Chemical Analysis Instruments
Filter
Showing 6091–6120 of 10742 results
| Brand | Narishige |
|---|---|
| Origin | Japan |
| Model | NMN-21 |
| Minimum Adjustment Resolution | 1 µm |
| Coarse Travel (X/Y/Z) | 15 mm each axis |
| Fine Travel (X/Y/Z) | 6 mm each axis (via full-turn knob), 250 µm per full turn |
| Dimensions (W×D×H) | 110 × 170 × 105 mm |
| Weight | 930 g |
| Mounting Compatibility | UST-2 solid universal joint, GJ-12 magnetic base, AP-13-3 clamp holder, H-13 electric joystick, MHW-4-1 hydraulic manipulator interface |
| Accessories Included | UST-2 universal joint, mounting platform, H-13 electric joystick, hex wrench |
| Brand | NARISHIGE |
|---|---|
| Origin | Japan |
| Model | NMN-25 |
| Type | Manual Three-Axis Micromanipulator for Electrophysiology |
| Motion Range (X/Y/Z) | Coarse 15 mm / Fine 6 mm (Z), Fine 6 mm (X), Fine 6 mm (Y) |
| Fine Adjustment Resolution | 250 µm per full rotation |
| Dimensions (W×D×H) | 155 × 60 × 100 mm |
| Weight | 600 g |
| Mounting Interface | Universal H-12 Motorized Handle Compatible |
| Vibration Isolation | Optimized for integration with optical tables and active/passive isolation platforms |
| Compliance | Designed for GLP-compliant electrophysiology labs |
| Brand | NARISHIGE |
|---|---|
| Origin | Japan |
| Model | PC-100 |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Power Consumption | ~70 W |
| Heating Element | Kanthal wire, max. 2.5 V |
| Pulling Force | ≈25 g × 2 (light) or ≈100 g × 2 (heavy) |
| Dimensions | 205 × 190 × 185 mm (W × D × H) |
| Weight | 3.45 kg |
| Tip Diameter Range | down to 1 µm |
| Capillary Compatibility | φ1 mm × 90 mm glass capillaries |
| Brand | NARISHIGE |
|---|---|
| Origin | Japan |
| Model | UM-1F, UM-1FC |
| Fine Adjustment Range (UM-1F) | 20 mm (X-axis), 250 µm per revolution |
| Coarse + Fine Adjustment Range (UM-1FC) | 14 mm coarse + 6 mm fine (X-axis), 250 µm per revolution |
| Dimensions (UM-1F) | 58 mm (W) × 23 mm (D) × 60 mm (H) |
| Weight | 78 g |
| Dimensions (UM-1FC) | 80 mm (W) × 23 mm (D) × 60 mm (H) |
| Weight | 92 g |
| Brand | NARISHIGE |
|---|---|
| Origin | Japan |
| Model | UM-3C, UMM-3C |
| Gross Movement Range (UM-3C) | X±10 mm, Y±10 mm, Z±10 mm |
| Gross Movement Range (UMM-3C) | X±15 mm, Y±15 mm, Z±15 mm |
| Rotation | Manual 360° continuous |
| Mounting Shaft Diameter (UM-3C) | 10 mm |
| Mounting Shaft Diameter (UMM-3C) | 12 mm |
| Compatible Magnetic Stands | GJ-1 (UM-3C), GJ-8 (UMM-3C) |
| Dimensions (UM-3C) | 120 × 60 × 95 mm |
| Weight (UM-3C) | 235 g |
| Dimensions (UMM-3C) | 145 × 75 × 130 mm |
| Weight (UMM-3C) | 475 g |
| Brand | NARISHIGE |
|---|---|
| Origin | Japan |
| Model | UMM-3FC |
| Mounting Rod Diameter | 12 mm |
| Travel Range (Coarse) | X/Y/Z ±24 mm |
| Travel Range (Fine) | X/Y/Z ±6 mm |
| Fine Adjustment per Full Knob Rotation | 250 µm |
| Integrated Rotation Mechanism | Yes |
| Dimensions (W×D×H) | 143 × 92 × 158 mm |
| Weight | 510 g |
| Compatible Magnetic Base | GJ-8 (sold separately) |
| Brand | National Innovation Scientific Instruments |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | SuperXAFS M9000 |
| Price Range | USD 560,000 – 1,400,000 |
| Energy Range | 4.5–20 keV (upgradable to 25 keV) |
| Photon Flux at Sample | ≥4×10⁶ photons/s @ 7–9 keV |
| Energy Resolution | 0.5–1.5 eV @ 7–9 keV |
| Energy Reproducibility | ≤30 meV over 24 h |
| Minimum Energy Step Size | 0.1 eV |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (PRC) |
| Models | EasyPeak™ Au Colloidal Sol, EasyPeak™ Ag Colloidal Sol |
| Price Range | USD 7,000 – 14,000 |
| Instrument Category | SERS Enhancement Reagents (Consumable/Accessory for Raman Spectrometers) |
| Spectral Range | Not Applicable (Substrate-Level Material) |
| Spectral Resolution | Not Applicable |
| Spatial Resolution | Not Applicable |
| Minimum Wavenumber | Not Applicable |
| Spectral Reproducibility | Not Applicable |
| Brand | LANScientific |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic Laboratory X-ray Spectrometer |
| Model | NatureXAS 1500 |
| Pricing | Upon Request |
| Brand | LANScientific |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic Laboratory-scale XAFS Instrument |
| Model | NatureXAS 2500 |
| Pricing | Available Upon Request |
| Brand | Hefei Kejing |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic |
| Model | Nb Foil |
| Price Range | USD 0.15–1,500 (FOB) |
| Brand | HUIFEN Instrument |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | NBGC-60 |
| Instrument Type | Online Gas Chromatograph |
| Application Field | Environmental Monitoring |
| Brand | NC Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | EA-IRMS-iRIS |
| Pricing | Upon Request |
| Brand | NC Technologies |
|---|---|
| Origin | Italy |
| Model | ECS 4010 |
| Analysis Principle | High-Temperature Catalytic Combustion (Dumas Method) |
| Elements Determined | C, H, N, S (optional O) |
| Detection Method | Thermal Conductivity Detection (TCD) |
| Chromatographic Separation | Isothermal GC column (30–110 °C) |
| Automation Level | Fully Automated with Microprocessor Control |
| Sample Introduction | Pneumatic or Zero-Blank Electric Autosampler |
| Isotope Ratio Compatibility | Yes (for δ¹³C, δ¹⁵N, δ³⁴S, etc.) |
| Software | PC-based acquisition and reporting suite with audit trail capability |
| Compliance Support | Designed for GLP/GMP environments |
| Brand | NC Technologies |
|---|---|
| Origin | Italy |
| Model | ECS 4010 |
| Analysis Principle | High-Temperature Catalytic Combustion (Dumas Method) |
| Elements Measured | C, H, N, S (optional O) |
| Detection | Thermal Conductivity Detector (TCD), self-calibrating, reference-gas-free |
| Chromatographic Separation | Isothermal GC column (30–110 °C) |
| Automation Level | Fully automated microprocessor-controlled system with PC integration |
| Sample Introduction | Pneumatic and Zero-Blank electric autosamplers |
| Isotope Ratio Compatibility | Yes (MS-coupling enabled) |
| Compliance Framework | Designed for GLP/GMP environments |
| Brand | NC Technologies |
|---|---|
| Origin | Italy |
| Model | ECS 4010 Classic CHNS-O Elemental Analyzer |
| Detection Principle | Flash Combustion coupled with Gas Chromatographic Separation |
| Elements Analyzed | C, H, N, S, O |
| Detection Range | 200 ppm – 100% |
| Sample Mass | 0.01–100 mg (matrix-dependent) |
| Accuracy | < 0.2% (vs. certified reference materials) |
| Precision | < 0.1% RSD (vs. certified reference materials) |
| Column Temperature Control | 30–110 °C (user-programmable) |
| Oxidation Reactor Temp | 800–1100 °C |
| Reduction Reactor Temp | 600–1100 °C |
| Analysis Time | ~15 min (CHNS), ~3 min (CN only, 2-m column) |
| Detector | Thermal Conductivity Detector (TCD) |
| LOQ | 1–5 µg |
| Auto-samplers | Pneumatic (up to 147 positions), Electronic (32/50/100 positions), Manual |
| Software | EAS CLARITY v.x.x (Windows OS) |
| Gas Requirements | He (99.999%, 3–5 bar), O₂ (99.999%, 3–5 bar), Oil-free Dry Compressed Air |
| Dimensions | 760 × 350 × 700 mm (L×W×H) |
| Power | 230 VAC ±10%, 1–10 A |
| Brand | NC Technologies |
|---|---|
| Origin | Italy |
| Model | ECS 4024 Classic CHNS-O Elemental Analyzer |
| Detection Principle | Flash Combustion coupled with Gas Chromatographic Separation |
| Elements Analyzed | C, H, N, S, O |
| Detection Range | 200 ppm – 100% |
| Sample Mass | 0.01–100 mg (matrix-dependent) |
| Accuracy | < 0.2% (vs. certified reference materials) |
| Precision | < 0.1% RSD (vs. certified reference materials) |
| Combustion Furnace Temperature | 800–1100 °C |
| GC Column Temperature Range | 30–110 °C |
| TCD Limit of Quantification | 1–5 µg |
| Analysis Time | 15 min (CHNS), 3 min (CN, using 2-m GC column) |
| Auto-samplers | Pneumatic (up to 147 positions), Electronic (32/50/100 positions), Manual |
| Software | EAS CLARITY for Windows |
| Gas Requirements | He (99.999%, 3–5 bar), O₂ (99.999%, 3–5 bar), Oil-free dry compressed air |
| Dimensions | 760 × 350 × 700 mm (L×W×H) |
| Power Supply | 230 VAC ±10%, 1–10 A |
| Brand | NC Technologies |
|---|---|
| Origin | Italy |
| Model | ECS 4024 |
| Analysis Principle | High-Temperature Catalytic Combustion (Dumas Method) |
| Elements Determined | C, H, N, S (O optional) |
| Detection Method | Thermal Conductivity Detection (TCD) |
| Gas Separation | Isothermal Chromatographic Column (30–110 °C) |
| Automation Level | Semi-Automatic |
| Software Interface | PC-Connected Dedicated Data Acquisition & Processing Software |
| Isotope Compatibility | Yes (via external MS coupling) |
| Sample Type | Homogeneous Solid or Liquid Organic Samples (Micro-Weighing Compatible) |
| Brand | NC Technologies |
|---|---|
| Origin | Italy |
| Model | ECS 4024 |
| Analysis Principle | High-Temperature Catalytic Combustion (Dumas Method) |
| Elements Determined | C, H, N, S (O optional) |
| Detection Method | Thermal Conductivity Detection (TCD) |
| Chromatographic Separation | Isothermal GC column (30–110 °C) |
| Automation Level | Semi-automatic |
| Software Interface | PC-based dedicated acquisition and reporting software |
| Isotope Compatibility | Compatible with IRMS (Isotope Ratio Mass Spectrometry) coupling |
| Sample Type | Homogeneous solid or liquid organic samples (micro-weighing capable) |
| Regulatory Alignment | Designed for GLP-compliant workflows |
| Brand | NC Technologies |
|---|---|
| Origin | Italy |
| Model | ECS 8020 |
| Analysis Principle | High-Temperature Catalytic Combustion (Dumas Method) |
| Elements Measured | C, H, N, S (O optional) |
| Detection Method | Thermal Conductivity Detection (TCD) |
| Chromatographic Separation | Isothermal GC column (30–110 °C) |
| Automation Level | Fully automated with microprocessor control and PC integration |
| Sample Introduction Options | Manual, Pneumatic, Electric Zero-Blank autosampler |
| Detector Features | Reference-gas-free TCD with auto-calibration |
| Interface Capability | IDMicro EA port for stable isotope ratio mass spectrometry (IRMS) coupling |
| Compliance Context | Designed for GLP/GMP-aligned workflows |
| Brand | NC Technologies |
|---|---|
| Origin | Italy |
| Model | ECS 8020 CHNS-O Organic Elemental Analyzer |
| Measurement Principle | Dumas combustion coupled with gas chromatographic separation and thermal conductivity detection (TCD) |
| Elemental Modes | CHNS, CHN, CN, CNS, O |
| Sample Types | Solid and liquid |
| Sample Weight Range | C/H/N/S: 0.002–20 mg |
| O | 0.002–2 mg |
| Analysis Time | CHN: 5 min |
| CHNS | 10–25 min |
| O | 4 min |
| Accuracy | <0.2% (certified reference materials, purity >99.9%) |
| Precision (RSD) | <0.1% |
| Dual Combustion Furnaces | Max. 1100 °C each |
| Separation Oven Temp. | Up to 110 °C |
| Carrier Gas | Helium |
| Oxygen Delivery | Integrated mass-flow controlled O₂ dosing |
| GC Column Length | 0.8–4 m |
| Detector | High-sensitivity TCD, reference-gas-free operation |
| Autosamplers | Pneumatic (147 positions), electronic (32/50/100 positions), manual |
| Software | EAS Clarity v.x.x with linear/quadratic/cubic calibration, active recalibration, audit trail, GLP-compliant data handling |
| Compliance | Designed for ISO 17025, ASTM D5291, ASTM D7622, USP <28>, EN 15407, and FDA 21 CFR Part 11-ready configurations |
| Brand | NC Technologies |
|---|---|
| Origin | Italy |
| Model | ECS 8020 |
| Analysis Principle | High-Temperature Catalytic Combustion (Dumas Method) |
| Elements Determined | C, H, N, S (O optional) |
| Detection Method | Thermal Conductivity Detection (TCD) |
| Chromatographic Separation | Isothermal GC column (30–110 °C) |
| Automation Level | Fully automated with microprocessor control and PC integration |
| Sample Introduction Options | Manual, Pneumatic, Motorized Zero-Blank Autosampler |
| Detector Features | Reference-gas-free TCD with auto-calibration |
| Software Interface | Dedicated Windows-based acquisition and reporting software with audit trail capability |
| Compliance Support | Designed for GLP/GMP environments |
| Isotope Interface | Integrated IDMicro EA port for coupling to isotope ratio mass spectrometers (IRMS) |
| Power & Gas Management | Standby mode reduces carrier gas consumption (He or Ar), energy use, and idle time |
| Brand | NC Technologies |
|---|---|
| Origin | Italy |
| Model | ECS 8020 |
| Instrument Type | CHNSO Elemental Analyzer |
| Analysis Principle | Dumas Combustion Method |
| Measurable Elements | C, H, N, S, O |
| Sample Throughput | Up to 147 samples (pneumatic autosampler) |
| Analysis Time | C/N: 5 min |
| C/H/N | 8 min |
| C/H/N/S | 13–25 min |
| O | 4 min |
| Measurement Range | C: 0.002–20 mg |
| H | 0.002–5 mg |
| N | 0.002–2 mg |
| S | 0.002–6 mg |
| O | 0.002–2 mg |
| Accuracy | <0.2% (certified reference materials, purity >99.9%) |
| Precision | <0.1% RSD (certified reference materials, purity >99.9%) |
| Detection Sensitivity | <0.3% |
| Furnace Temperature | Dual-zone combustion furnace, up to 1100 °C per zone |
| Separation Oven Temp | Up to 110 °C |
| Carrier Gas | Helium (99.999%), 3–5 bar |
| Oxygen Supply | High-purity O₂ (99.999%), 3–5 bar |
| Auxiliary Gas | Oil-free compressed air |
| GC Column | 0.8–4 m packed capillary column |
| Detector | Self-calibrating high-sensitivity TCD |
| Software | EAS Clarity v5.x with linear, quadratic, and cubic calibration algorithms |
| Sample Form | Solid or liquid |
| Sample Mass | 0.1–500 mg (up to 1000 mg for soil matrices) |
| Sample Containers | High-purity tin or silver crucibles |
| Power Supply | 230 V, 50/60 Hz, 5 A, 1100 W |
| Dimensions | 81 × 50 × 37 cm |
| Weight | 68 kg |
| Brand | NC Technologies |
|---|---|
| Origin | Italy |
| Model | ECS 8022 |
| Measured Elements | C, N |
| Sample Forms | Solid and Liquid |
| Detection Principle | Dumas Combustion Coupled with Gas Chromatography–Thermal Conductivity Detection (GC-TCD) |
| Measurement Range | C/N: 0.002–20 mg |
| Accuracy | <0.2% (vs. certified reference materials, purity >99.9%) |
| Precision | <0.1% RSD (vs. certified reference materials, purity >99.9%) |
| Analysis Time | ~5 min per CN determination |
| Furnace System | Dual-zone high-temperature combustion furnaces (up to 1100 °C each) |
| Separation Column | 3 m GC column |
| Detector | Self-calibrating high-resolution TCD (no reference gas required) |
| Carrier Gas | Ultra-high-purity helium (99.999%, 3–5 bar) |
| Oxidant | Ultra-high-purity oxygen (99.999%, 3–5 bar) |
| Autosamplers | Pneumatic (147-position), Electromechanical (32/50/100-position), Manual |
| Software | EAS Clarity™ with linear/quadratic/cubic calibration, real-time process monitoring, catalyst consumption tracking, and audit-ready data logging |
| Compliance | Designed for GLP/GMP environments |
| Dimensions | 81 × 50 × 37 cm |
| Weight | 68 kg |
| Power | 230 V, 50/60 Hz, 5 A, 1100 W max |
| Brand | NC Technologies |
|---|---|
| Origin | Italy |
| Model | ECS 8024 |
| Measurable Elements | C, N |
| Sample Types | Solid (e.g., soil, sediment, plant tissue) and liquid |
| Detection Principle | Dumas combustion coupled with gas chromatographic separation and thermal conductivity detection (TCD) |
| Measurement Range | C/N: 0.002–20 mg |
| Accuracy | <0.2% (certified reference materials, purity >99.9%) |
| Precision | <0.1% RSD (n=10, CRM) |
| Analysis Time | ~5 min per CN determination |
| Furnace System | Dual-zone high-temperature combustion furnaces (up to 1100 °C each) |
| Separation Column | 3 m GC column |
| Detector | Self-calibrating high-resolution TCD (no reference gas required) |
| Gas Requirements | Helium (99.999%, 3–5 bar), Oxygen (99.999%, 3–5 bar), oil-free compressed air |
| Auto-sampling Options | Pneumatic (147-position), Electronic (32/50/100-position), or manual |
| Software | EAS Clarity v5.x with GLP-compliant audit trail, calibration curve fitting (linear, quadratic, cubic), and method validation tools |
| Compliance | Designed to support ISO 13879, ASTM D5373, EPA Method 9060A, and USP <231> for elemental carbon/nitrogen quantification in environmental matrices |
| Dimensions | 81 × 50 × 37 cm |
| Weight | 68 kg |
| Power | 230 V, 50/60 Hz, 5 A, 1100 W max |
| Brand | NC Technologies |
|---|---|
| Origin | Italy |
| Model | ECS 8024 Soil-Specific CN Elemental Analyzer |
| Measurement Principle | Dumas combustion coupled with gas chromatographic separation |
| Detection | High-resolution thermal conductivity detector (TCD) |
| Sample Throughput | Up to 147 positions (pneumatic/electronic/manual samplers) |
| Analysis Time | ~5 min per CN determination |
| Quantification Range | 0.002–20 mg C and N per sample |
| Accuracy | <0.2% RSD (relative standard deviation) |
| Precision | <0.1% RSD |
| Dual-Furnace System | Left & right furnaces, up to 1100 °C each |
| Separation Oven Temperature | Up to 110 °C |
| Carrier Gas | Helium |
| Oxidant | Automated oxygen dosing |
| GC Column | 3 m packed capillary column |
| Software | EAS Clarity™ with linear/quad/cubic calibration, active recalibration, audit trail, and GLP-compliant data handling |
| Compliance | Designed for ASTM D5373, ISO 13878, USP <281>, and EN 15936 workflows |
| Brand | NC Technologies |
|---|---|
| Origin | Italy |
| Model | ECS 8024 NC SOIL SPECIAL |
| Detection Principle | High-Temperature Catalytic Combustion (Dumas Method) |
| Elements Measured | Total Carbon (TC), Total Nitrogen (TN) |
| Optional Coupling | TIC DISCOVER for Total Inorganic Carbon (TIC) |
| Detector Type | Thermal Conductivity Detector (TCD) |
| Column Temperature Range | 30–110 °C |
| Sample Types | Soils, Fertilizers, Sludges, Sediments, Plant Tissues |
| Automation Level | Fully Automated with Motorized/Pneumatic/Manual Sampler Options |
| Software Control | PC-based with Touchscreen Interface |
| Compliance Ready | Supports GLP/GMP audit trails, ASTM D5373, ISO 10694, USP <281>, EN 15936 |
| Brand | NC Technologies |
|---|---|
| Origin | Italy |
| Model | ECS 8040 |
| Analysis Principle | High-Temperature Catalytic Combustion (Dumas Method) |
| Elements Measured | C, H, N, S (O optional) |
| Detection Method | Thermal Conductivity Detection (TCD) |
| Gas Separation | Isothermal Chromatographic Column (30–110 °C) |
| Automation Level | Fully Automated with Microprocessor Control and PC Integration |
| Sample Introduction Options | Manual, Pneumatic, Motorized Zero-Blank Autosampler |
| Compliance Ready | ASTM D5291, ISO 16968, USP <281>, EN 15104, DIN 51725 |
| Software Features | Real-Time Parameter Monitoring, Catalyst Life Tracking, Leak Detection, Audit Trail Logging (21 CFR Part 11–compliant mode available) |
| Brand | NC Technologies |
|---|---|
| Origin | Italy |
| Model | ECS 8040 CHNS-O Organic Elemental Analyzer |
| Measurement Principle | Dumas combustion coupled with gas chromatographic separation and thermal conductivity detection (TCD) |
| Elemental Range | C, H, N, S, O (0.002–20 mg for C/H/N |
| Accuracy | <0.2% (certified reference materials, purity >99.9%) |
| Precision | <0.1% RSD (certified reference materials, purity >99.9%) |
| Combustion Temperature | up to 1100 °C |
| Reduction Oven Temperature | up to 110 °C |
| Carrier Gas | Helium |
| Oxygen Delivery | Automated dosing with electronic flow control |
| GC Column | 0.8–4 m capillary or packed GC column (dedicated for CO₂, H₂O, N₂, SO₂ separation) |
| Detector | High-sensitivity, reference-free TCD |
| Sample Throughput | Up to 147 positions (pneumatic autosampler), 32/50/100 positions (electronic autosampler), manual option available |
| User Interface | Integrated touchscreen display |
| Software | EAS Clarity™ with linear/quadratic/cubic calibration, active recalibration, audit trail, and GLP-compliant data handling |
| Power Management | Standby mode for reduced He/O₂ consumption and energy use |
| Compliance | Designed to support ASTM D5291, ISO 16968, USP <28>, and FDA 21 CFR Part 11 requirements (when configured with full audit trail and electronic signature modules) |
| Brand | NC Technologies |
|---|---|
| Origin | Italy |
| Model | ECS 8040 |
| Analysis Principle | High-Temperature Catalytic Combustion (Dumas Method) |
| Elements Measured | C, H, N, S, O (O optional) |
| Detection Method | Thermal Conductivity Detection (TCD) |
| Gas Separation | Isothermal Capillary Chromatography (30–110 °C) |
| Automation Level | Fully Automated with Microprocessor Control & PC Integration |
| Sample Introduction Options | Manual, Pneumatic, Motorized Zero-Blank Autosampler |
| Detector Configuration | Dual TCD with Reference-Free Operation |
| Software | Dedicated Windows-Based Acquisition & Quantification Suite with Audit Trail Capability |
| Compliance Framework | Designed for GLP/GMP environments |
| Power Supply | 230 V AC, 50/60 Hz |
| Dimensions (W×D×H) | 700 × 650 × 550 mm |
| Weight | ~75 kg |