| Brand | PalmSens |
|---|---|
| Origin | Netherlands |
| Model | MultiPalmSens4 |
| Channel Count | 4–10 configurable channels |
| Current Range | ±30 mA |
| Current Accuracy | ≤ 0.1% of full scale |
| Potential Accuracy | 0.01% of full scale |
| Potentiostatic Range | ±10 V |
| EIS Frequency Range | 10 μHz to 1 MHz |
| ADC Resolution | 18-bit (76.3 µV potential resolution, 5 fA current resolution at 100 pA range) |
| Data Acquisition Rate | up to 150,000 points/s |
| Onboard Memory per Channel | 8 GB |
| Compliance | CE, RoHS, ISO/IEC 17025-compatible operation environment |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | UV-3200 |
| Price Range | USD 1,400–2,800 |
| Optical Design | Pseudo-Double-Beam |
| Detector | Silicon Photodiode |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.3 nm |
| Spectral Bandwidth | 1.8 nm |
| Stray Light | ≤0.03% T at 220 nm and 360 nm |
| Wavelength Repeatability | ≤0.2 nm |
| Photometric Accuracy | ±0.2% T (0–100% T), ±0.002 A (0–0.5 A), ±0.004 A (0.5–1 A) |
| Photometric Repeatability | ≤0.15% T (0–100% T), ±0.001 A (0–0.5 A), ±0.002 A (0.5–1 A) |
| Baseline Flatness | ±0.0015 A (200–1000 nm) |
| Drift | ±0.001 A/h at 500 nm |
| Noise | ±0.0005 A |
| Display | 320 × 240 LCD |
| Scan Speed Options | High/Medium/Low (up to 3800 nm/min) |
| Data Interface | USB |
| Print Interface | Parallel Port |
| Power Supply | AC 220 V/50 Hz or AC 110 V/60 Hz |
| Dimensions | 590 × 420 × 260 mm |
| Weight | 20 kg |
| Brand | MupuDa |
|---|---|
| Origin | Shanghai, China |
| Model | UV-6100 |
| Optical System | Dual-beam |
| Detector | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Spectral Bandwidth | 1.8 nm |
| Wavelength Accuracy | ±0.3 nm |
| Wavelength Repeatability | ≤0.1 nm |
| Stray Light | ≤0.03%T at 220 nm and 360 nm |
| Photometric Accuracy | ±0.002 A (0–0.5 A), ±0.004 A (0.5–1.0 A), ±0.2%T (0–100%T) |
| Photometric Repeatability | ≤0.001 A (0–0.5 A), ≤0.002 A (0.5–1.0 A), ≤0.15%T (0–100%T) |
| Baseline Drift | ±0.0003 A/h (at 500 nm, after warm-up) |
| Baseline Flatness | ±0.0005 A |
| Noise Level | 0.0003 Abs (at 500 nm) |
| Scan Speed | High/Medium/Low, up to 3800 nm/min |
| Photometric Range | –4 to +4 A, 0–200%T, 0–9999 C |
| Display | 320 × 240 dot-matrix LCD |
| Data Interface | USB port, parallel printer port |
| Power Supply | AC 220 V/50 Hz or AC 110 V/60 Hz |
| Dimensions | 590 × 420 × 260 mm |
| Weight | 26 kg |
| Brand | MVI |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Vista-IR |
| Instrument Category | Laser-Based Infrared Spectrometer |
| Instrument Type | Laboratory Benchtop System |
| Wavenumber Range | 760–4400 cm⁻¹ |
| Spatial Resolution | <10 nm |
| Spectral Resolution | <2 cm⁻¹ |
| Scan Rate | 10 spectra/sec |
| Signal-to-Noise Ratio | 100:1 |
| Brand | MYRON L |
|---|---|
| Origin | USA |
| Model | Ultrameter 6P |
| Instrument Type | Portable |
| Parameter Count | 6 |
| Measurement Accuracy | ±0.01 pH |
| pH Range | 0–14 |
| pH Resolution | 0.01 |
| pH Accuracy | ±0.01 pH |
| Calibration Solution | pH 7 buffer |
| Conductivity Range | Auto-ranging 0–9999 µS/cm, 10–200 mS/cm |
| TDS Range | 0–9999 ppm, 10–200 ppt |
| Resistivity Range | 10 kΩ·cm – 30 MΩ·cm |
| ORP Range | ±999 mV |
| Temperature Range | 0–71 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.1 °C |
| Auto Temperature Compensation | Yes (0–71 °C) |
| IP Rating | IP67 (NEMA 6) |
| Data Storage | 20 points with timestamp |
| Enclosure | Fully sealed, buoyant, submersible to 1 m |
| Brand | MYRONL |
|---|---|
| Origin | USA |
| Model | 532T1 |
| Measurement Principle | Two-electrode conductivity cell with linear TDS conversion (NaCl equivalence) |
| TDS Range | 0–50 / 0–500 / 0–5000 ppm (auto-ranging) |
| Resolution | 1 ppm (0–50 ppm), 10 ppm (0–500 ppm), 100 ppm (0–5000 ppm) |
| Accuracy | ±2% of full scale |
| Temperature Compensation | Automatic, 10–71 °C |
| pH Range | 0.0–14.0 (with replaceable pH electrode) |
| Power | 9 V alkaline battery (approx. 2,000 measurements/year) |
| Electrode Type | Maintenance-free graphite conductivity cell |
| Enclosure | IP65-rated rugged ABS housing |
| Compliance | Designed for field and lab use per ASTM D1125 and ISO 7888 guidelines for conductivity/TDS estimation |
| Brand | MyronL |
|---|---|
| Origin | USA |
| Model | EP/512M5/EP10 |
| Conductivity Ranges | 0–0.5 µS, 0–5 µS, 0–50 µS, 0–500 µS, 0–5000 µS, 0–10 mS, 0–100 mS, 0–1000 mS, 0–10,000 µS |
| Resistivity Range | 2–30 MΩ |
| Accuracy | ±2% of full scale (all ranges) |
| Automatic Temperature Compensation | 10–71 °C |
| Power | 9 V alkaline battery (≈2000 measurements/year) |
| Electrode Type | Maintenance-free conductive cell |
| Compliance | Designed for field and lab use in accordance with ASTM D1125 and ISO 7888 principles |
| Brand | MYRONL |
|---|---|
| Origin | USA |
| Model | Ultrameter 4P |
| Portability | Portable |
| Conductivity Range | 0–200 mS/cm |
| TDS Range | 0–9999 ppm |
| Resistivity Range | 10 kΩ·cm – 30 MΩ·cm |
| Salinity Range | Not applicable (dedicated conductivity/TDS/resistivity/temperature model) |
| Temperature Range | 0–71 °C |
| Accuracy | ±1% of reading |
| Minimum Conductivity Resolution | 0.01 µS/cm |
| Enclosure Rating | IP67 (NEMA 6) |
| Data Storage | 20 points with timestamp |
| Auto-Temperature Compensation | Yes (0–71 °C) |
| Electrode Design | Integrated, field-replaceable dual-cell conductivity sensor with built-in temperature probe |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | NAKE 750 |
| Price | USD 7,200 (Refurbished) |
| Instrument Type | Benchtop |
| Excitation Source | High-Energy Spark |
| Detector Type | Photomultiplier Tube (PMT) |
| Focal Length | 750 mm |
| Grating Groove Density | 2400 lines/mm |
| Wavelength Range | 120–800 nm |
| Number of Channels | Configurable (up to 32 fixed channels + 4 programmable PMT positions) |
| Operating Environment | 10–40 °C, <80% RH |
| Power Supply | 220 V AC, 16 A, 2.5 kVA |
| Dimensions (L×D×H) | 105 × 85 × 120 cm |
| Weight | 350 kg |
| Brand | Auniontech (HaoLiang) |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | Nanalysis 100 MHz |
| Operating Frequency | 100 MHz (2.35 T) |
| Magnet Type | Permanent, Cryogen-Free |
| Nuclei Support | Dual-Tuned Probes (e.g., ¹H/¹³C, ¹H/³¹P, ¹H/¹⁹F, ¹H/¹¹B, ¹⁹F/⁷Li) |
| Lock Channel | ¹H or ²H |
| Sample Format | Standard 5 mm NMR tubes |
| Resolution | <1.0 Hz (at 100 MHz) |
| Sensitivity | 220:1 (1% ethylbenzene in CDCl₃) |
| Data Formats | JCAMP-DX, Delta, ACD/Labs, TopSpin, LabVIEW, MATLAB |
| Operating Temperature | 16–28 °C |
| Power Input | 100–240 VAC, 50–60 Hz |
| Dimensions | 37.1 × 41.4 × 65.5 cm (14.6 × 16.3 × 25.8 in) |
| Weight | 84 kg |
| User Interface | Integrated touchscreen PC + remote access capability |
| Compliance | Designed for GLP-compliant environments |
| Brand | Qilin (QL) |
|---|---|
| Origin | Jiangsu, China |
| Model | QL-CS20D |
| Measurement Principle | Gas Volumetric Method (C), Iodometric Titration (S) |
| Heating System | Arc Furnace |
| Carbon Range | 0.02–6.00 wt% |
| Sulfur Range | 0.005–0.300 wt% |
| Sample Mass Options | 0.25 g / 0.5 g / 1.0 g |
| Analysis Time | 65 s (single absorption) or 85 s (dual absorption) with DL1A arc furnace |
| Compliance | GB/T 223.69–1997 (C), GB/T 223.68–1997 (S) |
| Readout | Direct digital display of mass fraction (%) with thermal printer output |
| Operating Environment | 0–40 °C, 90.658–106.658 kPa |
| Brand | Qilin (QL) |
|---|---|
| Origin | Jiangsu, China |
| Model | CS20D |
| Measurement Principle | Gas Volumetric Method (C), Iodometric Titration (S) |
| Heating System | Arc Furnace |
| Carbon Range | 0.05–6.00 wt% |
| Sulfur Range | 0.005–0.300 wt% |
| Sample Weight Options | 0.25 g / 0.5 g / 1.0 g |
| Analysis Time | 45 s (with DL1A arc furnace) |
| Readout | Direct digital display of mass fraction (%) with thermal printer output |
| Accuracy | Compliant with GB/T 223.69–1997 (C) and GB/T 223.68–1997 (S) |
| Operating Environment | 0–40 °C, 90.658–106.658 kPa |
| Brand | Qilin / QL |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | QL-HW2000 |
| Price Range | USD 7,000–14,000 (FOB) |
| Measurement Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Combustion Source | 2.5 kVA High-Frequency Induction Furnace (18–20 MHz) |
| Carbon Range | 0.00001–10.0000 wt% (extendable to 99.999 wt%) |
| Sulfur Range | 0.00001–0.5000 wt% (extendable to 99.999 wt%) |
| Sensitivity | 0.1 ppm (minimum display resolution) |
| Precision | Carbon RSD ≤ 0.5%, Sulfur RSD ≤ 1.0% |
| Analysis Time | 25–60 s (user-adjustable) |
| Compliance | GB/T 20123–2006, ISO 15350:2000 |
| Sample Weighing Accuracy | 0.0001 g (via integrated analytical balance interface) |
| Optical Detection | High-stability pyroelectric infrared detectors with narrow-band interference filters |
| Gas Handling | Precision mass flow control |
| Mechanical Drive | Aerospace-grade synchronous motor in IR absorption cell (rated >100,000 h MTBF) |
| Brand | Qilin/QL |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | QL-HW2000DH |
| Measurement Principle | Infrared Absorption Spectroscopy |
| Heating System | High-Frequency Induction Furnace |
| Carbon Range | ω(C) 0.0010–10.00 wt% |
| Sulfur Range | ω(S) 0.0005–0.500 wt% |
| Sensitivity | 0.1 ppm (as displayed reading) |
| Accuracy | Compliant with GB/T 223.69–1997 (C) and GB/T 223.68–1997 (S) |
| Analysis Time | Adjustable 20–60 s (typical: 35 s) |
| Sample Weighing | Analytical Balance (0.0001 g resolution) |
| Operating Environment | 10–30 °C, RH < 75% |
| Brand | NanoAppo |
|---|---|
| Origin | Tianjin, China |
| Model | EasyPeak |
| Type | SERS Enhancement Substrate |
| Substrate Composition | Colloidal Silver (Ag) and Colloidal Gold (Au) Nanoparticle Suspensions |
| Storage Condition | 4 °C |
| Shelf Life | Ag-based: 8 months |
| Au-based | 3.5 months |
| Detection Limit (Ag) | 3 × 10⁻⁶ mol/L (2-mercaptopyridine probe) |
| Detection Limit (Au) | 3 × 10⁻⁹ mol/L (Rhodamine 6G probe) |
| Enhancement Factor (Au) | >10⁹ |
| Compliance | Designed for ASTM E1840-23 and ISO/IEC 17025-compliant Raman workflows |
| Software Compatibility | Compatible with standard Raman spectrometer control software (e.g., Thermo Fisher OMNIC, Horiba LabSpec, Renishaw WiRE) |
| Brand | Macherey-Nagel |
|---|---|
| Origin | Germany |
| Model | NANOCOLOR® UV/VIS Spectrophotometer with Reference Detection Technology (RDT) |
| Wavelength Range | 190–1100 nm |
| Light Sources | Tungsten-halogen lamp (vis) and deuterium lamp (uv) |
| Optical System | Single-beam stabilized optics |
| Wavelength Accuracy | ±1 nm |
| Wavelength Resolution | 0.3 nm |
| Spectral Bandwidth | <4 nm |
| Absorbance Range | ±3.0 E (200–900 nm) |
| Absorbance Accuracy | ±0.005 E (0.0–0.5 E) |
| Absorbance Linearity | <0.5% at 2.0 E |
| Stray Light | <0.05% |
| Measurement Modes | Predefined test methods, absorbance, transmittance, factor, multi-wavelength, kinetics, full-spectrum scan, turbidity |
| Cuvette Compatibility | Round tubes (Ø16 mm outer / Ø14 mm inner), rectangular cuvettes (10, 20, 50 mm pathlength) |
| Data Storage | 1000 GLP-compliant measurements with audit trail |
| Display | Color backlit LCD touchscreen |
| Interface | 1× USB, 2× RS-232 (bidirectional) |
| Environmental Operating Conditions | 10–40 °C, ≤80% RH (non-condensing) |
| Power Supply | 110–240 V AC, 50/60 Hz, 60 VA |
| Dimensions (L×W×H) | 390 × 285 × 155 mm |
| Weight | 6.5 kg |
| Compliance | CE-marked per Low Voltage Directive 73/23/EEC and EMC Directive 89/336/EEC (incl. 92/31/EEC) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | NanoDrop Lite |
| Optical Design | Dual-Beam |
| Detector | Photodiode Array |
| Wavelength Range | 260–280 nm |
| Wavelength Automation | Automatic |
| Spectral Bandwidth | 0.5 nm |
| Wavelength Accuracy | ±0.2% T |
| Stray Light | 0.01% T |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | NanoDrop Eight |
| Optical Design | Dual-beam |
| Detector | CCD Array |
| Wavelength Range | 190–850 nm |
| Wavelength Automation | Fully Automatic |
| Spectral Bandwidth | ≤1.8 nm |
| Wavelength Accuracy | ±1 nm |
| Stray Light | ≤0.01% T |
| Brand | Mapada |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | NanoGenius Plus |
| Pricing | Available Upon Request |
| Brand | NanoMagnetics |
|---|---|
| Origin | United Kingdom |
| Model | LT-AFM/MFM |
| Cooling System | Cryogen-Free Closed-Cycle Cryostat |
| Temperature Range | 1.5 K – 400 K (base temperature ≤1.5 K) |
| Maximum Magnetic Field | 20 T |
| Vibration Isolation | Active + Passive Vibration-Free Design |
| Operation Mode | Fully Dry, Helium-Free |
| Sample Stage Travel (Z) | 10 mm |
| Sample Stage Travel (XY) | Ø3 mm |
| Sample Positioning Resolution | 2 µm (capacitive encoder) |
| Sample Dimensions (max) | 15 × 15 × 5 mm |
| Electrical Interface | 5-pin sample holder (1 bias + 4 auxiliary channels) |
| Environmental Compatibility | UHV-compatible, exchange-gas capable, PPMS®-integrated, Evercool®-compatible, dilution refrigerator & He-3 system adaptable |
| Brand | NanoMagnetics |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LT-SHPM/STM |
| Pricing | Available Upon Request |
| Temperature Range | 10 mK – 400 K |
| Magnetic Field Range | Up to 20 T |
| Spatial Resolution (Z) | 50–800 nm (stick-slip approach) |
| Scan Range (XY) | Ø3 mm |
| Z-Travel | 10 mm |
| Sample Dimensions | Max. 15 × 15 × 5 mm |
| Magnetic Noise Floor | 10 µT/√Hz @ 300 K, 100 nT/√Hz @ 77 K, 10 nT/√Hz @ 4 K |
| Compatibility | PPMS®, dry magnet systems, dilution refrigerators (DRs), He-3 cryostats |
| Optional Module | 3D-SHPM for vectorial magnetic field mapping |
| Brand | NanoMagnetics |
|---|---|
| Origin | United Kingdom |
| Model | mK-CFM/RAMAN |
| Temperature Range | 10 mK – 300 K |
| Magnetic Field | Up to 31 T |
| Objective | 0.82 NA, 0.95 mm Working Distance APO Cryo-Objective |
| Scan Range (300 K) | 50 × 50 × 25 µm |
| Scan Range (4 K) | 30 × 30 × 15 µm |
| Coarse Approach Range | 6 × 6 × 12 mm (XYZ), Step Size: 50–700 nm |
| Closed-Loop Encoder Resolution | 200 nm |
| Fine Scan Range (300 K) | 7.5 µm |
| Fine Scan Range (4.2 K) | 1 µm |
| Max Sample Dimensions | 10 × 10 × 5 mm |
| Sample Holder | 8-pin electrical feedthrough |
| Environmental Compatibility | Ultra-high vacuum (UHV) or purged gas atmosphere |
| Cryostat Compatibility | Compatible with standard 50 mm cold-finger dilution refrigerators and most commercial cryogenic platforms |
| Brand | NanoMagnetics |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | NV |
| Pricing | Upon Request |
| Objective NA | 0.82 (Achromatic Apochromatic, 0.95 mm clear aperture) |
| Excitation Laser | 532 nm single longitudinal mode, 10 mW |
| Operating Temperature Range | 10 mK – 300 K |
| Scan Range (at 4 K) | 30 × 30 × 15 µm |
| Detector | Avalanche Photodiode (APD) for optical readout |
| Sample Stage | 6 × 6 × 12 mm XYZ piezo nanopositioner |
| NV/QTF Sensor Stage | 4 × 4 × 6 mm XYZ nanopositioner |
| Position Sensing | Resistive sensor, 200 nm resolution |
| Controller | FPGA-based AFM/SPM controller with USB 3.0 interface |
| Real-time Processor | 32-bit, 128 MB DDR SDRAM |
| ADC | Dual-channel 16-bit @ 100 MHz |
| DAC | Dual-channel 16-bit @ 100 MHz |
| On-FPGA PID Loops | 7 independent channels |
| Piezo Driver Channels | 19-channel high-voltage piezo controller |
| Auxiliary ADC | 16-channel 24-bit @ 175 kHz |
| Scan DAC | 24-bit for XYZ raster scanning |
| High-Voltage Amplifier | Low-noise, wide-bandwidth |
| Brand | Metrohm |
|---|---|
| Origin | USA |
| Manufacturer | Metrohm AG |
| Instrument Type | Portable Handheld Raman Spectrometer |
| Spectral Range | 176–2500 cm⁻¹ |
| Excitation Wavelength | 1064 nm |
| Compliance | FDA 21 CFR Part 11, USP <858>, Ph. Eur. 2.2.48, JP 2.26, ChP 2020 Raman Spectroscopy General Chapter |
| Application Focus | GMP-compliant raw material identity testing (RMIT), incoming material verification, counterfeit detection |
| Brand | NANOSPACE |
|---|---|
| Origin | Japan |
| Model | F3012 |
| Max. Operating Pressure | 35 MPa |
| Dead Volume | 1.0 µL |
| Wetted Materials | PEEK, Ceramics |
| Control Modes | Manual, Time-Programmable (0.00–999.99 min), External TTL Trigger (Start Signal), SYSCON & PC Communication |
| Power Supply | AC 100 V ±10%, 50/60 Hz, 15 W |
| Dimensions | 120(W) × 230(H) × 491(D) mm |
| Weight | 10 kg |
| Brand | NANOSPACE |
|---|---|
| Origin | Japan |
| Model | F5600 |
| Detection Principle | Water Condensation Particle Counting (WCPC) coupled with nebulization and thermal desolvation |
| Light Source | Monochromatic Laser |
| Detection Mode | Universal, Non-UV, Non-Ionizing, Non-Electrochemical |
| Applicable Analytes | Non-volatile, non-UV-absorbing, non-ionizable, electrochemically inert, or structurally unknown compounds |
| Compliance Context | Designed for GLP-compliant laboratories |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | NS1 |
| Pricing | Available Upon Request |
| Brand | Narishige |
|---|---|
| Origin | Japan |
| Model | M-3333 |
| Dimensions (W×D×H) | 126 × 43 × 145 mm |
| Weight | 340 g |
| Coarse Motion Range (X/Y/Z) | 40 / 12 / 30 mm |
| Fine Motion Range (X) | 7 mm |
| Minimum Step Size | 10 µm |
| Maximum Step Size | 250 µm |
| Compatible Electrode Holder | H-1 |
| Drive Mechanism | X-4 Rotational X-Block |
| Construction | Compact, Low-Profile Monoblock Design |
| Brand | Narishige |
|---|---|
| Origin | Japan |
| Model | M-44 |
| Mounting Interface | Ø4 mm rod |
| Gross Adjustment Range | 22 mm |
| Pivot Motion Axis | Y-axis |
| Tilt Motion Axis | Z-axis |
| Dimensions (W×D×H) | 65 × 25 × 50 mm |
| Weight | 70 g |
| Standard Accessories | H-7C Pipette Holder, Allen Wrench |
| Brand | NARISHIGE |
|---|---|
| Origin | Japan |
| Model Variants | MTK-1-O1/O2/O3/N1/N2/N3/N4/Z1/Z2/L1/L2 |
| Drive Principle | Hydraulic |
| Axes | X, Y, Z, Rotation (θ) |
| X/Y/Z Travel (Hydraulic Fine Control) | 10 mm |
| X/Y/Z Step Resolution (Fine Button) | 250 µm (X/Y), 1000 µm (Z) |
| Minimum Increment (Fine Adjustment) | 5 µm (X/Y), 20 µm (Z) |
| Coarse Return Stroke (Manual Reset) | 50 mm |
| Pipette Tip Angular Range | 15°–40° |
| Pipette Tip-to-Anchoring Point Distance | Adjustable & Reproducible |
| Hydraulic Tubing Length | 0.6 m |
| Control Unit Dimensions (W×D×H) | 85.6 × 225–235 × 151–171 mm, ~1.9 kg |
| Driver Unit Dimensions (W×D×H) | 108–138 × 145–155 × 100–150 mm, ~820 g |