Sievers (Veolia)
Filter
Showing all 20 results
| Brand | Sievers/Veolia |
|---|---|
| Origin | USA |
| Distributor Status | Authorized Distributor |
| Import Status | Imported |
| Model | PC1LSCXM2 |
| Pricing | Upon Request |
| Brand | Sievers/Veolia |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | RSS131ER |
| Instrument Type | Online Dose Rate Meter |
| Measuring Medium | Gamma Radiation & Cosmic Rays |
| Dose Rate Range | 0–1 Sv/h (0–100 R/h) |
| Energy Range | 70 keV–10 MeV |
| Detector Type | Spherical Argon-Filled High-Pressure Ionization Chamber (23.8 atm) |
| Zero Drift | ±0.5 μR/h |
| Gain Drift | ±3% (<35 μR/h), ±0.5% (>35 μR/h) |
| Calibration Accuracy | ±3.5% |
| Sampling Interval | 5 s |
| Operating Temperature | −40 °C to +55 °C (battery-free operation) |
| Relative Humidity | 0–100% RH |
| Ingress Protection | IP66 |
| Communication Interfaces | 3× USB, RS-232, RJ-45 Ethernet |
| Onboard Memory | 1 GB (≥10 million data points) |
| Response Time | <10 s |
| Angular Dependence | <5% (85% field of view,仰视), <10% (15% field of view,俯视) |
| Power Consumption | 4 W |
| Certifications | CE, WEEE, IEC 60846-1:2014, ETL, RoHS |
| Brand | Sievers (Veolia) |
|---|---|
| Origin | USA |
| Model | Sievers 500RL |
| Detection Range | 0.03–2,500 ppb as C |
| Accuracy | ±5% |
| Precision | ≤0.03 ppb (for <3 ppb) or ≤1% RSD (for ≥3 ppb) |
| Conductivity Measurement Range | 0.01–35 µS/cm |
| Conductivity Accuracy | ±0.005 µS/cm (≤0.25 µS/cm) or ±2% (>0.25 µS/cm) |
| Conductivity Precision | <0.25% RSD |
| Max Acceptable Sample Conductivity | 25 µS/cm at 25°C (neutral pH) |
| Ozone Tolerance | 200 ppb |
| Operating Temperature Range | 1–95°C (steam-tolerant for short durations) |
| Brand | Sievers (Veolia) |
|---|---|
| Origin | USA |
| Model | Sievers 900 |
| Detection Range | 0.03 ppb to 50 ppm |
| Accuracy | ±2% |
| Precision | <1% RSD |
| Oxidation Method | UV/Persulfate |
| Detection Method | Membrane Conductivity |
| Sample Pressure | up to 250 psi |
| Flow Rate | 30–300 mL/min |
| Sample Temperature | 1–95 °C |
| Analysis Time | 4 min (standard), 4 s (rapid module) |
| IP Rating | IP65 |
| Compliance | US EPA Method 5310C, US EPA 415.3, ASTM D7573 |
| Brand | Sievers (Veolia) |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Import Status | Imported |
| Model | CheckPoint |
| Instrument Type | Online TOC Analyzer |
| Measurement Principle | Direct Conductivity Detection |
| Oxidation Method | UV Photolysis |
| Measurement Range | 0.21–1000 ppb C |
| Accuracy | ±5% |
| Resolution | 0.01 ppb C |
| Detection Limit | 0.21 ppb C |
| Repeatability | RSD < 1% |
| Analysis Time (Online Mode) | 15 s – 8 h (configurable) |
| Analysis Time (Grab Sample Mode) | 10 min |
| Calibration Interval | 6 months |
| Data Storage Capacity | 28,800 records |
| Connectivity | Ethernet, Modbus RTU/TCP |
| Compliance Support | IQ/OQ/PQ protocols available |
| Regulatory Context | Designed for compliance with USP <643>, EP 2.2.44, ASTM D5905, and FDA 21 CFR Part 11-ready data integrity architecture |
| Brand | Sievers/Veolia |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | CheckPoint |
| Pricing | Available Upon Request |
| Detection Range | 0.05–1,000 ppb C |
| Precision | Greater of <1% RSD or 0.05 ppb (online, 20–40 °C) |
| Analysis Modes | Online continuous averaging, online timed sampling, offline grab sampling |
| Analysis Time | 15 s (online), 10 min (grab) |
| TOC Calibration Interval | 6 months |
| Conductivity Tolerance | Up to 1.4 µS/cm (0.7 MΩ·cm) CO₂-compensated conductivity |
| Conductivity Precision | ±0.5% RSD (20–40 °C) |
| Conductivity Accuracy | ±2.0% |
| Conductivity Calibration Interval | 6 months |
| Operating Pressure (Online) | 15–100 psi |
| Low-Pressure Sampling | Max. 0.70 m head above analyzer |
| Minimum Online Flow Rate | >60 mL/min |
| Power Supply | 100–240 V ±10%, 60 W, 50/60 Hz |
| Sample Temperature Range | 10–90 °C |
| Ambient Operating Temperature | 10–40 °C |
| Enclosure Rating | Indoor use only |
| I/O Options | Ethernet, 2 analog outputs, 2 alarm outputs, parallel inputs |
| Installation Category | Overvoltage Category II |
| Dimensions (H×W×D) | 25.4 × 30.48 × 15.24 cm (standard) |
| Weight | 2.9 kg (no battery), 3.58 kg (with battery), +0.6 kg (vial sampler) |
| Safety Certifications | CE, ETL Listed |
| Brand | Sievers (Veolia) |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Import Status | Imported |
| Model | Sievers Eclipse |
| Pricing | Available Upon Request |
| Brand | Sievers (Veolia) |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | Sievers InnovOx Lab |
| Instrument Type | Laboratory TOC Analyzer |
| Detection Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Oxidation Method | Supercritical Water Oxidation (SCWO) |
| Measurement Range | 0.05 ppm – 50,000 ppm TOC |
| Accuracy | ±3% |
| Resolution | 0.05 ppm |
| Detection Limit | 0.05 ppm |
| Repeatability | RSD ≤ 1.5% |
| Brand | Sievers (Veolia) |
|---|---|
| Origin | USA |
| Model | InnovOx Laboratory |
| Instrument Type | Laboratory TOC Analyzer |
| Detection Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Oxidation Method | Supercritical Water Oxidation (SCWO) |
| Measurement Range | 0.05–50,000 ppm TOC |
| Accuracy | ±3% |
| Resolution | 0.01 ppm |
| Detection Limit | 0.05 ppm |
| Repeatability | ±3% |
| Regulatory Compliance | US EPA Methods 415.1, 415.3, 9060A |
| Brand | Sievers (Veolia) |
|---|---|
| Origin | USA |
| Model | InnovOx |
| Detection Range | 0.05–50,000 ppm TOC |
| LOD | 0.05 ppm TOC |
| Accuracy | ±3% at 50 mg/L NPOC |
| Precision | RSD <5% at 50 mg/L NPOC |
| Linearity | R² >0.995 |
| Analysis Time | 2.2–7.3 min |
| Calibration Stability | 6 months |
| Particle Tolerance | <800 µm |
| Operating Temp | 10–40 °C |
| Sample Temp | 10–60 °C |
| Humidity | ≤95% RH (non-condensing) |
| Power | 100–240 VAC ±10%, 400 W, 50/60 Hz |
| Dimensions | 52.05 × 32.26 × 58.42 cm |
| Weight | 22.4 kg |
| Interface | Ethernet + 3 USB ports |
| Display | Color touchscreen |
| Brand | Sievers (Veolia) |
|---|---|
| Origin | USA |
| Model | Sievers M500 |
| Instrument Type | Online TOC Analyzer |
| Detection Principle | Membrane Conductivity Detection |
| Oxidation Method | UV Oxidation |
| Measurement Range | 0.03–2500 ppb |
| Accuracy | ±5% of reading or ±0.01 ppb (whichever is greater) |
| Resolution | 0.03 ppb |
| Detection Limit | 0.03 ppb |
| Repeatability | ±5% of reading or ±0.01 ppb (whichever is greater) |
| Analysis Time (Continuous Mode) | 6 minutes |
| Sample Flow Rate | 0.25 mL/min |
| External Flow Rate | 50 mL/min |
| Sample Temperature Range | 1–95 °C (steam-tolerant for short-term exposure) |
| Max. Inlet Pressure | 100 psi |
| Conductivity Tolerance | 0.01–800 µS/cm |
| Calibration Stability | Up to 12 months without recalibration |
| Display | 10-inch color touchscreen |
| Enclosure Rating | IP55 |
| Power Supply | 100–240 VAC (+10%), 50/60 Hz, 50 W |
| Operating Environment | Indoor use only |
| Safety Certifications | ETL, CE |
| Dimensions (H×W×D) | 43.4 × 55.9 × 28.7 cm |
| Weight | 16.3 kg |
| Brand | Sievers (Veolia) |
|---|---|
| Origin | USA |
| Model | M5310C |
| Instrument Type | Laboratory TOC Analyzer |
| Detection Principle | Membrane Conductivity Detection |
| Oxidation Method | UV/Persulfate Oxidation |
| Measurement Range | 4 ppb – 50 ppm |
| Accuracy | ±2% or ±0.5 ppb (whichever is greater) |
| Resolution | 0.01 ppb |
| Detection Limit | 4 ppb |
| Repeatability | ≤1% RSD |
| Analysis Time | 2 minutes |
| Calibration Interval | 12 months |
| Regulatory Compliance | US EPA Method 415.3 & Standard Methods 5310 C |
| Brand | Sievers (Veolia) |
|---|---|
| Origin | USA |
| Model | M5310C Online |
| Detection Principle | Membrane Conductivity Detection |
| Oxidation Method | UV/Persulfate |
| Measurement Range | 4 ppb – 50 ppm |
| Accuracy | ±2% or ±0.5 ppb (whichever is greater) |
| Resolution | 0.01 ppb |
| Detection Limit | 4 ppb |
| Repeatability | ≤1% RSD |
| Analysis Time | 2 minutes |
| Calibration Interval | 12 months |
| Compliance | US EPA Method 415.3 & Standard Methods 5310 C |
| Instrument Type | Online TOC Analyzer |
| Brand | Sievers (Veolia) |
|---|---|
| Origin | USA |
| Model | M5310C Portable |
| Detection Principle | Membrane Conductivity Detection |
| Oxidation Method | UV/Persulfate |
| Measurement Range | 4 ppb – 50 ppm |
| Accuracy | ±2% or ±0.5 ppb (whichever is greater) |
| Resolution | 0.01 ppb |
| Detection Limit | 4 ppb |
| Repeatability | ≤1% RSD |
| Analysis Time | 2 minutes |
| Calibration Interval | 12 months |
| Compliance | US EPA Method 415.3 & Standard Methods 5310 C |
| Brand | Sievers (Veolia) |
|---|---|
| Origin | USA |
| Model | M9 Laboratory |
| Detection Principle | Membrane Conductivity Detection |
| Oxidation Method | UV/Persulfate Oxidation |
| Measurement Range | 0.03 ppb – 50 ppm |
| Accuracy | ±2% or ±0.5 ppb (whichever is greater) |
| Resolution | 0.01 ppb |
| Detection Limit | 0.03 ppb |
| Repeatability | ≤1% RSD |
| Analysis Time | 2 minutes |
| Calibration Interval | 12 months |
| Communication Interfaces | USB, 4–20 mA, Modbus TCP/IP |
| Enclosure Rating | Dust- and Splash-Resistant (for online/portable variants) |
| Design | Modular, Touchscreen Dashboard, Reagent-Free Operation (no external gases or hazardous chemicals required) |
| Brand | Sievers (Veolia) |
|---|---|
| Origin | USA |
| Model | M9 Online |
| Instrument Type | Online TOC Analyzer |
| Detection Principle | Membrane Conductivity Detection |
| Oxidation Method | UV/Persulfate Oxidation |
| Measurement Range | 0.03 ppb – 50 ppm |
| Accuracy | ±2% or ±0.5 ppb (whichever is greater) |
| Resolution | 0.01 ppb |
| Detection Limit | 0.03 ppb |
| Repeatability | ≤1% RSD |
| Analysis Time | 2 minutes |
| Calibration Interval | 12 months |
| Enclosure Rating | IP54 (Dust- and Splash-Resistant) |
| Communication Interfaces | USB, 4–20 mA, Modbus TCP/IP |
| Regulatory Compliance Support | USP <643>, EP 2.2.44, ASTM D5903, ISO 8245, FDA 21 CFR Part 11 (audit trail & electronic signature ready), GLP/GMP data integrity architecture |
| Brand | Sievers (Veolia) |
|---|---|
| Origin | USA |
| Model | Sievers M9 Portable Analyzer |
| Instrument Type | Portable TOC Analyzer |
| Detection Principle | Membrane Conductivity Detection |
| Oxidation Method | UV/Persulfate Oxidation |
| Measurement Range | 0.03 ppb – 50 ppm |
| Accuracy | ±2% or ±0.5 ppb (whichever is greater) |
| Resolution | 0.01 ppb |
| Detection Limit | 0.03 ppb |
| Repeatability | RSD < 1% |
| Analysis Time | 2 minutes |
| Calibration Interval | 12 months |
| Data Interfaces | USB, 4–20 mA, Modbus TCP/IP |
| Enclosure Rating | Dust- and splash-resistant |
| Regulatory Compliance | Designed for USP <643>, EP 2.2.44, ASTM D7573, ISO 8245, and FDA 21 CFR Part 11–ready data integrity workflows |
| Brand | Sievers (Veolia) |
|---|---|
| Origin | USA |
| Model | Sievers M9 SEC Portable |
| Instrument Type | Portable TOC Analyzer |
| Detection Principle | Membrane Conductivity Detection |
| Oxidation Method | UV/Persulfate Oxidation |
| Measurement Range | 0.03 ppb – 50 ppm |
| Accuracy | ±2% |
| Resolution | 0.01 ppb |
| Detection Limit | 0.03 ppb |
| Repeatability | ≤1% RSD |
| Brand | Sievers/Veolia |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | PURELAB Flex |
| Pricing | Available Upon Request |
| Brand | Sievers (Veolia) |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | SIEVERS SOLEIL |
| Instrument Type | Fully Automated Microbial Enumeration System |
| Detection Range | 1–10,000 biotics per 100 mL |
| Sample Aspiration Rate | 8 mL/min |
| Dimensions (W×D×H, without laptop) | 48.3 cm × 43.2 cm × 43.2 cm (19 in × 17 in × 17 in) |