Thermo Fisher Scientific
Filter
Showing 331–360 of 409 results
| Brand | Thermo Fisher Scientific |
|---|---|
| Model | Multiskan FC & Varioskan ALF |
| Detection Modes | Absorbance, Fluorescence (including FRET), Luminescence (including FRET) |
| Wavelength Range | 340–850 nm (Multiskan FC) |
| Plate Formats | 6–384-well microplates, including UV-transparent and ultra-low-volume plates |
| Incubation Temperature | Up to 50 °C |
| Built-in Shaking | Yes |
| Onboard Software | Thermo Scientific SkanIt PC Software (FDA 21 CFR Part 11 compliant with audit trail, user roles, and electronic signature support) |
| Regulatory Compliance | IVD CE-marked (Multiskan FC IVD variant), ISO 13485-aligned design, GLP/GMP-ready workflows |
| Connectivity | USB 2.0, optional Ethernet |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | FC |
| Detection Method | Absorbance (Photometric) |
| Functionality | Single-mode |
| Automation Level | Semi-automated |
| Measurement Mode | Endpoint Scanning |
| Curve Fitting | Polynomial, Linear, Log-Log, 4-Parameter Logistic (4PL), and Other Standard Functions |
| Detector Type | UV-Visible Photodiode Array |
| Wavelength Range | 340–850 nm |
| Absorbance Range | 0–6 ABS |
| Linear Range | 0–3 ABS (at 405 nm, 96-well, standard mode) |
| Wavelength Selection Speed | 6 s per wavelength (96-well plate, fast mode) |
| Accuracy | ±1% (0–3 ABS), ±2% (3–4 ABS) at 405 nm |
| Precision (CV) | ≤0.2% (0–3 ABS), ≤1.0% (3–4 ABS), standard mode |
| Optical Resolution | 0.001 ABS |
| Filter Wheel | 8-position, standard filters: 405 nm, 450 nm, 620 nm |
| optional filters available (FWHM | 3–9 nm) |
| Plate Formats | 96-well and 384-well microplates |
| Incubation (optional) | RT +4°C to 50°C |
| Shaking | Linear shaking with three speed settings |
| Display | 480 × 272 pixel color LCD touchscreen |
| Onboard Memory | 100 protocols + 100 result sets (96-well) |
| Interfaces | 3× USB (PC, printer, USB storage) |
| Compliance | RoHS, CE (2002/96/EC), FCC Part 15 Subpart B Class B, IEC 61010-1 |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA (assembled in Shanghai) |
| Model | MK3 |
| Function Type | Multifunctional |
| Automation Level | Semi-Automatic |
| Measurement Method | Scanning |
| Curve Fitting | Mathematical Functions |
| Detector Type | UV-Vis Photomultiplier Tube (PMT) |
| Wavelength Range | 340–850 nm |
| Absorbance Range | 0–4.0 ABS |
| Linearity Range | 0–2.0 ABS |
| Wavelength Switching Time | 6 s |
| Photometric Accuracy | ±1% (0–2.0 ABS) |
| Precision (CV) | <0.5% (0–1.5 ABS) |
| Resolution | 0.001 ABS |
| Plate Read Time | ≤5 s per 96-well plate |
| Optical System | Multi-channel fiber-optic detection |
| Filter Capacity | Up to 8 positions, motorized filter wheel |
| Built-in Shaker | Linear, 3 adjustable speeds |
| Dimensions | 140 × 420 × 320 mm |
| Weight | 11 kg |
| Power Supply | 220–240 V, 50/60 Hz |
| Light Source | Tungsten-halogen lamp with spare bulb included |
| Interface | RS-232 serial port, parallel printer port |
| Onboard Display | 2 × 20 character LCD |
| Keyboard | 30-key tactile membrane keypad |
| Data Storage | 64 programmable protocols and calibration curves |
| Software | Windows-based MK3 Control & Analysis Suite (included) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | NanoDrop Eight Ultra Micro Spectrophotometer |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Line | Nanopure Series |
| Flow Rate | >1.6 L/min |
| Resistivity | >18.2 MΩ·cm |
| Total Organic Carbon (TOC) | <5 ppb |
| Endotoxin | <0.001 EU/mL |
| Particles (>0.2 µm) | <1 particle/mL |
| UV Absorbance (254 nm) | <0.0001 AU |
| Silica | <3 ppb |
| Conductivity Calibration Option | NIST-traceable module available |
| Compliance | ASTM D1193 Type I, NCCLS (now CLSI) EP21-A, CAP guidelines |
| Certifications | CSA, CE |
| Power Input | 90–240 VAC, 47–63 Hz |
| Interface | RS-232 for data logging and printer/computer connectivity |
| Remote Display | Optional wall-mount or under-bench installation supported |
| Real-time TOC monitoring | Standard |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestically Manufactured |
| Model | NextGuard X-Ray Inspection System (Domestically Manufactured) |
| Pricing | Available Upon Request |
| Radiation Compliance | FDA 21 CFR Part 1020.40, RED Regulations (Canada), CE Marking (EU) |
| Conveyor Height Options | 800 / 950 / 1100 mm (±75 mm) |
| Max Conveyor Length | 1.5 m standard, extendable up to +1.0 m (in 200 mm increments) |
| Max Product Weight | 11 kg (25 lbs) |
| Detector Pixel Size (Optional) | 0.4 mm |
| Processor Speed | 6× faster than 1st-generation NextGuard |
| Detector Resolution Gain (Optional) | 3.2× improvement vs. baseline |
| Software Modules | Product Verification, Density-Based Contaminant Detection, VersaWeigh™ Mass Estimation, Dual-Rejection Logic |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestically Manufactured |
| Model | Nicolet Summit X FTIR Spectrometer (Domestically Manufactured) |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Niton XL2 Handheld EDXRF Spectrometer |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Type | Imported |
| Model | XL3t 500 |
| Form Factor | Handheld / Portable |
| Detector Options | Si-PIN or High-Performance SDD with Peltier cooling |
| Excitation Source | Rhodium or Silver anode micro-X-ray tube (50 kV / 40 µA max) |
| Analyzable Elements | Mg–U (with He purge: Mg, Al, Si, P, S, Cl, K, Ca, and beyond) |
| Measurement Window | 8 mm or 3 mm (optional) |
| Display | Adjustable-angle VGA color touchscreen (0–90°) |
| Dimensions | 95.5 × 244 × 230 mm |
| Weight | <1.3 kg |
| Battery Life | Up to 10 hours (hot-swappable Li-ion with thermal management) |
| Data Storage | >10,000 spectra + results |
| Connectivity | USB, Bluetooth, RS-232 |
| Calibration Methods | Fundamental Parameters (FP) and empirical coefficient algorithms |
| Compliance | Meets IEC 61000-4 electromagnetic immunity standards |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Niton XL3t Handheld ED-XRF Spectrometer |
| Price | Upon Request |
| Detector Type | High-Performance Silicon Drift Detector (SDD) |
| X-ray Tube | Au anode, 50 kV max, 200 µA max |
| Minimum Detection Limits | Sub-ppm for high-Z elements |
| Elemental Range | S (16) to U (92) — up to 25 elements simultaneously quantified |
| Standard Spot Size | 3 mm collimated beam |
| Display | Tilting full-color capacitive touchscreen (4.3″) |
| Operating Temperature | –10 °C to 50 °C |
| Hot Surface Capability | Up to 450 °C (842 °F) with HotFoot™ adapter |
| Data Connectivity | Integrated USB 2.0, Bluetooth 4.0, RS-232 |
| Software | Thermo Scientific Niton Data Transfer (NDT™) v9.x with user permission management, audit trail, CFR Part 11-compliant reporting options |
| Dimensions (L × W × H) | 244 × 230 × 95.5 mm |
| Weight | 1.3 kg |
| Power | Dual hot-swappable Li-ion battery packs (4-cell or optional 6-cell), 100 µA typical operating current |
| Compliance | CE, RoHS 2011/65/EU, IEC 62471, FDA 21 CFR Part 1020.40, ISO 12885, ASTM E1621–22, ASTM E2857–22 |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Type | Imported |
| Model | XL3t600 |
| Form Factor | Handheld / Portable |
| Excitation Source | High-Performance Microfocus X-ray Tube (Au anode) |
| Detector | High-Resolution Si-PIN Detector |
| Display | Adjustable 0–90° VGA Color Touchscreen |
| Battery | Third-Generation Hot-Swappable Rechargeable Li-ion |
| Analyzable Elements | Mg to U (depending on configuration) |
| Standard Mode | Soil Analysis Mode |
| Data Storage | >10,000 spectra + results |
| Connectivity | USB, Bluetooth 4.0, RS-232 |
| Safety | Password-Protected Access & Beam Interlock |
| Compliance | Meets EPA Method 6200 requirements for field screening |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | XL3t700 |
| Portability | Handheld / Field-Deployable |
| Weight | <1.3 kg |
| Dimensions | 244 × 230 × 95.5 mm (9.60 × 9.05 × 3.75 in) |
| X-ray Tube | High-performance micro-focus tube with Au anode (max 50 kV / 40 µA) |
| Detector | High-resolution Si-PIN semiconductor detector |
| Battery | Rechargeable Li-ion, >10 h operation per charge |
| Display | Adjustable-angle VGA color touchscreen (0–90° tilt) |
| Standard Elemental Range | Ti–U |
| Optional Helium Purge Kit | Enables Mg, Al, Si, P, S, Ru detection |
| Data Storage | >10,000 spectra + metadata entries |
| Operating Modes | Metal, Plastic, Auto, Paint/Coating |
| Connectivity | USB 2.0, Bluetooth 4.0 |
| Software | NITON Data Transfer (NDT) v4.x with audit trail, user permissions, report customization, remote instrument control, and over-the-air firmware updates |
| Regulatory Compliance | Fully compliant with ASTM F2853, ASTM E1621, ISO 17025 (when used in accredited labs), CPSC Guidance for CPSIA Section 101, EU RoHS Directive 2011/65/EU Annex II, EN 71-3:2019, WEEE Directive 2012/19/EU |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Handheld EDXRF Analyzer |
| Model | Thermo Scientific Niton XL5 |
| Element Range | Mg (12) to U (92) |
| Detectable Elements | >30 common elements for alloy identification |
| Light Element Performance | Enhanced detection of low-Z elements (e.g., Mg, Al, Si, P, S) |
| Energy Resolution | 150–185 eV (FWHM, dependent on pulse processing time) |
| Weight | 1.3 kg (2.8 lbs) with battery |
| Dimensions | 242.6 × 208.2 × 67.9 mm (9.54 × 8.19 × 2.67 in) |
| X-ray Tube | Ag anode, 6–50 kV, up to 500 µA, max 5 W, dynamically adjustable current |
| Detector | Geometry-optimized large-area Silicon Drift Detector (GOLDD™), count rate up to 180,000 cps |
| Electronics | 800 MHz i.MX6 Quad-core ARM A9, 80 MHz ADC ASIC, 4096-channel MCA, 512 MB RAM / 4 GB industrial-grade flash storage |
| Display | Tilt-adjustable color touchscreen (glove-compatible) |
| Data Storage | >20,000 spectra (2 GB internal, ~100 kB/spectrum) |
| Connectivity | USB 2.0, Bluetooth 4.2, integrated GPS |
| Software | NitonConnect PC software, user-programmable menus, alloy mode with touch keyboard |
| Standard Accessories | Integrated CCD camera, rugged carrying case, dual Li-ion batteries, AC charger, USB cable, safety lanyard, calibration standards |
| Optional Accessories | 3-mm collimator, portable test stand, HotFoot thermal barrier, protective holster |
| Certifications | CE, RoHS, FCC, Industry Canada, IEC 61010-1:2010 |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | South Korea |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Thermo Scientific Orbital Shaker with Photoelectric Speed Control |
| Price Range | USD 700–1,400 (FOB) |
| Instrument Type | General-Purpose Orbital Shaker |
| Timer Range | 1 min to 99 hrs 59 min or Continuous Operation |
| Oscillation Speed | 5–100 rpm |
| Tilt Angle | 7°–13° |
| Maximum Operating Temperature | ≤60 °C |
| Platform Count | 1 |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | Thermo Scientific Orion 2210AM |
| Instrument Type | Online Analyzer |
| Measurement Principle | Colorimetric Method (Indophenol Blue) |
| Measurement Ranges | 0.01–2 mg/L, 0.05–10 mg/L, 0.5–50 mg/L, 5–500 mg/L (as N) |
| Accuracy | ±5% or ±0.01 mg/L (whichever is greater) within 0.01–50 mg/L |
| Detection Limit | 0.01 mg/L (as N) |
| Analysis Time | ≤30 minutes per cycle |
| Temperature Control | Integrated thermostatically controlled cuvette with magnetic stirring |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Thermo Scientific Orion 2210AM |
| Instrument Type | Online Analyzer |
| Measurement Principle | Colorimetric Method (Indophenol Blue Reaction) |
| Measurement Ranges | 0.01–2 mg/L, 0.05–10 mg/L, 0.5–50 mg/L, 5–500 mg/L (as N) |
| Accuracy | ±5% or ±0.01 mg/L (whichever is greater) within 0.01–50 mg/L |
| Detection Limit | 0.01 mg/L (as N) |
| Analysis Time | ≤30 minutes per cycle |
| Sample Throughput | Continuous online operation (no batch processing) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | Orion 3150 |
| Instrument Type | Online Analyzer |
| Measurement Principle | Spectrophotometry (UV-Vis) |
| Measuring Parameters | Total Phosphorus (TP) and Total Nitrogen (TN) |
| Range | 0–2 / 0–10 / 0–50 mg/L (user-selectable ranges per parameter) |
| Accuracy | ±5% of reading |
| Detection Limit | 0.005 mg/L |
| Resolution | 0.01 mg/L |
| Light Source (TN module) | Xenon flash lamp (rated for >10⁸ flashes) |
| Sample Handling | Integrated digestion-colorimetric cell with automated reagent dosing and thermal digestion |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | Orion 3150 |
| Measurement Parameters | Total Phosphorus (TP) and Total Nitrogen (TN) |
| Instrument Type | Online Analyzer |
| Measurement Principle | Spectrophotometry (UV-Vis) |
| Measurement Ranges | 0–2 mg/L, 0–10 mg/L, 0–50 mg/L (auto-ranging) |
| Accuracy | ±5% of reading |
| Detection Limit | 0.005 mg/L |
| Resolution | 0.01 mg/L |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | Orion 8010cX |
| Instrument Type | Online Analyzer |
| Measurement Principle | Salicylate Spectrophotometry |
| Measurement Ranges | 0.02–2 mg/L |
| Accuracy | ±3% of reading + 0.04 mg/L (0.02–2 mg/L) |
| Detection Limit | 0.02 mg/L |
| Analysis Time | ≤30 min |
| Environmental Operating Temperature | 5–40 °C |
| Relative Humidity | ≤95% RH (non-condensing) |
| Sample Flow Rate | 50–1000 mL/min |
| Sample Pressure | 1–5 bar |
| Sample Temperature | 5–50 °C |
| Sample Requirements | TDS < 170 mg/L, TSS < 30 mg/L, pH 4–9, Color < 180 Pt-Co units |
| Enclosure Rating | IP65 |
| Dimensions (W×H×D) | 450 × 737 × 322 mm |
| Weight | 40 kg |
| Power Supply | 100–240 VAC, 100 W, 50/60 Hz |
| Analog Outputs | Two 4–20 mA (max. 900 Ω load) |
| Digital Interface | RS485 |
| Relay Outputs | Two dry contacts (2 A @ 250 VAC) |
| Regulatory Compliance | cTUVus, CB, CE-LVD, RCM (safety) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrumentation |
| Model | AQ4EK1 |
| Pricing | Available Upon Request |
| Conductivity Range | 0–20.00 / 200.0 / 2000 µS/cm |
| Conductivity Resolution | 0.01 / 0.1 / 1 µS/cm |
| Conductivity Accuracy | ±1% of Full Scale |
| pH Range | 0.00–14.00 pH |
| pH Resolution | 0.01 pH |
| pH Accuracy | ±0.01 pH |
| pH Electrode Slope | 80–120% |
| mV Range | –1000 to +1000 mV |
| mV Resolution | 1 mV |
| mV Accuracy | ±2 mV |
| Temperature Range (pH/Conductivity) | –10.0–110.0 °C (Conductivity), 0.0–100.0 °C (pH) |
| Temperature Resolution/Accuracy | 0.1 °C / ±0.5 °C |
| Temperature Compensation | Automatic or Manual (0–50 °C for conductivity |
| Cell Constant Options | 0.1, 1.0, 10.0 cm⁻¹ |
| Reference Temperature Options | 20.0 °C or 25.0 °C |
| Conductivity Calibration Points | Up to 1 per range, max 5 total |
| pH Calibration Points | 1–3 points |
| Buffer Standards | USA (pH 4.01, 7.00, 10.01), NIST (pH 4.01, 6.88, 9.18), Pb (pH 4.10, 6.97) |
| Auto-Range Switching | Yes |
| Data Hold Function | Yes |
| Auto-Power-Off | 17 min (pH/mV), 20 min (conductivity) |
| Low-Battery Indicator | Yes (“LO” display) |
| Power Supply | 4 × AAA alkaline batteries |
| Battery Life | >500 h (pH/mV mode), >100 h (conductivity mode) |
| Dimensions | 14 × 7 × 3.5 cm |
| Weight | 200 g |
| Interface | BNC (conductivity sensor), needle-type thermistor port (temperature probe) |
| Display | Custom monochrome LCD |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | 2000i-D / 2000i |
| Typical Configuration | EPA Reference/Equivalent Method PM₂.₅ and Coarse PM Sampler |
| Flow Control | Mass Flow Controller (MFC) |
| Fine Particle Flow Rate | 15 L/min |
| Coarse Particle Flow Rate | 1.67 L/min |
| Filter Format | Dual 47 mm membrane holders |
| Data Logging Interval | 5 min |
| Internal Memory Capacity | 86 days @ 5-min intervals + 32 filter records |
| Communication Interfaces | RS-232, USB, Enhanced Ethernet (iPort™) |
| Operating Temperature Range | −40 °C to +50 °C |
| Compliance | U.S. EPA Reference Method for PM₂.₅ (40 CFR Part 53), Equivalent Method for PM₁₀ and Coarse PM (PM₁₀–PM₂.₅), ASTM D6216, ISO 7708 |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Category | Imported Instrument |
| Model | 2015i/2025i-D |
| Typical Configuration | EPA Reference/Equivalent Method PM₂.₅ and Coarse PM Sampler |
| Flow Control | Mass Flow Controller (MFC) |
| Fine Particle Flow Rate | 15.0 L/min ±2% |
| Coarse Particle Flow Rate | 1.67 L/min ±2% |
| Filter Format | Dual 47 mm membrane filters per sampling cycle |
| Filter Capacity | Up to 16 filter cassettes (32 total filters) |
| Data Logging Interval | 5-minute resolution |
| Internal Memory | 86 days of operational data (5-min intervals) + 32 filter cycle records |
| Communication Interfaces | RS-232, USB 2.0, Ethernet (10/100 Mbps), iPort™ embedded communications module |
| Operating Temperature Range | −40 °C to +50 °C |
| Regulatory Compliance | U.S. EPA Reference Method for PM₂.₅ (40 CFR Part 53), EPA Equivalent Method for PM₂.₅ and Coarse PM (PM₁₀–PM₂.₅), ISO 12103-1, ASTM D1739, EN 12341 |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Shanghai, China |
| Model | Pico & Fresco Microcentrifuge Series (Pico 17 / Pico 21 / Fresco 17 / Fresco 21) |
| Max RCF | 17,000 × g or 21,000 × g |
| Noise Level | <56 dBA (ventilated) / <50 dBA (refrigerated) |
| Motor | Brushless DC |
| Safety Certification | CAMR-validated ClickSeal® biocontainment |
| Rotor Materials | PPSU rotor lids, stainless steel rotors |
| Compliance | ISO 13485 design principles, GLP-compatible operation log |
| Dimensions (W×D×H) | 22.5 × 32.5 × 23.5 cm |
| Weight | ~12 kg |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Model | Precision 173L Low-Temperature |
| Internal Volume | 173 L |
| Temperature Range | −10 °C to +60 °C |
| Temperature Uniformity | ±1 °C at 37 °C |
| Temperature Sensitivity | ±0.1 °C at 37 °C |
| Air Circulation | Forced-air (mechanical convection) |
| Controller | Microprocessor-based with LED display |
| Sensor Type | RTD (Resistance Temperature Detector) |
| Insulation | Foamed polyurethane |
| Refrigerant | Non-CFC, non-HCFC |
| Shelving | 2 standard shelves (up to 4 optional) |
| External Dimensions (W×H×D) | 61 × 88 × 62 cm |
| Internal Dimensions (W×H×D) | 52 × 70 × 53 cm |
| Power Supply | 230 V, 50/60 Hz |
| Power Consumption | 800 W |
| Safety Features | Setpoint lockout, high/low temperature alarm, door-open alert |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | Precision 818 |
| Internal Volume | 504 L |
| Air Circulation | Forced-air (mechanical convection) |
| Temperature Controller | Microprocessor-based |
| Display | LED |
| Temperature Range | −10°C to 50°C (light off) |
| Temperature Uniformity | ±0.2°C at −10°C (light off) |
| Temperature Recovery | ≤10 min after 30-sec door opening at 20°C |
| Insulation | Non-CFC polyurethane foam (cabinet) |
| Shelving | 6 standard adjustable shelves (max. 6) |
| External Dimensions (W×H×D) | 82 × 191 × 74 cm |
| Internal Dimensions (W×H×D) | 67.3 × 144.8 × 50.8 cm |
| Power Supply | 230 V, 50/60 Hz |
| Power Consumption | 860 W |
| Lighting System | Dual fluorescent lamps, total output up to 300 µmol/m²/s (PPFD), uniform irradiance distribution |
| Programmability | 7-day weekly schedule |
| Compliance | Designed and manufactured in accordance with IEC 61010-1, UL 61010-1, and ISO 14644-1 Class 8 cleanroom-compatible airflow design principles |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | Precision Large-Capacity BOD Low-Temperature Incubator (Model 815) |
| Internal Volume | 566 L |
| Temperature Range | –10 °C to 50 °C |
| Temperature Uniformity | ±0.9 °C at –10 °C |
| Temperature Stability | ±0.1 °C at 37 °C |
| Recovery Time | ≤10 min (after 30-sec door opening at 20 °C) |
| Air Circulation | Forced-air (mechanical convection) |
| Shelving | 6 fixed shelves (standard and maximum) |
| Insulation | Non-CFC polyurethane foam (cabinet) |
| External Dimensions (W×H×D) | 82 × 191 × 74 cm |
| Internal Dimensions (W×H×D) | 67.3 × 144.8 × 50.8 cm |
| Power Supply | 230 V, 50/60 Hz |
| Power Consumption | 800 W |
| Interface | RS232 serial port |
| Data Logging | External chart recorder compatible |
| Display | LED digital display |
| Control System | Microprocessor-based temperature controller |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | South Korea |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Thermo Scientific Orbital Shaking Metal Block Incubator Bath |
| Price Range | USD 1,400 – 2,800 |
| Instrument Type | Specialty Orbital Shaker with Integrated Thermostatic Control |
| Timer Range | 1 min – 99 hrs 59 min or Continuous Operation |
| Oscillation Speed | 150–1500 rpm (dependent on block configuration) |
| Temperature Range | RT + 5 °C to 100 °C |
| Heating Block Configuration | Single removable block platform |
| Programmability | 10 user-defined protocols, each supporting up to 10 sequential steps (oscillation ON/OFF cycles) |
| Timing Modes | Dual-mode timer — start-on-temperature-reach or immediate start-on-activation |
| Block Exchange | Tool-free, rapid-swap metal block system |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Thermo Scientific QuasOr |
| Pricing | Upon Request |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Shanghai, China |
| Model | Quattro ESEM |
| Vacuum Modes | High Vacuum / Low Vacuum / Environmental SEM (ESEM) |
| Resolution | 0.8 nm @ 30 kV (STEM), 1.0 nm @ 30 kV (SE), 3.0 nm @ 1 kV (SE), 1.3 nm @ 30 kV (ESEM/low vacuum) |
| Stage | 5-axis motorized eucentric stage, 105° tilt, 110 × 110 mm² travel |
| Chamber | 340 mm internal width, 12 ports, supports up to three EDS detectors (180° symmetric), co-planar EBSD interface, WDS port |
| Optional In-situ Accessories | -165°C to 1400°C heating/cooling stages, GIS for EBID (Pt, W, C), Peltier stage (-20°C to +60°C), liquid nitrogen cryo-stage, nanomanipulator, multi-probe station |
| Detectors | ETD, LVD, GSED, IR-CCD, Nav-Cam+, DBS, STEM 3+, WetSTEM, RGB-CLD, EDS, EBSD, WDS, Raman, EBIC |
| Software | AutoScript 4 (Python API), Maps, TopoMaps, ChemiSEM (real-time EDS quantification, point/line/map analysis) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | South Korea |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Thermo Scientific Refrigerated/Heating Dry Block Incubator |
| Price Range | USD 1,400 – 2,800 (based on current exchange rate and configuration) |
| Instrument Type | Programmable Dry Bath Incubator (Non-shaking) |
| Timer Range | 1 min – 99 hrs 59 min / Continuous Operation |
| Temperature Range | 4 °C to 95 °C |
| Temperature Uniformity at 37 °C | ±0.55 °C |
| Programmable Protocols | 10 user-defined programs, up to 10 steps per program |
| Timing Modes | Start-on-reach & Start-on-set |
| Heating Block Compatibility | Interchangeable modular blocks (e.g., part #88880030) |
| Display | Digital LED with real-time temperature readout |
| Control System | PID feedback algorithm |
| Internal Dimensions (W×D×H) | 99 × 77.5 × 36 mm |
| External Dimensions (W×D×H) | 276 × 334 × 165 mm |
| Weight | 5 kg |
| Power Supply | 230 V, 50/60 Hz |
| Certifications | CE compliant |