Thermo Fisher Scientific
Filter
Showing 151–180 of 409 results
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestically Produced Equipment |
| Model | Forma Steri-Cycle CO₂ Incubator (Domestically Manufactured) |
| Pricing | Available Upon Request |
| Airflow Cycle Duration | ~14 hr |
| Sterilization Temperature | 140°C |
| Temperature Alarm Threshold | ≥60°C |
| HEPA Filtration Class | ISO Class 5 (Class 100) |
| Control System | Microprocessor-Based with Alphanumeric Display |
| CO₂ Sensor Options | Infrared (IR) or Thermal Conductivity (TC) |
| Humidity Monitoring | Optional |
| Door Configuration | Reversible Swing |
| Compliance Support | IQ/OQ Documentation Kits Available |
| Data Logging | Optional Integrated Datalogger |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | Forma Steri-Cycle i160 |
| Temperature Range & Accuracy | 3–55 °C |
| Temperature Uniformity | ±0.3 °C |
| Humidity Range & Accuracy | 20–95% RH |
| Chamber Capacity | 165 L |
| CO₂ Sensor | IR-based (Si-MEMS), 0–20% range |
| Optional O₂ Control | 1–21% |
| Sterilization | Dry-heat cycle at 180 °C, 12-log SAL |
| Air Filtration | ISO Class 5 HEPA |
| Humidification System | Integrated covered reservoir (condensate-free) |
| Airflow Technology | THRIVE™ laminar airflow |
| Interior Material Options | Electropolished stainless steel or 100% copper |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | i250 |
| Temperature Range & Accuracy | 3 °C to 55 °C (±0.1 °C setpoint stability) |
| Temperature Uniformity | ±0.1 °C across chamber volume |
| Humidity Control | >93% RH at 37 °C |
| Chamber Capacity | 255 L |
| Sterilization Cycle | 140 °C dry-heat, 14-hour duration |
| Air Filtration | Internal HEPA filter (ISO Class 5 / Grade A equivalent), optional VOC adsorption module |
| Sensor Type | High-temperature-resistant TC sensor (in situ during sterilization), IR-based CO₂ sensing |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Authorization | Authorized Distributor |
| Import Status | Imported |
| Model | Forma |
| Price Range | USD $12,500 – $25,000 (FOB) |
| Net Capacity | 368 L |
| Interior Dimensions (mm) | 1308 × 584 × 490 |
| Exterior Dimensions (mm) | 1979 × 846 × 836 |
| Power Supply | 230 V AC, 50 Hz |
| Rated Power Consumption | 400 W |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | GC IsoLink II |
| Instrument Category | Dedicated GC-IRMS Interface System |
| Pricing Range | USD 135,000 – 270,000 (FOB Hamburg) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Genesys 30 |
| Optical Design | Single-Beam |
| Detector Type | Photodiode Array |
| Wavelength Range | 325–1100 nm |
| Wavelength Accuracy | ±1.0 nm |
| Spectral Bandwidth | 5 nm |
| Stray Light | <0.05% at 340 nm and 700 nm |
| Absorbance Range | ±3.0 A |
| Light Source | Tungsten Halogen Lamp |
| Display | 5-inch Full-Color TFT LCD |
| Data Export | USB Mass Storage Mode (TXT format) |
| Software | Onboard VISIONlite UI |
| Warranty | 3 Years Limited |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Czech Republic |
| Model | Helios 5 DualBeam |
| Landing Voltage Range | 20 eV – 30 keV |
| SEM Resolution | Down to 0.6 nm @ 15–30 keV (depending on configuration) |
| FIB Current Range | 1 pA – 100 nA |
| Ion Acceleration Voltage | 500 V – 30 kV |
| Stage Travel | Up to 150 × 150 × 10 mm (X/Y/Z, model-dependent) |
| Automated TEM Lamella Preparation | Supported (via AutoTEM 5 software) |
| STEM Imaging Capability | Integrated (sub-nm resolution at 30 keV) |
| Compliance | Designed for GLP/GMP environments |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic (China-manufactured) |
| Model | Helios 5 DualBeam FIB-SEM |
| Pricing | Upon Request |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Czech Republic |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | Helios 5 Laser PFIB |
| Price Range | USD 920,000 – 1,315,000 |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Czech Republic |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Helios NanoLab DualBeam™ |
| Price Range | USD 1.3M – 1.9M |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | Labofuge 400 R |
| Instrument Type | Benchtop Centrifuge |
| Category | Refrigerated High-Speed Centrifuge |
| Max Speed | 11,500 rpm |
| Max RCF | 12,568 × g |
| Max Capacity | 4 × 180 mL |
| Dimensions (H×W×D) | 310 × 436 × 568 mm |
| Noise Level | ≤ 58 dB(A) |
| Drive System | Brushless Direct-Drive Motor |
| Control System | Microprocessor-Based with Backlit LED Display |
| Timer Range | 1–99 min, plus Short Spin & Continuous Modes |
| Safety Features | Rotor Overspeed Protection, Imbalance Detection, Self-Diagnostic Routine, CAMR-Certified Biocontainment Lid |
| Cooling System | Air-Cooled Refrigeration |
| Acceleration/Deceleration Times | 15–25 s (varies by rotor) |
| Rotor Options | 24 × 1.5 mL Fixed-Angle, 4 × 180 mL Horizontal, 18 × 15 mL Fixed-Angle, Hematocrit, Microplate, and Cytospin-Compatible Rotors |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | General-purpose drying oven |
| Model | OGS60 |
| Temperature Range | +50 to +250 °C |
| Temperature Uniformity | ±4.4 °C at 150 °C (natural convection) |
| Temperature Stability | ±0.4 °C at 150 °C (natural convection) |
| Internal Dimensions | 328 × 480 × 415 mm (W × H × D) |
| External Dimensions | 630 × 720 × 565 mm (W × H × D) |
| Chamber Volume | 65 L |
| Chamber Material | Corrosion-resistant stainless steel with rounded internal corners |
| Heating Method | Natural convection |
| Standard Interface | RS232 |
| Display | Large vacuum fluorescent display (VFD) |
| Door Opening Angle | 180° |
| Safety Features | Over-temperature alarm with independent thermal cut-out |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | ICS-2100 |
| Instrument Type | Laboratory Benchtop System |
| Maximum Pump Pressure | 6000 psi |
| Operating Pressure Range | Up to 5000 psi |
| Column Oven Temperature Range | 4–40 °C |
| Eluent Concentration Range | 0–100 mM KOH (varies with eluent chemistry) |
| Detection Principle | Suppressed Conductivity Detection with Electrolytic Eluent Generation and Electrolytic Sample Preparation |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | 3200 |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher Scientific |
|---|---|
| Model | Iliad |
| Type | Spherical Aberration-Corrected Scanning/Transmission Electron Microscope (S/TEM) |
| Integrated Spectroscopy | Dual-mode EELS (including XEELS™ up to 30 keV) and Energy-Filtered Imaging |
| Detectors | Zebra EELS Detector, NanoPulser Electrostatic Beam Blanking (1 MHz, ≤10 ns pulse width), Optional Dual-X/Super-X/Ultra-X EDX |
| Software | Velox™ (S/TEM, EDX, EELS acquisition & analysis), Autoscript™ TEM (Python-based automation, AI-integrated workflow control) |
| Compliance | Designed for GLP/GMP-aligned labs |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | E-Gel |
| Instrument Category | Standard Gel Imaging System |
| CCD Resolution | 1,296 (H) × 964 (V) |
| Bit Depth | 12-bit |
| Dynamic Range | 56.77 dB |
| CCD Sensor Size | 11 × 14 cm |
| Lens | F/1.4 Optimized Fixed-Focus Lens with 6–12 mm Optical Focal Length |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model Variants | BF51731, BF51732, BF51841, BF51842 |
| Max Temperature | 1200°C |
| Temperature Uniformity | ±2°C @ 1200°C |
| Control Accuracy | ±0.3% of setpoint |
| Max Power | 4500 W |
| Ramp Time to 1200°C | 20 min |
| Heating Method | Calibrated tubular heating elements |
| Internal Dimensions (H×D×W) | 177.8 × 279.4 × 330.2 mm (BF517xx) / 381 × 381 × 381 mm (BF518xx) |
| External Dimensions (H×D×W) | 685.8 × 584.2 × 609.6 mm (BF517xx) / 838.2 × 711.2 × 736.6 mm (BF518xx) |
| Voltage/Frequency | 208–240 V, 50/60 Hz |
| Net Weight | 75 kg (BF517xx) / 127 kg (BF518xx) |
| Controller Options | Single-setpoint, multi-segment single-program, or multi-segment multi-program digital controllers with optional Over-Temperature Control (OTC), RS485 interface, and inert gas flow meter (FM) integration |
| Safety Features | Door-interlocked power cutoff, Platinel II R thermocouple, top 25.4-mm exhaust port, rear 9.5-mm inlet port |
| Insulation | Moldatherm® high-density ceramic fiber board with embedded LGO (Low-Glow Oxide) heating elements |
| Construction | Dual-wall steel housing with air-gap thermal barrier |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | Library Builder™ |
| Price Range | USD 14,000 – 70,000 (est.) |
| Instrument Type | First-Generation Sequencing Library Prep Platform |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Hg-CEMS |
| Instrument Type | Flue Gas Continuous Emission Monitoring System (CEMS) |
| Measurement Principle | Cold Vapor Atomic Fluorescence Spectrometry (CVAFS) with Catalytic Dry Conversion |
| Detection Target | Elemental Mercury (Hg⁰), Oxidized Mercury (Hg²⁺), Total Mercury |
| Detection Limit | 2 ng/m³ (300-s average) |
| Zero Noise | 1 ng/m³ (300-s average) |
| Zero Drift (24 h) | <5 ng/m³ |
| Response Time (T₉₀) | 110 s (60-s averaging) |
| Linearity | ±1% of full scale |
| Hg⁰ Range | 0–50 µg/m³ (pre-dilution) |
| Dilution Ratio | 25:1 to 100:1 |
| SO₂ Interference Rejection Ratio | 8.4×10⁸:1 |
| NOₓ Interference Rejection Ratio | 4.2×10⁹:1 |
| Operating Temperature | 5–40 °C |
| Power Supply | 100/115 VAC ±10%, 275 W |
| Dimensions (W×H×D) | 425 × 219 × 584 mm |
| Weight | 22.2 kg |
| I/O | 16 digital inputs, 10 digital outputs, 6 isolated 0–20/4–20 mA analog outputs, 8 analog inputs (0–10 V), dual RS232/RS485, built-in Ethernet (TCP/IP), Modbus support |
| Compliance | EPA Performance Specification 12A (PS-12A), 40 CFR Part 60 Appendix B, 40 CFR Part 75, ASTM D6784, ISO 15202, GLP/GMP-ready data integrity architecture |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | MFC-TSP |
| Typical Configuration | Total Suspended Particulates (TSP) Sampling System |
| Flow Rate Range | 1.13 m³/min (40 ACFM) |
| Flow Accuracy | < ±1% deviation over 24 h |
| Pressure Drop Compensation | Aerodynamically optimized critical-flow Venturi restrictor |
| Flow Stability | Independent of filter loading, ambient temperature, and barometric pressure |
| Power Supply | 110 VAC, single-phase, 60 Hz (optional configurations available) |
| Motor | 1.0 HP, 7 A, 840 W |
| Weight | 62 kg (total system) |
| Cabinet | 22 kg |
| Cyclone/Cut-point Assembly | 25 kg |
| Blower & Filter Holder | 12 kg |
| Dimensions (Cabinet) | 129 cm H × 56 cm W × 56 cm D |
| Dimensions (Cyclone) | 81 cm H × 81 cm W × 63.5 cm D |
| Dimensions (Blower + Filter Holder) | 71 cm H × 53 cm W × 48 cm D |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | MIRAN SapphIRe |
| Instrument Type | Portable |
| Detection Target | Multi-component Gases |
| Wavelength Range | 7.7–14.1 µm (tunable filter) + seven fixed-bandpass filters at 1.8, 3.3, 3.6, 4.0, 4.2, 4.5, and 4.7 µm |
| Sample Cell Path Length | 0.5 m |
| Sample Cell Volume | 2.23 L |
| Flow Rate | 15 L/min |
| Analysis Time | 20 s (startup) to 3 min (full spectral acquisition) |
| Response Time | ≤18 s to 90% of final reading |
| Display | 8-line × 40-character LCD |
| Power | Internal rechargeable NiCd battery (7.2 V, 5.7 Ah) |
| Dimensions | 553 mm (W) × 365 mm (H) × 193 mm (D) |
| Weight | ~10 kg |
| Preloaded Calibration Curves | Up to 120 gases (configurable per model variant) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Magnetic Stirrer |
| Models | Mobil Direct, Mobil 200, Mobil 600 |
| Maximum Stirring Volume | 150 L (Mobil Direct), 200 L (Mobil 200), 600 L (Mobil 600) |
| Speed Range | 100–1000 rpm |
| Temperature Control Range | −10 °C to +56 °C |
| IP Rating | IP64/IP65 |
| Housing Material | Stainless Steel (Corrosion-Resistant) |
| Stop Time | ≤3 s |
| Operating Humidity | Up to 100% RH (Mobil 200/600), 95% RH (Mobil Direct) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | 111 / 1160 |
| Flow Rate | 1–20 L/min |
| Output Pressure | 10–60 psi |
| Dew Point | −10 °C (membrane dryer) / −40 °C (heatless dryer) |
| Purity | SO₂ < 0.1 ppb, NO < 0.1 ppb, NO₂ < 0.1 ppb, O₃ < 0.4 ppb, H₂S < 0.1 ppb, NH₃ < 0.1 ppb, CO (optional) < 0.02 ppm |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Line | 42i Series |
| Detection Principle | Chemiluminescence |
| Measurement Range | 0–100 ppm (NO/NO₂/NOₓ) |
| LOD | 0.40 ppb (60-s average) |
| Zero Noise | 0.20 ppb RMS |
| 24-hr Zero Drift | < 0.40 ppb |
| 24-hr Span Drift | ±1% of full scale |
| Response Time | < 5 s |
| Operating Modes | Dual-range, Auto-ranging, NO-only, NOₓ-only, or simultaneous NO/NO₂/NOₓ output |
| Calibration | Independent calibration for NO, NO₂, and NOₓ |
| Environmental Correction | Integrated temperature & pressure compensation |
| Connectivity | Ethernet interface with remote access capability |
| Display | High-resolution LCD with customizable soft keys |
| Data Storage | Flash-based memory with extended capacity |
| Compliance | Designed to meet EPA Performance Specification 1 (PS-1), EN 14211, ISO 7935, and supports GLP/GMP audit trails per FDA 21 CFR Part 11 requirements |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | 43i |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | 450i |
| Instrument Type | Online Gas Analyzer |
| Target Analyte | Hydrogen Sulfide (H₂S) |
| Response Time (T₉₀) | 80 s |
| Measurement Accuracy | ±1% of reading or ±1 ppb (whichever is greater) |
| Measurement Ranges | 0–0.05, 0.1, 0.2, 0.5, 1, 2, 5, 10 ppm |
| Extended Ranges | 0–0.5, 1, 2, 5, 10, 20, 50, 100 ppm |
| Mass Concentration Ranges | 0–0.2, 0.5, 1, 2, 5, 10, 25 mg/m³ and 0–2, 5, 10, 20, 50, 100, 200, 250 mg/m³ |
| Zero Noise | 1.0 ppb RMS (60-s averaging) |
| Limit of Detection (LOD) | 2.0 ppb (60-s averaging) |
| Zero Drift (24 h) | <1 ppb |
| Span Drift (24 h) | ±1% of full scale |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | 51i |
| Detection Principle | Flame Ionization Detection (FID) |
| Measurement Range | 0–1 to 0–10,000 ppmC |
| LOD | 0.050 ppmC (10-sec avg) |
| Zero Drift (24h) | <0.50 ppmC |
| Span Drift (24h) | <2% of full scale or 0.20 ppmC (whichever is greater) |
| Response Time (90%) | 15 sec (1-sec avg) |
| Accuracy | ±2.0% of reading or ±0.1 ppmC (whichever is greater) |
| Linearity | ±2% of span (10–150% of full scale) |
| Sample Flow Rate | 0.75–1.50 L/min |
| Combustion Air Flow | 150–300 mL/min |
| Zero Air (HC-free) Flow | 10–35 mL/min (H₂) or 50–120 mL/min (H₂/He mixture) |
| Operating Temperature | 15–35 °C |
| Power | 100/115/220–240 VAC ±10%, 50/60 Hz, 420 W |
| Dimensions (W×H×D) | 425 × 219 × 584 mm |
| Weight | 22.7 kg |
| Outputs | Isolated 0–20 mA / 4–20 mA (optional), RS232/RS485, TCP/IP Ethernet, 10 status relays, power-fail alarm |
| Inputs | 16 digital inputs (standard), 8 analog inputs (0–10 VDC, optional) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Singapore |
| Manufacturer Authorization | Authorized Distributor |
| Import Status | Imported |
| Model | Multiskan SkyHigh |
| Detection Method | Absorbance (Photometry) |
| Function Type | Single-Mode |
| Automation Level | Fully Automated Microplate Reader |
| Assay Modes | Endpoint, Kinetic, and Spectrum Scan |
| Curve Fitting Options | Linear, Point-to-Point, Quadratic, Cubic, Four-Parameter Logistic (4PL), Cubic Spline, Two-Parameter Logarithmic |
| Detector Type | Monochromator-Based |
| Wavelength Range | 200–1,000 nm |
| Absorbance Range | Up to 3.0 Abs |
| Absorbance Linearity | 0–2.5 Abs (±2%) |
| Wavelength Scanning Speed | 10 s (200–1000 nm, 1 nm step) |
| Precision | SD < 0.003 Abs or CV < 1.0% |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Yes |
| Import Status | Imported |
| Model Series | S5P, S14P, S21P |
| Bath Volume | 5 L / 14 L / 21 L |
| Temperature Range | Ambient +13 °C to 100 °C |
| Temperature Stability | ±0.01 °C |
| Circulation Type | Internal & External |
| Control Mode | Heating-Only PID |
| Compliance | UL/CSA/CE, RoHS, DIN 12876 Class 3 / NFL Safety Rating |
| Interface Options | RS232, RS485, USB, Ethernet, Analog I/O, Multi-function Port |
| Safety Alarms | High/Low Temperature, High/Low Liquid Level |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Line | NESLAB Merlin M33, M75, M150, LR |
| Chiller Type | Integrated Air-Cooled Circulating Chiller |
| Temperature Range | –15 °C to 35 °C (with low-temp option) |
| Temperature Stability | ±0.1 °C (M33), ±0.15 °C (M75/M150) |
| Cooling Capacity | 1142 W (M33), 2156 W (M75), 4832 W (M150) at 20 °C fluid & ambient |
| Refrigerant | R134a (M33/M75), R404A (M150) |
| Reservoir Volume | 1.8 L |
| Pump Type | Adjustable pressure, selectable flow (PD1, PD2, or CP55 options) |
| Noise Level | Low-noise operation |
| Compliance | CFC-free refrigeration system, CE-marked, UL/CSA certified for laboratory use |
| Dimensions (H×W×D) | 59.7×32.1×53.0 cm (M33), 66.4×41.3×61.0 cm (M75), 77.2×54.0×74.3 cm (M150) |
| Weight | 54 kg (M33), 80 kg (M75), 115 kg (M150) |