Jiayuan
Filter
Showing 31–60 of 78 results
| Brand | Jiayuan |
|---|---|
| Origin | Beijing, China |
| Model | JY-335 |
| Maximum Sample Thickness Range | 0–100 µm |
| Sectioning Increment | 1 µm (0–10 µm), 2 µm (10–20 µm), 5 µm (20–50 µm), 10 µm (50–100 µm) |
| Re-Trim Range | 0–500 µm |
| Max Horizontal Specimen Travel | 28 mm |
| Max Vertical Specimen Travel | 60 mm |
| Automatic Specimen Advance & Retraction | 12 µm |
| Minimum Sectioning Resolution | 1 µm |
| Sectioning Accuracy | ±1% |
| Max Section Area | 50 × 50 mm |
| Dimensions | 520 × 450 × 300 mm |
| Power Supply | AC 220 V / 110 V, 50 / 60 Hz |
| Brand | Jiayuan |
|---|---|
| Origin | Beijing, China |
| Model | JY-335III |
| Max Sample Size | 50×45 mm |
| Section Thickness Range | 0–100 µm |
| Section Increment | 1 µm (0–10 µm), 2 µm (10–20 µm), 5 µm (20–50 µm), 10 µm (50–100 µm) |
| Trimming Range | 0–500 µm |
| Horizontal Sample Travel | 28 mm |
| Vertical Sample Travel | 60 mm |
| Automatic Feed & Retraction | 12 µm |
| Feed Resolution | 1 µm |
| Sectioning Accuracy | ±5% |
| Cryostage Max Area | 45×40 mm |
| Blade Angle | 45° |
| Cooling Time | 2–7 min to Operating Temp |
| Dimensions | 520×450×300 mm |
| Brand | Jiayuan |
|---|---|
| Origin | Beijing, China |
| Model | JY88-II |
| Ultrasonic Frequency | 20–25 kHz (auto-frequency tracking) |
| Output Power | 250 W |
| Duty Cycle | 1–99% |
| Pulse Mode | Adjustable On/Off ratio (10–90% for both ultrasonic and interval time) |
| Total Operating Time | 1–99 min |
| Standard Probe Diameter | Φ6 mm |
| Optional Probes | Φ2, Φ3, Φ2–Φ15, Φ18–Φ25 mm |
| Sample Volume Capacity | 0.2–200 mL |
| Input Voltage | 220 V / 110 V, 50 Hz / 60 Hz |
| Instrument Type | Ultrasonic Cell Disruptor |
| Brand | Jiayuan |
|---|---|
| Origin | Beijing, China |
| Model | JY88-IIN |
| Ultrasonic Frequency | 20–25 kHz (auto-frequency tracking) |
| Output Power | 250 W (touch-key continuous adjustment) |
| Pulse Mode | Adjustable on-time (0.1–99.9 s) and off-time (0.1–99.9 s) |
| Total Operating Time | 1–99 min |
| Duty Cycle | 1–99% |
| Standard Probe | Φ6 mm titanium alloy horn |
| Optional Probes | Φ2, Φ3, Φ2–Φ15, Φ18–Φ25 mm |
| Sample Volume Range | 0.2–200 mL |
| Power Supply | 220/110 V AC, 50/60 Hz |
| Brand | Jiayuan |
|---|---|
| Origin | Beijing, China |
| Model | JY92-II |
| Ultrasonic Frequency | 20–25 kHz with automatic frequency tracking |
| Output Power | 650 W |
| Pulse Mode | Adjustable on-time (1–99 s) and off-time (1–99 s) |
| Cycle Count | 1–99 cycles |
| Standard Probe Diameter | Φ6 mm |
| Optional Probe Diameters | Φ2, Φ3, Φ8, Φ10, Φ15 mm |
| Sample Volume Range | 0.2–500 mL |
| Duty Cycle | 1–99% |
| Input Voltage | 220 V / 110 V, 50 Hz / 60 Hz |
| Brand | Jiayuan |
|---|---|
| Origin | Beijing, China |
| Model | JY92-IID |
| Ultrasonic Frequency | 20–25 kHz (auto-frequency tracking) |
| Output Power | 900 W |
| Pulse Mode | Adjustable On/Off duration (0.1–99 s) |
| Total Processing Time | 0.1–99 min |
| Temperature Monitoring Range | 0–99 °C |
| Standard Probe Diameter | Φ6 mm |
| Optional Probes | Φ2, Φ3, Φ8, Φ10, Φ15 mm |
| Sample Volume Capacity | 0.2–600 mL |
| Duty Cycle | 0.1–99.9% |
| Input Voltage | 220 V / 110 V, 50 Hz / 60 Hz |
| Brand | Jiayuan |
|---|---|
| Origin | Beijing, China |
| Model | JY92-IIDN |
| Ultrasonic Frequency | 20–25 kHz (auto-frequency tracking) |
| Output Power | 900 W (touch-key continuous adjustment) |
| Pulse Mode | On-time 0.1–99.9 s / Off-time 0.1–99.9 s / Total Duration 0.1–99 min |
| Duty Cycle | 0.1–99.9% |
| Temperature Monitoring Range | 0–100 °C |
| Standard Probe Diameter | Φ6 mm |
| Optional Probes | Φ2, Φ3, Φ8, Φ10, Φ15 mm |
| Sample Volume Capacity | 0.2–600 mL |
| Input Voltage | 220/110 V, 50/60 Hz |
| Brand | Jiayuan |
|---|---|
| Origin | Beijing, China |
| Model | JY92-IIN |
| Ultrasonic Frequency | 20–25 kHz (auto-frequency tracking) |
| Output Power | 650 W (touch-key continuous adjustment) |
| Pulse Mode | On-time 0.1–99.9 s, Off-time 0.1–99.9 s |
| Total Operating Time | 0.1–99 min |
| Temperature Monitoring Range | 0–100 °C |
| Standard Probe Diameter | Φ6 mm |
| Optional Probes | Φ2, Φ3, Φ8, Φ10, Φ15 mm |
| Sample Volume Capacity | 0.2–500 mL |
| Duty Cycle | 1–99% |
| Power Supply | 220/110 V, 50/60 Hz |
| Brand | Jiayuan |
|---|---|
| Origin | Beijing, China |
| Model | JY96-II |
| Ultrasonic Frequency | 20–25 kHz (auto-frequency tracking) |
| Output Power | 150 W |
| Pulse Duty Cycle | 10–90% (adjustable) |
| Interval Duty Cycle | 10–90% (adjustable) |
| Total Operation Time | 1–99 min |
| Standard Probe Diameter | Φ6 mm |
| Optional Probe Diameters | Φ2, Φ3, Φ2–Φ15, Φ18–Φ25 mm |
| Sample Volume Range | 0.2–100 mL |
| Duty Ratio | 1–99% |
| Power Supply | 220/110 V, 50/60 Hz |
| Brand | Jiayuan |
|---|---|
| Origin | Beijing, China |
| Model | JY96-IIN |
| Ultrasonic Frequency | 20–25 kHz with automatic frequency tracking |
| Output Power | 150 W (touch-key adjustable, continuous) |
| Pulse Mode | Duty Cycle 0.1–99.9% |
| Sonication Time | 0.1–99.9 s |
| Interval Time | 0.1–99.9 s |
| Total Operating Time | 0.1–99 min |
| Standard Probe Diameter | Φ6 mm |
| Optional Probes | Φ2, Φ3, Φ2–Φ15, Φ18–Φ25 mm |
| Sample Volume Capacity | 0.2–100 mL |
| Input Voltage | 220/110 V, 50/60 Hz |
| Brand | Jiayuan |
|---|---|
| Origin | Beijing, China |
| Model | JY98-III |
| Ultrasonic Frequency | 20–25 kHz with Automatic Frequency Tracking |
| Output Power | 1200 W |
| Pulse Mode | Adjustable On-Time (1–99 s) and Off-Time (1–99 s) |
| Cycle Count | 1–99 cycles |
| Standard Probe Diameter | Φ20 mm |
| Optional Probe Diameters | Φ15, Φ22, Φ25 mm |
| Sample Volume Capacity | 50–1000 mL |
| Duty Cycle | 1–99% |
| Input Voltage | 220 V / 110 V, 50 Hz / 60 Hz |
| Brand | Jiayuan |
|---|---|
| Origin | Beijing, China |
| Model | JY98-IIID |
| Ultrasonic Frequency | 20–25 kHz with automatic frequency tracking |
| Output Power | 1200 W |
| Pulse Mode | Adjustable on-time (0.1–99 s) and off-time (0.1–99 s) |
| Total Operating Time | 0.1–99 min |
| Temperature Monitoring Range | 0–99 °C |
| Standard Probe Diameter | Φ20 mm |
| Optional Probe Diameters | Φ15, Φ22, Φ25 mm |
| Sample Volume Capacity | 50–1000 mL |
| Duty Cycle | 0.1–99.9% |
| Power Supply | 220 V / 110 V, 50 Hz / 60 Hz |
| Brand | Jiayuan |
|---|---|
| Origin | Beijing, China |
| Model | JY98-IIIDN |
| Ultrasonic Frequency | 20–25 kHz (auto-frequency tracking) |
| Output Power | 1200 W (touch-key continuous adjustment) |
| Sonication Time Range | 0.1–99 s |
| Interval Time Range | 0.1–99 s |
| Total Working Time | 0.1–99 min |
| Temperature Monitoring Range | 0–100 °C |
| Standard Probe Diameter | Φ20 mm |
| Optional Probe Diameters | Φ15, Φ22, Φ25 mm |
| Sample Volume Capacity | 50–1000 mL |
| Duty Cycle | 0.1–99.9% |
| Input Voltage | 220/110 V, 50/60 Hz |
| Brand | Jiayuan |
|---|---|
| Origin | Beijing, China |
| Model | JY99-IID |
| Ultrasonic Frequency | 20–25 kHz with automatic frequency tracking |
| Output Power | 1800 W |
| Pulse Mode | On-time 0.1–99 s, Off-time 0.1–99 s |
| Total Operating Time | 0.1–99 min |
| Temperature Monitoring Range | 0–99 °C |
| Standard Probe Diameter | Φ25 mm |
| Optional Probe Diameters | Φ15, Φ22, Φ25, Φ28 mm |
| Sample Volume Capacity | 50–1200 mL |
| Duty Cycle | 0.1–99.9% |
| Power Supply | 220/110 V, 50/60 Hz |
| Brand | Jiayuan |
|---|---|
| Origin | Beijing, China |
| Model | JY99-IIDN |
| Ultrasonic Frequency | 20–25 kHz (auto-frequency tracking) |
| Output Power | 1800 W (touch-key continuous adjustment) |
| Pulse Mode | On-time 0.1–99 s / Off-time 0.1–99 s |
| Total Operating Time | 0.1–99 min |
| Temperature Monitoring Range | 0–100 °C |
| Standard Probe Diameter | Φ25 mm |
| Optional Probes | Φ15, Φ22, Φ25, Φ28 mm |
| Sample Volume Capacity | 50–1200 mL |
| Duty Cycle | 0.1–99.9% |
| Input Voltage | 220/110 V AC, 50/60 Hz |
| Brand | Jiayuan |
|---|---|
| Model | K30 |
| Temperature Range | Ambient +5°C to 100°C |
| Heating Time | ≤15 min (20°C → 100°C) |
| Temperature Accuracy | ±0.5°C |
| Display Resolution | 0.1°C |
| Block Uniformity | ±0.5°C |
| Max Power | 150 W |
| Max Set Temperature | 105°C |
| Timer Range | 1–9999 min |
| Dimensions (W×D×H) | 176 × 156 × 121 mm |
| Net Weight | 1.5 kg |
| Origin | Beijing, China |
| Module Type | Interchangeable Round-Well Aluminum Blocks |
| Brand | Jiayuan |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | M-1 |
| Dimensions | 290 × 180 × 160 mm (L × W × H) |
| Cage Body Material | Polypropylene (PP) |
| Lid | 304 Stainless Steel Wire Mesh |
| Water Bottle Capacity | 250 mL |
| Compliance | Designed for IACUC-compliant rodent housing per NIH Guide and AAALAC International standards |
| Brand | Jiayuan |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic Laboratory Animal Housing Equipment |
| Model | M-1/70 |
| Pricing | Upon Request |
| Brand | Jiayuan |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic Laboratory Animal Housing |
| Model | M-5 |
| Dimensions (L×W×H) | 475 × 350 × 200 mm |
| Cage Components | One PP (polypropylene) housing box, one 304 stainless steel wire lid, one 500 mL autoclavable water bottle |
| Optional Configuration | M-5 (Bottomless) variant includes removable stainless steel waste tray |
| Brand | JIAYUAN |
|---|---|
| Origin | Beijing, China |
| Model | MB100-2A |
| Timer Range | 0–99 h 59 min |
| Oscillation Speed | 300–1200 rpm |
| Orbital Diameter | 3 mm |
| Temperature Range | Ambient +5°C to 70°C |
| Capacity | 2 standard microplates (e.g., 96-well, 384-well, deep-well, cell culture plates) |
| Temperature Uniformity | ≤ ±0.5°C |
| Temperature Stability | ≤ ±0.2°C |
| Heating Accuracy | < ±0.3°C at 37°C |
| Ramp Time | < 25 min (20°C → 70°C) |
| Power Consumption | 150 W |
| Dimensions | 284 × 264 × 157 mm (W × D × H) |
| Brand | Jiayuan |
|---|---|
| Origin | Beijing, China |
| Model | MB100-4A |
| Timer Range | 0–9999 min |
| Oscillation Frequency | 100–1200 rpm |
| Oscillation Amplitude | 2 mm (horizontal orbital) |
| Temperature Range | Ambient +5°C to 70°C |
| Number of Shaking Platforms | 4 |
| Temperature Uniformity | ≤ ±0.5°C |
| Temperature Stability | ≤ ±0.2°C |
| Heating Accuracy | < ±0.3°C at 37°C |
| Ramp Time | < 25 min (20°C → 70°C) |
| Max Power Consumption | 250 W |
| Dimensions (W×D×H) | 345 × 310 × 178 mm |
| Brand | Jiayuan |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | MC-15 |
| Price Range | USD 1–699 |
| Centrifugation Class | Biomolecular Separation |
| Maximum Capacity | 12 × 2 mL tubes |
| Maximum Speed | 15,000 rpm |
| Dimensions | 240 mm × 220 mm × 145 mm |
| Weight (incl. rotor) | 4.7 kg |
| Acceleration Time to Max Speed | <13 s |
| Deceleration Time from Max Speed | <12 s |
| Rotor Material | Anodized Aluminum Alloy |
| Display | Backlit LCD |
| Power Supply | 110–120 V / 220–230 V, 50–60 Hz |
| Power Consumption | 105 W |
| Safety Features | Lid Interlock, Overspeed Protection, Overtemperature Monitoring, Real-time Diagnostics |
| Special Functions | Short-Cycle “Pulse” Mode, rpm/RCF Conversion, Audible End-of-Run Alert, Temperature-Stable Airflow Management |
| Brand | Jiayuan |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | MC-16 |
| Price Range | USD 1,400–4,200 |
| Centrifugation Class | Biomacromolecules |
| Max Capacity | 24 × 2 mL tubes |
| Max Speed | 16,000 rpm |
| Dimensions (W×D×H) | 360 × 635 × 280 mm |
| Max RCF | 24,900 × g |
| Temperature Range | −20 °C to +40 °C (0.5 °C increment) |
| Noise Level | ≤52 dB(A) |
| Acceleration/Deceleration Time | 20 s |
| Display | 4.3″ TFT color touchscreen |
| Control System | EssenFuge™ microprocessor-based interface |
| Rotor Recognition | Automatic |
| Safety Features | Dual overspeed detection, real-time imbalance monitoring, motor/compressor overtemperature protection, auto-shutdown with error code display |
| Chamber Material | Teflon-coated stainless steel |
| Insulation | In-situ foamed polyurethane |
| Door Lock | Motorized suction-type electronic latch |
| Pre-cooling | Yes |
| Defrost Function | Yes |
| Flash Spin Mode | Yes |
| Program Storage | 10 user-defined protocols |
| Quick-Start Keys | 5 |
| Ramp Rate Options | 9 selectable profiles |
| Compliance | Designed for GLP-compliant laboratories |
| Brand | Jiayuan |
|---|---|
| Origin | Beijing, China |
| Model | MD-12 |
| Heating Method | Water Bath |
| Temperature Range | Ambient +5°C to 99°C |
| Temperature Stability | ≤±1°C |
| Sample Capacity | 12 positions |
| Tube Diameter Compatibility | Φ10–29 mm |
| Gas Flow Rate | 0–15 L/min |
| Max. Gas Pressure | 0.2 MPa |
| Heating Power | 1000 W |
| Dimensions (W×D×H) | 390×300×850 mm |
| Weight | 9.5 kg |
| Display Resolution | ±0.1°C |
| Temperature Uniformity @60°C | ≤±1°C |
| Ramp Time (40→99°C) | ≤30 min |
| Needle Stroke | 200 mm |
| Needle Length | 100 mm |
| Gas Connector OD | φ7 mm |
| Fuse | 250 V, 8 A, Ф5×20 mm |
| Construction Materials | Stainless steel, food-grade silicone tubing, solvent-resistant components |
| Brand | Jiayuan |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | MD-24 |
| Price | USD 1,380 (FOB) |
| Heating Method | Water Bath |
| Temperature Range | Ambient to 99 °C |
| Temperature Uniformity | ±1 °C |
| Tube Diameter Compatibility | 10–29 mm |
| Gas Flow Rate | 0–15 L/min |
| Sample Capacity | 24 positions |
| Heating Power | 1 kW |
| Brand | Jiayuan |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | MD200-1 |
| Heating Method | Dry-Block Heating |
| Temperature Range | Ambient +5°C to 150°C |
| Temperature Uniformity | ±1°C (at 40–100°C), ±1.5°C (at 100–150°C) |
| Temperature Stability | ±1°C (at 100°C) |
| Sample Capacity | 12 positions |
| Tube Compatibility | 0.5–15 mL |
| Gas Flow Rate | 0–10 L/min |
| Maximum Gas Pressure | ≤0.1 MPa |
| Heating Power | 400 W |
| Block Module | Single interchangeable block (compatible with KD200-series modules, e.g., BD04 or BD05) |
| Display | LED, 0.1°C resolution |
| Timer Range | 0–99 h 59 min |
| Dimensions (W×D×H) | 280 × 240 × 500 mm |
| Safety Features | Over-temperature protection, real-time fault detection and audible/visual alarm |
| Optional Integration | Ventilation hood compatible |
| Brand | Jiayuan |
|---|---|
| Origin | Beijing, China |
| Model | MD200-1A |
| Heating Method | Dry-block heating |
| Temperature Range | Ambient +5°C to 150°C |
| Temperature Uniformity | ±0.5°C (at 40–100°C) |
| Tube Capacity | 0.5 mL to 15 mL |
| Gas Flow Rate | 0–10 L/min |
| Sample Positions | 12 |
| Heating Power | 200 W |
| Display | LED, 0.1°C resolution |
| Timer Range | 0–99 h 59 min |
| Max Operating Pressure | ≤0.1 MPa |
| Dimensions | 280 × 240 × 500 mm |
| Safety | Over-temperature protection, real-time fault detection & audible alarm |
| Modular Compatibility | BK19 (96 × 0.2 mL tubes), BK20 (8-well microplate) |
| Brand | Jiayuan |
|---|---|
| Origin | Beijing, China |
| Model | MiniP-2500 |
| Maximum Capacity | 2 × 96-well PCR plates |
| Maximum Speed | 2500 rpm |
| Relative Centrifugal Force (RCF) | 500 × g |
| Dimensions (W×D×H) | 23 × 20 × 19.3 cm |
| Weight | 3 kg |
| Power Supply | DC 24 V |
| Motor Type | Brushless DC motor |
| Acceleration Time to Max Speed | < 3 s |
| Deceleration Time from Max Speed to Stop | ≤ 10 s |
| Operating Environment | Compatible with cold room use (4–25 °C) |
| Lid Opening Angle | 95° vertical hinge |
| Brand | JIAYUAN |
|---|---|
| Origin | Beijing, China |
| Model | MIX-3000 |
| Speed Range | 300–3000 rpm (10-rpm increments) |
| Vortex Mode Speed | 3500 rpm |
| Mixing Time | 1 s – 99 h 59 min (continuous operation) |
| Orbit Diameter | 1.5 mm (standard), 3 mm (optional amplitude) |
| Display | Digital LED |
| Noise Level | <52 dB(A) |
| Dimensions (W×D×H) | 270 × 196 × 170 mm |
| Weight | 4.5 kg |
| Power Supply | AC 100–230 V, 50–60 Hz |
| Power Consumption | 45 W |
| Housing Material | High-impact polymer housing |
| Compliance | CE-marked for laboratory use |
| Brand | Jiayuan |
|---|---|
| Model | MK-10 Heated |
| Origin | Beijing, China |
| Heating Range | Room Temperature +5°C to 100°C |
| Temperature Stability @100°C | ≤±0.5°C |
| Block Uniformity | ≤±0.3°C |
| Display Resolution | 0.1°C |
| Ramp Time | ≤15 min (20°C → 100°C) |
| Max Timer Setting | 99 h 59 min |
| Power Consumption | 150 W |
| Net Weight | 2.2 kg |
| Dimensions (W×D×H) | 270 × 190 × 170 mm |
| Interchangeable Block Options | A–N (including 0.2 mL PCR plates, 0.5/1.5/2.0 mL tubes, 5/15/50 mL tubes, square wells, and custom configurations) |