| Brand | Sunny Hengping Instrument |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (PRC) |
| Model | GC1290/MS8100 |
| Instrument Type | Single Quadrupole Mass Spectrometer |
| GC Configuration | Conventional GC-MS |
| Mass Range | 1.5–1100 u |
| Resolution | >1200 (FWHM) |
| Sensitivity | 600:1 (S/N for 1 pg octafluoronaphthalene) |
| Scan Speed | Up to 24,000 u/sec |
| Oven Ramp Rate | 0–80 °C/min |
| Pressure Control Accuracy | 0–100 psi |
| Brand | SUNNY HENGPING INSTRUMENT |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Single Quadrupole Mass Spectrometer |
| GC Configuration | Conventional Capillary GC-MS |
| Mass Range | 1–1000 amu |
| Mass Resolution (FWHM) | ≥1200 (at m/z 502) |
| Sensitivity | ≥200:1 (Signal-to-Noise Ratio, S/N, for 1 pg OFN in Full Scan Mode) |
| Scan Speed | ≥10,000 u/s |
| Oven Ramp Rate | ≥80 °C/min |
| Pressure Control Accuracy | ±0.01 psi (EPC-controlled) |
| Brand | Sunny Hengping Instrument |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | IC1800 |
| Instrument Type | Laboratory Benchtop System |
| Pump Pressure Range | 0–25 MPa |
| Flow Rate Range | 0.000–9.999 mL/min |
| Eluent Flow Rate Range | 0.000–9.999 mL/min |
| Maximum Operating Pressure | 25 MPa |
| Column Oven Temperature Range | Ambient to 60 °C |
| Temperature Reproducibility | ±0.1 °C within ambient +2 °C to 100 °C |
| Eluent Concentration Range | 0–100 mmol/L (expressed as OH⁻) |
| Brand | Sunny Hengping Instrument |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | IC1820 |
| Instrument Type | Laboratory Benchtop |
| Maximum Pump Pressure | 35 MPa |
| Flow Rate Range | 0–9.999 mL/min |
| Eluent Flow Rate | 1.5 mL/min |
| Max Operating Pressure | 15 MPa |
| Column Oven Temperature Range | 25–60 °C |
| Temperature Stability | ±0.5 °C |
| Eluent Concentration Range | 0–100 mM (OH⁻ or CO₃²⁻/HCO₃⁻) |
| Brand | Sunny Hengping Instrument |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Origin | Domestic (China) |
| Model | LC1620A |
| Instrument Category | Conventional HPLC System |
| Flow Rate Range | 0.001–9.999 mL/min |
| Maximum Pressure | 45 MPa |
| Autosampler Capacity | 0–120 positions |
| Injection Volume Range | 0–120 µL |
| Column Oven Temperature Range | Ambient +5°C to 100°C |
| UV-Vis Wavelength Range | 190–700 nm |
| Data Acquisition Frequency | 1 Hz |
| Brand | Sunny Hengping Instrument |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | LC1620APlus |
| Price Range | USD 7,000–14,000 (FOB Shanghai) |
| Instrument Type | Conventional HPLC System |
| Application Scope | General-Purpose Analytical HPLC |
| Flow Rate Range | 0.000–10.000 mL/min |
| Maximum Operating Pressure | 42 MPa |
| Flow Accuracy | ≤ ±0.3% RSD |
| Wavelength Range (UV-Vis Detector) | 190–680 nm |
| Brand | SUNNY HENGPING INSTRUMENT |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | RI-500 Series |
| Detector Type | Refractive Index Detector (RID) |
| Compatible Systems | HPLC |
| Flow Cell Volume | 2.5–8 µL |
| Linear Range | 600–6000 µRIU |
| Noise | 2.5–5 nRIU (H₂O, 1.5 s response) |
| Drift | 0.2–2 µRIU/h |
| Response Time | 0.1–6 s (adjustable) |
| Temperature Control | 30–55 °C (dual-zone) |
| Max Backpressure | 50 kPa |
| Interface | LAN |
| Power | AC 100–240 V ±10%, 50/60 Hz, 150 VA |
| Dimensions | 260 W × 420 D × 165 H mm |
| Weight | 12.5 kg |
| Brand | Sunny Hengping Instrument |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic (China-Made) |
| Model | SHP8400PMS |
| Operating Principle | Electron Ionization (EI) coupled with Quadrupole Mass Analysis |
| Response Time | 16 ms per amu |
| Mass Range | 1–100 amu (standard configuration) |
| Mass Stability | < ±0.1 amu over 72 h |
| Sampling Channels | 16 independent channels with temperature-controlled capillary lines |
| Detection System | Faraday Cup Detector |
| Ion Source | Dual-filament EI source with enhanced water/oxygen tolerance |
| Flow Control | Integrated temperature-compensated electronic mass flow controller (MFC) |
| Data Output Format | OPC UA, Modbus TCP, ASCII CSV |
| Software Compliance | FDA 21 CFR Part 11-ready audit trail, GLP/GMP-compatible logging |
| Brand | Sunny Hengping Instrument |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Category | Domestic (China-Made) |
| Model | SHP8400PMS-L |
| Price Range | USD 42,000 – 70,000 |
| Brand | Sunny Hengping Instrument |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | SHP8400PMS-LD |
| Pricing | Available Upon Request |
| Brand | Sunny Hengping Instrument |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | SHP8400PMS-Li |
| Pricing | Upon Request |
| Brand | SUNNY HENGPING INSTRUMENT |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | UV2000 |
| Optical Design | Single-Beam |
| Detector Type | Silicon Photodiode |
| Wavelength Range | 200–1000 nm (0.1 nm step), extendable to 190–1100 nm |
| Wavelength Accuracy | Automatic Calibration |
| Spectral Bandwidth | 2 nm |
| Display | 4.3-inch color TFT touchscreen (480 × 272) |
| Data Interface | USB |
| Power Supply | 220 V ±10%, 50 Hz / 110 V ±10%, 60 Hz, 90 W |
| Dimensions (W×D×H) | 470 × 380 × 225 mm |
| Net Weight | 10.5 kg |
| Brand | Sunny Hengping Instrument |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | UV2200 |
| Optical Design | Dual-beam |
| Detector | Photodiode Array |
| Wavelength Range | 190–1100 nm (0.1 nm step resolution) |
| Spectral Bandwidth | 4 nm |
| Wavelength Accuracy | ±0.3 nm |
| Wavelength Repeatability | ±0.1 nm |
| Photometric Accuracy | ±0.002 Abs (0–0.5 Abs), ±0.004 Abs (0.5–1.0 Abs) |
| Photometric Repeatability | ±0.001 Abs |
| Stray Light | ≤0.05% T at 220 nm and 360 nm |
| Baseline Flatness | ±0.001 Abs (200–1000 nm) |
| Interface | USB 2.0 |
| Display | 4.3-inch color TFT touchscreen (480 × 272 pixels) |
| Power Supply | 220 V ±10%, 50 Hz / 110 V ±10%, 60 Hz, 90 W |
| Dimensions (W×D×H) | 470 × 380 × 225 mm |
| Net Weight | 10.5 kg |
| Brand | Sunny Hengping Instrument |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | UV2400 |
| Price Range | USD 1,400 – 2,800 (FOB Shanghai) |
| Optical Design | Proportional-monitoring double-beam |
| Detector Type | Silicon photodiode |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.5 nm |
| Spectral Bandwidth | 1.8 nm |
| Wavelength Scanning Step | 0.1 nm |
| Display | 128 × 64 dot-matrix LCD |
| Sample Holder | Automated 8-cell rotating cuvette holder (10 mm pathlength) |
| Data Interface | USB 2.0 |
| Power Supply | 220 V ±10%, 50 Hz or 110 V ±10%, 60 Hz |
| Dimensions (L×W×H) | 545 × 450 × 235 mm |
| Net Weight | 17.0 kg |
| Gross Weight | 26.0 kg |
| Brand | Sunny Hengping Instrument |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China) |
| Model | UV2600 |
| Price Range | USD 2,800–4,200 (FOB Shanghai) |
| Optical Design | Proportional-monitoring double-beam |
| Detector Type | Silicon photodiode |
| Wavelength Range | 190–1100 nm |
| Wavelength Automation | Motorized wavelength drive with automatic calibration |
| Spectral Bandwidth | 1.8 nm |
| Wavelength Accuracy | ±0.3 nm |
| Wavelength Repeatability | ≤0.2 nm |
| Stray Light | ≤0.05% T (at 220 nm and 360 nm) |
| Photometric Accuracy | ±0.3% T |
| Photometric Repeatability | ≤0.1% T |
| Baseline Flatness | ±0.002 A |
| Baseline Drift | ≤0.001 A/h (at 500 nm) |
| Display | 6-inch 320×240 LCD |
| Brand | Sunny Hengping Instrument |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (PRC) |
| Model | UV2800 / UV2800S |
| Optical System | Dual-beam |
| Detector Type | Silicon Photocell |
| Wavelength Range | 190–1100 nm |
| Spectral Bandwidth | 1.8 nm (UV2800) |
| Wavelength Accuracy | ±0.3 nm |
| Wavelength Repeatability | ±0.1 nm |
| Photometric Accuracy | ±0.002 A (0–0.5 A), ±0.004 A (0.5–1 A), ±0.3 %T (0–100 %T) |
| Photometric Repeatability | ±0.001 A (0–0.5 A), ±0.002 A (0.5–1 A), ±0.15 %T (0–100 %T) |
| Stray Light | ≤0.03 %T at 220 nm & 360 nm |
| Baseline Flatness | ±0.001 A (200–1000 nm) |
| Scan Speed | 10–3000 nm/min (adjustable) |
| Display | 320 × 240 pixel LCD (6-inch) |
| Interface | USB 2.0 |
| Power Supply | 220 V ±10 %, 50 Hz or 110 V ±10 %, 60 Hz |
| Dimensions (W × D × H) | 545 × 450 × 235 mm |
| Net Weight | 17.0 kg |
| Gross Weight | 26.0 kg |
| Brand | Sunny Hengping Instrument |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China-Made) |
| Model | UV2900 |
| Price Range | USD 7,000–10,000 (FOB Shanghai) |
| Optical Design | Dual-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Wavelength Range | 190–900 nm (extendable to 185 nm) |
| Wavelength Drive | Motorized Auto-Scanning |
| Spectral Bandwidth | 0.1–5.0 nm continuously variable |
| Default Discrete Bandwidth Settings | 0.1, 0.2, 0.5, 1.0, 2.0, 3.0, 4.0, 5.0 nm |
| Data Output | Digital via USB 2.0 |
| Power Supply | 220 V ±10%, 50 Hz, 200 W |
| Net Weight | 30.0 kg |
| Dimensions (L×W×H) | 620 × 510 × 245 mm |
| Packaging Dimensions (L×W×H) | 745 × 635 × 400 mm |
| Brand | SUNNY HENGPING INSTRUMENT |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Model | V2200 Visible Spectrophotometer |
| Optical Design | Single-beam |
| Detector Type | Silicon photodiode |
| Wavelength Range | 325–1100 nm (0.1 nm step increment) |
| Spectral Bandwidth | 2 nm |
| Wavelength Accuracy | Auto-wavelength positioning |
| Display | 4.3-inch color TFT touchscreen (480 × 272 pixels) |
| Data Interface | USB |
| Light Source | Imported 20 W / 12 V halogen lamp |
| Power Supply | 220 V ±10%, 50 Hz / 110 V ±10%, 60 Hz |
| Net Weight | 10.0 kg |
| Dimensions (W × D × H) | 470 × 380 × 225 mm |
| Brand | EXPEC |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SUPEC 5220 |
| Instrument Type | Triple Quadrupole (QqQ) |
| Application Scope | General-Purpose LC-MS/MS Platform |
| Configuration | Integrated Online SPE-LC-MS/MS |
| Brand | EXPEC |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic Instrument |
| Model | SUPEC 7000 |
| Instrument Type | Quadrupole ICP-MS |
| Application Environment | Laboratory-Based Analysis |
| Key Features | High-Temperature Gas Flow Control, Multi-Stage Gradient Vacuum System, High-Efficiency Ion Interface, Distributed Collision/Reaction Cell, Temperature- and Humidity-Stable Quadrupole Mass Analyzer |
| Compliance Context | Designed for GLP/GMP-aligned laboratories |
| Software Platform | EXPEC ICP-MS Control Suite v3.2 (with method validation templates, QC flagging, and raw data integrity logging) |
| Brand | EXPEC |
|---|---|
| Origin | Zhejiang, China |
| Model | SUPEC 7010 |
| Instrument Type | Quadrupole ICP-MS |
| Application Domain | Laboratory & Environmental Monitoring |
| Compliance | HJ 700–2014 |
| Automation Level | Fully Automated Sample Intake, Filtration, Pre-treatment, Analysis, QC, and Data Transmission |
| Detection Scope | Multi-element (As, Cd, Cr, Cu, Hg, Ni, Pb, Zn, etc.) in Surface Water, Groundwater, Drinking Water, and Seawater |
| Measurement Time per Sample | <5 min |
| Interference Resistance | High (immune to color, turbidity, matrix-induced polyatomic interferences via collision/reaction cell technology) |
| Environmental Profile | Low reagent consumption, no electrode wear, near-zero liquid waste generation |
| Regulatory Alignment | Designed for GLP-compliant operation |
| Brand | FPI (Focus Photonics Inc.) |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Quadrupole ICP-MS |
| Application Environment | Laboratory |
| Automation Level | Full End-to-End Sample-to-Result Automation |
| Sample Forms Supported | Solid and Liquid Matrices |
| Acid Compatibility | HNO₃, HCl, HF, HClO₄ |
| Volumetric Accuracy | <0.025 mL (5–50 mL range) |
| Sample Introduction | Integrated Auto-Sampling with In-Line Filtration |
| Safety Features | Auto-Ignition, Auto-Optimization, Auto-Quenching, Acid-Fume Extraction, Corrosion-Resistant Fluidic Pathways |
| Calibration & QC | Auto-Standard Curve Generation, Multi-Point QC Triggering (LOD, Blank, CRM), Adaptive Response Logic (Re-run / Skip / Abort) |
| Data Interface | Real-Time CPS/Concentration/RSD Dashboard, Interactive Calibration Plotting, Outlier Flagging |
| Brand | EXPEC |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | SUPEC 7030 |
| Instrument Type | Quadrupole ICP-MS |
| Application Environment | Laboratory & Continuous Ambient Air Monitoring |
| Detection Mode | Online Automated ICP-MS Analysis with Integrated Sample Preparation |
| Brand | Supernova / EXPEC |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | EXPEC 6500 |
| Instrument Type | Full-Spectrum Simultaneous ICP-OES |
| Detection Limit | Not Specified |
| Precision (RSD) | <1% @ 8 h |
| Wavelength Range | 160–900 nm |
| Optical Resolution | Not Specified |
| RF Power Range | 500–1600 W (Digital Self-Excited Solid-State Generator) |
| Observation Mode | Dual-View Vertical Torch (Axial & Radial) |
| Detector | Custom Large-Area E-CCD |
| Brand | SurfaceOptics |
|---|---|
| Origin | USA |
| Model | 410Solar |
| Measurement Principle | Integrating Sphere-Based Spectral Reflectance Metrology |
| Imaging Type | Interferometric (for spectral calibration traceability) |
| Deployment Mode | Ground-Based Field & Laboratory Use |
| Compliance | ASTM E903, ASTM C1549 |
| Spectral Range | 335–2500 nm across 7 discrete bands |
| Incident Angle | 20° from normal |
| Beam Spot Diameter | 0.250" |
| Beam Half-Angle | 3° |
| Measurement Time | 10 s per acquisition |
| Warm-up Time | 90 s (VIS-NIR tungsten source) |
| Detector | Thermopile + Si/InGaAs array architecture |
| Data Output | Total reflectance, diffuse reflectance, and 20° specular reflectance |
| Calibration | NIST-traceable gold mirror standard included |
| Operating Environment | 0–40 °C (non-condensing) |
| Storage | −25–70 °C |
| Power | Rechargeable NiMH battery pack (dual cells) |
| Weight | 2.1 kg (inclusive of batteries) |
| Interface | Touchscreen LCD with embedded PDA OS |
| Data Storage | Internal SD card |
| Probe Design | Modular, field-replaceable head |
| Brand | SurfaceOptics |
|---|---|
| Origin | USA |
| Model | ET-10 |
| Measurement Principle | Directional-Hemispherical Reflectance (DHR)-based Emissivity Calculation |
| Spectral Bands | 3–5 µm and 8–12 µm |
| Incident Angle | 20° from normal |
| Sample Compatibility | Opaque materials, convex surfaces up to 6" radius, concave surfaces up to 12" radius |
| Measurement Time | ≤10 s per acquisition (7 s typical) |
| Warm-up Time | 90 s |
| IR Source | Chromel–Alumel–Cobalt alloy |
| Detector Configuration | Dual-band, simultaneous measurement |
| Display | Touch-enabled LCD PDA interface |
| Power | Rechargeable NiMH battery pack (2 units) |
| Operating Temperature | 0–40 °C (non-condensing) |
| Storage Temperature | −25–70 °C |
| Weight | 2.1 kg (including batteries) |
| Calibration | NIST-traceable gold mirror reference standard included |
| Compliance | ASTM E1933, ISO 18434-1, USP <1210>, GLP-compliant data logging |
| Brand | SurfaceOptics |
|---|---|
| Origin | USA |
| Model | ET10 |
| Instrument Type | Handheld Portable Emissometer |
| Spectral Bands | 3–5 µm and 8–12 µm |
| Measurement Principle | Directional-Hemispherical Reflectance (DHR) → Emissivity = 1 − R(λ) for Opaque Materials |
| Accuracy | ±1% |
| Repeatability | ±0.0002 |
| Incident Angle | 20° off-normal (quasi-normal illumination) |
| Sample Compatibility | Flat or curved surfaces (min. radius 6″ convex / 12″ concave) |
| Measurement Time | 7 s per dual-band acquisition |
| Warm-up Time | 90 s |
| Battery Life | 2 h (rechargeable NiMH) |
| Weight | 4.7 lbs (2.13 kg) with battery |
| Dimensions | H 11.54″ × L 9.04″ × W 3.72″ (293 × 229 × 94 mm) |
| IR Source | CoCrAl alloy filament, operated at ~1000 °C |
| Data Storage | 265 MB CompactFlash card |
| Output Formats | CSV and plain-text (compatible with Excel, MATLAB, Python pandas) |
| Operating Environment | 0–40 °C, non-condensing |
| Storage Range | −25 to 70 °C |
| Interface | Touch-enabled LCD PDA with graphical UI and soft keys |
| Modularity | Interchangeable measurement heads |
| Brand | SurfaceOptics (SOC) |
|---|---|
| Origin | USA |
| Model | ET100 |
| Spectral Range | 1.0–21 µm |
| Measurement Geometry | Bidirectional (20° & 60° incidence) |
| Spectral Bands | Six discrete bands (1.5–2.0, 2–3, 3–4, 4–5, 5–10, 10–21 µm) |
| Accuracy | ±1.5% |
| Measurement Time | ≤10 s per full-band acquisition |
| Warm-up Time | 90 s |
| Battery Life | 2 h (rechargeable NiMH) |
| Weight | 4.7 lbs (2.13 kg) |
| Operating Temperature | 0–40 °C (non-condensing) |
| Storage Temperature | −25–70 °C |
| Detector Type | Thermopile-based broadband IR sensor array |
| Calibration Traceability | NIST-traceable standards |
| Interface | Touchscreen PDA with graphical LCD |
| Data Storage | 265 MB CompactFlash |
| Output Formats | CSV, TXT, Excel-compatible |
| Brand | SurfaceOptics |
|---|---|
| Origin | USA |
| Model | LightShift |
| Spectral Range | 400–1000 nm |
| Spectral Resolution | Avg. 25 nm |
| Spatial Resolution | 512 × 512 pixels |
| Spectral Channels | 16 simultaneous channels (or 12 spectral + 4 polarimetric) |
| Data Acquisition Rate | 28 hyperspectral cubes per second |
| Detector Type | CCD |
| Dynamic Range | 12-bit |
| Pixel Pitch | 7.4 µm (spectral) × 29.6 µm (spatial) |
| Exposure Time | 1 ms |
| F-number | f/2.7 |
| Lens Focal Length | 66 mm |
| Horizontal FOV | 6.5° |
| Weight | 3.2 kg |
| Dimensions | 17.1 × 9.5 × 28.2 cm |
| Power | 12 VDC, <12 W |
| Interface | USB 3.0 |
| Minimum System Requirements | Intel Core i7 or higher, 8 GB RAM, Windows 10, NVIDIA GeForce GTX 980 / 980 Ti / 1080 or higher GPU |
| Brand | SurfaceOptics (SOC) |
|---|---|
| Origin | USA |
| Model | 410DHR |
| Spectral Range | 0.9–1.1, 1.9–2.4, 3.0–4.0, 3.0–5.0, 4.0–5.0, 8.0–12.0 µm |
| Incident Angles | 20° and 60° from normal |
| Measurement Principle | Modified integrating sphere method (collaboratively validated with NRL and NIST) |
| Detector Count | 6 discrete IR detectors |
| Measurement Time | ≤7 s per acquisition (after 90 s IR source warm-up) |
| Sample Geometry Support | Flat, convex (≥6" radius), concave (≥12" radius) |
| Operating Environment | 0–40 °C, non-condensing |
| Storage Temperature | −25 to 70 °C |
| Power | Rechargeable NiMH battery pack (dual cells) |
| Weight | 2.1 kg (with batteries) |
| Calibration | NIST-traceable gold mirror reference standard included |
| Compliance | Designed for field-deployable radiometric measurement in accordance with ASTM E903, ISO 9050, and MIL-STD-461G optical testing protocols |