| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Pump Type | Oil-Free Dry Vacuum Pump |
| Model | A 100 L, A 200 L |
| Pumping Speed | 100 m³/h (A 100 L), 200 m³/h (A 200 L) |
| Ultimate Pressure | 6.6 × 10⁻³ hPa (A 100 L), 8 × 10⁻³ hPa (A 200 L) |
| Inlet Flange | DN 50 |
| Noise Level | 55–58 dB(A) |
| Weight | 100 kg |
| Motor Power | 3 kW |
| Cooling | Water-Cooled |
| Compliance | CE, RoHS, ISO 9001-certified manufacturing |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Pump Type | Oil-Free Multi-Stage Roots Vacuum Pump System |
| Model | ACG 600 G |
| Ultimate Pressure (with N₂ purge, 50 Hz) | 9 × 10⁻³ hPa |
| Ultimate Pressure (with N₂ purge, 60 Hz) | 6 × 10⁻³ hPa |
| Pumping Speed (50 Hz) | 480 m³/h |
| Pumping Speed (60 Hz) | 560 m³/h |
| Inlet Flange | DN 100 ISO-K |
| Outlet Flange | DN 40 ISO-KF |
| Cooling | Water-cooled (max. flow: 5 L/min) |
| Motor Power | 2.2 kW (3-phase, 380–480 V) |
| Dimensions (W × D × H) | 872 × 370 × 779 mm |
| Weight | 320 kg |
| Noise Level | 68 dB(A) |
| Max. Gas Throughput | 60 sL/min |
| Ambient Temperature Range | 5–40 °C |
| Compliance | CE, RoHS, ISO 9001-certified manufacturing |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | France |
| Model | ACP 120 |
| Pump Type | Oil-Free Dry Scroll Vacuum Pump |
| Ultimate Pressure | ≤3 × 10⁻² mbar |
| Pumping Speed | 95 m³/h |
| Motor Power | 3 kW |
| Noise Level | <65 dB(A) |
| Weight | 205 kg |
| Inlet Flange | DN 50 |
| External Dimensions (L×W×H) | 1000 × 600 × 700 mm |
| Maintenance Interval | ~17,000 operating hours |
| Compliance | CE, RoHS, ISO 9001-certified manufacturing |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | ASM 102 S |
| Minimum Detectable Leak Rate (He) | 1×10⁻⁸ Pa·m³/s (7.5×10⁻⁸ Torr·L/s, 1×10⁻⁷ mbar·L/s) |
| Measurement Range (He) | 1×10⁻⁷ to 1 mbar·L/s |
| Detection Gas | ⁴He |
| Forevacuum Pump | Oil-free dry scroll pump |
| Operating Temperature | 0–45 °C |
| Warm-up Time | 1.5 min |
| Detection Mode | Sniffer Probe (Handheld) |
| Weight | 18 kg |
| Probe Cable Length | 5 m |
| Nozzle Diameter | 9 mm |
| Power Supply Options | 110/130 V AC or 200/240 V AC |
| Display Language Options | English, French, German |
| Remote Control | Integrated handheld controller |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ASM 142 S |
| Detection Limit (He) | 1 × 10⁻⁸ Pa·m³/s |
| Measurement Range (He) | 1 × 10⁻⁷ to 1 mbar·L/s |
| Forepump | Oil-Sealed Rotary Vane Pump |
| Detectable Gas | ⁴He |
| Operating Temperature | 0–45 °C |
| Acoustic Noise Level | < 57 dB(A) |
| Dimensions (W × D × H) | 517 × 357 × 420 mm |
| Warm-up Time | 2 min |
| Detection Mode | Sniffer (Probe-Based) |
| Weight | 55 kg |
| Standard Probe | 5 m Flexible Hose with 9 cm Rigid Nozzle |
| Power Supply Options | 110–130 V AC (North America) or 200–240 V AC (Europe) |
| Interface | RS-232 / USB / Optional PLC Integration |
| Display Language Options | English, French, German, Chinese |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | ASM 192T |
| Forepump Speed | 20 or 40 m³/h |
| Helium Pumping Speed | 4.4 L/s |
| Minimum Detectable Leak Rate (He) | 5 × 10⁻¹² hPa·L/s |
| Inlet Flange | DN 40 ISO-KF |
| Maximum Inlet Pressure | 6 hPa |
| Detection Modes | Vacuum Mode & Sniffer Mode |
| Warm-up Time | 3 min |
| Power Supply | 200–240 V, 50/60 Hz |
| Dimensions (L×W×H) | 594 × 692 × 933 mm |
| Weight | 125 kg |
| Display | Color Graphical Touchscreen |
| Language Options | Multi-language UI |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | France |
| Model | ASM 306S |
| Minimum Detectable Leak Rate (He) | 1×10⁻⁷ mbar·L/s |
| Minimum Detectable Leak Rate (H₂) | 5×10⁻⁷ mbar·L/s |
| Sensitivity | 0.2 g/y (refrigerant loss equivalent) |
| Startup Time | 2 min |
| Response Time | < 1 s |
| Sniffer Probe Flow Rate | 300 sccm ±10% |
| Noise Level | 55 dB(A) |
| Interfaces | RS-232, Digital I/O, Fieldbus Options |
| Operating Temperature | 10–40 °C |
| Power Supply | 100–240 V, 50/60 Hz |
| Max. Power Consumption | 300 VA |
| Weight | 22 kg |
| Dimensions (L×W×H) | 350 × 305 × 421 mm |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | France |
| Model | ASM 310 |
| Application | In-service turbine vacuum system leak detection |
| Compliance | CE, RoHS, ISO 9001-certified manufacturing |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | France |
| Model | ASM 310 |
| Helium Minimum Detectable Leak Rate (Vacuum Mode) | 5×10⁻¹³ Pa·m³/s |
| Helium Minimum Detectable Leak Rate (Sniffer Mode) | 1×10⁻⁸ Pa·m³/s |
| Helium Pumping Speed | 1.1 L/s |
| Inlet Pressure Limit | 15 hPa |
| Roughing Pump | MVP 020 Diaphragm Pump (1.7 m³/h) |
| Inlet Flange | DN 25 ISO-KF |
| Operating Temperature | 10–40 °C |
| Noise Level | < 45 dB(A) |
| Power Supply | 90–240 V AC, 50/60 Hz |
| Max. Power Consumption | 300 VA |
| Warm-up Time | < 2 min |
| Dimensions (W×H×D) | 350 × 254 × 415 mm |
| Weight | 21 kg |
| Interfaces | RS-232, USB, Digital I/O |
| Display | High-brightness color touchscreen with image function, 10 language options |
| Detection Gases | ⁴He, ³He, H₂ |
| Response Time | < 1 s |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | ASM 340 D |
| Minimum Detectable Leak Rate (Vacuum Mode) | 5 × 10⁻¹³ Pa·m³/s |
| Minimum Detectable Leak Rate (Sniffer Mode) | 5 × 10⁻¹⁰ Pa·m³/s |
| Helium Pumping Speed | 2.5 L/s |
| Forepump Type | Oil-Free Dry Scroll Pump |
| Forepump Speed | 3.4 m³/h |
| Max Inlet Pressure | 25 hPa |
| Detection Gases | ⁴He, ³He, H₂ |
| Warm-up Time | ~3 min |
| Dimensions & Weight | 45 kg |
| Data Storage | Integrated SD Card |
| User Interface | Modular, Removable and Customizable |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | ASM 340 |
| Minimum Detectable Leak Rate (He) | 5 × 10⁻¹³ Pa·m³/s |
| Detection Modes | Vacuum Mode & Sniffer Mode |
| Detectable Gases | ⁴He, ³He, H₂ |
| Pump-Down/Startup Time | ~3 min |
| Helium Pumping Speed | 2.5 L/s |
| Max Inlet Pressure | 25 hPa |
| Forepump Required | 15 m³/h |
| Weight | 56 kg |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | France |
| Model | ASM 340 |
| Minimum Detectable Leak Rate (Vacuum Mode) | 5 × 10⁻¹³ Pa·m³/s |
| Minimum Detectable Leak Rate (Sniffer Mode) | 5 × 10⁻¹⁰ Pa·m³/s |
| Helium Pumping Speed | 2.5 L/s |
| Max Inlet Pressure (Vacuum Mode) | 25 hPa |
| Max Inlet Pressure (Gross Leak Test) | 100 hPa |
| Detection Gases | ⁴He, ³He, H₂ |
| Startup Time | ≤3 min |
| Front-Stage Pump Options | Oil-Sealed Rotary Vane Pump (15 m³/h) or Dry Diaphragm Pump (3.4 m³/h) |
| Weight | 56 kg (ASM 340), 45 kg (ASM 340 D), 32 kg (ASM 340 I) |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ASM 340 |
| Price Range | USD 13,500 – 40,500 |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | USA (Manufactured under German engineering standards) |
| Model | ASM 340 |
| Detection Limit | ≤5 × 10⁻¹³ Pa·m³/s |
| Application | Vacuum-mode helium leak testing of pressurized natural gas distribution piping systems |
| Compliance | Designed to support ISO 10648-2, ASTM E1795, and EN 1330-8 compliant leak verification protocols |
| Pumping Configuration | Compatible with Splitflow 80 turbo-molecular pump + backing pump (e.g., Leybold DUA series) |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany (manufactured in Germany, distributed globally) |
| Model | ASM 340 |
| Detection Principle | Quadrupole Mass Spectrometry with Helium Carrier Gas |
| Minimum Detectable Leak Rate | ≤5 × 10⁻¹² mbar·L/s (helium) |
| Operating Mode | Positive-Pressure Sniffing & Vacuum-Coupled Testing |
| Pumping System | Integrated Turbomolecular Pump + Forepump |
| Mass Filter | 4-amu Resolution Quadrupole Analyzer |
| Response Time | <100 ms (typical) |
| Compliance | CE, RoHS, ISO 9001 Certified |
| Interface | RS-232, Ethernet, Analog Output (0–10 V) |
| Software Compatibility | Pfeiffer VacuGraph® PC Control Suite |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | ASM 340D |
| Ultimate Helium Detection Sensitivity (Vacuum Mode) | 5 × 10⁻¹³ Pa·m³/s |
| Ultimate Helium Detection Sensitivity (Sniffer Mode) | 5 × 10⁻¹⁰ Pa·m³/s |
| Forepump Type | Dual Dry Scroll Pumps |
| Forepump Speed | 3.4 m³/h |
| Helium Pumping Speed | 2.5 L/s |
| Interface | Removable & Customizable Touch Panel |
| Data Storage | Integrated SD Card Slot |
| Optional Accessories | Wired/Wireless Remote Control, Helium Sniffer Probe |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | France |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ASM 380 Dedicated for Circuit Breaker Leak Testing |
| Price Range | USD 14,000 – 42,000 |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | France |
| Model | ASM 380 |
| Helium Detection Limit (Vacuum Mode) | 5×10⁻¹³ Pa·m³/s |
| Helium Pumping Speed | 7 L/s |
| Background Pumping Speed (Forepump) | 35 m³/h |
| Maximum Inlet Pressure | 15 mbar |
| Response Time | <1 s |
| Operating Noise Level | 53 dB(A) |
| Dimensions (W×D×H) | 1065 × 455 × 1025 mm |
| Weight | 110 kg |
| Detection Gases | He, ³He, H₂ |
| Detection Modes | Vacuum Mode & Sniffer (Probe) Mode |
| Display | 360° Full-Color Touchscreen |
| Data Storage | SD Card |
| Vacuum System | ACP 40 Dry Scroll Forepump + High-Speed Turbomolecular Pump |
| I/O Options | Configurable I/O Board, Bluetooth, Wi-Fi, Ethernet |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Pump Type | Oil-Lubricated Rotary Lobe (Roots) Booster with Dual-Stage Forevacuum Pump |
| Model Designation | WD Series (WD 220 / WD 400 / WD 900 / WD 1800) |
| Nominal Pumping Speed (at 1 mbar, 50 Hz) | 220–1800 m³/h |
| Ultimate Pressure (with DuoLine forepump) | ≤ 5 × 10⁻⁴ mbar |
| Motor Power | 1 kW (forepump dependent |
| Weight | 220–980 kg (model-dependent) |
| Inlet Flange | DN 63–DN 160 |
| Compliance | CE, ISO 8573-1 Class 2 (compressed air quality), RoHS |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Pump Type | Oil-Lubricated Rotary Lobe Booster + Forevacuum Pump |
| Ultimate Pressure | ≤2 × 10⁻³ mbar (with UnoLine) / ≤8 × 10⁻³ mbar (with HenaLine) |
| Pumping Speed | 230–5000 m³/h (at 1 mbar, 50 Hz) |
| Inlet Flange | DN63 to DN250 |
| External Dimensions | Up to 1000 × 500 × 1000 mm |
| Weight | 240–2250 kg |
| Motor Power | 5–100 kW |
| Compliance | CE, ISO 9001, RoHS |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Pump Type | Oil-Lubricated Rotary Vane |
| Ultimate Pressure | 3 × 10⁻³ hPa |
| Pumping Speed | 2.5 m³/h (50 Hz) / 2.9 m³/h (60 Hz) |
| Noise Level | ≤ 53 dB(A) |
| Weight | 11.3 kg |
| Inlet/Outlet Flange | DN 16 ISO-KF |
| Motor | Single-Phase or Three-Phase Options Available |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Pump Type | Oil-Lubricated Rotary Vane |
| Series | DuoLine |
| Ultimate Pressure | 2–7 × 10⁻³ hPa (depending on model) |
| Operating Temperature Range (Duo 3 DC) | −20 °C to +60 °C |
| Motor Options | Single-phase / Three-phase / 24 V DC |
| Noise Level | 48–75 dB(A) |
| Weight | 7–380 kg |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Pump Type | Oil-Free Turbo Molecular Pump |
| Model | HiPace 2300 |
| Nominal Pumping Speed (N₂) | 2050 L/s |
| Ultimate Pressure (N₂) | < 1 × 10⁻⁷ hPa |
| Compression Ratio (N₂) | > 1 × 10⁸ |
| Cooling Method | Integrated Water Cooling |
| Inlet Flange | DN 250 (ISO-F / ISO-K / CF-F options) |
| Drive Electronics | Integrated TC 1200 Controller |
| Protection Rating | IP54 |
| Startup Time | 4.0 min |
| Weight | 34 kg |
| Mounting Orientation | 0°–90° (including inverted U-variant and corrosion-resistant C-variant) |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Pump Type | Oil-Free Turbo Molecular Pump |
| Model | HiPace 2300 |
| Pumping Speed (N₂) | 1900 L/s |
| Pumping Speed (He) | 2000 L/s |
| Ultimate Pressure (N₂) | 1 × 10⁻⁷ hPa |
| Ultimate Pressure (Ar) | 5 × 10⁻¹⁰ hPa |
| Rotational Speed | 31,500 rpm ±2% |
| Starting Time | ≤4 min |
| IP Rating | IP54 |
| Cooling | Integrated Water-Cooling System |
| Weight | 36.6 kg |
| Certifications | SEMI S2, UL, CSA, TÜV |
| Compliance | Fully Compatible with GLP/GMP Environments and FDA 21 CFR Part 11–Ready Data Logging Systems |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | HiPace 2800 IT |
| Pump Type | Oil-Free Turbo Molecular Pump |
| Pumping Speed (N₂) | 2,300 L/s |
| Ultimate Pressure | < 1 × 10⁻⁷ hPa |
| Flange (Inlet) | DN 250 ISO-F |
| Flange (Outlet) | DN 40 ISO-KF |
| Exhaust Connection | G 1/8" |
| H₂ Pumping Speed | 2,600 L/s |
| He Pumping Speed | 2,900 L/s |
| Ar Pumping Speed | 2,100 L/s |
| Rated Rotational Speed | 27,300 rpm ±2% |
| Warm-up Time to Full Speed | 8.6 min |
| Compression Ratio (N₂) | > 1 × 10⁸ |
| Compression Ratio (H₂) | 4 × 10³ |
| Max. Forevacuum Pressure (N₂) | 0.8 hPa |
| Cooling Method | Water Cooling (100 L/h, 15–25 °C) |
| Weight | 62 kg |
| Dimensions (W × H) | 228 × 167 mm |
| Motor Power | 1 kW |
| Interface | E74, RS-485 |
| Max. Permissible Magnetic Field | 3.4 mT |
| Sound Pressure Level | < 50 dB(A) |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Pump Type | Turbo Molecular Pump |
| Model | HiPace® 30 |
| Pumping Speed (N₂) | 32 L/s |
| Ultimate Pressure (N₂) | < 5 × 10⁻¹⁰ hPa |
| Weight | 3.2 kg |
| Operating Voltage | 24 V DC (±5%) |
| Maximum Rotational Speed | 90,000 rpm |
| Startup Time | 1.7 min |
| Bearing System | Hybrid Ceramic Ball Bearings |
| Compression Ratio (N₂) | > 1 × 10¹¹ |
| Compression Ratio (H₂) | 3 × 10⁷ |
| Compression Ratio (He) | 3 × 10⁷ |
| Inlet Flange Options | DN 63 ISO-K, DN 63 CF-F, DN 40 ISO-KF |
| Exhaust Flange | DN 16 ISO-KF, G ¼" |
| Cooling | Convection (standard), Optional Air or Water Cooling (75 L/h, 5–25 °C) |
| Communication Interface | RS-485, Remote Control |
| Protection Rating | IP 54 / IP 30 (depending on configuration) |
| Magnetic Field Tolerance | ≤ 3 mT |
| Installation Orientation | Any Position |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | HiPace 700 |
| Pump Type | Oil-Free Turbo Molecular Pump |
| Pumping Speed for N₂ | 685 L/s |
| Ultimate Pressure (N₂) | < 5 × 10⁻¹⁰ hPa |
| Weight | 17.4 kg |
| Protection Rating | IP54 |
| Certifications | SEMI S2, UL/CSA |
| Operating Voltage | 48 V DC |
| Max. Rotational Speed | 49,200 rpm ±2% |
| Startup Time | 2 min |
| Compression Ratios (Ar/N₂ >1×10¹¹, H₂ | 4×10⁵, He: 3×10⁷) |
| Gas Flow Capacity (N₂ @ full speed) | 6.5 hPa·L/s |
| Magnetic Field Tolerance | ≤6 mT |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Pump Type | Oil-Free Turbo Molecular Pump |
| Model | HiPace 80 |
| Nominal Pumping Speed (N₂) | 71 L/s |
| Compression Ratio (N₂) | >1×10¹¹ |
| Ultimate Pressure (N₂) | <1×10⁻⁷ hPa |
| Maximum Starting Pressure (N₂) | 2.2 mbar |
| Pumping Speed (He) | 58 L/s |
| Pumping Speed (H₂) | 48 L/s |
| Inlet Flange | DN 63 ISO-K / DN 63 CF-F / DN 40 ISO-KF |
| Cooling | Natural Air Cooling |
| Enclosure Rating | IP54 |
| Certifications | UL/CSA, Semiconductor S2 |
| Mounting | Omnidirectional |
| Weight | 1.75 kg |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | HPA 220 |
| Mass Range (Configurable) | 1–100 amu / 1–200 amu / 1–300 amu |
| Operating Pressure Range | 1 × 10⁻⁷ hPa to 50 hPa |
| Detection Modes | C-SEM (Min. Detectable Partial Pressure: 1 × 10⁻¹⁴ hPa) / Faraday Cup (Min. Detectable Partial Pressure: 5 × 10⁻¹² hPa) |
| Quadrupole Dimensions | 6 mm diameter × 100 mm length |
| Base Pumping System | HiPace 80 turbomolecular pump + TC 110 RS controller + MVP 020-3 rotary vane backing pump |
| Vacuum Measurement | PKR 251 full-range gauge |
| Inlet Interface | DN 40 CF flange |
| Power Supply | 115–230 V AC, 50/60 Hz |
| Weight | 15 kg |
| Software | Quadera platform with HPA Add-In module |
| Optional Accessories | Chamber heating unit, DCU 002 molecular pump controller, custom application software, additional full-range gauges |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | OktaLine |
| Pump Type | Oil-Sealed Roots Vacuum Pump |
| Pumping Speed | 250–25,000 m³/h |
| Ultimate Pressure | 10⁻²–75 mbar |
| Motor Power | 0.75–45 kW |
| Weight | 95–3,100 kg |
| Cooling Method | Air-Cooled |
| Drive System | Magnetic Coupling (Okta M variants) |
| Compliance | ATEX-certified options available for explosive atmospheres |