| Brand | SAIL HERO |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | XHGGP-90A |
| Operating Principle | Pushbroom Scanning |
| Imaging Method | Dispersive (Prism-Grating Hybrid) |
| Platform | UAV-Mounted |
| Spectral Range | 400–1000 nm |
| Spectral Resolution | ≤2 nm FWHM @ 546.1 nm |
| Spatial Resolution (IFOV) | 0.1 m at 300 m AGL |
| Image Resolution | 1000 × 1200 pixels |
| Total Field of View (TFOV) | ≥20° |
| Max Operational Altitude | 500 m AGL |
| Onboard Power | Integrated LiPo Battery with Extended Flight Duration |
| Environmental Certification | Certified by China National Environmental Monitoring Centre (CNEMC) and China Environmental Protection Industry Association (CEPIA) |
| Data Processing | End-to-end pipeline including radiometric calibration, atmospheric correction, spectral unmixing, and empirical/semi-analytical inversion algorithms for water quality parameters |
| Brand | SAIL HERO |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | XHGGP-90B |
| Operating Principle | Pushbroom Scanning |
| Imaging Method | Dispersive (Prism/Grating-based) |
| Deployment Mode | Ground-Based Fixed Tower Mount |
| Spectral Range | 400–1000 nm |
| Spectral Resolution | ≤2 nm FWHM @ 546.1 nm |
| Total Field of View (TFOV) | ≥20° |
| Instantaneous Field of View (IFOV) | 0.08 m (at 50 m installation height, 30° tilt angle) |
| Spectral Bands | >200 channels |
| Real-Time Processing Capability | Yes |
| Water Parameter Retrieval | ≥15 parameters (e.g., TSS, Turbidity, Secchi Depth, Zn, Cu, Pb, Chlorophyll-a, COD, DO, TP, TN, NH₃-N) |
| Data Transmission | Multi-destination upload support |
| Calibration | Onboard solar tracking + electronic white-board radiometric calibration |
| Software Modes | Scanning Imaging Mode & Fixed-Point Monitoring Mode |
| Georeferencing | Manual ROI-based water body delineation |
| Data Integration | Manual lab sample import for post-acquisition spectral calibration |
| Brand | SAIL HERO |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | XHIRVOC100 |
| Operating Temperature | Cooled Detector Operation |
| Measurement Method | Non-Contact Optical Imaging |
| Spectral Range | 3.2–3.5 µm |
| Thermal Sensitivity (NETD) | ≤15 mK @ 25 °C |
| Infrared Resolution | 320 × 256 |
| Enclosure Rating | IP54 |
| Explosion Protection | Intrinsic Safety (Ex ib IIB T4 Gb) |
| Application Domain | Environmental Compliance Monitoring, Industrial Leak Detection, Regulatory Field Enforcement |
| Brand | SAIL HERO |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Manufacture | China |
| Model | XHN2000B |
| Detection Principle | Gas-Phase Chemiluminescence |
| Measured Species | NO, NO₂ (via catalytic conversion), NOₓ (sum) |
| Compliance | Certified by China Environmental Monitoring Instrument Quality Supervision & Inspection Center |
| Brand | SAIL HERO |
|---|---|
| Model | XHN2100B |
| Measurement Principle | Chemiluminescence Detection (CLD) with NO–O₃ Reaction |
| Target Analyte | NH₃ (derived via TNₓ–NOₓ differential) |
| Compliance | Designed for continuous ambient air quality monitoring per China’s HJ 654-2013 and compatible with EPA Method 7010 / ISO 11088:2021 frameworks |
| Output Options | RS232, RS485, 0–5 V analog, 4–20 mA current loop (optional) |
| Environmental Compensation | Integrated temperature & pressure sensors with real-time correction |
| Calibration | Manual or remote zero/span calibration capability |
| Display & Interface | Touchscreen GUI with multilingual support (default Chinese, English firmware-ready) |
| Power Supply | 220 VAC ±10%, 50 Hz |
| Operating Temperature | 0–40 °C |
| Enclosure Rating | IP54 |
| Brand | SAIL HERO |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | XHOZ2000B |
| Pollutant Measured | O₃ |
| Measurement Principle | UV Absorption at 254 nm |
| Calibration | Manual and Remote Zero/Span Calibration |
| Optical Path Material | PTFE (Teflon) |
| Certification | CEPAA Environmental Product Certification |
| Verification | CMA-Accredited Testing Report from Ministry of Ecology and Environment Environmental Monitoring Instrument Quality Supervision & Inspection Center |
| Temperature Control | Closed-Loop Thermostatic Regulation of UV Lamp |
| Detection Technology | Dual-Beam Ratio Measurement |
| Brand | SAIL HERO |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | XHPM2000E |
| Measurement Principle | Beta-ray attenuation with dynamic heating system |
| Measured Parameter | PM₂.₅ mass concentration |
| Measurement Range | 0–0.1, 0.2, 1, 2, 5, or 10 mg/m³ (user-selectable full-scale ranges) |
| Measurement Cycle | 30 min to 60 min (configurable) |
| Sampling Flow Rate | 16.7 L/min ±2.5% |
| Limit of Detection (24-hr avg) | 5 µg/m³ |
| Compliance | Certified per Chinese EPA requirements for radioactive source management, HJ 653–2013, HJ 93–2013, and GB/T 34672–2017 |
| Regulatory Approvals | CEPAA Environmental Product Certification, CNEMC Calibration & Performance Verification Report, CIPAC Technical Appraisal Certificate for PM₂.₅ Separation Inlet |
| Brand | SAIL HERO |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | XHPM2000E |
| Measurement Method | Beta-ray Absorption (β-ray) with Dynamic Heating System |
| Measured Parameter | PM₁₀ |
| Measurement Range | 0–0.1, 0.2, 1, 2, 5, or 10 mg/m³ (user-selectable full-scale) |
| Sampling Interval | 30 min to 1 h (configurable) |
| Sample Flow Rate | 16.7 L/min ±2.5% |
| Limit of Detection (24-h avg) | 1 µg/m³ |
| Compliance | EPA EQPM-0805-154 (equivalent), HJ 653–2013, HJ 93–2013, HJ 978–2018 |
| Brand | SAIL HERO |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | XHPM2001 |
| Measurement Principle | Beta-ray Absorption (β-ray) |
| Measured Parameters | TSP, PM10, PM2.5, PM1 |
| Sampling Flow Rate | 16.7 L/min |
| Display | 7-inch High-Brightness TFT Touchscreen with Windows-based GUI |
| Calibration Method | Standardized Calibration Foil |
| Compliance | Certified by China Environmental Monitoring Station (CEMS) for PM10 Portability |
| Brand | SAIL HERO |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | XHS2100B |
| Measured Pollutant | H₂S |
| Detection Principle | Catalytic Thermal Conversion + UV Fluorescence (SO₂) |
| Conversion Efficiency | >96% |
| Zero/Span Calibration | Manual or Remote Automated |
| Data Storage | Internal Dynamic Memory ≥1 Year (1-Minute Averages) |
| Environmental Compensation | Automatic Temperature & Pressure Correction |
| Interference Mitigation | Integrated Hydrocarbon Scrubber (PAH Removal) |
| Communication Interfaces | RS232, RS485, 0–5 V Analog Output, 4–20 mA Current Loop (Optional) |
| Brand | SAIL HERO |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | XHTN-90 |
| Measurement Parameter | Total Nitrogen |
| Instrument Type | Online Analyzer |
| Measurement Principle | Spectrophotometry (Alkaline Potassium Persulfate Digestion + UV Absorption at 220 nm) |
| Measurement Range | 0–50 mg/L (expandable) |
| Accuracy | ±3.0% FS |
| Detection Limit | 0.1 mg/L |
| Brand | SAIL HERO |
|---|---|
| Origin | Hebei, China |
| Manufacturer | Yes |
| Country of Origin | China |
| Model | XHUV-90A |
| Measurement Wavelength | 254 nm (UV) + Visible Reference |
| Compensation | Temperature & Visible-Light Baseline Correction |
| Measurement Ranges | 0–200 m⁻¹ |
| Repeatability | ±1.5% FS |
| Zero Drift | ±1.5% FS |
| Span Drift | ±1.5% FS |
| Linearity | ±4% FS |
| Power Supply | AC 220 V, 50 Hz |
| Output Interfaces | RS232/RS485 digital communication |
| Display | Touchscreen LCD with Chinese UI |
| Brand | SAIL HERO |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | XHVOC1000 |
| Pricing | Available upon Request |
| Detection Principle | Gas Chromatography with Flame Ionization Detection (GC-FID) |
| Instrument Type | Continuous Online Analyzer |
| Measurement Range | Non-Methane Hydrocarbons (NMHC): 0–5 µmol/mol (configurable) |
| Brand | SAIL HERO |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | XHVOC40 |
| Pricing | Available Upon Request |
| Brand | SAIL HERO |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | XHVOC6000 |
| Detection Principle | Gas Chromatography-Mass Spectrometry (GC-MS) |
| Instrument Type | Online Analyzer |
| Typical Configuration | Multi-component VOC Monitoring System |
| Brand | SAIL HERO |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | XHZ3000 |
| Zero Air Purity | SO₂ ≤ 0.1 nmol/mol |
| Output Pressure Range | 0.06–0.42 MPa |
| Dew Point | < −20 °C |
| Brand | SAIL HERO |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | SpOILer |
| Pricing | Upon Request |
| Brand | SAIL HERO |
|---|---|
| Origin | USA |
| Manufacturer | Sunset Laboratory, Inc. |
| Model | Model 5L |
| Instrument Type | Aerosol OC/EC Thermal-Optical Analyzer |
| Compliance | NIOSH Method 5040, IMPROVE_A, EUSAAR2, EPA STN |
| Detection Principle | Thermal-Optical Transmittance (TOT) with Flame Ionization Detection (FID) |
| Calibration Standards | NIST-traceable sucrose solution and certified gas standards |
| Data Output | OC (µgC/cm²), EC (µgC/cm²), CC (µgC/cm²) |
| Software | Sunset OC/EC Data Analysis Suite with audit trail, manual peak integration, and dual-mode (transmittance/reflection) charring correction |
| Brand | SAIL HERO |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | XHAQSN-306 |
| Pricing | Available Upon Request |
| Measurement Parameters | Total Suspended Particulates (TSP), Respirable Particulate Matter (PM₄), Total Volatile Organic Compounds (TVOC), Sound Pressure Level (SPL) |
| Detection Principle | Optical Scattering (TSP/PM₄), Photoionization Detection (PID) for TVOC |
| Positioning | Integrated GPS Module |
| Calibration | Automatic Zero Calibration for TVOC Channel |
| Data Output | Real-time Streaming via Cellular/WiFi Uplink |
| Brand | SAIL HERO |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | XHAQSN-901 |
| Pricing | Available upon Request |
| Brand | SAIL HERO |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | XHCAL3000 |
| Pricing | Available upon request |
| Brand | SAIL HERO |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Manufacture | China |
| Model | XHCEMS-8000 |
| Detection Principle | Non-Dispersive Infrared (NDIR) |
| Measured Gases & Ranges | CO₂ (standard), with optional expansion to CH₄ and N₂O |
| Application Field | Environmental Compliance Monitoring |
| Regulatory Context | Designed for continuous compliance reporting per national emission standards (e.g., China’s HJ 75–2017, HJ 76–2017) and compatible with international CEMS framework requirements (e.g., EN 14181, US EPA PS-11/PS-15) |
| Brand | SAIL HERO |
|---|---|
| Model | XHCO2000B |
| Measurement Principle | Gas Filter Correlation (GFC) Infrared Absorption |
| Target Analyte | CO |
| Detection Range | 0–100 ppm (typical, configurable) |
| Detection Limit | ≤0.05 ppm |
| Accuracy | ±1% FS |
| Response Time (T90) | < 60 s |
| Operating Temperature | 0–45 °C |
| Power Supply | 220 VAC ±10%, 50 Hz |
| Output Interfaces | RS-232/RS-485, 4–20 mA analog, Ethernet (optional) |
| Compliance | CMA-certified test report (China National Environmental Monitoring Center), CEPAA Environmental Product Certification |
| Brand | SAIL HERO |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | XHFP-90P |
| Instrument Type | Online Monitoring System |
| Temperature Range | -5 to 60 °C (non-freezing) |
| pH Range | 0–14 pH |
| Dissolved Oxygen Range | 0–50 mg/L |
| Conductivity Range | 0–500 mS/cm |
| Turbidity Range | 0–500 NTU (extendable to 0–4000 NTU) |
| Brand | SAIL HERO |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | XHOZ7000 |
| Measured Pollutant | O₃ |
| Detection Principle | Chemiluminescence (NO + O₃ → NO₂* + light) |
| Interference Rejection | SO₂, NO, NO₂, H₂O vapor, toluene, xylene, particulate matter, high-concentration aromatic VOCs |
| Calibration | Manual or remote zero/span calibration |
| Compensation | Automatic temperature and pressure compensation |
| Output Options | RS-232, RS-485, 0–5 V analog, 4–20 mA current loop (optional) |
| Certification | CEPAA Environmental Product Certification (China) |
| Brand | SAIL HERO |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | XHS2000B |
| Measured Pollutant | SO₂ |
| Detection Principle | UV Fluorescence (UVF) |
| Interference Mitigation | Integrated Hydrocarbon Scrubber for PAH Removal |
| Compliance | Certified by China Environmental Monitoring Instrument Quality Supervision & Inspection Center |
| Data Storage | >1 year of minute-averaged data (internal dynamic memory) |
| Environmental Compensation | Automatic temperature and pressure compensation |
| Communication Interfaces | RS232, RS485 (standard) |
| User Interface | Chinese-language menu with self-diagnostic and alarm functions |
| Power Recovery | Auto-restart on power restoration |
| Brand | SAIL HERO |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Manufacture | China |
| Model | XHSN-301 |
| Frequency Range | 10 Hz – 20 kHz |
| Sound Pressure Level Range | 30–130 dB(A) |
| Communication | 4G (backward-compatible with 3G/2G) |
| Environmental Sensors | Integrated temperature, humidity, and barometric pressure |
| Positioning | Built-in GPS receiver |
| Calibration | Remote automated acoustic calibration capability |
| Brand | SAIL HERO |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | XHVOC 3000 |
| Pricing | Available Upon Request |