Metash Instruments
Filter
Showing 1–30 of 61 results
| Brand | Metash Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Flame and Graphite Furnace AAS |
| Monochromator | Plane Grating (1800 lines/mm) |
| Optical System | Double-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Deuterium Lamp |
| Spectral Resolution | <0.03 nm |
| Sensitivity | Cu 1 ppm → Absorbance >0.01 A |
| Precision (RSD) | ≤0.05% (Flame mode, optimized conditions) |
| Detection Limits | Cu ≤ 0.006 µg/mL (Flame), Cd ≤ 1.0 × 10⁻¹² g (Graphite Furnace) |
| Brand | Metash Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Flame AAS |
| Model | AA-3600F |
| Monochromator | Plane Grating (1800 grooves/mm) |
| Optical System | Single-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | D₂ Lamp + Self-Reversal Method |
| Spectral Bandwidth | 0.2 / 0.4 / 1.0 / 2.0 nm (auto-switchable) |
| Wavelength Range | 190–900 nm |
| Wavelength Accuracy | ±0.1 nm |
| Wavelength Repeatability | 0.1 nm |
| Resolution | 0.1 nm |
| Characteristic Concentration (Cu) | 0.02 µg/mL per 1% absorption |
| Detection Limit (Cu) | 0.002 µg/mL |
| Baseline Drift | ≤0.004 A/30 min |
| Background Correction Capability | >30× at 1 A |
| RSD (Precision) | ≤1.0% |
| Atomizer | Air-Acetylene Flame |
| Lamp Turret | 6-position Auto-rotating Holder |
| Beam Splitting | Semi-reflective/Semi-transmissive Device for D₂ Background Balance |
| Brand | Metash Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer | Yes |
| Instrument Type | Graphite Furnace AAS |
| Monochromator | Plane Grating |
| Optical System | Single-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | D₂ Lamp + Self-Reversal Method |
| Spectral Resolution | 0.1 nm |
| Characteristic Mass (Cd) | 0.4 × 10⁻¹² g |
| Detection Limit (Cd) | 0.5 × 10⁻¹² g |
| Precision (RSD) | ≤3% |
| Wavelength Range | 190–900 nm |
| Grating Grooves | 1800 lines/mm |
| Spectral Bandwidths | 0.2 / 0.4 / 1.0 / 2.0 nm (auto-switchable) |
| Wavelength Accuracy | ±0.1 nm |
| Wavelength Repeatability | 0.1 nm |
| Baseline Drift | 0.004 A / 30 min |
| Background Correction Capacity | >30× at 1 A |
| Brand | Metash Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Flame and Graphite Furnace AAS |
| Monochromator | Plane Grating (1800 grooves/mm) |
| Optical System | Single-beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Deuterium Lamp + Self-Absorption |
| Spectral Resolution | 0.1 nm |
| Sensitivity | 0.02 µg/mL/1% (Cu), 0.4 × 10⁻¹² g (Cd) |
| Detection Limit | 0.002 µg/mL (Cu), 0.5 × 10⁻¹² g (Cd) |
| Precision (RSD) | ≤1.0% (Flame), ≤3.0% (Graphite Furnace) |
| Wavelength Range | 190–900 nm |
| Wavelength Accuracy | ±0.1 nm |
| Wavelength Repeatability | 0.1 nm |
| Baseline Drift | 0.004 A / 30 min |
| Spectral Bandwidths | 0.2 / 0.4 / 1.0 / 2.0 nm (auto-switchable) |
| Brand | Metash Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Flame AAS |
| Monochromator | Plane Grating |
| Optical System | Single-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | D₂ Lamp + Self-Absorption Method |
| Spectral Resolution | 0.1 nm |
| Sensitivity (Cu) | 0.02 µg/mL per 1% absorption |
| Detection Limit (Cu) | 0.002 µg/mL |
| Precision (RSD) | ≤1.0% |
| Wavelength Range | 190–900 nm |
| Grating Grooves | 1800 lines/mm |
| Spectral Bandwidths | 0.2 / 0.4 / 1.0 / 2.0 nm (auto-switchable) |
| Wavelength Accuracy | ±0.1 nm |
| Wavelength Repeatability | 0.1 nm |
| Baseline Drift | 0.003 A/30 min |
| Background Correction Capacity (D₂) | >30× at 1 A |
| Brand | Metash Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | B-500 |
| Spectral Bandwidth | 15,000 ng/µL (dsDNA) |
| Wavelength Accuracy | ±1 nm |
| Wavelength Range | 200–850 nm |
| Cuvette-Based Detection Limit | 2 ng/µL (dsDNA) |
| Brand | Metash Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | B-600 |
| Detection Time | 3 s (cuvette mode), 5 s (ultra-micro mode) |
| Wavelength Accuracy | ±1 nm |
| Wavelength Range | 190–1100 nm |
| Wavelength Resolution | 0.3 nm |
| Absorbance Range | 0–300 Abs (10 nm pathlength equivalent) |
| Detection Limit | 2 ng/µL (dsDNA) |
| Upper Detection Limit | 15,000 ng/µL (dsDNA) |
| Sample Volume | 1–2 µL |
| Pathlength Range | 0.01–1.2 mm (auto-adjusting) |
| Detector | 2048-pixel CCD array |
| Light Source | Xenon flash lamp |
| Dimensions | 220 × 280 × 220 mm |
| Weight | 3 kg |
| Power Supply | 100–240 V, 50–60 Hz |
| Power Consumption | 80–100 W |
| Compatible Samples | dsDNA, ssDNA, RNA, proteins (BSA), cell cultures (OD₆₀₀) |
| Brand | Metash Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | High-Speed (10,000–30,000 rpm) |
| Max. Speed | 18,000 rpm |
| Max. RCF | 30,427 × g |
| Max. Capacity | 18 × 5 mL |
| Dimensions (L×W×H) | 392 × 290 × 300 mm |
| Net Weight | 22 kg |
| Drive Motor | Brushless AC Frequency-Controlled Motor |
| Acceleration Steps | 9 |
| Deceleration Steps | 10 |
| Timer Range | 1 min – 99 min (continuous operation supported) |
| Cooling | Air-Cooled (R-134a refrigerant-free |
| Noise Level | ≤52 dB(A) |
| Display | Color LCD Screen |
| Power Supply | 220 V ±10%, 50 Hz ±1 Hz, 500 VA |
| Rotor Autoclavable | Yes (121°C, 20 min, steam sterilization compatible) |
| Safety Features | Dual interlock system (electronic feedback + mechanical latch), real-time imbalance detection, overspeed protection, overtemperature monitoring, self-diagnostic status reporting, free-deceleration mode |
| Brand | Metash Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | High-Speed (10,000–30,000 rpm) |
| Function | Refrigerated Centrifugation |
| Configuration | Fixed-Angle Rotor Centrifuge |
| Max. Capacity | 18 × 5 mL |
| Max. Speed | 18,000 rpm |
| Max. RCF | 30,427 × g |
| Dimensions | 595 × 290 × 300 mm |
| Cooling Range | −20 °C to +40 °C |
| Noise Level | ≤52 dB(A) |
| Refrigerant | R-134a |
| Motor | Brushless AC Frequency-Controlled Motor |
| Acceleration Steps | 9 |
| Deceleration Steps | 10 |
| Timer Range | 1 min – 99 min (continuous operation supported) |
| Display | Color LCD |
| Power Supply | 220 V ±10%, 50 Hz ±1 Hz, 500 VA |
| Net Weight | 38 kg |
| Rotor Sterilization | Autoclavable (121 °C, 20 min, saturated steam) |
| Brand | Metash Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | C5080R |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | High-Speed (10,000–30,000 rpm) |
| Function | Refrigerated Centrifuge |
| Configuration | Fixed-Angle Rotor Centrifuge |
| Max Capacity | 6 × 120 mL |
| Max Speed | 18,000 rpm |
| Max RCF | 28,978 × g |
| Dimensions | 730 × 380 × 370 mm |
| Noise Level | ≤58 dB(A) |
| Temperature Range | −20 °C to +40 °C |
| Refrigerant | R-134a |
| Motor | Brushless AC Frequency-Controlled Motor |
| Acceleration Steps | 9 |
| Deceleration Steps | 10 |
| Programmable Methods | 30 user-defined protocols |
| Display | Color LCD |
| Power Supply | 220 V ±10%, 50 Hz ±1 Hz, 1800 VA |
| Net Weight | 63 kg |
| Brand | Metash Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | High-Speed (10,000–30,000 rpm) |
| Function | Refrigerated Centrifuge |
| Configuration | Fixed-Angle Rotor System |
| Max Capacity | 6 × 250 mL |
| Max Speed | 18,000 rpm |
| Max RCF | 28,978 × g |
| Temperature Range | −20 °C to +40 °C |
| Noise Level | ≤58 dB(A) |
| Power Supply | 220 V ±10%, 50 Hz ±1 Hz, 1200 W |
| Display | 10-inch HD Color Touchscreen |
| Acceleration/Deceleration | 10-step programmable |
| Timer Range | 1 min – 99 min (continuous operation mode available) |
| Refrigerant | R-134a |
| Drive Motor | Brushless AC Frequency-Controlled Motor |
| Brand | Metash Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | C6080R |
| Instrument Type | Floor-standing centrifuge |
| Speed Range | 10,000–30,000 rpm (max. 18,000 rpm) |
| Function | Refrigerated centrifugation |
| Configuration | Horizontal rotor system |
| Max. Capacity | 4 × 250 mL |
| Max. RCF | 28,978 × g |
| Dimensions | 650 × 520 × 800 mm (L×W×H) |
| Noise Level | ≤58 dB(A) |
| Temperature Range | −20 °C to +40 °C |
| Refrigerant | R-134a |
| Motor | AC brushless frequency-converter motor |
| Acceleration Steps | 9 |
| Deceleration Steps | 10 |
| Programmable Methods | 30 user-defined protocols |
| Display | Color LCD |
| Power Supply | 220 V ±10%, 50 Hz ±1 Hz, 1800 VA |
| Net Weight | 100 kg |
| Brand | Metash Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | MWD-500 |
| Chamber Class | Industrial-Grade |
| Sample Capacity | 6/8/10 positions |
| Microwave Source | Single Magnetron |
| Max Temperature | 250 °C / 300 °C |
| Max Pressure | 6 MPa |
| Temperature Sensing | High-Accuracy Platinum Resistance (Pt100) |
| Pressure Sensing | Non-Contact Multi-Channel Optical Fiber Scanning System |
| Vessel Volume | 100 mL |
| Microwave Power Output | 0–1000 W |
| Control Interface | 7-inch Capacitive Touchscreen |
| Dimensions (W×D×H) | 490 × 560 × 533 mm |
| Vessel Construction | Inner Vessel — TFM (ASTM D4894-compliant fluoroelastomer) |
| Brand | Metash Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | MWD-520 |
| Price Range | USD 21,000 – 28,000 |
| Cavity Class | Industrial-Grade |
| Sample Capacity | 6/8/10 positions (selectable) |
| Microwave Source | Single Magnetron |
| Max Temperature | 250 °C |
| Max Pressure | 6 MPa |
| Microwave Power Output | 0–1000 W |
| Display | 7-inch capacitive touchscreen |
| Dimensions (W×D×H) | 490 × 560 × 533 mm |
| Inner Vessel Volume | 100 mL |
| Inner Vessel Material | Imported TFM (modified PTFE) |
| Outer Vessel Material | PEEK-glass fiber composite |
| Temperature Control | Non-contact mid-infrared full-vessel scanning (0.1 °C resolution) |
| Pressure Control | Multi-channel optical fiber pressure scanning |
| Cooling System | Turbulent airflow cooling (≤90 °C in ≤8 min) |
| Brand | Metash Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | MWD-630 |
| Price Range | USD 28,000 – 42,500 |
| Cavity Class | Industrial-Grade |
| Batch Capacity | 1–12 samples |
| Microwave Source | Single Magnetron |
| Max Temperature | 300 °C |
| Max Pressure | 15 MPa |
| Temperature Control | Non-contact mid-infrared scanning |
| Pressure Control | Multi-fiber optic non-contact scanning |
| Inner Vessel Volume | 100 mL |
| Vessel Material | TFM fluoropolymer inner vessel |
| Microwave Power Output | 0–1000 W continuous |
| Display | 7-inch capacitive touchscreen |
| Dimensions (W×D×H) | 490 × 560 × 630 mm |
| Brand | Metash Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | MWD-700 |
| Price Range | USD 2,800 – 7,000 (FOB) |
| Cavity Class | Industrial Grade |
| Max. Sample Capacity | 15 vessels |
| Microwave Source | Dual Magnetron |
| Max. Temperature | 250 °C |
| Max. Pressure | 6 MPa |
| Temperature Control | Non-contact mid-infrared scanning |
| Pressure Control | Multi-channel fiber-optic pressure sensing |
| Vessel Volume | 100 mL |
| Inner Vessel Material | TFM (perfluoroalkoxy alkane, imported) |
| Outer Vessel Material | PEEK-glass fiber composite |
| Microwave Power Output | 0–2000 W |
| Display | 8-inch external touch panel |
| Dimensions (W×D×H) | 640 × 630 × 590 mm |
| Safety Compliance | GB/T 26814–2011 (microwave leakage ≤5 mW/cm² at 5 cm), ISO/IEC 17025-aligned operational safeguards |
| Brand | Metash Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | MWD-750 |
| Price Range | USD 28,000–42,000 (FOB Shanghai) |
| Cavity Class | Industrial-Grade |
| Max. Sample Capacity | 18 vessels |
| Microwave Source | Dual Magnetron |
| Max. Temperature | 250 °C |
| Max. Pressure | 6 MPa |
| Temperature Control | Non-contact mid-infrared scanning |
| Pressure Control | Multi-channel optical fiber pressure sensing |
| Vessel Volume | 100 mL |
| Inner Vessel Material | TFM (PFA-modified PTFE) |
| Outer Vessel Material | PEEK-glass fiber composite |
| Microwave Power Output | 0–3000 W |
| Display | 8-inch external touchscreen |
| Dimensions (W×D×H) | 640 × 630 × 590 mm |
| Safety Compliance | GB/T 26814–2011 (microwave leakage ≤5 mW/cm² at 5 cm) |
| Brand | Metash Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | MWD-800 |
| Price Range | USD 56,000–70,000 (FOB Shanghai) |
| Cavity Class | Industrial Grade |
| Sample Capacity | 40 vessels |
| Microwave Source | Dual Magnetron |
| Max Temperature | 250 °C |
| Max Pressure | 6 MPa |
| Temperature Control | Non-contact mid-infrared scanning |
| Pressure Control | Multi-fiber optic non-contact scanning |
| Vessel Volume | 50 mL |
| Vessel Material | TFM-lined inner vessels |
| Microwave Power Output | 0–3000 W (continuously adjustable) |
| Display | External 8-inch capacitive touchscreen controller |
| Dimensions (W×D×H) | 640 × 630 × 590 mm |
| Cooling System | Multi-channel turbulent forced-air cooling |
| Cavity Material | 316L stainless steel with multi-layer PFA coating |
| Turntable | 360° unidirectional rotation |
| Brand | Metash Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer | Yes |
| Type | Domestic |
| Model | Q-5 |
| Optical Design | Dual-beam |
| Detector | Photomultiplier Tube (PMT) |
| Wavelength Range | 190–900 nm |
| Wavelength Scanning | Motorized Auto-Scan |
| Spectral Bandwidth | 1.8 nm |
| Wavelength Accuracy | ±0.3 nm |
| Wavelength Repeatability | ≤0.1 nm |
| Stray Light | ≤0.01% T |
| Photometric Accuracy | ±0.3% T |
| Photometric Repeatability | ≤0.1% T |
| Baseline Drift | ≤0.0003 Abs/h |
| Brand | Metash Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | Q-5S |
| Optical System | Dual-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Wavelength Range | 190–900 nm |
| Wavelength Accuracy | ±0.3 nm |
| Wavelength Repeatability | ≤0.1 nm |
| Spectral Bandwidth | 0.1–5.0 nm (continuously adjustable in 0.1 nm increments) |
| Stray Light | ≤0.01% T |
| Photometric Accuracy | ±0.3% T |
| Photometric Repeatability | ≤0.1% T |
| Baseline Drift | ≤0.0003 Abs/h |
| Brand | Metash Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | Q-6 |
| Optical System | Dual-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Wavelength Range | 190–900 nm |
| Wavelength Accuracy | ±0.3 nm |
| Wavelength Repeatability | ≤0.1 nm |
| Spectral Bandwidth | 0.1–5.0 nm (continuously adjustable in 0.1 nm increments) |
| Stray Light | ≤0.005% T |
| Baseline Flatness | ±0.001 Abs |
| Photometric Repeatability | ≤0.1% T |
| Photometric Accuracy | ±0.3% T |
| Stability | ≤0.0001 Abs/h |
| Power Supply | AC 220 V / 110 V, 50/60 Hz, 500 W |
| Dimensions (L×W×H) | 500 × 550 × 260 mm |
| Brand | Metash Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | Q-6S |
| Optical System | Dual-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Wavelength Range | 190–900 nm |
| Wavelength Accuracy | ±0.3 nm |
| Wavelength Repeatability | ≤0.1 nm |
| Spectral Bandwidth | 0.1–5.0 nm (continuously adjustable in 0.1 nm increments) |
| Stray Light | ≤0.005% T |
| Photometric Accuracy | ±0.3% T |
| Photometric Repeatability | ≤0.1% T |
| Baseline Drift | ≤0.0001 Abs/h |
| Brand | Metash Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer | Yes |
| Type | Domestic |
| Model | Q-8 |
| Optical Design | Dual-beam, dual-monochromator |
| Detector | Photomultiplier Tube (PMT) |
| Wavelength Range | 190–900 nm (extendable to 185 nm) |
| Wavelength Accuracy | ±0.2 nm |
| Wavelength Repeatability | ≤0.05 nm |
| Spectral Bandwidth | 1.8 nm |
| Stray Light | ≤0.00005% T |
| Photometric Accuracy | ±0.3% T |
| Photometric Repeatability | ≤0.1% T |
| Baseline Drift | ≤0.0001 Abs/h |
| Brand | Metash Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | Q-8S |
| Optical Design | Dual-Beam with Dual Monochromator (Hybrid Czerny-Turner) |
| Detector | Photomultiplier Tube (PMT) |
| Wavelength Range | 190–900 nm (extendable to 185 nm) |
| Wavelength Accuracy | ±0.2 nm |
| Wavelength Repeatability | ≤0.05 nm |
| Spectral Bandwidth | 0.1–5.0 nm (continuously adjustable in 0.1 nm increments) |
| Stray Light | ≤0.00005% T |
| Photometric Accuracy | ±0.3% T |
| Photometric Repeatability | ≤0.1% T |
| Baseline Drift | ≤0.0001 Abs/h |
| Brand | Metash Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | SPH Series |
| Price Range | USD 7,000–14,000 (FOB Shanghai) |
| Cavity Rating | Industrial-Grade |
| Batch Capacity | 6 samples per run |
| Microwave Source | Single Magnetron (for paired MWD systems) |
| Max Operating Temperature | 250 °C / 300 °C (SPH-1/SPH-2 vs. SPH-3) |
| Max Pressure Tolerance (of compatible vessels) | 6 MPa |
| Heating Surface Coating | PFA (Perfluoroalkoxy) |
| Temperature Control | AI-enhanced PID with ramp/soak programming |
| Temp Resolution | 0.1 °C |
| Temp Accuracy | ±0.5 °C |
| Power Input | 1.6–2.0 kW |
| Weight | 13–39 kg |
| Power Supply | AC 220 V ±10% |
| Compatible Main Systems | MWD-500/520, MWD-630/Trump, MWD-700/750, MWD-800/850 |
| Brand | Metash Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory TOC Analyzer |
| Model | TOC-1500 |
| Detection Principle | Direct Conductivity Detection |
| Oxidation Method | UV Photocatalytic Oxidation |
| Measurement Range | 0.001–1.5 ppm (as C) |
| Accuracy | ±3% of reading |
| Resolution | 0.001 ppb |
| Detection Limit | 1 ppb (as C) |
| Repeatability | ≤3% RSD |
| Display | 7-inch color touchscreen |
| Data Storage | 8 GB internal flash memory |
| Analysis Time | ≤3 minutes per sample |
| Compliance | USP <643>, CP 2025 Appendix IX Q, FDA 21 CFR Part 11 (audit trail & user authentication enabled) |
| Brand | Metash Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | TOC-1700 |
| Instrument Type | Online & Offline TOC Analyzer |
| Detection Principle | Direct Conductivity Detection |
| Oxidation Method | UV Photocatalytic Oxidation |
| Measurement Range | 0.001–1.5 ppm |
| Accuracy | ±3% |
| Resolution | 0.001 ppb |
| Detection Limit | 0.05 ppb |
| Repeatability | ≤3% RSD |
| Display | 7-inch Color Touchscreen |
| Data Storage | 8 GB Internal Flash Memory |
| Analysis Time | ≤3 minutes per sample |
| Compliance | CP2025 General Chapter <0901>, USP <643>, FDA 21 CFR Part 11 (Audit Trail & User Authentication) |
| Brand | Metash Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory TOC Analyzer |
| Model | TOC-3000 |
| Detection Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Oxidation Method | UV/Persulfate Oxidation |
| Measurement Range | 0–10,000 ppm C |
| Accuracy | ≤5% |
| Resolution | 0.01 ppb C |
| Detection Limit | 5 ppb C |
| Repeatability | ≤3% |
| Sample Volume | Up to 20 mL |
| Carrier Gas Requirement | High-Purity Nitrogen |
| Power Supply | 220 V ±10%, 50/60 Hz |
| Software Options | Standard Control & Database Management / FDA 21 CFR Part 11 Compliant Audit Trail Edition |
| Optional Accessory | 20-Position Automated Sampler |
| Brand | Metash Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory TOC Analyzer |
| Model | TOC-5000 RD |
| Detection Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Oxidation Method | High-Temperature Catalytic Combustion |
| Measurement Range | 0–1000 mg/L (expandable to 100,000 mg/L) |
| Accuracy | ≤5% |
| Resolution | 0.01 ppb |
| Detection Limits | TC: 50 µg/L |
| IC | 20 µg/L |
| Repeatability | ≤3% |
| Brand | Metash Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | TOC-5000 RN |
| Instrument Type | Laboratory Benchtop TOC Analyzer |
| Detection Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Oxidation Method | High-Temperature Catalytic Combustion (680–900 °C) |
| Measurement Range | 0–1000 mg/L as C |
| Accuracy | ≤5% of reading |
| Resolution | 0.01 ppb (as C) |
| Detection Limits | TC: 50 µg/L |
| IC | 20 µg/L |
| Repeatability | ≤3% RSD |
| Sample Form | Aqueous liquid only |