capability | Up to 10 MPa (absolute) |
| Construction Materials | 316 stainless steel, Hastelloy®, inert polymer seals, Pyrex® glass vessels |
| Compliance | Designed for GLP/GMP environments |
| Brand | HEL (UK) |
|---|---|
| Origin | United Kingdom |
| Model | AutoMATE High Pressure & AutoMATE Custom |
| Reactor Type | Tubular & Batch Reactor |
| Working Volume | 10–1000 mL |
| Operating Pressure | 0–10 MPa (0–100 bar, configurable up to 200 bar) |
| Temperature Range | −80 °C to 250 °C (oil bath), up to 500 °C with external circulator |
| internal heating | RT to 250 °C |
| Stirring Options | Magnetic, overhead mechanical, or dual-mode |
| Stirring Speed | 0–2000 rpm (magnetic: max torque 800 N·cm |
| overhead | max torque 80 N·cm) |
| Liquid Dosing | HPLC-grade precision pump (0.01–50 mL/min, high-pressure) |
| Gas Dosing | Mass flow controller (MFC), pressure-regulated, or volumetric metering |
| Solid Dosing | Auger feeder (350/500 mL capacity) |
| Interface Ports | Up to 5 per reactor head (customizable) for probes (pH, FTIR, turbidity, particle size), condensers, sampling, and reagent addition |
| Compliance | Designed for GLP/GMP environments |
| Brand | HEL (UK) |
|---|---|
| Origin | United Kingdom |
| Model | CAT 7 / CAT 18 / CAT 24 |
| Max. Operating Pressure | 100 bar |
| Max. Operating Temperature | 300 °C |
| Catalyst Bed Volume | 10 mL |
| Vessel Material | 316 Stainless Steel or Hastelloy® Alloy |
| Sample Capacity Options | 2–10 mL per vessel |
| Heating Method | External (hotplate, oil bath, or PolyBlock™ heater block) |
| Stirring | Magnetic stirring integrated |
| Temperature Monitoring | Integrated micro thermocouple |
| Cooling Option | Finger-type condenser (CAT 7 & CAT 24 only) |
| HPLC Vial Compatibility | 2 mL vials (CAT 18 only) |
| Purge & Pressurization | Manual valve-controlled inert gas purge and reactant gas pressurization (e.g., H₂) |
| Brand | HEL (UK) |
|---|---|
| Origin | United Kingdom |
| Model | ChemSCAN & ChemSCAN Custom |
| Operating Pressure | 200 bar |
| Operating Temperature | −60 °C to 200 °C |
| Catalyst Bed Volume | 120 mL |
| Reactor Configuration | 8 independently controlled parallel reactors |
| Standard Vessel Capacity | 16 mL |
| Optional Vessel Capacities | 25 mL, 50 mL, 75 mL, 120 mL, 160 mL, 300 mL, 400 mL |
| Stirring Options | Magnetic suspension stirring, overhead mechanical stirring (optional), stir-controlled per reactor |
| Gas Consumption Monitoring | Real-time, reactor-specific calculation |
| Liquid Dosing | Optional automated high-pressure liquid injection |
| Compliance | Designed for GLP/GMP-aligned R&D environments |
| Brand | HEL (UK) |
|---|---|
| Origin | United Kingdom |
| Model | CrystalSCAN & CrystalSCAN Custom |
| Reactor Type | Parallel Batch Crystallization Reactor |
| Construction Material | Stainless Steel (316 SS) |
| Operating Pressure | Up to 20 bar (High-Pressure Capable) |
| Working Volume Range | 2–500 mL |
| Temperature Range | –80 °C to +250 °C |
| Number of Independent Reaction Zones | 4 or 8 |
| Stirring Method | Suspended Mechanical Impeller (configurable) / Magnetic Stirring (for small vials) |
| Max. Viscosity Handling | 1000 cP |
| Compliance | Designed for GLP/GMP-aligned process development environments |
| Software Control | Integrated PC-based control with real-time data logging and audit trail capability |
| Brand | HEL (UK) |
|---|---|
| Origin | United Kingdom |
| Model | HP Simular |
| Measurement Mode | Adiabatic Calorimetry |
| Instrument Type | Reaction Calorimeter |
| Automation | Fully Automated |
| Temperature Range | −30 °C to 210 °C |
| Temperature Resolution | 0.2 mK |
| Temperature Precision | ±0.1 K |
| Heat Capacity Range | ±750 J/K |
| Maximum Pressure | 100 bar (upgradable to 200 bar) |
| Vessel Volume Options | 0.5 L, 1 L, 2 L |
| Vessel Materials | 316 Stainless Steel or Hastelloy C-276 |
| Stirring System | PTFE-coated shaft with 4-blade PTFE impeller (45–60° pitch) |
| Pressure Relief | Swagelok 316SS PRV + dial pressure gauge |
| Integrated Sensors | Temperature, pressure, optional in situ FTIR/Raman/turbidity/particle size |
| Calibration Heater | 150 W power-compensation heater |
| Control Software | HEL ChemScan™ with PAT integration, audit trail, and 21 CFR Part 11 compliance support |
| Brand | HEL (UK) |
|---|---|
| Origin | United Kingdom |
| Model | PolyCAT 4, PolyCAT 8 |
| Maximum Operating Pressure | 200 bar |
| Maximum Operating Temperature | 550 °C |
| Catalyst Bed Volume | 30 mL |
| Reactor Volume | 16 mL (standard) |
| Temperature Control Range | 25–250 °C (inter-reactor ΔT ≤ 100 °C) |
| Liquid Feed Rate | 0.001–10 mL/min or 0.01–50 mL/min |
| Gas Feed | Mass-flow controlled (e.g., H₂), continuously adjustable |
| Configuration Options | 4-channel parallel or 8-channel parallel |
| Brand | HEL (UK) |
|---|---|
| Origin | United Kingdom |
| Model | Simular 10L/20L |
| Calorimetry Mode | Adiabatic |
| Instrument Type | Reaction Calorimeter |
| Automation | Fully Automated |
| Temperature Range | −30 °C to 225 °C |
| Temperature Resolution | 0.2 mK |
| Temperature Precision | ±0.1 K |
| Maximum Jacket Pressure | 100 bar |
| Heat Capacity Range | ±750 J/K |
| Vessel Materials | Borosilicate Glass, 316 Stainless Steel, Hastelloy C-276 |
| Compatible PAT Interfaces | FTIR, Raman, pH, DO, ORP, Turbidity, Pressure, Temperature |
| Brand | HEL (UK) |
|---|---|
| Origin | United Kingdom |
| Model | Tandem MULTI |
| Construction Material | Stainless Steel |
| Operating Pressure | Low-Pressure System |
| Working Volume | 5 L |
| Vacuum Range | 0–1 MPa |
| CO₂ Measurement Principle | Non-Dispersive Infrared (NDIR) Absorption |
| O₂ Measurement Principle | Electrochemical Sensor |
| CO₂ Range Options | 5%, 10%, 20%, 50%, 60%, 100% |
| O₂ Range Options | 25%, 30%, 50%, 60%, 100% |
| CO₂/O₂ Resolution | 0.01% |
| Accuracy | ±2% of Full Scale |
| Drift | <0.05% FS/month |
| Response Time (T90) | <50 s (CO₂), <10 s (O₂) |
| Sample Flow Rate | 25–1000 mL/min |
| Operating Temperature | 0–45 °C |
| Temperature Compensation | Integrated |
| Output Signals | Dual 0–10 V and 4–20 mA analog outputs |
| Digital Interface | RS232 |
| Internal Sampling Pump | Yes |
| Local Display | Yes |
| Calibration | Manual and Auto-calibration support |
| Channel Capacity | Up to 12 multiplexed gas streams |
| Sampling Interval | User-definable from 30 seconds |
| Compliance | Designed for GLP/GMP-aligned bioprocess environments |
| Software Integration | Compatible with SCADA, DCS, and LabVIEW via RS232 and analog I/O |
| Brand | HEL (UK) |
|---|---|
| Origin | United Kingdom |
| Model | Tandem PRO |
| Construction Material | Stainless Steel |
| Operating Pressure | Low-Pressure System |
| Vessel Capacity | 5 L |
| Vacuum Range | 0–1 MPa |
| Gas Measurement | CO₂ (IR Absorption), O₂ (Electrochemical Sensor) |
| CO₂ Range Options | 5%, 10%, 20%, 50%, 60%, 100% |
| O₂ Range Options | 25%, 30%, 50%, 60%, 100% |
| Resolution | 0.01% (both gases) |
| Accuracy | ±2% of Full Scale |
| Drift | <0.05% FS/month |
| Response Time (T90) | <50 s (CO₂), <10 s (O₂) |
| Flow Rate | 25–1000 mL/min |
| Operating Temperature | 0–45 °C |
| Temperature Compensation | Integrated |
| Local Display | Yes |
| Calibration | Manual & Auto |
| Internal Sample Pump | Yes |
| Analog Outputs | Dual 0–10 V and 4–20 mA |
| Digital Interface | RS232 |
| Compatibility | Scalable from lab-scale (250 mL) to industrial bioreactors (up to 100 m³) |