Thermo Fisher Scientific
Filter
Showing 391–409 of 409 results
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Vari Mix Tilt |
| Pricing | Available Upon Request |
| Oscillation Angle Range | 1–48° from Horizontal |
| Speed Range | 5–30 rpm |
| Max Load Capacity | 6.8 kg |
| Platform Dimensions | 27 × 32 cm |
| External Dimensions | 39.6 × 18.5 × 30.4 cm |
| Power Supply | 220–240 V, 50/60 Hz |
| Operating Temperature | 4–40 °C |
| Operating Humidity | 20–65 % RH |
| Net Weight | 2.7 kg |
| Product Code | M79730-33CN |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic (China-manufactured) |
| Model | Varioskan ALF Multimode Microplate Reader |
| Price | Upon Request |
| Absorbance Range | 200–1000 nm |
| Absorbance Accuracy | ±1.0% + 0.003 Abs (0–2.0 Abs), ±2.0% (2.0–2.5 Abs) at 450 nm (96-well plate) |
| Photometric Bandwidth | 2.5 nm |
| Excitation Wavelength Range | 200–710 nm |
| Emission Wavelength Range | 210–720 nm |
| Fluorometry & Luminometry Dynamic Range | ≥6 decades |
| Filter Configuration | 3 pre-installed fluorometric filter pairs + 5 open filter positions |
| Detector Type | Photomultiplier Tube (PMT) |
| Light Source | Xenon Flash Lamp |
| Plate Compatibility | 6- to 384-well microplates, μDrop and μDrop Duo plates |
| Onboard Incubation Range | Ambient +2°C to 45°C |
| Shaking Modes | Linear, Orbital, Double Orbital |
| Measurement Modes | Endpoint, Kinetic, Spectral Scan |
| Photometric Read Time (Fast Mode) | ≤10 sec (96-well) |
| Fluorometric/Luminometric Read Time | ≤20 sec (96-well) |
| Sensitivity (Fluorescein) | 0.35 fmol/well (black 384-well plate) |
| (ATP Luminescence) | <275 amol/well (white 96-well plate) |
| (DNA Absorbance) | <1 ng/μL (96-well half-area plate) |
| (Turbidity) | <5 FTU (96-well plate) |
| Linearity | 0–2.5 Abs, ±2.0% at 450 nm (96-well plate) |
| Precision | SD <0.003 Abs or CV <1.0% at 450 nm |
| Dimensions (L × W × H) | 61 × 34 × 40 cm |
| Weight | 24.5 kg |
| Power Supply | 100/115/220/230 V |
| Software | Thermo Scientific SkanIt Software (Research Edition & Drug Discovery Edition), multi-language support (EN, FR, DE, ES, PT, IT, JA, ZH), unlimited installations, no annual license fee |
| Compliance Support | 21 CFR Part 11 (Drug Discovery Edition), GLP/GMP-ready audit trail, electronic signature, user access control |
| Validation Tools | Thermo Scientific Verification Plates (traceable optical performance validation) |
| Warranty | 1-year standard + optional 2-year Rapid Exchange Extended Warranty (Cat. No. A66711) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Imported |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | Volumescope 2 |
| Instrument Type | Floor-standing SEM |
| Electron Source | Cold Field Emission Gun (CFEG) |
| Accelerating Voltage | 1.0–30 kV |
| Vacuum Modes | High Vacuum (HiVac) and Low Vacuum (LoVac) with VSDBS detector |
| Z-axis Optical Sectioning Resolution | Up to 10 nm |
| Sample Handling | Automated ultramicrotome integration for seamless transition between conventional SEM and SBFI/AT workflows |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Vortex Mixer |
| Model | Thermo Scientific Vortex Mixer |
| Speed Range | 0–3000 rpm |
| Operating Mode | Continuous or Pulse Mixing |
| Safety Feature | Built-in Overcurrent Protection |
| Design | Low-profile, Space-saving Footprint |
| Platform | Single-plate Fixed Platform |
| Power Supply | Standard AC Input (100–240 V, 50/60 Hz) |
| Compliance | CE, UL Listed |
| Certifications | ISO 9001 Manufacturing Environment |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | South Korea |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Life Science Instrument |
| Model | Thermo Scientific WaveMaster Optical-Sensing 3D Orbital Shaker |
| Timing Range | 1 min – 99 hrs 59 min or Continuous Operation |
| Oscillation Speed | 8–100 rpm |
| Tilt Angle Adjustment | 0°–13° |
| Temperature Compatibility | Up to 60°C (non-CO₂ incubators only) |
| Platform Count | 1 |
| Standard Accessories | Universal platform, anti-slip silicone mat, two elastic retaining rings |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Line | Domestic Production |
| Models | Wellwash, Wellwash Versa |
| Instrument Type | Dedicated Microplate Washer |
| Wash Head Configurations | 1×8 and 1×12 (Wellwash) |
| Wash Head Design | Single (Wellwash) |
| Fluid Channels | 1 wash channel + 1 waste channel (Wellwash) |
| Soak Time Range | 0–60 min |
| Wash Cycles | 1–10 |
| Residual Volume per Well | <1.5 µL |
| Plate Shaking | Linear oscillation with low/medium/high intensity adjustment |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | Wellwash |
| Instrument Type | Multifunctional Microplate Washer |
| Wash Head Configuration | 8-channel or 12-channel |
| Rinse Head Design | Single |
| Wash Solution Channels | 1 |
| Soak Time Range | 0–10 min |
| Wash Cycles | 1 |
| Residual Volume per Well | <1.5 µL |
| Plate Shaking Function | Yes |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Category | Imported Instrument |
| Model | Wellwash Versa |
| Pricing | Upon Request |
| Wash Fluid Channels | Up to 3 |
| Bottle Configuration | Two 2-L wash bottles, one 2-L rinse bottle, one 4-L waste bottle |
| Wash Heads | 1×8, 1×12, 2×8, 2×12, 1×16, plus dedicated 1×8 and 2×8 cell wash heads |
| Compatible Plate Formats | 96-well and 384-well microplates |
| Wash Volume Range | 50–1000 µL (96-well), 20–300 µL (384-well) |
| Pre-wash Volume | 5–100 mL |
| Rinse Volume | 5–100 mL |
| Dispense Volume | 50–400 µL (96-well), 20–120 µL (384-well) |
| Residual Liquid Volume | <1.5 µL per well |
| Data Interface | USB port, RS-232C for automation integration |
| Dimensions (H×W×D) | 345 × 385 × 240 mm (13.6 × 15.2 × 9.4 in) |
| Weight | 9 kg (20 lbs) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Classification | Domestically Produced |
| Model | Thermo Scientific™ 1500 Series Biological Safety Cabinet (Domestically Manufactured in Shanghai) |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher Scientific |
|---|---|
| Model | 1500 Series |
| Certification | NSF/ANSI 49-2022 |
| Airflow Type | Recirculating (70% re-circulated, 30% exhausted) |
| Work Area Dimensions (W×D×H) | 1524 × 610 × 610 mm |
| Max. Sash Height | 200 mm |
| Average Inflow Velocity | ≥0.50 m/s |
| Average Downflow Velocity | ≥0.25 m/s |
| Noise Level | ≤65 dBA |
| Illumination | ≥650 lux at work surface |
| UV Lamp | Programmable, 254 nm low-pressure mercury lamp |
| Display | 7-inch capacitive touchscreen GUI |
| SmartFlow Plus | Real-time airflow monitoring with automatic fan speed adjustment |
| SmartClean Front Window Mechanism | Patented dual-gear positioning system |
| SmartPort Side Access Ports | Dual-side cable and tubing pass-throughs |
| Energy Mode | Automatic fan speed reduction when sash is fully closed |
| Mobility Option | Fixed-height stand with locking casters |
| Compliance | Designed and validated per NSF/ANSI 49-2022, suitable for GLP/GMP environments requiring documented airflow integrity and audit-ready operation |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Category | Imported Instrument |
| Model | 371 |
| Temperature Control Range & Accuracy | 5–50 °C (±0.1 °C typical setpoint stability) |
| Temperature Uniformity | ±0.3 °C at 37 °C (at working volume, per ISO 13845:2017 Annex B) |
| Humidity Control Range & Accuracy | 5–50 % RH (±2 % RH, non-condensing, with optional humidification system) |
| Chamber Capacity | 184.1 L |
| Sterilization Method | Dry-heat cycle (180 °C for ≥3 h), validated per ISO 14937 and EN 556-1 |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Floor-standing centrifuge |
| Speed Range | Up to 5,400 rpm |
| RCF Max | 8,500 × g |
| Capacity | 16 L (max) |
| Rotor Configuration | Horizontal (swing-out) |
| Application Class | Cell & bacterial separation |
| Dimensions (H×W×D) | 1,015 × 816 × 990 mm |
| Cooling System | GreenCool™ CO₂-based refrigeration |
| Door Mechanism | Auto-Door™ with motorized full-open/full-close actuation |
| Lid Handling | Auto-Lid™ integrated rotor lid storage and synchronized operation |
| User Interface | Centri-Touch™ capacitive touchscreen with glove-compatible operation |
| Rotor Recognition | Auto-ID™ real-time rotor identification |
| Drive System | DuraFlex™ active imbalance compensation (up to 125 g) |
| Acceleration Profiles | 11 selectable |
| Deceleration Profiles | 12 selectable |
| Compliance | Designed for GLP/GMP environments |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Shanghai, China |
| Model | Thermo Scientific™ CryoExtra™ High-Efficiency Liquid Nitrogen Storage Tank |
| Capacity | 1770 L (62.5 cu. ft.) |
| Internal Height | 86.9 cm (34.2 in) |
| Internal Depth | 162.1 cm (63.8 in) |
| External Height | 203.2 cm (80 in) |
| Diameter | 152.4 cm (60 in) |
| Neck Inner Diameter | 63.5 cm (25 in) |
| Sample Capacity | 93,000 × 2 mL vials |
| Temperature Monitoring | Microprocessor-based LN₂ level & temperature control with audible/visual alarm |
| Power Requirement | 100–230 V, 50/60 Hz |
| Certifications | CE, UL Listed |
| Construction | Stainless steel cryogenic chamber |
| Door Quantity | 1 |
| Transport Weight | 1123 kg (2470 lb) |
| Net Weight | 781 kg (1721 lb) |
| Accessories | 0.5″ 45° flared inlet port, 1.8 m stainless steel flexible LN₂ hose included |
| LN₂ Supply Requirement | 22 psi low-pressure supply tank (sold separately) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China-manufactured) |
| Model | Thermo Scientific™ CryoMed™ CTS Series Controlled-Rate Freezer |
| Quotation | Upon Request |
| Capacity | 48 L (1.7 ft³) |
| Temperature Range | −180 °C to +50 °C |
| Chamber Material | 304 Stainless Steel with Powder-Coated Exterior |
| Certifications | CE Compliant |
| Data Interface | OPC UA (Ethernet), USB 2.0 |
| Onboard Data Logging | Yes |
| Regulatory Compliance | FDA 21 CFR Part 11, GMP-aligned |
| User Access Levels | 3-Tier Authentication |
| Predefined Programs | 6 Factory-Loaded |
| Custom Programs | Up to 14 User-Defined |
| Cooling Medium | Liquid Nitrogen (LN₂) |
| Dual Solenoid Valve Control | Yes |
| VHP-Compatible | Yes |
| Thermal Monitoring | Dual T-type Thermocouples (Chamber + Sample) |
| Alarm System | Real-time Fault Detection (Thermocouple, Heater, Temp Limit, Power Loss, Run Completion) |
| Remote Alert Contacts | Optional |
| Printer Support | Optional Thermal Printer |
| Dimensions (W×D×H) | 125.2 × 61 × 55.1 cm |
| Net Weight | 86.6 kg (191 lb) |
| Electrical Supply | 220–230 V, 50–60 Hz, 12 A |
| Plug Type | CEE 7/7 |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Benchtop Incubation Water Bath |
| Model | COL19 / COL35 |
| Bath Capacity | 19 L / 35 L |
| Temperature Range | 5–100 °C (factory-preset incubation setpoints at 35.0 °C, 41.5 °C, 44.5 °C, and 45.5 °C) |
| Temperature Stability | ±0.1 °C (uniformity ±0.05 °C at 70 °C) |
| Power Rating | 1200 W (COL19), 1500 W (COL35) |
| Compliance | UL 61010-1, CE Marked |
| Chamber Dimensions (L×W×H) | 305 × 387 × 192 mm (COL19), 305 × 692 × 192 mm (COL35) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | Thermo Scientific™ Precision™ General-Purpose Water Bath |
| Quotation | Upon Request |
| Temperature Range | Ambient to 90°C |
| Temperature Accuracy | ±0.1°C |
| Heating Power | 200 W |
| Dimensions (W×D×H) | 9.1 × 7.8 × 9.2 in. (230 × 199 × 233 mm) |
| Capacity | 2 L |
| Chamber Material | Seamless Stainless Steel |
| Exterior Finish | Epoxy Powder-Coated Steel |
| Controller | Microprocessor-Based Digital Display |
| Display | Monochrome LCD with Icon-Based Interface |
| Preset Temperature Settings | 4 |
| Temperature Uniformity | ±0.2°C |
| Low-Level Protection | Yes |
| Safety Features | Over-Temperature Cut-Off Circuit, Auto-On/Auto-Off Timer |
| Accessories Included | Transparent Polycarbonate Lid with Rubber Duck Seal |
| Certifications | UL, CE |
| Electrical Requirements | 120/230 V, 50/60 Hz |
| Current Draw | 1.5–1.8 A (120 V) / 0.7–0.9 A (230 V) |
| Warranty | Region-Specific — Contact Local Support |
| Regulatory Note | Not intended for IVD/MD use in certain jurisdictions |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Thermo Scientific™ Stellar™ |
| Instrument Type | Hybrid Triple Quadrupole–Ion Trap (QqQ-IT) |
| Application Scope | Universal (Small Molecules, Peptides, Post-Translational Modifications, Lipids, Metabolites) |
| Mass Range | Full Scan Mode: m/z 5–2000 |
| MSⁿ Mode | m/z 20–2000 |
| Sensitivity | Targeted MS² (HESI+, SRM/MRM) |
| Resolution | Quadrupole Isolation Width: 0.4 Th |
| Ion Trap Peak Width (Dependent on Scan Rate) | 0.50 Da at 33 kDa/s, 0.60 Da at 67 kDa/s, 0.80 Da at 125 kDa/s, 2.00 Da at 200 kDa/s |
| Mass Accuracy | ≤ ±0.1 Da for m/z 524 over 24 h at 33 kDa/s scan rate |
| Gas Supply Pressure | Sheath/Auxiliary/Sweep Gas: 690 ± 140 kPa (100 ± 20 psig) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestically Produced |
| Model | Thermo Scientific™ STP Series Ultra-Low Temperature Freezer (Domestically Manufactured) |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Manufactured in China (for global distribution) |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Cooling Method | Dual-mode — Direct-contact conduction + Forced-air circulation |
| Refrigeration Technology | Solid-state thermoelectric heat pump with variable-frequency STeM drive |
| Temperature Range | +3 °C to +7 °C |
| Temperature Uniformity | ≤ ±1 °C (at 4 °C setpoint, steady-state, 3-point validation) |
| Net Capacity | 156 L |
| Internal Dimensions (W×D×H) | 584 × 495 × 520 mm |
| External Dimensions (W×D×H) | 810 × 600 × 660 mm |
| Noise Level | ≤ 32 dB(A) |
| Energy Reduction vs. Conventional Compressor Units | 37% |