Thermo Fisher Scientific
Filter
Showing 91–120 of 409 results
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CleanConnect™ |
| Pricing | Upon Request |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | CON700 |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher Scientific |
|---|---|
| Model | COND600 |
| Origin | USA |
| Instrument Type | Portable Conductivity/TDS/Temp Meter |
| IP Rating | IP67 |
| GLP Compliance | Yes |
| Measurement Principles | Two-electrode AC conductivity, temperature-compensated TDS calculation (linear α coefficient), NIST-traceable calibration |
| Key Ranges | Conductivity 0–200.0 mS/cm (5-range auto-ranging) |
| Resolution | 0.01 µS/cm (low range) to 0.1 mS/cm (high range) |
| Accuracy | ±1% of full scale + 1 LSD (conductivity & TDS) |
| Calibration | Up to 4-point automatic or 5-point manual using standard KCl solutions |
| Temperature Compensation | Linear, user-selectable α (0.00 to 10.00 %/°C), default 2.00 %/°C |
| Electrode Constant Range | 0.010–10.000 cm⁻¹ |
| Data Storage | 500 measurement sets with timestamp, temperature, and electrode ID |
| Connectivity | RS-232C serial port, IrDA infrared interface |
| Power | 4×AA alkaline batteries (≥200 h operation) or optional 9 V DC adapter (500 mA) |
| Dimensions (unit) | 18.3 × 9.5 × 5.7 cm |
| Weight (unit) | 460 g |
| Operating Environment | 0–50 °C, ≤95% RH non-condensing |
| Storage Environment | −25–70 °C |
| Display | Backlit LCD (5.4 × 7.1 cm active area), multi-parameter real-time view |
| Auto-off | Configurable 2–30 min idle timeout |
| Auto-hold | Yes |
| Certifications | CE, RoHS, FCC Class B |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Continuum XL |
| Pricing | Available upon request |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | Thermo Fisher Corona CAD |
| Pricing | Upon Request |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | Corona Ultra CAD |
| Detection Principle | Charged Aerosol Detection (CAD) |
| Power Supply | 100–240 V AC, 100 VA |
| Serial Number | DU-0136 |
| Age | 3–5 years |
| Warranty | 6 months |
| Compliance | Designed for GLP/GMP-compliant laboratories |
| Software Compatibility | Compatible with Chromeleon CDS (v7.2+), Empower (v3+), and other industry-standard chromatography data systems |
| Regulatory Alignment | Supports 21 CFR Part 11 audit trail requirements when paired with validated CDS configurations |
| Sample Compatibility | Non-volatile and semi-volatile analytes across small molecules to macromolecules |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Corona Veo |
| Instrument Type | Universal Chromatographic Detector |
| Flow Rate Range | 0.01–2.0 mL/min |
| Detection Principle | Charged Aerosol Detection (CAD) |
| Sensitivity | Sub-nanogram |
| Linear Dynamic Range | >4 orders of magnitude |
| Compatibility | HPLC, UHPLC, microLC, capillary LC |
| Software Drivers | Chromeleon CDS, ChemStation, EZChrom, OpenLab, Empower 2/3 |
| Regulatory Compliance | Supports 21 CFR Part 11 audit trails, GLP/GMP-compliant data integrity workflows |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Shanghai, China |
| Model | Countess 3 Automated Cell Counter |
| Detection Modes | Brightfield and Fluorescence (optional FL configuration) |
| Sample Throughput | ~20 seconds per sample |
| Cell Size Range | 4–60 µm |
| Compatible Slides | Disposable and Reusable Countess Slides |
| Software | Pre-installed Countess Software v3.x with Onboard Image Capture & Analysis |
| Compliance | Designed for GLP-compliant workflows |
| Connectivity | USB, Ethernet, Optional Wi-Fi module |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | CTS Rotea Counter-Flow Centrifugation System |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | CD650 |
| Instrument Category | Portable/Handheld Water Quality Analyzer |
| Key Parameters | Conductivity / TDS / Salinity / Resistivity / Dissolved Oxygen (DO) / Temperature |
| IP Rating | IP67 |
| Calibration | Auto 4-point (Conductivity), Manual 5-point (Conductivity), Single- or Multi-point DO |
| Electrode Support | Dual- or Quad-ring conductivity cells (cell constant 0.010–10.000 cm⁻¹) |
| DO Measurement Range | 0.00–90.00 mg/L (ppm) and 0.0–600.0% saturation |
| Conductivity Range | 0–500.0 mS/cm across five auto-ranging scales |
| Temperature Range (Instrument) | −10.0–110.0 °C |
| (DO Sensor) | 0–60.0 °C |
| Resolution | 0.01 μS/cm, 0.001 mS/cm, 0.01 mg/L, 0.1 °C |
| Accuracy | ±1% full scale + 1 LSD (Conductivity/TDS/Salinity/Resistivity), ±0.2 mg/L (DO), ±0.5 °C (Temperature) |
| Data Storage | 500 measurement sets |
| GLP Compliance | Yes |
| Communication | IrDA infrared, RS232C, optional PC connectivity via CyberLink software |
| Power | 4×AAA alkaline batteries (>200 h life) or 9 V regulated adapter |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | CON 6000 |
| Conductivity Range | 0.000–500.0 mS/cm |
| Resistivity Range | 3 Ω·cm – 100 MΩ·cm |
| TDS Range | 0.0–500.0 ppt |
| Accuracy | ±0.5% of full scale + 1 digit |
| Repeatability | ±0.01% of full scale |
| Temperature Range | −5.0 to 105.0 °C |
| Temp. Accuracy | ±0.2 °C |
| Temp. Repeatability | ±0.1 °C |
| Calibration | Auto or manual up to 4-point per range |
| Cell Constants | 0.1, 1.0, 10.0 cm⁻¹ |
| Display | 640 × 480 pixel color TFT touchscreen |
| Data Storage | Up to 10,000 readings with timestamp and user ID |
| Connectivity | USB, IrDA, RS-232C, Ethernet (RJ45) |
| Power | 9 VDC, 3.3 A, center-negative |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Industrial-Grade Digital Water Quality Sensor System |
| Model | DataStick |
| Controller Compatibility | AV38 Universal Digital Controller (optional) |
| Max Sensor Nodes per Network | 247 |
| Communication Protocols | USB, RS-232, RS-485, Modbus RTU, Profibus DP, DeviceNet, Ethernet |
| Calibration | Factory-calibrated |
| Software | AquaComm™ Configuration & Diagnostics Suite |
| Compliance | Designed for industrial process monitoring in accordance with ISO 5667 (water sampling), ASTM D1129 (standard terminology relating to water), and compatible with GLP/GMP data integrity requirements (audit trail, user access control, electronic signature support in AquaComm v3.2+) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | Digital Orbital Shaker |
| Speed Range | 1–70 rpm |
| Adjustable Tilt Angle | 1°–15° |
| Type | Orbital Shaking Platform for Laboratory Sample Homogenization |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | Dionex ICS-6000 |
| Operating Pressure | Up to 5000 psi (34.5 MPa) |
| Column Compatibility | Capillary and Analytical Format (e.g., 4 µm particle size columns) |
| Detector Options | DC Conductivity Detector (dual-zone temperature control), ED Electrochemical Detector, VWD/PDA UV-Vis Detector |
| Software | Dionex Chromeleon Chromatography Data System (CDS) |
| Compliance | Designed for GLP/GMP environments |
| Typical Service Life | ~10 years (refurbished & validated) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | DO6+ |
| Measurement Principle | Galvanic Cell Electrode |
| Dissolved Oxygen Range | 0.00–19.99 mg/L (ppm) |
| Resolution | 0.01 mg/L |
| Accuracy | ±1.5% of full scale |
| Saturation Range | 0.0–199.9% |
| Resolution | 0.1% |
| Temperature Range | 0.0–50.0 °C (32–122 °F) |
| Temp. Resolution | 0.1 °C |
| Temp. Accuracy | ±0.5 °C |
| Salinity Compensation | 0.0–50.0 ppt (manual input, automatic correction) |
| Pressure Compensation | 500–1499 mmHg or 66.6–199.9 kPa (manual input, automatic compensation) |
| Calibration | Two-point (0% and 100% O₂) |
| Temperature Compensation | ATC/MTC (0.0–50.0 °C) |
| Electrode Type | Galvanic (self-polarizing) sensor |
| Response Time (t₉₅) | ≤60 s |
| Data Hold & Auto-Off | Yes (20 min inactivity) |
| Display | Single-line LCD |
| Input Interfaces | BNC + 2.5 mm audio jack |
| Power | 4 × AAA alkaline batteries |
| Battery Life | >700 hours |
| Dimensions (instrument) | 14 × 17 × 3.5 cm |
| Weight (instrument) | 200 g |
| Packaging Dimensions | 24 × 17 × 8 cm |
| Weight (shipping) | 0.55 kg |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Dual Star Kit |
| Instrument Type | Benchtop |
| Parameter Channels | Dual-Channel (pH + ISE) |
| pH Accuracy | ±0.001 |
| pH Range | −2.000 to 19.999 |
| Resolution | 0.1 / 0.01 / 0.001 (user-selectable) |
| mV Range | ±1999.9 mV |
| mV Resolution | 0.1 mV |
| mV Accuracy | ±0.1 mV |
| ISE Concentration Range | 0–19999 (with up to 3 significant digits) |
| ISE Accuracy | ±0.1 mV equivalent |
| Temperature Range | −5 to 105 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.1 °C |
| Calibration Points | pH: 1–6 pts |
| ISE | 2–6 pts |
| Calibration Modes | Linear, Nonlinear, Standard Addition/Subtraction, Auto-Blank Correction |
| Data Storage | 1000 GLP-compliant entries (manual, timed, or auto-triggered) |
| Input Interfaces | Two BNC pH/ISE electrode ports, one 8-pin mini-DIN ATC probe port, reference electrode input |
| Output Interfaces | RS232, USB |
| Power Supply | 100–240 V AC adapter |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Dual Star |
| Instrument Type | Multifunctional Electrochemical Analyzer |
| pH Range | –2.000 to 19.999 |
| pH Resolution | 0.1 / 0.01 / 0.001 |
| pH Accuracy | ±0.001 |
| Calibration Points | 1–6 |
| Auto-Buffer Recognition | US, NIST, DIN, and User-Defined Buffers |
| Ion Concentration Range | 0–19999 |
| Ion Resolution | 1–3 significant digits |
| Ion Accuracy | ±0.1 mV or ±0.05% (whichever is greater) |
| Ion Units | ppm, mg/L, M, %, or unitless |
| ISE Methods | Single or Dual Known Addition/Standard Addition, Sample Addition/Subtraction |
| ORP Range | ±1999.9 mV |
| ORP Resolution | 0.1 mV |
| ORP Accuracy | ±0.1 mV or ±0.05% (whichever is greater) |
| Temperature Range | –5 to 105 °C |
| Temperature Resolution | 0.1 °C (–5 to 99.9 °C), 1.0 °C (>99.9 °C) |
| Temperature Accuracy | ±0.1 °C |
| Display | Dual-channel LCD |
| Inputs | Two BNC, Two Reference Electrode, Two MiniDIN (for ATC probes) |
| Method Storage | 20 methods |
| Password Protection | Yes |
| Data Storage | 1000 readings |
| GLP Compliance | Yes |
| Data Interface | Bidirectional RS232, optional USB cable |
| IP Rating | IP54 |
| Safety Certifications | CE, CSA, UL, TÜV, FCC Class A |
| Operating Environment | 5–45 °C, 5–85% RH (non-condensing) |
| Power Supply | 4×AA batteries or universal AC adapter |
| Dimensions | 9.4 cm (H) × 17.0 cm (W) × 22.4 cm (D) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Dispersive Raman Spectrometer (not FT-Raman) |
| Spectral Range | 50–6000 cm⁻¹ |
| Spectral Resolution | <2 cm⁻¹ |
| Spatial Resolution | Micron-level |
| Minimum Wavenumber | 50 cm⁻¹ |
| Spectral Reproducibility | ±0.2 cm⁻¹ |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | EASY-nLC 1000 |
| Instrument Type | Nanoflow Liquid Chromatography System |
| Column ID | 50 µm |
| Packing Particle Size | 1.9 µm |
| Maximum Operating Pressure | Up to 1000 bar |
| Gradient Precision | <0.2% RSD |
| Flow Rate Range | 50–1000 nL/min |
| Injection Volume Precision | <1% RSD |
| System Dead Volume | <100 nL |
| Software Platform | Thermo Scientific Xcalibur |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | Temp JKT |
| Price | Upon Request |
| Thermocouple Types | J, K, T |
| Temperature Range | –250 °C to 1372 °C (K-type), –250 °C to 400 °C (T-type), –2.00 °C to 1000 °C (J-type) |
| Resolution | 0.1 °C (–99.9 °C to 299.9 °C) |
| Accuracy | ±0.2% of reading + 0.5 °C (t > –99.9 °C) |
| Offset Adjustment | ±10 °C |
| Display | LCD |
| Power | 4 × 1.5 V AAA alkaline batteries |
| Battery Life | >200 hours |
| Operating Temperature | –10 °C to 50 °C |
| Dimensions (unit) | 140 × 70 × 35 mm |
| Weight (unit) | 200 g |
| Input Connector | 2-pin ANSI mini thermocouple interface |
| Data Hold | Yes |
| Auto Power-Off | Yes |
| Low-Battery Indicator | Yes |
| Factory-Calibrated | Yes |
| Self-Diagnostic Functions | Yes |
| Key-Based Calibration | Yes |
| Power-Save Mode | Yes |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Germany |
| Manufacturer | Yes |
| Origin Category | Imported |
| Model | ELEMENT 2 |
| Instrument Type | Magnetic Sector ICP-MS (not quadrupole) |
| Sensitivity | >10⁹ cps/ppm for In |
| Resolution | 300, 4,000, and 10,000 (10% valley definition) |
| Dynamic Range | >10⁹ (linear) |
| Background Equivalent Concentration (BEC) | <0.2 cps |
| Detection Mode | Simultaneous multi-element detection for transient signals |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Czech Republic |
| Model | ELITE |
| Type | Lock-in Thermography Inspection System for Semiconductor Failure Analysis |
| Compliance | Designed for ISO/IEC 17025-aligned lab environments, compatible with GLP/GMP documentation workflows |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | ES01 |
| Service Fee | USD 7,000–14,000 (quoted per project) |
| Industry Experience | >10 years |
| Emergency Response Time | ≤12 hours |
| Scope | Cross-brand, multi-sector full-laboratory relocation |
| Service Coverage | Nationwide (China) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | ESCALAB Xi+ |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Singapore |
| Manufacturer | Eutech Instruments (a Thermo Fisher brand) |
| Type | Portable Conductivity/TDS/Temperature Meter |
| Model | CON110 |
| Conductivity Range | 0–199.9 mS/cm (5 ranges) |
| Resolution | 0.05% of full scale |
| Conductivity Accuracy | ±1% FS + 1 LSD |
| TDS Range | 0–99.9 ppt (adjustable coefficient 0.40–1.00) |
| TDS Accuracy | ±1% FS + 1 LSD |
| Temperature Range | 0–100.0 °C |
| Temp Accuracy | ±0.5 °C |
| Temp Compensation | Automatic/manual (0–80 °C) |
| Calibration | Auto 4-point / Manual 5-point |
| Data Storage | 100 measurement sets with timestamp |
| Electrode Constant Display | Yes (0.1, 1.0, 10.0 cm⁻¹) |
| Interface | RS232C |
| Power | 4×AAA alkaline batteries (200+ hr life) or 9 V DC adapter |
| Dimensions (unit) | 18 × 9 × 4 cm |
| Weight (unit) | 220 g |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Singapore |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | COND600 |
| Price | Upon Request |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Singapore |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | CD650 |
| Instrument Category | Portable / Handheld Water Quality Analyzer |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Singapore |
| Manufacturer | Eutech Instruments (a Thermo Fisher brand) |
| Type | Benchtop Conductivity/TDS/Temp Meter |
| Model | CON510 |
| Key Features | Auto-ranging (5 ranges), 4-point auto-calibration & 5-point manual calibration, built-in temperature compensation (NTC thermistor), 100-data storage, adjustable TDS factor, electrode constant selection (0.1 / 1.0 / 10.0 cm⁻¹) |
| Conductivity Range | 0–19.99 μS/cm, 20.0–199.9 μS/cm, 200–1999 μS/cm, 2.00–19.99 mS/cm, 20.0–199.9 mS/cm |
| Conductivity Resolution | 0.01 / 0.1 μS/cm |
| TDS Range (user-selectable factor) | 0–9.99 ppm, 10.0–99.9 ppm, 100–999 ppm, 1.00–9.99 ppt, 10.0–99.9 ppt, 0–199.9 ppt |
| TDS Resolution | 0.01 / 0.1 / 1 ppm |
| Conductivity Accuracy | ±1% full scale |
| Temperature Range | 0.0–80.0 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.5 °C |
| Temp. Compensation Coefficient | 0.0–10.0 %/°C |
| Reference Temperature | 15.0–30.0 °C |
| Display | LCD (5.9 × 3.2 cm), backlit |
| Power | 9 V DC regulated adapter (100–220 VAC input, linear supply) |
| Dimensions (H×W×D) | 23 × 18 × 6 cm |
| Weight | 750 g (instrument only) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | CON6000 |
| Price | Upon Request |
| Conductivity Range | 0–200 μS/cm, 200.0 μS/cm–2.000 mS/cm, 2.000–20.00 mS/cm, 20.00–500.0 mS/cm |
| TDS Range | 0–200.0 ppm, 200.0–2000 ppm, 2.000–20.00 ppt, 20.00–500.0 ppt |
| Salinity Range | 0–90.00 ppt |
| Resistivity Range | 0–19.99 kΩ, 20.00–199.9 kΩ, 200.0 kΩ–1.999 MΩ, 2.000–100.0 MΩ |
| Temperature Range | −5.0–105.0 °C |
| Conductivity Accuracy | ±0.5% of full scale + 1 LSD |
| TDS/Salinity/Resistivity Accuracy | ±0.5% of full scale + 1 LSD |
| Temperature Accuracy | ±0.2 °C |
| Temperature Compensation | Automatic or manual (−5 to 100 °C), adjustable coefficient (0.000–10.000 %/°C), reference temperature (15.0–30.0 °C) |
| Calibration | Up to 4-point, auto- or manual |
| Electrode Constants Supported | 0.1, 1.0, 10.0 cm⁻¹ |
| Data Storage | 1,000 readings per user |
| Display | 11.43 × 15.24 cm Windows CE–based color touchscreen |
| Connectivity | BNC, DIN, phono sockets, SD card reader, USB (host & device), RS232C, RJ45, IrDA |
| Power Supply | 9 V DC regulated adapter (100–240 VAC input, SMPS) |
| Dimensions (H×W×D) | 16.5 × 23.5 × 8.9 cm |
| Weight | 1.1 kg (instrument only) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Singapore |
| Manufacturer | Thermo Fisher Scientific |
| Country of Origin | Imported |
| Model | DO110 |
| Instrument Type | Portable |
| Electrode Type | Galvanic Cell |
| DO Range | 0.00–19.99 mg/L (ppm) |
| DO Resolution | 0.01 mg/L |
| DO Accuracy | ±1.5% of full scale |
| Saturation Range | 0.0–199.9% |
| Saturation Resolution | 0.1% |
| Salinity Compensation | 0.0–50.0 ppt (manual entry, auto-applied) |
| Atmospheric Pressure Compensation | 500–1499 mmHg / 66.6–199.9 kPa (manual entry, auto-applied) |
| Temperature Range | 0.0–50.0 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.3 °C |
| Calibration | Dual-point (% saturation) or single-point (mg/L) |
| Data Storage | 100 measurement sets |
| Display | Dual-line LCD (5.8 × 3.3 cm) |
| IP Rating | IP54 |
| Power | 4 × AA alkaline batteries (typical life >700 h) or 9 V regulated DC adapter (200 mA) |
| Dimensions (instrument) | 18 × 9 × 4 cm |
| Weight (instrument) | 220 g |