Honeywell
Filter
Showing all 23 results
| Brand | Honeywell |
|---|---|
| Model | Flex4 |
| Origin | USA |
| Sensor Options | Up to 15 interchangeable sensors |
| Simultaneous Gas Detection | 4 gases |
| Display | High-resolution multi-language (English/Chinese) LCD |
| Communication | Bluetooth Low Energy (BLE) |
| Certifications | ATEX, IEC Ex, ABS, CNEx, CPA, MA, CCS |
| IP Rating | IP66/IP68 |
| Operating Temperature | –40°C to 60°C (catalytic LEL: –20°C to 60°C) |
| Battery Life | 40 days (IR LEL, 8 hrs/day) or 15 hrs (catalytic LEL) |
| Dimensions | 108.2 × 61.5 × 43.2 mm (with clip) |
| Weight | 186 g (IR LEL) / 189 g (catalytic LEL), with clip |
| Alarm Types | Visual (LED), Vibration, Audible (95 dB), TWA/STEL/Low/High/Negative Drift/Over-range |
| Compliance | Meets OSHA, NIOSH, and ISO 9001 manufacturing standards |
| Brand | Honeywell |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | BW Solo |
| Pricing | Available Upon Request |
| Brand | Honeywell |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | BW™ Ultra |
| Pricing | Upon Request |
| Brand | Honeywell |
|---|---|
| Model | FMC-1000Plus (Panel-Mount) / FMC-1000Plus-W (Wall-Mount) |
| Origin | USA |
| Input Signal | 4–20 mA (2-wire/3-wire gas detectors) |
| Output Signal | 4–20 mA per channel (optional) |
| Power Supply | 24 VDC, 5 A (controller) |
| Operating Temperature | −20 °C to +50 °C |
| Relative Humidity | 0–99% RH (non-condensing) |
| Display | 96×128 dot-matrix LCD with backlight (main controller) |
| Alarm Outputs | 3 relay contacts per channel (High/Low/Fault), 220 VAC, 5 A |
| Communication | RS-485 Modbus RTU |
| Compliance | GB 16808–2008, CCS Certified |
| Dimensions (Panel) | 177 × 482.6 × 82 mm (H×W×D) |
| (Wall) | 246 × 660 × 58.6 mm (H×W×D) |
| Weight | 15 kg (16-channel), 10 kg (4-channel) |
| Brand | Honeywell |
|---|---|
| Origin | USA |
| Model | HMS-FD-3IR |
| Explosion Protection Rating | Ex d IIC T6 Gb / Ex tD A21 IP66 T80°C |
| Optical Spectral Range | 3.8–5.0 µm |
| Field of View | 90° conical (±45° from optical axis) |
| Sensitivity Levels | 4 adjustable (Level I–IV, default Level II) |
| Response Time | 3–5 s to 0.1 m² n-heptane flame at 60 m |
| Operating Voltage | DC 18–30 V (nominal 24 V DC) |
| Current Consumption | <35 mA @ 24 V DC |
| Output Options | Relay (dry contact), 0–20 mA analog, HART®, MODBUS RTU, fire alarm system bus interface |
| Enclosure Material | Aluminum alloy (copper-free, epoxy-painted) or optional 316 stainless steel |
| Weight | 2.0 ± 0.2 kg (aluminum), 5.0 ± 0.2 kg (stainless steel) |
| IP Rating | IP66 |
| Operating Temperature | −40 °C to +70 °C |
| Relative Humidity | ≤95% RH (non-condensing) |
| Certifications | CCCF, ATEX, IECEx, UL/cUL Listed for Class I, Div 1, Groups B, C, D |
| Brand | Honeywell |
|---|---|
| Model | HPA |
| Origin | USA |
| Type | Barometric Altimeter |
| Pressure Range | 0–17.6 psia |
| Operating Temperature | −40 °C to +85 °C |
| Accuracy | ±0.03 psia or ±0.06% FSO |
| Long-Term Drift | ≤0.02% FSO/year |
| Output Interface | TTL-compatible digital output |
| Form Factor | Compact, low-mass package |
| Compliance | RoHS-compliant, designed for aerospace and industrial altitude referencing applications |
| Brand | Honeywell |
|---|---|
| Model | HPB |
| Measurement Range | 500–1200 hPa |
| Operating Temperature | −40 °C to +85 °C |
| Accuracy | ±0.4 hPa or ±0.8 hPa (typ.) |
| Long-Term Drift | ≤0.25 hPa/year |
| Output Interface | TTL-compatible digital output |
| Power Consumption | Low-power design |
| Form Factor | Compact and lightweight |
| Origin | USA |
| Supply Chain Status | Imported via authorized distributor |
| Key | Brand: Honeywell |
|---|---|
| Origin | USA |
| Model | LP-1200 |
| Type | Manual piston sampling pump (not a standalone gas analyzer) |
| Compatible With | Standard-length colorimetric gas detection tubes (e.g., Honeywell, Dräger, Gastec) |
| Sampling Volumes | 50 mL or 100 mL per stroke |
| Sealing Mechanism | Plug-type vacuum seal cylinder with conical rubber inlet tip |
| Visual Indicators | Gray-to-white window transition during sampling |
| Leak Check Procedure | Built-in 2-minute vacuum hold test (≤3 mm piston drift) |
| Maintenance | Replaceable rubber inlet tip, washable/replacement inlet filter, vacuum-lubricated piston assembly, serviceable one-way valve |
| Brand | Honeywell |
|---|---|
| Origin | USA |
| Model | MicroRAE |
| Instrument Type | Portable |
| Detectable Gases | O₂, LEL (Combustible Gas), CO, H₂S |
| Response Time | 15 s |
| Measurement Accuracy | ±1 ppm (for CO and H₂S in low-range mode) |
| Measurement Ranges | 0–30.0% VOL (O₂), 0–100% LEL (Combustibles), 0–1,000 ppm (CO), 0–100 ppm (H₂S) |
| IP Rating | IP67 |
| Operating Temperature | −40 °C to +70 °C (2 hr at extremes), −20 °C to +60 °C (continuous) |
| Battery Life | 15 h (non-wireless), 11 h (wireless active) |
| Wireless Protocols | Proprietary RAE Mesh, Bluetooth Low Energy (BLE), optional integrated GPS |
| Certifications | IECEx Ex ia d II C T4 Gb, China Ex d ia II C T4 Gb, CMC, CCCF |
| Calibration | Dual-point (manual or AutoRAE 2 automated) |
| Data Logging | Continuous, configurable interval (1–3600 s), 6-month storage (1-min intervals across all 4 sensors) |
| Brand | Honeywell |
|---|---|
| Origin | USA |
| Model | OGIRAE 3000 |
| Detection Range | >400 VOCs including methane, ethanol, gasoline, benzene, and other volatile organic compounds |
| Spectral Band | 3.2–3.5 µm |
| Detector Type | Cooled Type-II Strained-Layer Superlattice (T2SL) Mid-Wave Infrared (MWIR) Focal Plane Array |
| Cooling | Integrated Stirling cooler |
| Compliance | Meets ASTM D7520–22 (Standard Practice for Optical Gas Imaging), EPA OOOOa / OOOOb compliance support, ATEX/IECEx Zone 1 certified (per datasheet) |
| Weight | <3.2 kg |
| Display | Rotatable 4.3″ OLED touchscreen |
| Data Output | MP4 video, JPEG stills, WAV audio with embedded GPS & thermal metadata |
| Brand | Honeywell |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PGM-2400 |
| Price Range | USD 700 – 1,400 (FOB) |
| Gas Options | H₂S, CO |
| Operating Life | ≥24 months (typical), up to 36 months under optimal conditions |
| Environmental Rating | IP67 |
| Operating Temperature Range | –20 °C to +50 °C |
| Display | Backlit LCD with real-time gas concentration, battery level, and status icons |
| Alarm Types | Visual (LED flash), Vibration, 95 dB audible |
| Calibration Interval | User-configurable |
| Communication | Infrared (IrDA) for event log download and configuration |
| Self-Test | Automatic daily bump test verification |
| Compliance | ATEX II 2G Ex ib IIC T4 Gb, IECEx ib IIC T4 Gb, UL 913 Class I, Div 1, Groups A–D, T4, CSA C22.2 No. 152 |
| Brand | Honeywell |
|---|---|
| Origin | USA |
| Distributor Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PPT Series |
| Output Options | RS232 / RS485 Digital or 0–5 VDC Analog |
| Accuracy | ±0.05% FSO over –40 to +85 °C |
| EMC Protection | Enhanced EMI Shielding per EN 61326-1 |
| Certifications | CE Marked (EMC & LVD Directives) |
| Dual Outputs | Independent Pressure and Sensor Temperature Signals |
| Compliance | Meets EN 61000-6-2 (Immunity) and EN 61000-6-4 (Emission) |
| Brand | Honeywell |
|---|---|
| Origin | USA |
| Model | PPT-R |
| Certification | FM, CSA, CE |
| Operating Temperature Range | –40 °C to +85 °C |
| Accuracy | ±0.05% FS (Full Scale Output) |
| Output Options | 0–5 VDC analog output |
| Digital Interface | RS232 / RS485 compatible |
| Enclosure | Hermetically Sealed, Ruggedized Housing with Integrated Cable |
| Compliance | ATEX Zone 1/21, IECEx, UL 913 Class I Div 1, EN 60079-0/-11 |
| Brand | Honeywell |
|---|---|
| Origin | USA |
| Model | RAEAlert Series |
| Detection Principle | Catalytic Bead (Combustible) / Electrochemical (Toxic) |
| Sampling Method | Diffusion |
| Power Supply | 24 VDC (9–28 VDC for combustible |
| Max. Power Consumption | 170 mA @ 24 VDC (combustible), 80 mA @ 24 VDC (toxic) |
| Output Signals | 4–20 mA (field-adjustable), RS485 Modbus RTU (optional), HART 7.2 (optional), 3-channel passive relay (optional) |
| Relay Rating | 30 VDC / 5 A, SPDT, configurable NO/NC |
| Display | 128 × 96 dot-matrix LCD with icon-based UI, 1 status LED + 4 function LEDs |
| Enclosure Material | Aluminum / Stainless Steel |
| IP Rating | IP66 |
| Explosion Protection | Ex d IIC T6 Gb / Ex tD A21 IP66 T80°C (combustible) |
| Fire Certification | CCCF |
| Metrology Approval | CPA |
| Functional Safety | SIL2 per IEC 61508 |
| Operating Temperature | −40°C to +70°C |
| Operating Humidity | 0–95% RH (non-condensing) |
| Pressure Range | 86–106 kPa |
| Dimensions (H×W×D) | 182 × 195 × 107 mm |
| Weight | 1.5 kg (aluminum) / 3.5 kg (stainless steel) |
| Mounting | 2-inch pipe or wall-mount |
| Electrical Entry | 3/4" NPT male |
| Brand | Honeywell |
|---|---|
| Model | RAEGuard 3 |
| Origin | USA |
| Sensor Types | Catalytic Bead (LEL), Electrochemical (Toxic Gases & O₂), NDIR (O₂) |
| Enclosure Rating | IP66/IP67 |
| Safety Certification | TÜV SIL 2 |
| Output | 4–20 mA (HART® optional), RS485 Modbus RTU, Bluetooth® v5.0 |
| Display | Backlit graphical LCD with bar graph, numeric concentration, and icon-based status indicators |
| Operating Temperature | –40 °C to +70 °C |
| Power Supply | 12–30 VDC |
| Compliance | IEC 61508, IEC 61511, ATEX, IECEx, UL/cUL Class I Div 1, FM, CSA |
| Brand | Honeywell |
|---|---|
| Origin | USA |
| Model | RAEGUARD |
| Detection Gases | H₂ (0–100% LEL), CO (50–1000 ppm) |
| Protection Rating | IP65 |
| Operating Temperature | −30°C to +60°C (H₂ units), −20°C to +50°C (CO unit) |
| Communication | Modbus RTU over RS-485, Bluetooth 5.0 (BLE) |
| Power Supply | 24 VDC (12–27 VDC) |
| Certifications | EN/IEC 61010-1, UL/CSA 61010-1, EN 50270, UL 2075, RED, FCC |
| Expected Service Life | 10 years (sensor life: 5 years) |
| Relay Outputs | 2 × 15 A @ 24 VDC (host), 1 × 1 A @ 24 VDC (host) |
| Enclosure Material | Carbon-black polycarbonate |
| Dimensions (Host) | 110 mm × 110 mm × 50 mm |
| Weight (Host) | 350 g |
| Wireless Range | ≤10 m (line-of-sight) |
| Brand | Honeywell |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | RAEGuard Lite Series Point-Type |
| Pricing | Upon Request |
| Detection Principle | Catalytic Combustion (for combustible gases) / Electrochemical (for toxic gases & O₂) |
| Sampling Method | Diffusion |
| Power Supply | 24 VDC (16–32 VDC operating range) |
| Typical Power Consumption | <1 W (electrochemical), 2 W typical / 5 W max (catalytic) |
| Output Signals | Configurable 4–20 mA (sourcing), optional HART® 7.2 protocol |
| Digital Interface | RS485 Modbus RTU |
| Relay Outputs | Optional 3 × 30 VDC / 5 A |
| Enclosure Rating | IP66 |
| Explosion Protection | Ex db IIC T6 Gb / Ex tb IIIC T80°C (LEL & EC variants) |
| Operating Temperature | −40°C to +70°C |
| Operating Humidity | LEL: 0–95% RH (non-condensing) |
| Toxic/O₂ | 15–95% RH (non-condensing) |
| Pressure Range | 90–110 kPa |
| Dimensions (H×W×D) | 176 × 157 × 118.5 mm |
| Housing Material | Aluminum alloy |
| Sensor Housing Material | 316 stainless steel |
| Weight | ~2.3 kg |
| Optional Features | Built-in surge protection module, Bluetooth® wireless configuration, non-intrusive magnetic wand operation |
| Brand | Honeywell |
|---|---|
| Origin | USA |
| Model | Searchline Excel |
| Certification | ATEX, UL, CSA, IEC 61508 SIL 2 |
| Output | MODBUS RTU (RS-485), 4–20 mA analog |
| Detection Principle | Non-dispersive infrared (NDIR) absorption spectroscopy |
| Operating Range | Up to 120 m path length |
| Environmental Rating | IP66/IP67, -40 °C to +60 °C |
| Compliance | EN 61000-6-2/-6-4, IEC 61326-1, PED 2014/68/EU |
| Sensor Compatibility | Fully compatible with Honeywell XNX universal transmitter platform |
| Mounting | Three-point alignment base with mechanical lock |
| Brand | Honeywell |
|---|---|
| Origin | USA |
| Model | Searchpoint Optima Plus |
| Detection Principle | Non-Dispersive Infrared (NDIR) |
| Certifications | ATEX, IECEx, UL, CSA, FM, SIL 2 (per IEC 61508) |
| Operating Environment | Hazardous Areas (Zone 1/21, Class I Div 1/2) |
| Gas Coverage | Hydrocarbons (e.g., methane, propane, butane, pentane, hexane, toluene, xylene, MEK, acetone), LPG, LNG, solvent vapors |
| Output Signal | 4–20 mA HART, Modbus RTU |
| Enclosure Rating | IP66/IP67 |
| Power Supply | 12–30 VDC |
| Response Time (T90) | <15 s typical for methane |
| Zero Drift | <2% LEL/year (typical, field-validated) |
| Sensor Lifetime | ≥10 years (NDIR optical path, no consumables) |
| Maintenance Interval | Recommended annual verification |
| Brand | Honeywell |
|---|---|
| Origin | USA |
| Model | SearchSonic Imager |
| Type | Handheld Acoustic Imaging Camera |
| Detection Principle | Ultrasonic Time-of-Flight Beamforming Array |
| Frequency Range | 20–100 kHz (adjustable bandwidth) |
| Operating Distance | 1 m to 50 m (dependent on leak size, pressure differential, and background noise) |
| Weight | <1.2 kg |
| Battery Life | ≥4 hours continuous operation |
| Display | 5.5″ OLED touchscreen (1920×1080) |
| Data Output | MP4 video + WAV audio + CSV metadata |
| Compliance | CE, UKCA, ATEX Zone 2/22, IECEx Zone 2/22, IP54 |
| Brand | Honeywell |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Searchzone Sonik |
| Pricing | Upon Request |
| Brand | Honeywell |
|---|---|
| Origin | USA |
| Model | Sensepoint XCD |
| Sensor Compatibility | Catalytic Bead (LEL), Electrochemical (Toxic Gases), NDIR (CO₂, CH₄, etc.) |
| Enclosure Material | LM25 Aluminum Alloy & 316 Stainless Steel |
| Certifications | IECEx, ATEX, UL, CSA, KTL, GB-Ex, CCCF |
| Output Signals | 4–20 mA (2-wire/3-wire sink/source), 3 Programmable Relays, Modbus RTU (RS-485) |
| Display | Backlit LCD with Tri-color Status Indicator (Green/Amber/Red) |
| Diagnostic Features | SureCell™ Sensor Recognition, Reflex™ Self-Diagnostics, Auto-Calibration Support |
| Environmental Rating | IP66, NEMA 4X, -40°C to +70°C Operating Range |
| Mounting | Integrated Wall-Mount Brackets, Plug-in Sensor Cartridge Design |
| Compliance | Designed for use in Class I Div 1/Zone 1 hazardous areas per IEC 60079-29-1, EN 45544-1, ISO 10156, and aligned with FDA 21 CFR Part 11 data integrity principles for alarm logging |
| Brand | Honeywell |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | XNX |
| Pricing | Upon Request |
