ZHONGKEHUIFEN
Filter
Showing 1–30 of 47 results
| Brand | ZHONGKEHUIFEN |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | GC-7820 |
| Pricing | Available Upon Request |
| Brand | ZHONGKEHUIFEN |
|---|---|
| Origin | Beijing, China |
| Model | GC-7900 |
| Carrier Gas Pressure Control | EPC (Electronic Pressure Control) |
| Column Oven Temperature Range | 80–120 °C |
| Analysis Cycle Time | 30 s (C₁–C₅ hydrocarbons) |
| Retention Time (C₁) | 5.5 s |
| Resolution (k) | ≥0.9 |
| Hydrogen Pressure | 0.3 MPa |
| Air Pressure | 0.25 MPa |
| Column Head Pressure | 0.19 MPa |
| Sample Gas Pressure | 0.04 MPa |
| Sample Gas Flow Rate | >600 mL/min |
| Polarization Voltage | 180 V DC |
| Quantitation Loop Volume | 0.5 mL |
| Amplification Factor | 10⁶ |
| Brand | Zhongkehuifen |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | H2-300 |
| Output Purity | 99.99% (v/v, O₂-equivalent) |
| Flow Rate | 0–300 mL/min |
| Input Voltage | AC 220 V, 50 Hz |
| Operating Temperature | 10–40 °C |
| Relative Humidity | <85% RH |
| Max Power Consumption | 210 W |
| Brand | ZHONGKEHUIFEN |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model Range | Sealing Gasket Series |
| Pricing | Upon Request |
| Brand | ZHONGKEHUIFEN |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Model Series | Tritium Lamp Series |
| Pricing | Available Upon Request |
| Brand | ZHONGKEHUIFEN |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (PRC) |
| Model Series | Valve Components Series |
| Pricing | Available Upon Request |
| Brand | Zhongkehuifen |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Model | 5B-3A |
| Detection Range | 20–1500 mg/L COD |
| Digestion Temperature | 165 °C ±1.0 °C |
| Digestion Time | 10 min |
| Measurement Time | 20 min for up to 9 samples |
| Chloride Interference Tolerance | ≤1000 mg/L (standard), ≤4000 mg/L (with high-chloride correction) |
| Repeatability | ≤0.03% RSD |
| Optical Stability | 0.01 A / 5 min |
| Built-in Calibration Curves | 20 (user-editable and savable) |
| Data Storage Capacity | 1000 records (including parameter ID, timestamp, and value) |
| Display | Integrated LCD |
| Connectivity | RS232 or USB for data export |
| Printer | Built-in thermal printer |
| Brand | Zhongkehuifen |
|---|---|
| Origin | Beijing, China |
| Model | AA-760AFG |
| Instrument Type | Flame and Graphite Furnace AAS |
| Optical System | Dual-beam |
| Monochromator | Czerny-Turner with 1800 lines/mm grating |
| Wavelength Range | 190–900 nm |
| Spectral Bandwidth | 0.1/0.2/0.4/1.0/2.0 nm (auto-switching) |
| Wavelength Accuracy | ±0.10 nm |
| Wavelength Repeatability | 0.05 nm |
| Background Correction | D₂ lamp + Zeeman-effect correction |
| Resolution | Resolves Mn 279.5 nm and 279.8 nm with valley energy <20% |
| Sensitivity (Cu) | 0.02 µg/mL per 1% absorption |
| Detection Limit (Cu, flame) | 0.003 µg/mL |
| Detection Limit (Cd, GF-AAS) | <0.4 pg |
| RSD (flame) | <0.5% |
| RSD (graphite furnace) | <0.8% |
| Detector | Wide-spectrum photomultiplier tube (Hamamatsu) |
| Atomizer | Titanium alloy 100-mm burner (flame) |
| Safety | Acetylene leak detection, automatic gas cutoff, flame failure shutdown |
| Power | AC 220 V / 50 Hz / 150 VA |
| Dimensions | 1110 × 400 × 500 mm (W×D×H) |
| Net Weight | 55 kg |
| Operating Environment | 10–35 °C, ≤80% RH |
| Brand | ZHONGKEHUIFEN |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | AAS6000 |
| Price | Upon Request |
| Wavelength Range | 190–900 nm |
| Monochromator Type | Czerny-Turner |
| Spectral Bandwidth | 0.1 / 0.2 / 0.4 / 0.7 / 1.4 nm (5-step auto-switching) |
| Grating Blaze Wavelength | 230 nm |
| Grating Line Density | 1800 lines/mm |
| Wavelength Accuracy | ±0.25 nm |
| Wavelength Repeatability | <0.10 nm |
| Optical Resolution | <0.3 nm |
| Characteristic Concentration (Cu) | <0.025 µg/mL per 1% absorption |
| Detection Limit (Cu) | <0.006 µg/mL |
| Precision (Cu) | <0.8% RSD |
| Baseline Stability | 0.003 Abs (static), 0.004 Abs (dynamic) |
| Background Correction | D₂ Lamp + Self-Reversal Method |
| Atomization System | Titanium Nebulizer Chamber & Burner Head |
| Nebulizer | Custom Wirsching-type Glass Nebulizer |
| Fuel Control | Continuously Adjustable Acetylene Flow with Real-time Monitoring |
| Communication Interface | USB 2.0 |
| Software Interface | Windows-based, Bilingual (EN/CN), Fully Automated Qualitative & Quantitative Analysis |
| Brand | ZHONGKEHUIFEN |
|---|---|
| Origin | Shanghai, China |
| Model | AKF-2010 |
| Moisture Range | 0.001–100% w/w |
| Resolution | 1 µg H₂O |
| Repeatability | ≥99.7% (at 10 mg water) |
| Max Error | ±0.3% |
| Titration Speed Control | 0.5 µL–0.1 mL adjustable |
| Display | 5.6" TFT LCD (640×480 px) |
| Data Storage | 100,000+ records (expandable) |
| Electrode | Dual-platinum electrode |
| Valve & Tubing Material | FEP-coated electromagnetic 3-way valve |
| Operating Temp | 5–40 °C |
| Humidity Limit | ≤80% RH |
| Power | 220 V / 50 Hz / 50 W |
| Interface Options | RS-232C, USB, Ethernet (Web-enabled) |
| Brand | ZHONGKEHUIFEN |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (PRC) |
| Model Series | Capillary Column Series |
| Pricing | Available Upon Request |
| Brand | ZHONGKEHUIFEN |
|---|---|
| Origin | Beijing, China |
| Model | GC-2060 |
| Temperature Control Range | Ambient + 3°C to 450°C |
| Ramp Rate | 0.1–40°C/min |
| Cooling Time | ~8 min (450°C → 50°C) |
| Carrier Gas Flow Range | 0–1200 mL/min |
| Carrier Gas Pressure Range | 0–970 kPa |
| Injector Max Operating Temperature | 450°C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Column Oven Capacity | Supports up to three independent injectors and optional six-port valve or methanizer |
| FID Sensitivity | ≤5×10⁻¹¹ g/s (n-hexadecane) |
| TCD Sensitivity | ≥3000 mV·mL/mg (benzene/toluene) |
| FPD (S) | ≤5×10⁻¹¹ g/s (parathion-methyl) |
| FPD (P) | ≤3×10⁻¹¹ g/s (parathion-methyl) |
| Baseline Noise (FID) | ≤2.5×10⁻¹⁴ A |
| Baseline Drift (30 min, FID) | ≤5×10⁻¹⁴ A |
| Linearity (FID) | ≥10⁶ |
| Brand | ZHONGKEHUIFEN |
|---|---|
| Origin | Beijing, China |
| Model | GC-2060 |
| Temperature Control Range | Ambient + 3 °C to 450 °C |
| Oven Ramp Rate | 0.1–40 °C/min |
| Cooling Time | ~8 min (450 °C → 50 °C) |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Max Operating Temperature | 450 °C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| FPD Detection Limit (H₂S) | 0.02 ppm (v/v) |
| FPD Detection Limit (Thiophene) | 0.03 ppm (v/v) |
| Oven Temperature Stability | ±0.1 °C |
| Baseline Noise | ≤0.1 mV |
| Brand | ZHONGKEHUIFEN |
|---|---|
| Origin | Beijing, China |
| Model | GC-2060 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Petrochemical Industry-Specific |
| Temperature Control Range | Ambient + 3°C to 450°C |
| Oven Ramp Rate | 0.1–40°C/min |
| Cool-down Time | ~8 min (450°C → 50°C) |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Maximum Operating Temperature | 450°C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Brand | Zhongkehuifen |
|---|---|
| Origin | Beijing, China |
| Model | GC-2080 Gas Chromatograph |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-purpose fuel gas analysis |
| Column Oven Temperature Range | Ambient + 3°C to 450°C |
| Temperature Ramp Rate | 0.1–40°C/min |
| Cooling Rate | 450°C to 50°C in ~8 min |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Maximum Operating Temperature | 450°C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Oven Dimensions | 260 × 230 × 270 mm (W × D × H) |
| Weight | ~50 kg |
| External Dimensions | 560 × 540 × 520 mm (W × D × H) |
| Brand | ZHONGKEHUIFEN |
|---|---|
| Origin | Beijing, China |
| Model | GC-6890A Mine-Specific Gas Chromatograph |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Domain | Coal Mining Industry |
| Detection Configuration | TCD + Dual FID + Methane Converter |
| Sample Introduction | Automated 10-Port Valve with Manual/Ball-Bag Sampling Option |
| Column System | Dedicated Packed Columns with Triple Pre-cut Traps |
| Analysis Time | 4–8 min per injection |
| Minimum Detectable Concentration | CO & C₂H₂ ≤ 0.5 ppm |
| Temperature Control Range | Oven, Detector, and Converter up to 400 °C |
| Power Supply | AC 220 V ±10%, 50 Hz, ≤2500 W |
| TCD Sensitivity | ≥5000 mV·mL/mg |
| FID Detection Limit | ≤1.0×10⁻¹¹ g/s |
| System Precision | ≤1% RSD |
| Brand | Zhongkehuifen |
|---|---|
| Origin | Beijing, China |
| Model | GC-7820 Dedicated Gas Analysis System |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | High-Purity Gas Analysis |
| Temperature Control Range | Ambient + 3 °C to 450 °C |
| Oven Ramp Rate | 0.1–40 °C/min |
| Cooling Rate | ~8 min (450 °C to 50 °C) |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Maximum Operating Temperature | 450 °C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Configuration | Multidimensional GC with Dual-10-Port Valves, Dual-6-Port Valves, Four Analytical Columns (including Two Pre-columns), Triple Detectors (Dual TCD + FID) |
| Data Interface | Digital Output via Ethernet |
| Software | Dedicated Tri-Channel Workstation (Windows 2000/XP/8 Compatible) |
| Compliance Context | Designed for GLP-compliant laboratory environments |
| Brand | Zhongkehuifen |
|---|---|
| Origin | Beijing, China |
| Model | GC-7820 Dedicated Gas Chromatograph for Automotive Gasoline |
| Instrument Type | Laboratory Gas Chromatograph |
| Temperature Control Range | Ambient + 3 °C to 450 °C |
| Oven Ramp Rate | 0.1–40 °C/min |
| Cooling Rate | ~8 min (450 °C to 50 °C) |
| Carrier Gas Flow Range | 0–1200 mL/min |
| Carrier Gas Pressure Range | 0–970 kPa |
| Injector Max Temp | 450 °C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Brand | Zhongkehuifen |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GC-7820 Dedicated Water Quality Gas Chromatograph |
| Instrument Type | Laboratory-Based Water Quality Analyzer |
| Operating Display | 192×64 Dot-Matrix LCD with Chinese/English Interface |
| Temperature Control Range | Ambient +3 °C to 450 °C (0.1 °C increment, ±0.1 °C accuracy) |
| Programmable Temperature Ramp | 16-stage, 0.1–40 °C/min |
| Detector Options | FID, TCD, ECD, FPD, NPD |
| ECD Detection Limit | ≤1×10⁻¹⁴ g/mL (γ-HCH) |
| FID Detection Limit | <2×10⁻¹² g/s (n-hexadecane) |
| Linearity | >10⁴ (ECD), >10⁷ (FID) |
| Column Oven Dimensions | 300×280×180 mm |
| External Surface Temperature at 300 °C Operation | ≤40 °C |
| Communication Interface | Ethernet (IEEE 802.3) |
| Dimensions (W×D×H) | 660×560×480 mm |
| Brand | ZHONGKEHUIFEN |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | GC-7820 Fully Automated Coal Mine–Specific Gas Chromatograph |
| Instrument Type | Online Gas Chromatograph |
| Application Field | Coal Mining Industry |
| Temperature Control Range | Ambient + 3 °C to 450 °C |
| Oven Ramp Rate | 0.1–40 °C/min |
| Cooling Rate | ~8 min (450 °C → 50 °C) |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Maximum Operating Temperature | 450 °C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Brand | Zhongkehuifen |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | GC-7820 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | Ambient + 3 °C to 450 °C |
| Oven Ramp Rate | 0.1–40 °C/min |
| Oven Cooling Time | ~8 min (450 °C → 50 °C) |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Maximum Operating Temperature | 450 °C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Brand | ZHONGKEHUIFEN |
|---|---|
| Origin | Beijing, China |
| Model | GC-7820 Helium Ionization Gas Chromatograph |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose High-Purity Gas Analysis |
| Oven Temperature Range | Ambient + 3°C to 450°C |
| Ramp Rate | 0.1–40°C/min |
| Cool-down Time | ~8 min (450°C → 50°C) |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Maximum Operating Temperature | 450°C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Brand | ZHONGKEHUIFEN |
|---|---|
| Origin | Beijing, China |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Environmental Monitoring (Water Quality) |
| Temperature Control Range | Ambient + 3°C to 450°C |
| Oven Ramp Rate | 0.1–40°C/min |
| Cool-down Time | ~8 min (450°C → 50°C) |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Maximum Operating Temperature | 450°C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Brand | ZHONGKEHUIFEN |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | GC-7820 LPG Analysis Dedicated Gas Chromatograph |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-purpose with LPG-specific configuration |
| Temperature Control Range | Ambient + 3°C to 450°C |
| Oven Ramp Rate | 0.1–40°C/min |
| Cooling Rate | ~8 minutes (450°C → 50°C) |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Maximum Operating Temperature | 450°C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Brand | ZHONGKEHUIFEN |
|---|---|
| Origin | Beijing, China |
| Model | GC-7820 Methane and Total Hydrocarbons-Specific Gas Chromatograph |
| Instrument Type | Laboratory Gas Chromatograph |
| Temperature Control Range | Ambient + 3 °C to 450 °C |
| Oven Ramp Rate | 0.1–40 °C/min |
| Cooling Rate | ~8 min (450 °C → 50 °C) |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Max Operating Temperature | 450 °C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Brand | Zhongkehuifen |
|---|---|
| Origin | Beijing, China |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Power Industry (Transformer Oil Dissolved Gas Analysis) |
| Temperature Control Range | Ambient + 3 °C to 450 °C |
| Oven Ramp Rate | 0.1–40 °C/min |
| Cooling Rate | ~8 min (450 °C → 50 °C) |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Maximum Operating Temperature | 450 °C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Detector | TCD (with automatic bridge current cutoff on carrier gas failure) |
| Column | Dedicated anti-fouling composite column for transformer oil analysis |
| Data Interface | Ethernet-enabled, remote control & diagnostics supported |
| Display | 5.7-inch LCD, bilingual (English/Chinese), 13-line interface |
| Self-Diagnostic System | Comprehensive power-on diagnostics, fault code display, power-loss parameter retention, keypad lock, and EMI suppression |
| Brand | Zhongkehuifen |
|---|---|
| Origin | Shandong, China |
| Model | GCS-90 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Petroleum & Petrochemical Industry |
| Temperature Control Range | Ambient +5°C to 450°C |
| Max. Ramp Rate | 80°C/min |
| Cooling Rate | 450°C to 50°C in <5 min |
| Carrier Gas Flow Range & Control | 0–1000 mL/min, control resolution 0.01 mL/min |
| Carrier Gas Pressure Range & Control | 0–100 psi, control resolution 0.001 psi |
| Injector Max. Operating Temperature | 450°C |
| Injector Pressure Setting Range | 0–100 psi |
| Injector Total Flow Setting Range | 0–1000 mL/min |
| Detector | Flame Photometric Detector (FPD) |
| Sulfur LOD (COS) | 0.02 ppm |
| Dynamic Range | 10³ |
| Power Supply | 220 V, 50 Hz |
| Ambient Operating Conditions | 15–35°C, 5–95% RH |
| Temperature Setpoint Accuracy | ±0.01°C |
| Max. Programmable Temperature Steps | 16 (expandable) |
| Column Configuration | Multi-valve, multi-column, center-cutting GC architecture |
| Data Interface | 10/100M adaptive Ethernet with embedded TCP/IP stack |
| Display | 7-inch resistive touchscreen LCD (bilingual UI: English/Chinese) |
| Software | Dedicated sulfur-species workstation supporting up to 253 GC units, Modbus RTU server for DCS integration |
| Fluidic Path | All-PEEK flow path with passivated surfaces and zero-dead-volume fittings |
| Brand | ZHONGKEHUIFEN |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HF-900 |
| Instrument Type | Benchtop Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | Ambient + 3°C to 450°C |
| Oven Ramp Rate | 0.1–40°C/min |
| Oven Cool-Down Time | ~8 min (450°C → 50°C) |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Maximum Operating Temperature | 450°C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Brand | Zhongkehuifen |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HF-901 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-purpose |
| Oven Temperature Range | 4°C to 450°C |
| Oven Ramp Rate | 0.1–80°C/min |
| Oven Cool-down Time | ~6 min (450°C → 50°C) |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Maximum Operating Temperature | 450°C |
| Injector Pressure Setpoint Range | 0–970 kPa |
| Injector Total Flow Setpoint Range | 0–1200 mL/min |
| Brand | ZHONGKEHUIFEN |
|---|---|
| Origin | Beijing, China |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Universal (Petroleum Refining & Fuel Quality Control) |
| Oven Temperature Range | Ambient + 5 °C to 450 °C |
| Maximum Ramp Rate | 0.1–80 °C/min |
| Cooling Rate | 450 °C → 50 °C in ≤6 min |
| Carrier Gas Flow Range | 0–1200 mL/min |
| Carrier Gas Pressure Range | 0–970 kPa |
| Injector Max Temp | 450 °C |
| Injector Pressure Setpoint Range | 0–970 kPa |
| Injector Total Flow Setpoint Range | 0–1200 mL/min |
| Power Supply | 220 V, 50 Hz |
| Operating Ambient | 15–35 °C, 5–95% RH |
| Column Oven Dimensions | 280 × 300 × 170 mm |
| Max Run Time | 999.99 min |
| Programmable Temperature Steps | 16 |
| Detector | FID (Hydrogen Flame Ionization) |
| FID Sensitivity | <5 pg C/s (n-hexadecane) |
| FID Linear Dynamic Range | 10⁷ (±10%) |
| FID Data Acquisition Rate | 20 Hz |
| Valve Options | Motorized 4-/6-/10-port valves with electronic pressure/flow control module |
| Injector Types | Packed-column & split/splitless capillary injectors |