Pfeiffer Vacuum
Filter
Showing 31–60 of 148 results
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | OmniStar GSD320 |
| Detection Range | 1–100 u (optional up to 300 u) |
| Ion Source | Hot Cathode Quadrupole |
| Mass Resolution | Unit Mass Resolution (M/ΔM ≥ 150) |
| Detection Limit | < 1 ppm (typical, N₂ background) |
| Interface Temperature | Up to 200 °C |
| Data Acquisition Rate | Up to 100 spectra/s |
| Vacuum Requirement | ≤ 1 × 10⁻⁵ mbar (at analyzer inlet) |
| Pumping System Compatibility | Hicube 300 turbomolecular pump station (integrated or external) |
| Compliance | CE, RoHS, ISO 9001 manufacturing environment |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | PrismaPro |
| Detection Limit (C-SEM) | 3 × 10⁻¹⁵ hPa |
| Mass Range | up to 300 amu |
| Detector Options | Faraday Cup (F) and Combined Secondary Electron Multiplier / Faraday (C-SEM/F) |
| Quadrupole Dimensions | 6 mm Ø × 125 mm |
| Operating Pressure Range (C-SEM) | ≤ 5 × 10⁻⁵ hPa |
| Bakeout Temperature | 300 °C |
| Flange | DN 40 CF-F |
| Weight | 2.5–3.2 kg |
| Operating Temperature (Analyzer) | ≤ 200 °C (≤ 150 °C with SEM active) |
| Dwell Time | 1 ms – 16 s/amu |
| Interference at Adjacent Masses | < 10–50 ppm |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | Thermostar GSD301 |
| Mass Range | 1–300 u |
| Ion Source | Gas-Tight Dual-Filament |
| Inlet Temperature | Up to 350 °C (Quartz Capillary) |
| Detection Modes | Full Scan (1–100 / 1–200 / 1–300 u), MID (128 ions), MCD (128 gases) |
| Vacuum System | Integrated HiPace 80 Turbo-Molecular Pump |
| Software | QuadStar™ (Qualitative & Quantitative, Real-Time & Post-Processing) |
| Compliance | Designed for GLP/GMP environments |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | TPR 270 |
| Measurement Range | 1 × 10⁻⁴ to 1000 hPa |
| Accuracy | ±10 % |
| Operating Temperature | up to 80 °C |
| Maximum Pressure Resistance | 400 kPa |
| Weight | 135 g |
| Flange Options | DN 16 ISO-KF, DN 16 CF-F |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | France |
| Pump Type | Oil-Free Dry Scroll |
| Ultimate Vacuum | 1 × 10⁻² mbar |
| Pumping Speed | 15–40 m³/h (ACP 15: 14 m³/h, ACP 28: 27 m³/h, ACP 40: 37 m³/h) |
| Maximum Inlet Pressure | 1000 mbar (abs) |
| Base Weight | 23–32 kg |
| Motor Supply | Single- or Three-Phase |
| Certifications | CE, UL/CSA, SEMI S2 |
| Gas Ballast Option | Standard (SD), Corrosion-Resistant (G), Water-Vapor-Tolerant (CV) |
| Maintenance Interval | 20,000–22,000 hours (full overhaul) |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | ACP 15, ACP 28, ACP 40 |
| Ultimate Pressure (with gas ballast) | ≤ 0.1 mbar |
| Pumping Speed | 14–37 m³/h |
| Max. Water Vapor Handling Capacity | 1000 g/h |
| Gas Ballast Flow Rate | > 2 Nm³/h (at 1 bar abs) |
| Leak Rate (He) | < 5 × 10⁻⁷ mbar·L/s |
| Weight | 23–32 kg |
| Certifications | CE, UL/CSA, SEMI S2 |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | ActiveLine |
| Pressure Range | 10⁻¹¹ to 55,000 mbar |
| Output Signal | 0–10 V analog with integrated error diagnostics |
| Interface | Integrated measurement interface |
| Mounting Options | DN 16, DN 25/40, G 1/4″ |
| Operating Temperature | +5 °C to +60 °C (varies by sensor type) |
| Sensor Types | APR (Pirani), CMR (Capacitance Manometer), TPR (Combined Pirani/Thermocouple), PKR/IKR (Cold Cathode Ionization), PBR/IMR (Hot Cathode Ionization) |
| Pressure Units | Selectable (mbar, Pa, Torr, psi, etc.) |
| Compliance | CE, RoHS, EMC Directive 2014/30/EU |
| Software Integration | Compatible with Pfeiffer Vacuum Control Suite and third-party SCADA/PLC systems |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported |
| Model | Adixen Pascal SD (1005 SD & 1015 SD) |
| Pump Type | Oil-Lubricated Rotary Vane Pump |
| Pumping Speed | 6 m³/h (1005 SD, 50 Hz) / 16.5 m³/h (1015 SD, 60 Hz) |
| Ultimate Pressure | 5 × 10⁻² hPa (with gas ballast) |
| Motor Power | 0.45 kW |
| Weight | 21 kg (1005 SD) / 24.5 kg (1015 SD) |
| Inlet/Outlet Flange | DN 25 ISO-KF |
| Gas Ballast Valve | Standard |
| Lubrication | Integrated mineral oil reservoir (supplied with pump) |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | France |
| Model | ASI 35 |
| Detection Limit (Vacuum Mode, High Sensitivity) | 5×10⁻¹² mbar·L/s |
| Detection Limit (Sniffer Mode) | 1.5×10⁻⁸ mbar·L/s |
| Helium Pumping Speed (High Sensitivity Mode) | 6 L/s |
| Minimum Starting Pressure (High Sensitivity Mode) | 0.2 mbar |
| Analyzer Interface | DN 25 ISO-KF & DN 16 ISO-KF |
| Communication Interfaces | RS-232, Ethernet, PROFIBUS, USB |
| I/O Configuration | 6 digital inputs, 3 analog outputs, 5 relay outputs, 4 transistor/open-collector outputs |
| Dimensions (Vacuum Module) | 279 × 264 × 197 mm |
| Weight (Vacuum Module) | 15 kg |
| Operating Temperature | 10–45 °C |
| Power Supply | 90–240 V AC, 50/60 Hz |
| Max. Power Consumption | 300 W |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | ASI35 |
| Leak Rate Detection Limit (Vacuum Mode) | 5 × 10⁻⁷ mbar·L/s |
| Configuration | Modular OEM Integration Unit |
| Intended Use | Embedded Helium Leak Testing in Custom Electronic Component Test Systems |
| Compliance | Designed to meet ISO 9001 manufacturing standards |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | ASI35 |
| Detection Mode | Vacuum (Sniffer/Probe or Vacuum Chamber Compatible) |
| Minimum Detectable Leak Rate | 5 × 10⁻¹² mbar·L/s (typical, helium) |
| Integrated Interface | RS232/RS485, Ethernet, Digital I/O for PLC Integration |
| Compliance | CE, RoHS, ISO 9001 Manufacturing |
| Application-Specific Configuration | OEM-ready module for automated fuel tank leak testing systems |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | France |
| Model | ASM 182 T / ASM 182 TD+ |
| Forevacuum Pump Speed | 20–25 m³/h (oil-sealed or dry scroll) |
| Helium Throughput | 4.4 L/s |
| Minimum Detectable Leak Rate (He) | 5×10⁻¹³ Pa·m³/s (vacuum mode), 1×10⁻⁸ Pa·m³/s (sniffer mode) |
| Inlet Flange | DN 40 ISO-KF |
| Max Inlet Pressure | 6 hPa |
| Power Supply | 200–240 V, 50/60 Hz (also available 110–130 V variants) |
| Warm-up Time | ≤4 min |
| Weight | 76–88 kg |
| Dimensions (L×W×H) | 594×434×444 mm (T) / 601×487×456 mm (TD+) |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | France |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ASM 2000 |
| Price Range | USD 42,000 – 70,000 (FOB) |
| Detection Principle | Quadrupole Mass Spectrometry (He⁺ at m/z = 4) |
| Measurement Method | Vacuum Mode & Sniffer Probe Mode |
| Quantitative Sensitivity (Vacuum Mode) | 1×10⁻⁸ – 1×10⁻⁵ mbar·L/s |
| Qualitative Sensitivity (Vacuum Mode, Coarse Scan) | 1×10⁻⁵ – 1×10⁻³ mbar·L/s |
| Gross Leak Detection Threshold | ≥1×10⁻³ mbar·L/s |
| Minimum Detectable Leak (Sniffer Mode) | >1×10⁻⁵ mbar·L/s |
| Helium Supply Pressure | 0.5–8 bar (rel) |
| Compressed Dry Air (CDA) Requirement | ISO 8573-1 Class 1.3.1, 4.5–10 bar (rel) |
| Nitrogen Purge Support | 0.5–8 bar (rel) |
| Power Input | 90–250 V AC, 50–60 Hz |
| Typical Power Consumption | 3,750 W |
| Dimensions (L×W×H, incl. trolley) | 1409 × 575 × 1194 mm |
| Acoustic Noise Level | <53 dB(A) |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Manufacturer | Pfeiffer Vacuum GmbH |
| Type | Imported Industrial Leak Detector |
| Model | ASM 306 S |
| Detection Gases | Helium (He) and Hydrogen (H₂) |
| Minimum Detectable Leak Rate (He) | 1 × 10⁻⁷ mbar·L/s |
| Minimum Detectable Leak Rate (H₂) | 5 × 10⁻⁷ mbar·L/s |
| Warm-up Time | 2 min |
| Response Time | < 1 s |
| Sniffer Probe Flow Rate | 300 sccm ± 10% |
| Noise Level | 55 dB(A) |
| Interfaces | RS-232, Digital I/O, Fieldbus Options |
| Operating Temperature | 10–40 °C |
| Power Supply | 100–240 V AC, 50/60 Hz |
| Max. Power Consumption | 300 VA |
| Weight | 22 kg |
| Dimensions (L×W×H) | 350 × 305 × 421 mm |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | ASM 310 |
| Minimum Detectable Leak Rate (Vacuum Mode) | 5×10⁻¹³ Pa·m³/s |
| Minimum Detectable Leak Rate (Sniffer Mode) | 1×10⁻⁸ Pa·m³/s |
| Helium Pumping Speed | 1.1 L/s |
| Inlet Pressure Limit | 15 hPa |
| Roughing Pump | MVP 020 Diaphragm Pump (1.7 m³/h) |
| Turbomolecular Pump | ATH Series |
| Inlet Flange | DN 25 ISO-KF |
| Operating Temperature | 10–40 °C |
| Noise Level | <45 dB(A) |
| Power Supply | 90–240 V AC, 50/60 Hz |
| Max. Power Consumption | 300 VA |
| Warm-up Time | <2 min |
| Dimensions (W×H×D) | 350×254×415 mm |
| Weight | 21 kg |
| Interfaces | RS-232, USB, I/O |
| Display | High-brightness color touchscreen with image function, 10 language options |
| Compliance | Designed for ISO 16051, ASTM E1514, and GLP/GMP-aligned operation |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | France |
| Model | ASM 340, ASM 390 |
| Detection Sensitivity | ≤5×10⁻¹² mbar·L/s (He) |
| Operating Mode | Vacuum Mode / Sniffing Mode / Accumulation Mode |
| Mass Filter | Quadrupole Mass Spectrometer |
| Pumping System | Integrated Turbo-Molecular Pump + Backing Pump |
| Helium-Specific Detection | Yes |
| Compliance | CE, RoHS, ISO 9001 certified manufacturing |
| Interface | RS232, Ethernet, Digital I/O for PLC integration |
| Software | VACUSAFE™ with audit trail, user management, and test report generation (PDF/CSV) |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | France |
| Model | ASM 340 |
| Detection Limit (Vacuum Mode) | 1×10⁻¹² mbar·L/s for ⁴He |
| Detection Limit (Sniffer Mode) | 5×10⁻⁹ mbar·L/s for ⁴He |
| Max Inlet Pressure | 25 mbar |
| Helium Pumping Speed | 2.5 L/s |
| Warm-up Time | ~3 min |
| Response Time | <1 s |
| Interface | RS-232, USB, Basic I/O, Fieldbus Options |
| Operating Temperature | 0–45 °C (Vacuum Mode), 0–40 °C (Sniffer Mode) |
| Power Supply | 100–240 V AC, 50/60 Hz |
| Weight | 32–56 kg (depending on configuration) |
| Dimensions | 547 × 350 × 389 mm |
| IP Rating | IP20 |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | ASM 340 |
| Detection Sensitivity | ≤5×10⁻¹² mbar·L/s (He) |
| Operating Modes | Vacuum Mode, Sniffer Mode, Accumulation Mode |
| Minimum Detectable Leak Rate | 1×10⁻⁶ mbar·L/s (typical field performance in power plant vacuum systems) |
| Pumping Configuration | Integrated turbomolecular pump with backing pump |
| Compliance | CE, RoHS, ISO 9001 certified manufacturing |
| Interface | RS232, Ethernet, analog output (0–10 V) |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | France |
| Model | ASM 340 |
| Detection Limit (He) | 5×10⁻¹³ Pa·m³/s |
| Operating Modes | Vacuum Mode & Sniffer Mode |
| Detectable Gases | ⁴He, ³He, H₂ |
| Inlet Max Pressure | 25 hPa (WET/D) / 5 hPa (I) |
| Helium Pumping Speed | 2.5 L/s |
| Forepump Requirement | Oil-sealed pump (15 m³/h) or Diaphragm pump (3.4 m³/h) |
| Weight | 56 kg (WET), 45 kg (D), 32 kg (I) |
| Compliance | Designed for ISO 10110-7, ASTM E1514, and GLP/GMP-aligned leak testing workflows |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | France |
| Model | ASM 340 |
| Detection Principle | Helium-Specific Mass Spectrometry (m/z = 4) |
| Sensitivity | ≤5.0×10⁻¹² mbar·L/s (equivalent to ≤5.0×10⁻⁸ atm·cm³/s) |
| Measurement Method | Backpressure Test Mode |
| Compliance | ISO 20484, ASTM E499, EN 1330-8, FDA 21 CFR Part 11 (software audit trail optional) |
| Vacuum Interface | DN 25 KF or CF flange |
| Operating Temperature Range | 15–35 °C |
| Power Supply | 100–240 V AC, 50/60 Hz |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | France |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ASM 340 Dedicated for Fire Extinguisher Cylinder Leak Detection |
| Price Range | USD 13,500 – 40,500 |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | France |
| Model | ASM 340 |
| Detection Principle | Helium-Specific Quadrupole Mass Spectrometry |
| Operating Mode | Vacuum (Sniffer & Vacuum Chamber) |
| Typical Sensitivity | ≤5 × 10⁻¹² mbar·L/s (He) |
| Pumping Configuration | Integrated with Duo 2.5 Dual-Stage Rotary Vane Pump |
| Compliance | CE, RoHS, ISO 9001 Manufacturing Environment |
| Software Interface | Pfeiffer Vacuum ControlSuite (PC-based, USB/Ethernet) |
| Data Logging | Timestamped leak rate records with user-defined pass/fail thresholds |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | France |
| Model | ASM 340 (Thermal Pipe-Specific Configuration) |
| Detection Sensitivity | ≤1×10⁻⁸ mbar·L/s (He) |
| Operating Mode | Vacuum Test (Sniffer & Accumulation Compatible) |
| Pumping System | Integrated HiPace 80 Molecular Pump + ACP 20 Dry Scroll Backing Pump |
| Compliance | CE, RoHS, ISO 9001 Certified |
| Interface Options | Analog I/O, RS-232, Ethernet (Modbus TCP), Optional Footswitch Integration |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | France |
| Model | ASM 340 |
| Application-Specific Configuration | Lithium Battery Hermeticity Testing System |
| Distribution Status | Authorized Distributor (Shanghai Bodo Vacuum Equipment Co., Ltd.) |
| Price Range | USD 13,500 – 40,500 (FOB Shanghai) |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | France |
| Model | ASM 340 |
| Detection Sensitivity | ≤1×10⁻¹² mbar·L/s (He) |
| Leak Rate Measurement Range | 1×10⁻¹² to 1×10⁻⁴ mbar·L/s |
| Vacuum Interface | DN 40 ISO-KF or CF |
| Mass Analyzer Type | Magnetic Sector Quadrupole |
| Response Time | <100 ms (typical) |
| Operating Temperature | 10–40 °C |
| Compliance | CE, RoHS, EN 61000-6-2/6-3, ISO 9001 certified manufacturing |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | France |
| Model | ASM 340 (WET/D/I variants) |
| Minimum Detectable Leak Rate (He) | 5 × 10⁻¹³ Pa·m³/s (vacuum mode) |
| Detection Gases | ⁴He, ³He, H₂ |
| Inlet Pumping Speed | 2.5 L/s |
| Max Inlet Pressure | 25 hPa (WET/D), 5 hPa (I) |
| Pre-vacuum Requirements | Oil rotary pump (15 m³/h) or diaphragm pump (3.4 m³/h) |
| Weight | 56 kg (WET), 45 kg (D), 32 kg (I) |
| Detection Modes | Vacuum mode & sniffer (probe) mode |
| Compliance | Designed for ISO 20484, ASTM E1779, and GLP/GMP-aligned vacuum integrity verification workflows |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | France |
| Model | ASM 340 |
| Detection Principle | Quadrupole Mass Spectrometry (He⁺ at m/z = 4) |
| Minimum Detectable Leak Rate (Vacuum Mode) | 5 × 10⁻¹³ Pa·m³/s |
| Operating Pressure Range (Analyzer) | 1 × 10⁻⁷ to 1 × 10⁻³ hPa |
| Mass Resolution | Unit mass resolution (FWHM ≤ 1 amu at m/z = 4) |
| Interface | DN 40 CF vacuum flange |
| Control | Touchscreen GUI with real-time leak rate display and trend logging |
| Compliance | Designed per ISO 20486:2017 (Leak detection — Vocabulary and test methods), compatible with ASTM E499-21 (Standard Test Method for Leak Detection Using Helium Mass Spectrometer) and EU Machinery Directive 2006/42/EC |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | ASM 340 |
| Instrument Type | Portable |
| Detection Method | Vacuum Mode |
| Minimum Detectable Leak Rate | 5 × 10⁻¹³ Pa·m³/s |
| Startup Time | 3 min |
| Response Time | < 1 s |
| Maximum Inlet Pressure | 2500 Pa |
| Helium Purge Speed | 2.5 L/s |
| Leak Rate Display Range | 1 × 10⁻³ to 1 × 10⁻¹³ Pa·m³/s |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | France |
| Model | ASM 340WET |
| Detection Principle | Helium-Specific Quadrupole Mass Spectrometry |
| Operating Mode | Vacuum (Hard-Line) Mode |
| Pumping Configuration | Integrated with ACP 28 Dry Scroll Vacuum Pump |
| Compliance | CE, RoHS, ISO 9001 Certified |
| Interface | RS-232 / Ethernet (Optional), Analog Output (0–10 V) |
| Minimum Detectable Leak Rate | ≤5 × 10⁻¹² mbar·L/s (He) |
| Response Time | < 0.5 s (typical) |
| Mass Filter | Quadrupole with 4 amu resolution at 4 He peak |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | France |
| Model | ASM 390, ASM 392 |
| Detection Gas | 4He, 3He, H₂ |
| Minimum Detectable Leak Rate (Vacuum Mode) | 1×10⁻¹² mbar·L/s |
| Minimum Detectable Leak Rate (Sniffer Mode) | 1×10⁻⁸ mbar·L/s |
| Helium Pumping Speed | 10 L/s (ASM 390), 25 L/s (ASM 392) |
| Forepump Speed | 35 m³/h |
| Max Inlet Pressure | 20 mbar |
| Warm-up Time (Un-calibrated, 20°C) | 2 min |
| Inlet Port | DN 40 ISO-KF |
| Response Time | < 1 s |
| Interface Options | RS-232, Digital I/O, Ethernet |
| Noise Level | ≤ 55 dB(A) |
| Weight | 125 kg (ASM 390), 130 kg (ASM 392) |
| Dimensions (L×W×H) | 1072 × 455 × 1025 mm |
| Certifications | CE, ETL, UL 61010, SEMI S2 |