| Brand | Synpec |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic (China-made) |
| Model | AA6810 |
| Instrument Type | Hydride Generation Accessory for Atomic Absorption Spectrometry |
| Monochromator Element | Plane Grating |
| Optical System | Single-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Spectral Resolution | 0.2 nm |
| Sensitivity | Cu 5 ppm → Absorbance > 0.3 A |
| Repeatability (RSD) | < 0.3% |
| Detection Limit (Cu) | < 0.004 µg/mL |
| Brand | Synpec |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Flame AAS |
| Monochromator | Plane Grating |
| Optical System | Single-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Spectral Resolution | 0.2 nm |
| Sensitivity (Cu) | >0.3 A at 5 ppm |
| RSD (Precision) | <0.3% |
| Detection Limit (Cu) | <0.004 µg/mL |
| Wavelength Range | 190–900 nm |
| Slit Widths | 0.1, 0.2, 0.4, 0.7, 1.0, 2.0 nm (auto-switching) |
| Wavelength Accuracy | ±0.2 nm |
| Wavelength Repeatability | 0.1 nm |
| Baseline Drift | 0.002 A / 30 min |
| Background Correction | D₂ Lamp & Self-Reversal |
| Characteristic Concentration (Cu) | ≤0.025 µg/mL / 1% |
| Weight | 65 kg |
| Brand | Synpec |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Flame and Graphite Furnace AAS |
| Monochromator | Plane Grating |
| Optical System | Single-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Deuterium Lamp + Self-Reversal Method |
| Spectral Resolution | 0.2 nm |
| Sensitivity | Cu 5 ppm → Absorbance > 0.3 A |
| Repeatability (RSD) | < 0.3% |
| Detection Limit | Cu < 0.004 µg/mL |
| Brand | Synpec |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | GMA3500 |
| Detector | Photomultiplier Tube (PMT) |
| Wavelength Range | 190–900 nm |
| Spectral Bandwidth | 0.1 / 0.2 / 0.4 / 0.7 / 1.0 / 2.0 nm (6-step auto-switching) |
| Wavelength Accuracy | ±0.1 nm |
| Wavelength Repeatability | ±0.1 nm |
| Brand | Synpec |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | GMA3510 |
| Detector | Photomultiplier Tube (PMT) |
| Wavelength Range | 190–900 nm |
| Spectral Bandwidth | 0.1 / 0.2 / 0.4 / 0.7 / 1.0 / 2.0 nm (6-step motorized selection) |
| Wavelength Accuracy | ±0.1 nm |
| Wavelength Repeatability | ±0.1 nm |
| Brand | Synpec |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Origin | Domestic (China) |
| Model | GMA3610 |
| Price Range | USD 42,000 – 56,000 |
| Brand | Synpec |
|---|---|
| Model | GMA3660 |
| Origin | Shanghai, China |
| Manufacturer | Synpec Instrument Co., Ltd. |
| Price Range | USD 42,000 – 56,000 (FOB Shanghai) |
| Compliance | GB/T 42027-2022, HJ 195-2023, HJ 200-2023, HJ/T 198-2005, HJ/T 197-2005, HJ 199-2023 |
| Detection Modes | NH₃-N, S²⁻, NO₃⁻-N, NO₂⁻-N, TN, Kjeldahl-N |
| Light Source | Deuterium Lamp (with optional Hg lamp for mercury analysis) |
| Detector | CCD Diode Array |
| Key Features | Automated Flow Injection Sampling, Integrated UV Digestion-Dilution Module for Total Nitrogen, On-line Oxidation for Ammonia-N, Cold Trap + Auto-Dehydration System, Closed Reaction-Separation Cell, TCS (Temperature-Controlled Separation) System, Electronic Pressure Monitoring & Alarm |
| Brand | Synpec |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | GMA3710 |
| Price Range | USD 42,000 – 56,000 |
| Brand | Synpec |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | GMA3760 |
| Price Range | USD 42,000 – 56,000 |
| Brand | Synpec |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Model | GMA3860 |
| Price Range | USD 42,000 – 56,000 |
| Compliance | GB/T 42027-2022, HJ 195-2023, HJ 200-2023, HJ/T 198-2005, HJ/T 197-2005, HJ 199-2023 |
| Light Source | Deuterium Lamp (with optional element lamps for Hg analysis) |
| Detector | CCD Diode Array |
| Key Features | Integrated UV digestion-dilution module for total nitrogen, on-line oxidation for ammonia-N, cold trap + auto-dehydration system, auto-rinsing during NO₃⁻/TN analysis, programmable dilution, optional autosampler (7- or 60-position) |
| Brand | Synpec |
|---|---|
| Model | M3000 Micro GC |
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Detection Principle | Micro-Electro-Mechanical Systems (MEMS)-Based Thermal Conductivity Detection (μTCD) |
| Detector Pool Volume | 200 nL |
| Detection Limit | 0.5 ppm (for H₂, CO, CH₄, etc., in N₂ carrier) |
| Analysis Time | < 30 s per channel (multi-channel parallel operation) |
| Column Type | Capillary micro-column (ID ≤ 0.15 mm) |
| Power Supply | Internal rechargeable Li-ion battery (8 h continuous operation) |
| Carrier Gas | Integrated miniature high-pressure gas cylinder (N₂ or He) |
| Communication Interfaces | RS-485, MODBUS RTU, digital/analog I/O |
| Software | Onboard embedded OS with method editor, real-time data processing, and automated report generation |
| Compliance | Designed to support GLP/GMP-aligned workflows |
| Brand | Synpec |
|---|---|
| Model | P200OEM |
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Price Range | USD 14,000 – 42,000 |
| Brand | Synpec |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Region of Origin | Domestic (China) |
| Model | P200GC |
| Price Range | USD 14,000 – 43,000 |
| Dimensions | 410 mm (L) × 280 mm (W) × 235 mm (H) |
| Weight | ≤10 kg |
| Analysis Cycle | NMHC: ≥1 min |
| BTEX | ≥5 min |
| Measurement Range | 0–50,000 ppm |
| LOD | 0.05 ppm |
| Repeatability | RSD ≤1% |
| Accuracy | ±1% of full scale |
| Power Supply | Integrated rechargeable battery, >6 h runtime |
| Operating Temperature | 10–45 °C |
| Detection Principle | Flame Ionization Detection (FID) with capillary column separation |
| Sample Path | Fully heated from inlet to detector (up to 220 °C) |
| Connectivity | Industrial-grade Wi-Fi, USB, Ethernet, optional thermal printer interface |
| Compliance | Designed for field deployment in accordance with EPA Method 25A, ASTM D6348, and ISO 11843-2 for trace hydrocarbon quantification |
| Brand | Synpec |
|---|---|
| Model | SP7210 |
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Measurement Principle | Potassium Permanganate Titrimetric Oxidation (COD<sub>Mn</sub>) |
| Measurement Range | 0–6 mg/L as O<sub>2</sub> |
| Repeatability | RSD ≤ 2.5% |
| Sample Capacity | 54 positions |
| Digestion Time | 30 min at boiling temperature (100 °C) |
| Digestion Mode | Automated water bath with constant temperature and liquid level control |
| Titration Delivery Precision | Adjustable single-dose volume from 0.01 to 0.07 mL |
| Titration Endpoint Detection | Colorimetric endpoint recognition |
| Sample Throughput | One sample per 5 minutes |
| Sample Introduction | Three-axis robotic arm (X/Y/Z) with basket-style tray loading |
| Reagent Delivery | High-accuracy peristaltic pump for KMnO<sub>4</sub>, H<sub>2</sub>SO<sub>4</sub>, and Na<sub>2</sub>OX solutions |
| Compliance | GB 11892–1989 |
| Brand | SYSTEA |
|---|---|
| Origin | Italy |
| Model | EASYCHEM PLUS |
| Product Type | Discrete Analyzer |
| Wavelength Range | 340–880 nm |
| Sample Capacity | 60 positions (18-sample carousel + auxiliary racks) |
| Reagent Positions | 18 |
| Flow Cell Path Length | 10 mm |
| Light Source | 6 V / 10 W Halogen Lamp with UV-Visible Spectral Output |
| Detection Principle | Photometric Colorimetry (Static Reaction in Flow-Through Cuvette) |
| Compliance | Designed for ASTM D129, ISO 6878, ISO 15681, USP <621>, EPA Methods 353.2, 365.2, 4500-NH₃ F, 4500-NO₂⁻ B, 4500-P E, and GLP/GMP-aligned workflows |
| Brand | SYSTEA |
|---|---|
| Origin | Italy |
| Model | EasyChem Plus |
| Optical System | 6 V/10 W halogen lamp with UV extension |
| Filter Wheel | 10-position, 9 interference filters (340, 405, 480, 505, 546, 578, 630, 670, 880 nm |
| Photometric Range | 0–3 Abs |
| Accuracy | ±0.5% or ±1 mAbs (0.1–2.5 Abs) |
| Linearity | ±0.5% (0.1–1.5 Abs) |
| Flow Cell Pathlength | 15 mm or 50 mm selectable |
| Sample Capacity | 60 positions |
| Reagent Carousel | 30-position, refrigerated |
| Analysis Throughput | 60–90 determinations/hour |
| Detection Modes | Endpoint, Differential, Kinetic |
| Calibration Standards | 1–16 points |
| Dilution Precision | 500 µL syringe, 0.096 µL resolution |
| Software Compliance | Audit-trail enabled, QC database with multi-level control (e.g., Westgard rules), automatic pre- and post-dilution, on-board standard series generation |
| Brand | Systea |
|---|---|
| Origin | Italy |
| Model | Easychem Pro |
| Product Type | Discrete Analyzer |
| Wavelength Range | 340–880 nm |
| Sample Capacity | 60 positions (standard carousel) / 30 positions (dual-carrousel configuration) |
| Reagent Positions | 30 |
| Cuvette Path Length | 10 mm |
| Light Source | 6 V / 10 W Halogen Lamp with UV-Visible Output |
| Brand | Ekspla |
|---|---|
| Origin | Lithuania |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | T-FIBER |
| Pricing | Upon Request |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | T11 |
| Price Range | USD 700 – 7,000 |
| Instrument Type | General-purpose Potentiometric Titrator |
| Application Scope | Universal |
| pH Measurement Range | 0–14 |
| mV Measurement Range | ±2000 mV |
| pH Resolution | 0.01 |
| mV Resolution | 0.1 mV |
| pH Accuracy | ±0.01 |
| mV Accuracy | ±0.2 mV |
| Titration Accuracy | ±0.15% (10 mL), ±0.2% (20 mL) |
| Minimum Dispensing Volume | 10 µL |
| Stepper Motor Resolution | 1/60,000 steps |
| Temperature Interface | Pt1000 (Resolution: 0.1 °C, Max Error: ±0.2 °C) |
| Electrode Interfaces | 2 x indicator electrode, 2 x reference electrode, 2 x polarizable electrode |
| Color Sensor | 16-bit RGB tri-color sensor |
| Dimensions | 200 × 200 × 260 mm |
| Weight | 4.3 kg |
| Brand | Tachyonics |
|---|---|
| Origin | USA |
| Model(s) | COMET I, COMET II, COMET III, Nebula I |
| Spectral Range | 650–1000 nm & 1000–1650 nm |
| Detector Type | Photonic time-stretch + high-speed digitizer |
| Spectral Resolution | >10 pm (2 configurable options for COMET I |
| Temporal Resolution | >15 fs |
| Sensitivity | down to 50 µW (max input power: 10 mW) |
| Single-Shot Temporal Window | <300 ps |
| Time-Bandwidth Product (TBWP) | <20,000 (2 or 7 selectable configurations) |
| Input Fiber | SMF-28, FC/APC |
| Intensity Accuracy | ±3% |
| Power Supply | 90–270 VAC, 50/60 Hz |
| Dimensions & Weight | COMET I: 14.33" × 5.79" × 13.03", 10 lbs |
| COMET II | same footprint, 15 lbs |
| COMET III | 14.33" × 11.04" × 15.39", 20 lbs |
| Integrated Hardware | COMET II — embedded PC + 7" HD touchscreen + 5G Wi-Fi hotspot |
| Brand | Metrohm |
|---|---|
| Origin | USA |
| Manufacturer | Metrohm |
| Type | Portable/Handheld Raman Spectrometer |
| Spectral Range | 176–2500 cm⁻¹ |
| Spectral Resolution | 10 cm⁻¹ |
| Minimum Wavenumber | 176 cm⁻¹ |
| Spectral Reproducibility | <1 cm⁻¹ |
| Laser Wavelength | 1064 nm |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | TB-2 |
| Price Range | USD 140–700 (FOB) |
| Instrument Type | TLC Scanner Accessory |
| Wavelength Range | 190–700 nm (multi-band selectable) |
| Calibration Wavelengths | UV 254 nm, UV 365 nm, and White Light |
| Plate Size Capacity | 50 × 50 mm to 200 × 200 mm |
| Adjustability | Horizontal Leveling ±0.1°, Width Adjustment Range: 50–220 mm |
| Construction | Anodized Aluminum Frame with Tempered Glass Doors & Stainless Steel Shelves |
| Brand | Hefei Kejing |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | TbScO₃ Single Crystal Substrate |
| Price | Upon Request |
| Crystal Structure | Orthorhombic (Space Group: Pbnm) |
| Lattice Parameters | a ≈ 5.52 Å, b ≈ 5.70 Å, c ≈ 7.88 Å |
| Melting Point | ~2120 °C |
| Density | ~6.8 g/cm³ |
| Growth Method | Czochralski (Cz) |
| Orientation | <110> ± 0.5° |
| Dimensions | 10 × 10 × 0.5 mm³ or 5 × 5 × 0.5 mm³ |
| Surface Finish | Single-side polished |
| Surface Roughness (Ra) | < 0.5 nm |
| Packaging | Vacuum-sealed in Class 100 cleanroom bags, stored and shipped from Class 1000 cleanroom environment |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | TCL-1B |
| Instrument Type | General-Purpose Potentiometric Titrator |
| Application Scope | Cement Chloride Ion Analysis Dedicated |
| Measurement Range | mV: −2000 to +2000 mV |
| pH | 0.000–14.000 |
| Temperature | −55.0 to +125.0 °C |
| Meter Accuracy | ±0.5% of full scale |
| Meter Resolution | 0.1 mV |
| Titration Precision | ≤0.8 mV/h |
| Origin | USA |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | TCM 500 Turf Colorimeter |
| Pricing | Upon Request |
| Measurement System | Internal LED-based reflectance at red (650 nm) and near-infrared (850 nm) wavelengths |
| Measurement Area | ~7.75 cm diameter (3.0 in) |
| Output Units | RED (%) and NIR (%), Green Index (0–9.9), NDVI = (NIR − RED) / (NIR + RED) |
| Repeatability | ±5% of reading |
| Data Storage Capacity | 3,250 measurements (GPS/DGPS disabled) |
| Power Supply | 9 V alkaline battery (~3,000 measurements per charge) |
| Brand | Tongda |
|---|---|
| Origin | Liaoning, China |
| Model | TD-5000 |
| Instrument Type | Single-Crystal X-ray Diffractometer |
| Configuration | Floor-Standing |
| X-ray Source Power | 3 kW |
| 2θ Angular Repeatability | 0.0001° |
| Minimum Step Angle | 0.0001° |
| Temperature Control Range | 100 K – 300 K |
| Temperature Stability | ±0.3 K |
| Detector | PILATUS Hybrid Pixel Detector |
| Goniometer Architecture | Four-Circle Concentric Design |
| Data Acquisition Interface | Touchscreen-Controlled PLC System |
| Brand | Tongda |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | TD-Mini |
| Price Range | USD 70,000 – 140,000 |
| X-ray Tube Power | 60 W |
| 2θ Angular Range | 45°–170° (continuously adjustable) |
| ψ Tilt Angle Range | 0° to ±45° |
| Anode Target Material | Chromium (Cr) |
| X-ray Source | Fine-focus Ceramic Tube with Integrated Closed-loop Self-circulating Cooling System |
| Detector | High-speed Silicon Strip Photon-counting Area Detector (640-channel linear array), Total Count Rate > 1×10⁹ cps |
| Brand | Tongda |
|---|---|
| Model | TD-RSD |
| X-Ray Tube Anode Material | Cr |
| Maximum Power | 3 kW |
| Detector Type | Photon-Counting Area Detector (Dual Symmetric Configuration) |
| Angular Positioning Accuracy | ≤ 0.01° (2θ) |
| Stress Measurement Repeatability (Stress-Free Iron Powder) | σ < ±7 MPa (n = 5) |
| Sample Stage | Motorized XYZ + Φ Tilt Stage |
| Cooling System | Integrated Closed-Loop Ceramic X-Ray Tube Cooling |
| Compliance | ASTM E915, ISO 21432, EN 15305 |
| Dimensions (W×D×H) | 1300 × 1200 × ~1800 mm |
| Target Options | Cr, Cu, Mn, Co, V, Ti, Fe, Mo |
| Brand | Colintech |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Model | TDC20 |
| Temperature Control Range | Ambient to 400 °C |
| Gas Flow Rate | 0–1000 mL/min |
| Tube Capacity | 20 tubes |
| Power Supply | 220 V AC, 3 A |
| Compliance | Designed for ASTM D6196, ISO 16017-1, and USP <621> thermal desorption system preparation protocols |
| Brand | Tongda |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | TDTC-150 |
| Price Range | USD 70,000 – 140,000 |
| X-ray Tube Power | 200 W |
| 2θ Angular Range | 45°–170° (continuously adjustable) |
| ψ Tilt Angle Range | 0° to ±45° |
| Anode Target Material | Chromium (Cr) |
| Measurement Methods | Sin²ψ, Side-Inclination, Tilt-and-Rotate |
| Stress Output | Principal Stresses (σ₁, σ₂, σ₃) and Shear Stress (τ) |
| Phase Analysis Mode | Four-Peak Method for Retained Austenite Quantification |
| Detector | Multi-channel Silicon Strip Linear Array Detector |
| Control System | PLC-based Modular Architecture |
| Operating System | Integrated Windows OS with Real-time Data Visualization |
| Sample Compatibility | Ferrous & Non-ferrous Metals, Titanium Alloys, Nickel-Based Superalloys, Glass, Composites |