Chemical Analysis Instruments
Filter
Showing 6691–6720 of 10734 results
| Brand | Oxford Instruments |
|---|---|
| Origin | United Kingdom |
| Model | X-Pulse |
| Instrument Type | Low-Field NMR Analyzer |
| Sample Form | Liquid |
| Operating Frequency | 60 MHz |
| Data Acquisition Mode | Pulsed Fourier Transform |
| Signal-to-Noise Ratio | >180:1 |
| Spectral Resolution | <0.35 Hz |
| ¹H Quantitative Reproducibility | Excellent |
| Brand | HUIFEN Instrument |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Model | Packed Column |
| Pricing | Available Upon Request |
| Brand | NC Technologies |
|---|---|
| Origin | Italy |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Paeonia IR |
| Price Range | USD 1,400 – 140,000 |
| Brand | Paeonia Innovations |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Paeonia IR |
| Instrument Type | Online |
| Wavenumber Range | 900–1800 cm⁻¹ |
| Dimensions | 50 × 55 × 60 mm |
| Weight | 450 g |
| Response Time | 0.3 s |
| Operating Pressure | 0–5 bar |
| Operating Temperature | −15 °C to +60 °C |
| Flow Path Fitting | 1/8″ NPT or Swagelok |
| Power Supply | 5 V DC via USB-C |
| Software Platform | Windows 10 & 11 Native Application for Real-Time Data Acquisition and Instrument Control |
| Brand | Palintest |
|---|---|
| Origin | United Kingdom |
| Model | Lumiso Expert |
| Protection Rating | IP67 |
| Wavelengths | 430 nm, 465 nm, 530 nm, 575 nm, 620 nm (auto-selected per method) |
| Display | 16:9 full-color touchscreen, 800 × 480 px resolution |
| Photometric Accuracy | ±1% T |
| Wavelength Accuracy | ±2 nm |
| Memory Capacity | 1000 test records with timestamp, sample ID, operator info, dilution factor, and method metadata |
| Preloaded Calibration Curves | >100 (for chlorine, COD, ammonia-N, total phosphorus, total nitrogen, hardness, color, heavy metals, etc.) |
| Cuvette Compatibility | 12 mm and 25 mm round glass or plastic cuvettes |
| Power Supply | 6 × AA batteries (≈5000 measurements per charge) or AC adapter |
| Data Interface | Waterproof USB port compliant with USB 2.0 |
| Operating Languages | English, Chinese, Spanish, French, German, Portuguese |
| Compliance | Designed to support ISO 7027, ISO 8466-1, ASTM D1253, EPA 365.2, USP <643>, and EN ISO 6226 for photometric water analysis methods |
| Brand | Palintest |
|---|---|
| Origin | United Kingdom |
| Model | Micro 600 |
| Portability | Portable |
| Conductivity Range | 0–199.9 mS/cm |
| Detection Parameter | Single-parameter (Conductivity & Temperature) |
| Electrode Constants | K = 0.1, 1.0, 10.0 (user-selectable via keypad) |
| Calibration Points | Up to 5 points (1 per range) |
| Temperature Range | 0–80.0 °C |
| Resolution | 0.1 °C (temperature), 0.05% FS (conductivity) |
| Accuracy | ±1% FS + 1 LSD (conductivity), ±0.5 °C (temperature) |
| Temp. Compensation | Automatic or manual (0–80 °C), adjustable temperature coefficient (0.0–3.0 %/°C), reference temp. selectable (20.0–25.0 °C) |
| Display | Monochrome LCD |
| Power | 4 × AAA alkaline batteries (>100 h operation) |
| Dimensions | 140 × 70 × 35 mm |
| Weight | 200 g |
| Brand | Palintest |
|---|---|
| Origin | United Kingdom |
| Model | Micro 600 pH |
| Instrument Type | Portable |
| Parameter Types | Dual (pH + Temperature) |
| pH Measurement Range | 0.00–14.00 pH |
| pH Resolution | 0.01 pH |
| pH Accuracy | ±0.01 pH |
| pH Calibration Points | 1–5 points |
| Recognized Buffers | NIST-traceable (pH 1.68, 4.01, 6.86, 9.18, 12.45) and USP/ASTM (pH 1.68, 4.01, 7.00, 10.01, 12.45) |
| Slope Acceptance Range | 80–120% |
| Temperature Range | 0.0–100.0 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.5 °C |
| Temperature Compensation | Automatic or Manual (0–100 °C) |
| mV Range | −1000 to +1000 mV |
| mV Resolution | 1 mV |
| mV Accuracy | ±2 mV |
| Display | Single-line LCD |
| Power | 4 × AAA alkaline batteries (>100 h operation) |
| Dimensions | 140 × 70 × 35 mm |
| Weight | 200 g |
| Auto-off | After 17 min inactivity |
| Brand | Palintest |
|---|---|
| Origin | United Kingdom |
| Model | Micro 600 |
| Portability | Portable |
| TDS Range | 0–99.9 g/L |
| Resolution | 0.01/0.1/1 mg/L and 0.01/0.1/1 g/L |
| Accuracy | ±1% FS |
| Temperature Range | 0–100.0 °C |
| Temp. Compensation | Automatic or Manual (0–80 °C) |
| Cell Constant Options | 0.1, 1.0, 10.0 cm⁻¹ |
| TDS Conversion Factor | 0.40–1.00 (default 0.67) |
| Calibration | Up to 5-point manual per range |
| Display | Single-line LCD |
| Power | 4 × AAA alkaline batteries (>100 h life) |
| Dimensions | 140 × 70 × 35 mm |
| Weight | 200 g |
| Brand | Palintest |
|---|---|
| Origin | United Kingdom |
| Model | Micro 800 |
| Portability | Portable |
| Conductivity Range | 0–200 mS/cm |
| TDS Range | 0–20 g/L |
| Temperature Range | −10 to 110 °C |
| pH Range | −2.00 to 16.00 |
| pH Resolution | 0.01 |
| pH Accuracy | ±0.01 |
| Conductivity Resolution | up to 0.01 µS/cm |
| Conductivity Accuracy | ±1% FS |
| TDS Resolution | up to 0.01 mg/L |
| TDS Accuracy | ±1% FS |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.5 °C |
| Calibration | Up to 6-point pH (NIST & USA buffer standards), 1-point per conductivity/TDS range, manual or automatic |
| Data Storage | 500 readings |
| Power | 2 × AA alkaline batteries (>100 h life) |
| Dimensions | 200 × 93 × 57 mm |
| Weight | 500 g |
| Interface | USB and RS-232 |
| Auto-off | After 17 min idle |
| Display | Single-line LCD |
| Brand | Palintest |
|---|---|
| Model | PT 162 |
| Origin | United Kingdom |
| Instrument Type | Pen-style Portable Meter |
| Parameter Types | pH, TDS, Conductivity, Salinity, Temperature |
| Calibration Standard | NIST-traceable solutions |
| IP Rating | IP67 |
| Power Supply | 4 × 1.5 V button cells (typical battery life >150 h |
| Operating Temperature | 0–50 °C |
| Automatic Temperature Compensation (ATC) | Yes |
| Measurement Ranges | pH 0.00–14.00 (±0.01) |
| Resolution | pH 0.01 |
| Calibration | Up to 5-point pH auto-calibration |
| TDS Conversion Factor | Adjustable 0.40–1.00 |
| Brand | Palintest |
|---|---|
| Origin | United Kingdom |
| Model | PT151 |
| Instrument Type | Pen-style |
| Parameter Type | Single-parameter |
| Measurement Accuracy | ±0.1 pH / ±1% FS (Conductivity & TDS) |
| Calibration Standard | NIST-traceable buffer and standard solutions |
| Protection Rating | IP67 |
| Operating Temperature | 0–50 °C |
| Temperature Compensation | Automatic (ATC) |
| Power Supply | 4 × 1.5 V LR44/A76/V13GA button cells (>100 h battery life |
| Dimensions | 163 × 40 mm |
| Weight | 90 g |
| Brand | PalmSens |
|---|---|
| Origin | Netherlands |
| Model | EmStat4M |
| Instrument Type | Portable Electrochemical Workstation |
| Channel Count | Single-Channel |
| Current Range | ±30 mA |
| Current Accuracy | ≤ 0.2% |
| Potential Accuracy | ≤ 0.2% |
| Potentiostatic Range | ±3 V |
| EIS Frequency Range | 10 µHz to 200 kHz |
| Brand | PalmSens |
|---|---|
| Origin | Netherlands |
| Model | EmStat4R |
| Instrument Type | Portable Electrochemical Workstation |
| Channel Count | Single-Channel |
| Current Range | ±30 mA |
| Current Accuracy | ≤ 0.2% |
| Potential Accuracy | ≤ 0.2% |
| Potentiostatic Range | ±3 V |
| EIS Frequency Range | 10 µHz to 200 kHz |
| Brand | PalmSens |
|---|---|
| Origin | Netherlands |
| Model | EmStat4S |
| Instrument Type | Portable Electrochemical Workstation |
| Channel Count | Single-Channel |
| Current Range | ±30 mA |
| Current Accuracy | ≤ 0.2% |
| Potential Accuracy | ≤ 0.2% |
| Potentiostatic Range | ±3 V |
| EIS Frequency Range | 10 µHz to 200 kHz |
| Brand | PalmSens |
|---|---|
| Origin | Netherlands |
| Model | EmStat4T |
| Instrument Type | Portable Electrochemical Workstation |
| Channel Count | Single-Channel |
| Current Range | ±30 mA |
| Current Accuracy | ≤ 0.2% |
| Potential Accuracy | ≤ 0.2% |
| Potentiostatic Range | ±3 V |
| EIS Frequency Range | 10 µHz to 200 kHz |
| Brand | PalmSens |
|---|---|
| Origin | Netherlands |
| Model | EmStat4X |
| Instrument Type | Portable Electrochemical Workstation |
| Channel Count | Single-Channel |
| Current Range | ±30 mA |
| Current Accuracy | ≤ 0.2% |
| Potential Accuracy | ≤ 0.2% |
| Potentiostatic Range | ±3 V |
| EIS Frequency Range | 10 µHz to 200 kHz |
| Brand | PalmSens |
|---|---|
| Origin | Netherlands |
| Model | MultiEmStat4 |
| Channel Count | 4 / 8 / 12 (configurable) |
| Current Range | ±30 mA |
| Current Accuracy | ≤ 0.2% |
| Potential Accuracy | ≤ 0.2% |
| Potentiostatic Range | ±3 V |
| EIS Frequency Range | 10 µHz to 200 kHz |
| Brand | PalmSens |
|---|---|
| Origin | Netherlands |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | NEXUS |
| Instrument Type | Electrochemical Workstation |
| Channel Count | Single-Channel |
| Current Range | 100 pA to 1 A (11 decades) |
| Current Accuracy | ±0.1% of reading |
| Potential Accuracy | ±0.1% of full scale |
| Potentiostatic Range | ±10 V |
| EIS Frequency Range | 10 µHz to 1 MHz |
| Communication Interface | USB-C and Ethernet |
| Onboard Storage | 32 GB internal flash memory |
| Optional Dual-Potentiostat Mode | Available |
| Software Platform | .NET-based desktop application with SDK and MethodSCRIPT™ support |
| Brand | PalmSens |
|---|---|
| Origin | Netherlands |
| Model | PS4&MUX8/MUX16 |
| Instrument Type | Portable Electrochemical Workstation |
| Number of Channels | 8 (expandable to 128 via daisy-chained MUX8-R2 modules) |
| Current Range | 100 pA to 10 mA (9 decades) |
| Current Accuracy | ≤ 0.1 % |
| Potential Accuracy | ≤ 0.2 % |
| Potentiostatic Range | ±10.000 V |
| EIS Frequency Range | 10 μHz to 1 MHz |
| Power Supply | Rechargeable Li-ion battery or USB-powered |
| Brand | PalmSens |
|---|---|
| Origin | Netherlands |
| Model | Sensit BT |
| Instrument Type | Portable Electrochemical Workstation |
| Current Range | 100 nA to 3 mA |
| Current Accuracy | < 1% of selected current range |
| Potential Accuracy | ≤ 0.5% |
| Potentiostatic Range | −1.7 V to +2.0 V |
| EIS Frequency Range | 0.016 Hz to 200 kHz |
| Brand | PalmSens |
|---|---|
| Origin | Netherlands |
| Model | Sensit_BT |
| Instrument Type | Portable Electrochemical Workstation |
| Current Range | 100 nA to 3 mA |
| Current Accuracy | < 1% of selected current range |
| Potential Accuracy | ≤ 0.5% |
| Potentiostatic Range | −1.7 V to +2.0 V |
| Electrochemical Impedance Spectroscopy (EIS) Frequency Range | 0.016 Hz to 200 kHz |
| Brand | PalmSens |
|---|---|
| Origin | Netherlands |
| Model | SensitSmart |
| Instrument Type | Portable Electrochemical Workstation |
| Current Range | 100 nA to 3 mA |
| Current Accuracy | < 1% of selected current range |
| Potential Accuracy | ≤ 0.1% |
| Potentiostatic Range | −1.7 V to +2.0 V |
| EIS Frequency Range | 0.016 Hz to 200 kHz |
| Communication & Power | USB-C |
| Dimensions | 43 × 25 × 11 mm |
| Compatible Electrode Pitch | 2.54 mm |
| Electrode Thickness Support | 0.1–0.8 mm |
| Max Electrode Width | 11 mm |
| Supported Techniques | LSV, CV, DPV, SWV, NPV, CA, I–t, PAD, OCP, MA, EIS |
| Brand | PalmSens |
|---|---|
| Origin | Netherlands |
| Model | PalmSens 4 |
| Instrument Type | Portable Electrochemical Workstation |
| Channel Count | Single-Channel |
| Current Range | 100 pA to 10 mA (9 ranges) |
| Current Accuracy | ≤ 0.1 % of Full-Scale Reading (FSR) |
| Potential Accuracy | ≤ 0.1 % of FSR |
| Potentiostatic Range | ±10.000 V |
| EIS Frequency Range | 10 µHz to 1 MHz |
| Brand | PAS |
|---|---|
| Origin | Germany |
| Model | CONCEPT MIS |
| Instrument Type | GC Autosampler |
| Minimum Injection Volume | 1 µL |
| Positioning Accuracy | <0.3 mm |
| Motion System | XYZ Three-Axis |
| Needle Wash | Internal and External Wall Cleaning (Unlimited Cycles) |
| Re-injection Capability | Unlimited |
| Sample Introduction Modes | Liquid Injection (LI), Liquid–Liquid Extraction (LLE), Static/Dynamic Headspace (HS), Needle Trap (NT), Solid-Phase Microextraction (SPME), On-line Derivatization |
| Compliance | Designed for GLP/GMP environments with audit-trail-ready software architecture |
| Brand | EL-Cell |
|---|---|
| Origin | Germany |
| Model | PAT-Chamber |
| Dimensions (W × D) | 380 mm × 640 mm |
| Height (open/closed lid) | 600 mm / 375 mm |
| Weight (empty) | 32 kg |
| Compatibility | PAT-Core test cells, ECC-PAT-Core cells, PAT-16, PAT-Pressure |
| Data Channels | Battery current, battery voltage, half-cell voltage, temperature, single-cell pressure |
| Interface | Compatible with standard potentiostats/galvanostats and battery cyclers |
| Brand | ZOLIX |
|---|---|
| Model | DPbS3200 |
| Detector Type | Photoconductive PbS |
| Operating Temperature | Room Temperature |
| Spectral Range | 0.8–3.2 µm |
| Peak Wavelength | ≥2.1 µm |
| Responsivity | ≥300 V/W |
| Dark Resistance | 0.1–0.3 MΩ |
| Specific Detectivity (D*) | ≥1×10⁸ cm·Hz¹ᐟ²/W |
| Time Constant | ≤400 µs |
| Gain Settings | ×1, ×10, ×100 |
| Input Offset Voltage | <±1 µV |
| Input Drift | ±1 µV |
| Recommended Lock-in Frequency | 400 Hz |
| Output Mode | Positive-polarity voltage output |
| Active Area | 6×6 mm |
| Origin | Beijing |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic (China) |
| Model | PbSe |
| Pricing | Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PC-4000 |
| Pricing | Upon Request |
| Flow Rate | 0.01–20 mL/min |
| Maximum Pressure | 0.0–6000 psi |
| Baseline Noise | ≤1 × 10⁻⁵ AU |
| Baseline Drift | ≤2 × 10⁻⁴ AU/h |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PC4006 |
| Price Range | USD 14,000–28,000 |
| Instrument Type | Conventional High-Performance Liquid Chromatograph |
| Flow Rate Range | 0.001–40 mL/min |
| Maximum Pressure | 10,000 psi |
| Autosampler Capacity | 120 positions |
| Injection Volume Range | 1–100 µL |
| Column Oven Temperature Range | (Ambient +10 °C) to 150 °C |
| UV-Vis Wavelength Range | 190–900 nm |
| Data Acquisition Rate | 100 Hz |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PCA |
| Price Range | USD 700 – 10,000 |
| Instrument Type | Universal Potentiometric Titrator |
| Application Scope | General-Purpose |
| Measurement Range | −1000 to +1000 mV |
| Meter Accuracy | ±0.1% of full scale |
| Meter Resolution | 1 mV |
| Titration Precision | ±1 mV |