Thermo Fisher Scientific
Filter
Showing 181–210 of 409 results
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | Photoelectric-Controlled Rocking Shaker |
| Speed Range | 5–100 rpm |
| Adjustable Tilt Angle | 7°–13° |
| Distribution Type | Imported Instrument (Distributed by Authorized General Distributor) |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Type | Imported Instrument |
| Model | 3-Star |
| Price | Upon Request |
| Conductivity Range | 0.000–3000 mS/cm |
| Resolution | Up to 4 significant digits, down to 0.001 μS/cm |
| Accuracy | ±0.5% of reading or ±0.01 μS/cm (whichever is greater) |
| Resistivity Range | 0.0001–100 MΩ·cm |
| Salinity Range | 0.01–80.0 ppt NaCl |
| TDS Range | 0–19999 mg/L |
| Cell Constant Range | 0.001–199.9 cm⁻¹ |
| Reference Temperatures | 5, 10, 15, 20, or 25 °C |
| Electrode Compatibility | Two-electrode, four-electrode, and planar conductivity cells |
| Calibration Points | 1–5 manual points |
| Temperature Range | −5 to 105 °C |
| Temp. Resolution | 0.1 °C (−5 to 99.9 °C), 1.0 °C (>99.9 °C) |
| Temp. Accuracy | ±0.1 °C |
| Temp. Compensation | Automatic or manual |
| Display | Backlit LCD with icon-driven interface |
| Input Interfaces | pH-BNC, temperature-miniDIN, stirrer-Phono-jack (benchtop only) |
| Communication | Bidirectional RS232, optional USB cable |
| Data Logging | 1000 readings |
| Calibration History | Last 10 calibrations stored |
| Method Storage | 10 user-defined methods |
| Password Protection | 10 independent user profiles |
| Power | 4×AA alkaline batteries |
| Certifications | CE, CSA, UL, TÜV, FCC Class A |
| Operating Environment | 5–45 °C, 5–85% RH (non-condensing) |
| IP Rating | Benchtop: IP54 |
| Portable | IP67 |
| Dimensions (Benchtop) | 9.4 × 17.0 × 22.4 cm (H×W×L) |
| (Portable) | 4.8 × 9.7 × 21.3 cm (H×W×L) |
| Battery Life (Portable) | ~2000 hours |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | 4-Star |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic (China-manufactured) |
| Model | Orion 8006cX Online COD Analyzer |
| Instrument Type | Online Analyzer |
| Measurement Range | 0–1000 mg/L and 1000–5000 mg/L |
| LOD | 10 mg/L |
| Chloride Interference Tolerance | up to 5000 mg/L |
| Compliance | HJ/T 399–2007, HJ 377–2019, HJ 35X–2019 |
| Certification | CCEP (China Environmental Protection Product Certification) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | CFNN11 |
| Pricing | Available upon Request |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Benchtop Dual-Channel Ion Concentration and pH Meter |
| Model | D10P-20 |
| Ion Measurement Range | 0–19999 (in user-selectable units: ppm, mg/L, M, %, or unitless) |
| Detection Limit | 0.1 ppm Ca²⁺ (as specified with 9720BNWP electrode) |
| Response Time | <30 s (t₉₀, typical for ISE in stirred aqueous samples) |
| Measurement Accuracy | ±0.1 mV or ±0.05% of reading (whichever is greater) |
| Temperature Range | –5 to 105 °C |
| Electrode Compatibility | Orion 9720BNWP Calcium ISE, 927007MD ATC probe |
| Compliance | GLP-compliant data logging, CE, CSA, UL, TÜV, FCC Class A, IP54 |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | D10P-70 |
| Pricing | Available Upon Request |
| Electrode | 9770BNWP Free Chlorine Sensor |
| Measurement Range (Cl₂) | 0.01–20 ppm |
| Detection Limit | 3 × 10⁻⁷ M |
| pH Range | 0–14 |
| Temperature Range (Continuous) | 0–50 °C |
| Temperature Range (Intermittent) | 50–100 °C |
| Repeatability | ±2% |
| Electrode Slope | 28 ± 2 mV/decade |
| Electrode Dimensions | 110 mm length, 12 mm body diameter, 16 mm cap diameter |
| Cable Length | 1 m |
| Dual Channel Capability | pH + ISE (e.g., Cl₂, NH₄⁺, F⁻, Na⁺, K⁺, Br⁻, NO₃⁻) |
| Ion Concentration Range | 0–19999 (units: ppm, mg/L, M, %, or unitless) |
| Resolution | 1–3 significant digits |
| Accuracy (Ion) | ±0.1 mV or ±0.05% (whichever is greater) |
| pH Range | −2.000 to 19.999 |
| pH Resolution | 0.001 |
| pH Accuracy | ±0.001 |
| ORP Range | ±1999.9 mV |
| ORP Resolution | 0.1 mV |
| Temperature Range | −5 to 105 °C |
| Temp Accuracy | ±0.1 °C |
| Display | Dual-channel LCD |
| Interfaces | Dual BNC, Dual Reference, Dual MiniDIN (for ATC probes) |
| Methods Stored | 20 |
| Data Storage | 1000 entries with timestamp |
| GLP Compliance | Yes (audit trail, user password, method-level security) |
| Connectivity | RS232 (bidirectional), optional USB cable |
| Enclosure Rating | IP54 |
| Certifications | CE, CSA, UL, TÜV, FCC Class A |
| Power | 4×AA batteries or universal AC adapter |
| Dimensions | 9.4 × 17.0 × 22.4 cm (H × W × L) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Dual Star |
| Instrument Type | Multi-Ion Analyzer |
| pH Range | –2.000 to 19.999 |
| pH Resolution | 0.1 / 0.01 / 0.001 |
| pH Accuracy | ±0.001 |
| Calibration Points | 1–6 |
| Auto-Buffer Recognition | US, NIST, DIN, and User-Defined |
| Ion Concentration Range | 0–19999 |
| Ion Resolution | 1–3 Significant Digits |
| Ion Accuracy | ±0.1 mV or ±0.05% (whichever is greater) |
| Units | ppm, mg/L, M, %, or unitless |
| Measurement Modes | Single or Dual Standard Addition/Standard Subtraction |
| ORP Range | ±1999.9 mV |
| ORP Resolution | 0.1 mV |
| ORP Accuracy | ±0.1 mV or ±0.05% (whichever is greater) |
| Temperature Range | –5 to 105 °C |
| Temp Resolution | 0.1 °C (–5 to 99.9 °C), 1.0 °C (>99.9 °C) |
| Temp Accuracy | ±0.1 °C |
| Display | Dual-channel LCD |
| Input Interfaces | Two BNC, Two Reference Electrode, Two MiniDIN (for temperature probes) |
| Method Storage | 20 methods |
| Password Protection | Yes |
| Data Storage | 1000 readings |
| GLP Compliance | Yes |
| Data Interface | Bidirectional RS232, optional USB cable |
| IP Rating | IP54 |
| Certifications | CE, CSA, UL, TÜV, FCC Class A |
| Operating Environment | 5–45 °C, 5–85% RH (non-condensing) |
| Power Supply | 4×AA batteries or universal AC adapter |
| Dimensions | 9.4 × 17.0 × 22.4 cm (H×W×L) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | 420D-01A |
| Instrument Type | Portable |
| Measurement Principle | Fluorescence-based (RDO) and Polarographic DO |
| pH Range | −2.000–20.000 |
| pH Resolution | 0.001 |
| pH Accuracy | ±0.001 |
| pH Calibration Points | Up to 5 |
| mV Range | ±2000.0 mV |
| mV Resolution | 0.1 mV |
| DO Concentration (RDO) | 0–50 mg/L |
| DO Accuracy (RDO) | ±0.1 mg/L (0–8 mg/L), ±0.2 mg/L (8–20 mg/L), ±10% of reading (20–50 mg/L) |
| DO Saturation | 0–500% |
| Saturation Accuracy | ±2% |
| Temperature Range | −5 to 105 °C |
| Temp Resolution | 0.1 °C |
| Temp Accuracy | ±0.1 °C |
| Data Storage | 5000 GLP-compliant entries |
| Protection Rating | IP67 (portable unit) |
| Interface | USB, RS232 |
| Power | 4×AA batteries or AC adapter |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Type | Imported Instrument |
| Model | Star A211 |
| Price | Upon Request |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Singapore |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Laboratory Instrument |
| Model | A213 (Benchtop), A223 (Portable) |
| Measurement Principle | Electrochemical (Galvanic Cell) and Optical (RDO Fluorescence) |
| DO Range | 0–90 mg/L (Galvanic), 0–50 mg/L (RDO) |
| Accuracy | ±0.2 mg/L (Galvanic) |
| Saturation Range | 0–600% (Galvanic), 0–500% (RDO) |
| Atmospheric Pressure Compensation | 450.0–850.0 mmHg |
| Salinity Correction | 0–45 ppt |
| Temperature Range | 0–50 °C |
| Resolution | 0.01/0.1 mg/L |
| Data Storage | 2000 entries (A213), 1000 entries (A223), GLP-compliant |
| Interface | RS232, USB |
| Power | AC adapter (100–240 V AC) or 4 × AA batteries |
| IP Rating | IP54 (A213), IP67 (A223) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | A214, A324 |
| Instrument Type | Multi-Ion Analyzer |
| Measurement Modules | pH/Temp, pH/ISE/Temp, pH/LogR/Temp, Conductivity/Temp, DO/Temp |
| Data Storage | 2000–5000 entries (GLP-compliant) |
| Display | Full-color LCD with multi-parameter overlay |
| Connectivity | Dual USB + RS232 |
| Protection Rating | IP54 (benchtop), IP67 (portable A329) |
| Power Options | AC adapter (90–260 V AC) or 4×AA batteries |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Category | Imported Instrument |
| Model | Star A215 |
| Price | Upon Request |
| pH Range | −2.000 to 19.999 |
| pH Resolution | 0.1 / 0.01 / 0.001 |
| pH Accuracy | ±0.001 |
| pH Calibration | 1–5 points, NIST/US, DIN, and user-defined buffers |
| ORP Range | ±1999.9 mV |
| ORP Resolution | 0.1 mV |
| ORP Accuracy | ±0.1 mV or ±0.05% (whichever is greater) |
| DO Range | 0.00–90.0 mg/L (0.0–600% saturation) |
| DO Resolution | 0.01 mg/L / 0.1% |
| DO Accuracy | ±0.5% ±1 digit |
| Salinity Compensation | 0–45 ppt |
| Barometric Pressure Range | 450–850 mmHg |
| DO Calibration | Air-saturated water, water-saturated air, Winkler titration, zero-point |
| Sensor Type | Polarographic membrane electrode |
| Temperature Range | −5 to 105 °C |
| Temperature Resolution | 0.1 °C (−5 to 99.9 °C), 1.0 °C (>99.9 °C) |
| Temperature Accuracy | ±0.1 °C |
| Temperature Compensation | Automatic or manual |
| Display | Backlit LCD with icon-driven interface |
| Connectivity | Dual-mode RS232, optional USB cable |
| Input Interfaces | pH (BNC), temperature (miniDIN), stirrer (phono-jack, benchtop only) |
| Data Logging | 750 measurements |
| Calibration History | Last 10 calibrations |
| Method Storage | 10 user-defined methods |
| Password Protection | 10 independent user profiles |
| Power | 4×AA alkaline batteries (up to 2000 h portable operation) or universal AC adapter (benchtop) |
| Certifications | CE, CSA, UL, TÜV, FCC Class A |
| Environmental Rating | Benchtop IP54 (dust- and splash-resistant) |
| Dimensions (Benchtop) | 9.4 × 17.0 × 22.4 cm (H×W×L) |
| (Portable) | 4.8 × 9.7 × 21.3 cm (H×W×L) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Singapore |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | A215 (Benchtop), A325 (Portable) |
| Instrument Category | Benchtop |
| Parameter Types | Dual (pH & Conductivity) |
| Measurement Accuracy | ±0.001 pH / ±0.5% of reading (conductivity) |
| Conductivity Range | 0.001 μS/cm to 3000 mS/cm |
| Resolution | 0.001 μS/cm minimum or 4 significant digits |
| Calibration Solutions | Auto-recognized (USA/NIST/DIN buffers) |
| Data Storage | 2000 entries (A215), 5000 entries (A325), GLP-compliant |
| Environmental Rating | IP54 (benchtop), IP67 (portable) |
| Power | AC adapter or 4 × AA batteries |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | A215 (Benchtop), A325 (Portable) |
| Measurement Parameters | pH, mV/RmV, Conductivity, TDS, Salinity, Resistivity, Temperature |
| Portability | Benchtop (A215) / IP67-rated Portable (A325) |
| Conductivity Range | 0.001 µS/cm to 3000 mS/cm |
| TDS Range | 1–200 ppt |
| Resistivity Range | 2 Ω·cm to 100 MΩ·cm |
| Salinity Range | 0.01–80.0 ppt NaCl (relative) / 0.01–42 ppt practical salinity |
| Temperature Range | –5 °C to +105 °C |
| pH Accuracy | ±0.001 |
| pH Resolution | 0.1 / 0.01 / 0.001 |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Singapore |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | A216 (Benchtop), A326 (Portable) |
| Instrument Category | Benchtop |
| Parameter Count | Dual (pH & DO) |
| pH Accuracy | ±0.001 |
| pH Measurement Range | −2.000 to 20.000 |
| pH Resolution | 0.1 / 0.01 / 0.001 |
| mV Range | ±2000.0 mV |
| mV Resolution | 0.1 mV |
| mV Accuracy | ±0.1 mV |
| Polarographic DO Range | 0–90 mg/L |
| RDO Fluorescence DO Range | 0–50 mg/L |
| RDO DO Accuracy | ±0.1 mg/L (0–8 mg/L), ±0.2 mg/L (8–20 mg/L), ±10% of reading (20–50 mg/L) |
| DO Saturation Range | 0–600% (polarographic), 0–500% (RDO) |
| DO Saturation Accuracy | ±2% |
| Atmospheric Pressure Compensation | 450.0–850.0 mmHg |
| Salinity Correction | 0–45 ppt |
| Temperature Range | 0–50 °C |
| Temperature Accuracy | ±0.1 °C |
| Data Storage | 2000 entries (A216), 5000 entries (A326), with timestamp, date, sample ID, user ID, calibration data |
| Compliance | GLP-compliant data logging |
| Connectivity | RS232, USB |
| Power | 4 × AA batteries or AC adapter |
| IP Rating | IP54 (A216), IP67 (A326) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Singapore |
| Manufacturer | Thermo Fisher Scientific |
| Origin Category | Imported |
| Model | A216 (Benchtop) / A326 (Portable) |
| Instrument Type | Laboratory |
| pH Range | −2.000 to 20.000 |
| pH Accuracy | ±0.001 |
| pH Resolution | 0.1 / 0.01 / 0.001 |
| mV Range | ±2000.0 mV |
| mV Accuracy | ±0.1 mV |
| DO Measurement Principle | Polarographic or Luminescent (RDO) |
| Polarographic DO Range | 0–90 mg/L (±0.2 mg/L accuracy) |
| RDO DO Range | 0–50 mg/L (±0.1 mg/L @ 0–8 mg/L |
| DO Saturation Range | 0–600% (Polarographic) / 0–500% (RDO) |
| DO Saturation Accuracy | ±2% |
| Atmospheric Pressure Compensation | 450.0–850.0 mmHg |
| Salinity Correction | 0–45 ppt |
| Temperature Range | 0–50 °C |
| Temp Accuracy | ±0.1 °C |
| Data Storage | 2000 entries (A216) / 5000 entries (A326), with timestamp, sample ID, user ID, and calibration metadata |
| Compliance | GLP-compliant data logging, FDA 21 CFR Part 11-ready audit trail support via optional software |
| Enclosure Rating | IP54 (A216), IP67 (A326) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Singapore |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | A221 |
| Instrument Category | Portable |
| Parameter Types | Multi-parameter |
| pH Measurement Range | -2.000 to 20.000 |
| Resolution | 0.1 / 0.01 / 0.001 |
| Accuracy | ±0.001 |
| Calibration Buffer Recognition | USA / NIST / DIN auto-identification |
| Temperature Compensation | Automatic (ATC) with 8-pin mini-DIN probe interface |
| Data Storage | Up to 2000 GLP-compliant entries |
| Connectivity | USB and RS232 |
| Power | 4 × AA batteries or AC adapter |
| IP Rating | IP67 |
| Electrode Interface | BNC + ATC port |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | A322 |
| Detection Parameters | Multi-parameter (Conductivity, TDS, Salinity, Resistivity, Temperature) |
| Portability | Portable |
| Conductivity Range | 0.001 µS/cm to 3000 mS/cm |
| TDS Range | 1–200 ppt |
| Resistivity Range | 2 Ω·cm to 100 MΩ·cm |
| Salinity Range | 0.01–80.0 ppt NaCl (relative) / 0.01–42 ppt practical salinity |
| Temperature Range | −5 to 105 °C |
| Accuracy | ±0.5% of reading |
| Minimum Resolution | 0.001 µS/cm (or 4 significant digits) |
| Compliance | GLP-compliant data logging (5000 entries), ASTM D1125, ISO 7888, USP <645>, EN 27888, FDA 21 CFR Part 11-ready software support |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported |
| Models | 8157BNUMD (Refillable), 8107BNUMD (Low-Maintenance) |
| pH Range | 0–14 |
| pH Accuracy | ±0.03 pH (with ATC) |
| pH Precision | ±0.01 pH |
| Temperature Range | 0–100 °C |
| Temperature Accuracy | ±1.0 °C |
| Reference System | ROSS™ Double-Junction |
| Internal Reference | ROSS™ Liquid Junction |
| Isopotential Point | pH 7 |
| Fill Solution (Refillable) | 3 M KCl |
| Body Material | Epoxy Resin |
| Electrode Length | 120 mm |
| Diameter | 12 mm |
| Compatible Meters | Orion Star™, Aplus™, and PerpHecT® Series |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Singapore |
| Manufacturer | Thermo Fisher Scientific |
| Country of Origin | Imported |
| Model | VERSA STAR |
| Instrument Type | Laboratory Water Quality Analyzer |
| Measurable Parameters | pH, ISE (Ion Selective Electrode), Conductivity, Dissolved Oxygen (DO), Temperature |
| Compliance | GLP-Compliant Data Storage (2000 Records) |
| Connectivity | Dual USB + RS232 |
| Protection Rating | IP54 |
| Operating Modules | Up to 4 Simultaneous Modules |
| Stirrer Support | 2 Orion Star Stirrers (Hot-Swappable) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | Pacific RO |
| Purified Water Grade | ASTM Type III |
| Ion Removal Efficiency | 98% |
| TOC Reduction | 99% |
| Particulate Removal (>0.1 µm) | 99% |
| Pre-filter Configuration | Dual 10-inch (25.4 cm) Cartridges — 5 µm Sediment Filter + Activated Carbon + Anti-scaling Column |
| Resistivity Probe Accuracy | ±0.16 cm⁻¹ |
| Display | Backlit Tilt-adjustable LCD with Real-time Resistivity/Conductivity, Tank Level (%), and Operational Mode Indication |
| Control System | Microprocessor-based with GLP-compliant Event Logging, Password-protected Settings, and RS-232 Data Export (Configurable Interval) |
| Storage Tank | Polyethylene (Pigment-free), Conical-bottom Design for Complete Drainage |
| Footprint | Benchtop or Wall-mountable |
| Flow Rates | 3 / 7 / 12 / 20 / 40 L/hr |
| Data Retention | Up to 4 Weeks of Timestamped System Events and Parameters |
| Compliance | Meets ASTM D1193-20 (Type III Water), Supports GLP/GMP Documentation Requirements |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Germany |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | Pacific TII |
| Output Flow Rates | 3 / 7 / 12 / 20 / 40 L/hr |
| Resistivity | 10–15 MΩ·cm at 25 °C |
| TOC | <30 ppb |
| Particulates (>0.1 µm) | <1 particle/mL |
| Display | Backlit adjustable-angle LCD with resistivity/conductivity, status mode, tank level (%), and temperature (±0.1 °C per USP <645>) |
| Conductivity Cell Constant | 0.01 cm⁻¹ |
| Compliance | GLP-supporting data logging via RS-232 printer interface |
| Installation | Benchtop or wall-mounted |
| Scalability | Field-upgradable to higher flow capacity |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model Series | Partisol |
| Typical Configuration | Total Suspended Particulates (TSP) Sampler |
| Flow Range | Not Specified |
| Vacuum Pressure Capability | Not Specified |
| Flow Stability | Not Specified |
| Maximum Flow Error | Not Specified |
| Operational Duration at High Flow & High Backpressure | Not Specified |
| Service Life at Maximum Flow & Backpressure | Not Specified |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | PC700 |
| pH Range | –2.00 to 16.00 pH |
| pH Resolution | 0.01 pH |
| pH Accuracy | ±0.01 pH + 1 LSD |
| pH Calibration | Up to 5-point (pH 1.68, 4.01, 7.00, 10.01, 12.45) |
| Temperature Range | –10.0 to 110.0 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.5 °C |
| Conductivity Range | 0–200.0 mS/cm |
| Conductivity Resolution | 0.1 / 0.01 mS/cm |
| Conductivity Accuracy | ±1% of full scale |
| Conductivity Calibration | Up to 5-point per range |
| TDS Range | 0–100 ppt (TDS factor 0.5) |
| TDS Resolution | 0.1 / 0.01 ppt |
| TDS Accuracy | ±1% of full scale + 1 digit |
| TDS Calibration | Up to 5-point per range |
| mV Range | ±2000 mV |
| mV Resolution | 0.1 mV (±199.9 mV), 1 mV (>±200 mV) |
| mV Accuracy | ±0.2 mV (±199.9 mV), ±2 mV (>±200 mV) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Singapore |
| Model | pH6+ |
| Instrument Type | Portable |
| Measurement Parameters | pH, ORP, Temperature (°C) |
| pH Range | 0.00–14.00 |
| pH Resolution | 0.01 pH |
| pH Accuracy | ±0.01 pH |
| Temperature Range | 0.0–100.0 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.5 °C |
| ORP Range | ±1000 mV |
| ORP Resolution | 0.1 mV (up to 199.9 mV), 1 mV (above) |
| ORP Accuracy | ±2 mV ±1 LSD |
| Calibration Points | 3-point (pH) |
| Buffer Standards | USA, NIST, PWB |
| ATC/MTC Compensation | 0–100 °C |
| Auto-Off | After 20 min inactivity |
| Power Supply | 4 × 1.5 V AAA alkaline batteries |
| Battery Life | >200 hours |
| Display | LCD (4.5 × 2.3 cm) |
| Dimensions (unit) | 14 × 17 × 3.5 cm |
| Weight (unit) | 200 g |
| Packaging Dimensions | 36 × 28 × 8 cm |
| Packaging Weight | 1500 g |
| Brand | Thermo Fisher Scientific |
|---|---|
| Model | PH700 |
| Origin | USA |
| Type | Benchtop Electrochemical pH Meter |
| pH Range | −2.00 to 16.00 |
| pH Resolution & Accuracy | 0.01, ±0.01 pH |
| mV Range | ±2000 mV |
| mV Resolution & Accuracy | 0.1 mV (±199.9 mV), 1 mV (±200 mV+) |
| Temperature Range | 0.0 to 100.0 °C |
| Temp Resolution & Accuracy | 0.1 °C, ±0.5 °C |
| Calibration Points | Up to 5-point |
| Buffer Standards | USA (pH 4.01, 7.00, 10.01) and NIST (pH 4.01, 6.86, 9.18) |
| Temperature Compensation | Automatic or Manual (0–100 °C) |
| Data Storage | 100 measurements |
| Output Interface | RS-232 or USB (with optional cable) |
| Power Supply | 9 V DC adapter |
| Brand | Thermo Fisher Scientific |
|---|---|
| Model | PHTestr 30 |
| Origin | USA |
| Type | Waterproof Portable pH/Temp Pen Meter |
| Measurement Range | pH –1.00 to 15.00, Temperature 0 to 50 °C |
| Resolution | 0.01 pH / 0.1 °C |
| Accuracy | ±0.01 pH / ±0.5 °C |
| Calibration | Auto 3-point with USA (4.01, 7.00, 10.01) or NIST (4.01, 6.86, 9.18) buffers |
| Temperature Compensation | Automatic (ATC) |
| Electrode Design | Double-junction Ag/AgCl reference system with high-capacity gel electrolyte |
| Auto-off | After 8.5 minutes of inactivity |
| Display | Dual-line LCD (2.1 × 2.7 cm) |
| Power | 4 × 1.5 V button cells (LR44) |
| Battery Life | >500 hours |
| Operating Temperature | 0–50 °C |
| Dimensions (Instrument) | 16.5 × 3.8 cm |
| Weight (Instrument) | 90 g |
| Packaging Dimensions | 18.5 × 6.5 × 5 cm |
| Weight (Packaged) | 200 g |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | Imported |
| Model | pHTestr30 |
| Price | Upon Request |
| pH Range | –1.00 to 15.00 |
| Resolution | 0.01 pH |
| Accuracy | ±0.01 pH |
| Calibration | Up to 3-point, auto-buffer recognition (pH 4.01, 7.00, 10.01) |
| Temperature Range | 0.0 to 50.0 °C |
| Temp. Resolution | 0.1 °C |
| Temp. Accuracy | ±0.1 °C |
| ATC | Built-in automatic temperature compensation |
| Enclosure Rating | IP67 |
| Electrode Design | Dual-junction (double salt bridge), gel-filled KCl electrolyte with enhanced gel volume |
| Electrode Module | Replaceable sensor cartridge |
| Display | Dual-line LCD, configurable °C/°F output |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Integrated Circulating Chiller |
| Cooling Method | Air-Cooled |
| Temperature Range | −10 °C to +80 °C |
| Refrigeration Capacity | 250 W @ 20 °C (Accel 250) / 500 W @ 20 °C (Accel 500) |
| Temperature Stability | ±0.1 °C |
| Reservoir Volume | 2.8 L |
| Pump Flow Rate | Up to 21 L/min (dual-mode pump option) |
| Max. Pump Pressure | 805 mbar (dual-mode) / 300 mbar (pressure-only) |
| Dimensions (W×D×H) | 620 × 232 × 487 mm |
| Weight | 30 kg |
| Noise Level | ≤58 dBA |
| Certifications | UL, CSA, CE, RoHS, DIN 12876 Class 3 / NFL Safety Rating |
| Warranty | 3-Year Global Limited Warranty |