| Brand | SurfaceOptics |
|---|---|
| Origin | USA |
| Model | SOC 730VS |
| Operating Principle | Push-broom |
| Imaging Modality | 3D hyperspectral datacube acquisition |
| Deployment | Ground-based and airborne compatible |
| Spectral Range | 400–1000 nm |
| Spectral Resolution | 2 nm |
| Spatial Resolution (IFOV) | 0.17 mrad |
| Field of View (TFOV) | 10° |
| Detector Array | 1024 × 1024 pixels |
| Frame Rate | 15 fps |
| Bit Depth | 12-bit |
| Optical f-number | f/2.4 |
| Smile Distortion | <1.5 µm |
| Interface | Camera Link |
| Power Supply | AC / 12 V DC |
| Tripod Mount | 3/8″–16 |
| Brand | SurfaceOptics |
|---|---|
| Origin | USA |
| Model | SOC 750MW |
| Spectral Range | 2–5 µm |
| Detector Type | InSb Focal Plane Array (FPA) |
| Spatial Resolution | 256 × 240 or 512 × 512 pixels |
| Spectral Channels | 42 or 64 |
| Spectral Bandwidth | 48–73 nm |
| Frame Rate | up to 27 cubes/s |
| Instantaneous Field of View (IFOV) | 0.4–0.6 mrad @ 50 mm lens |
| Detector Pixel Pitch | 20–30 µm |
| Full-Well Capacity | 5–20 Me⁻ |
| Operating Temperature Range (for target emission) | up to 1250 °C |
| Software | HSAnalysis3 with real-time processing engine |
| Data Output Format | Standard ENVI-compatible .hdr/.dat, supports third-party analysis (MATLAB, Python, IDL) |
| Brand | SurfaceOptics |
|---|---|
| Origin | USA |
| Model | SOC710 SWIR |
| Spectral Range | 900–1700 nm |
| Spectral Resolution | 2.75 nm |
| Spatial Pixels | 640 × 568 |
| Spectral Bands | 288 |
| Digital Resolution | 14 bit |
| F-number | f/2.0 |
| Scan Method | Internal Translation-Based Pushbroom |
| Scan Rate | 60–120 lines/sec |
| Acquisition Time per Cube | ~10 s |
| Lens Options | 8 mm, 12.5 mm, 16 mm, 25 mm, 35 mm, 50 mm |
| Interface | USB |
| Power Supply | DC 12 V / AC 220 V |
| Brand | SurfaceOptics |
|---|---|
| Origin | USA |
| Model | SOC730VS |
| Spectral Range | 400–1000 nm |
| Spectral Resolution | 2 nm |
| Spatial Resolution | 1024 × 1024 pixels |
| Smile Error | <1.5 µm |
| f-number | f/2.4 |
| Total Field of View (35 mm lens) | 10° |
| Instantaneous Field of View (35 mm lens) | 0.17 mrad |
| Frame Rate | 15 fps |
| Digitization | 12-bit |
| Interface | Camera Link |
| Scan Mechanism | Integrated push-broom scanner |
| Power Supply | AC / 12 V DC |
| Tripod Mount | 3/8″–16 |
| Brand | SurfaceOptics |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SOC750 |
| Pricing | Upon Request |
| Spectral Range | 2–5 µm |
| Spectral Resolution | 48–97 nm |
| Frame Rate | Up to 15 hyperspectral cubes/s |
| Spatial Resolution Options | 256×240, 256×256, or 512×512 pixels |
| Bit Depth | 14-bit |
| Data Cube Size | 5.25 MB (HB), 4 MB (HS), 32 MB (HR) |
| Software | HSAnalysis3 v3.x |
| Brand | SurfaceOptics |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SOC750 |
| Pricing | Upon Request |
| Spectral Range | 2–5 µm |
| Spectral Resolution | 48–97 nm |
| Spatial Resolution Options | 256×240, 256×256, 512×512 pixels |
| Data Rate | Up to 15 hyperspectral cubes/sec |
| Bit Depth | 14-bit |
| Hyperspectral Cube Size | 5.25 MB to 32 MB |
| Software | HSAnalysis3 v4.x (GUI-based, real-time processing) |
| Brand | SurfaceOptics |
|---|---|
| Origin | USA |
| Model | SOC750MW |
| Operating Principle | Push-broom |
| Imaging Mode | 3D (hyperspectral data cube) |
| Platform | Ground-based |
| Spectral Range | 2–5 µm |
| Spectral Resolution | 48–73 nm |
| Instantaneous Field of View (IFOV) | 256 × 240 pixels |
| Frame Rate | 27 cubes/s |
| Detector Type | HgCdTe (MCT) or InSb focal plane array |
| Software | HSAnalysis3 (real-time processing, GUI-based calibration & analysis) |
| Brand | SurfaceOptics |
|---|---|
| Origin | USA |
| Model | SOC760 |
| Configuration | Ground-based, Portable |
| Spectral Range | 400–1000 nm & 1000–2500 nm |
| Spectral Resolution | 2.5 nm (VIS-NIR), 5 nm (SWIR) |
| Total Spectral Bands | 650 |
| Spatial Resolution (IFOV) | 650 × 2048 pixels |
| Field of View (TFOV) | 12.5° |
| Scanning Mechanism | Oscillating mirror pushbroom |
| Detector | Uncooled CMOS (VIS-NIR), Cooled InSb FPA (SWIR) |
| Data Acquisition Platform | Integrated laptop workstation with high-end GPU, multi-core CPU, and 2 TB SSD |
| Software | Custom GUI for radiometric calibration, geometric correction, and real-time data streaming |
| Compliance | Designed for ASTM E131, ISO 18359, and USP <857> spectral data integrity requirements |
| Recommended Post-Processing | ENVI, MATLAB, Python (scikit-learn, hylite) |
| Brand | SUERC |
|---|---|
| Origin | Germany |
| Model | SURRC PPSL |
| Background Count (20°C) | 50 cps (typ.), 150 cps (max) |
| Pulse Width | 15 µs |
| Preloaded Count | 256 counts |
| Median Threshold | 768 counts |
| Positive Threshold | 4096 counts |
| Preset Test Duration | 15 s |
| Brand | Sutter |
|---|---|
| Origin | USA |
| Model | BV-10 |
| Instrument Type | Microelectrode Processing System for Electrophysiology |
| Heating Elements | Pt/Ir wire and Sn-Pb alloy wire |
| Tip Diameter Capability | < 0.3 µm |
| Control | Triple independent digital controllers for heat, pull force, and timing |
| Microscopy | Integrated dual-magnification optical system (low- and high-power objectives) |
| Compliance | Designed for GLP-compliant electrophysiology lab workflows |
| Brand | Sutter Instrument |
|---|---|
| Origin | USA |
| Product Line | Capillary Glass & Filaments |
| Wall Type Options | Standard Wall, Thin Wall, Multibarrel, Quartz |
| Material | Borosilicate Glass (e.g., 7052, 7740) and Fused Quartz |
| Outer Diameter Range | 1.00–2.00 mm |
| Inner Diameter Range | 0.30–1.56 mm |
| Length Options | 7.5 cm, 10 cm, 15 cm |
| Packaging Quantities | 75–250 units per pack |
| Filament Availability | With or Without Internal Filament |
| Brand | Sutter |
|---|---|
| Origin | USA |
| Product Type | Replacement Filament Heating Elements |
| Compatible Models | P-1000, P-97, P-87, P80PC, P80C, PC-84, P-77B, P-30, P-2000, P-77A |
| Filament Types | Box (square), Trough (rectangular), Loop, Custom Pt/Ir, Nichrome |
| Dimensions Range | 1.5–4.5 mm width |
| Material Options | Kanthal A1, Nichrome, Platinum/Iridium alloy |
| Packaging | Minimum order quantity = 4 filaments |
| Brand | Sutter |
|---|---|
| Origin | USA |
| Model | MP85 / MP285 / MP-33 |
| Type | Electrochemical Sample Manipulator |
| Axes | 3–4 axis (manual or motorized) |
| Positioning Resolution | Down to 62.5 nm (MP-285/MP-225), 0.2 µm (MP-85 ultra-fine), 0.01 mm (MP-33 fine), 0.1 mm (coarse) |
| Drift | <10 nm/h (MP-285, 24°C), <1 µm/h (MPC-325-2/MPC-385-2) |
| Travel Range | Up to 25 mm (X/Y/Z/oblique), 1 inch (MP-285), 37 × 20 × 20 mm (MP-33 coarse) |
| Control Interface | RS-232 serial, software-driven (XenoWorks™ compatible) |
| Compliance | Designed for GLP/GMP-aligned electrophysiology and electrochemical microelectrode positioning |
| Brand | Sutter |
|---|---|
| Origin | USA |
| Model | MPC-200 / MPC-385 / MPC-325 |
| Drive Type | Motorized (DC servo) |
| Position Resolution | ≤ 10 nm (closed-loop) |
| Travel Range (X/Y/Z) | 25 mm × 25 mm × 25 mm (standard) |
| Repeatability | ±0.1 µm |
| Max Load Capacity | 250 g |
| Compatibility | Standard micropipette holders (e.g., Sutter MO-103, MO-203), compatible with upright & inverted microscopes |
| Interface | Analog voltage input (±10 V), RS-232, optional USB-to-serial adapter |
| Operating Temperature | 15–30 °C |
| Humidity | 20–80% RH (non-condensing) |
| Brand | Sutter |
|---|---|
| Origin | USA |
| Model | P-30 |
| Heating Element Options | Platinum-Iridium or Nichrome Coil |
| Control Interface | Three Digital Knobs (Heat, Pull, Velocity) |
| Precision Mechanism | Micrometer-Based Pull Length Reproducibility |
| Electrode Tip Diameter | Down to <0.3 µm |
| Power Supply | Constant-Current Source for Heater and Pull Solenoid |
| Dual-Step Heating Mode | Yes |
| RFI Filtering | Integrated |
| Mounting Base | Rubber-Pad Clamping System |
| Construction Materials | Corrosion-Resistant Alloys and Ceramics |
| Voltage/Frequency Options | Dual (115 V / 230 V |
| Application Domain | Intracellular Electrophysiology, Patch-Clamp Recording, Microinjection, Single-Cell Manipulation |
| Brand | Sutter |
|---|---|
| Origin | USA |
| Model | P97 |
| Instrument Type | Electrochemical Micropipette Fabrication System |
| Heating Element | Dual-Loop Resistive Wire (NiChrome or Platinum) |
| Control Architecture | Embedded Microprocessor with Non-Volatile Program Memory |
| Max. Program Storage | 100 Protocols |
| Display | Vacuum Fluorescent Display (VFD), Omnidirectional View |
| Environmental Control | Integrated Humidity-Stabilized Chamber |
| Cooling Options | Pneumatic Blast Cooling (Selectable Mode) |
| Glass Compatibility | Single- and Multi-Barrel Capillaries (OD up to 2.0 mm) |
| Tip Diameter Resolution | Sub-100 nm (Typical for Borosilicate & Aluminosilicate Glass) |
| Compliance | Designed for GLP/GMP-Adjacent Electrophysiology Labs |
| Software Features | Date/Time-Stamped Protocol Logging, Write-Protected Program Mode, Atmospheric Pressure Compensation Parameter |
| Brand | Sutter |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | XenWorks |
| Pricing | Upon Request |
| Brand | Swamp Optics |
|---|---|
| Origin | USA |
| Model | Grenouille 8-20-USB |
| Spectral Range | 50–400 nm |
| Spectral Resolution | 0.7 nm |
| Spatial Resolution | 480 × 640 pixels |
| Field of View (TFOV) | 5° |
| Instantaneous Field of View (IFOV) | 0.01 rad |
| Frame Rate | 330 fs |
| Imaging Modality | 3D |
| Operating Mode | Airborne-mounted |
| Compliance | ASTM E2912, ISO/IEC 17025-compatible data acquisition architecture |
| Key Specifications | Origin: USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | SWIR Short-Wave Infrared Spectrometer |
| Pricing | Upon Technical Consultation |
| Brand | Sykam |
|---|---|
| Origin | Germany |
| Model | S-150 |
| Instrument Type | Laboratory |
| Pump Pressure Range | 0–40 MPa |
| Flow Rate Range | 0.000–10.000 mL/min |
| Eluent Flow Rate Range | 0.000–10.000 mL/min |
| Maximum Operating Pressure | 35 MPa |
| Operating Temperature Range | 5–35 °C |
| Temperature Reproducibility | ±0.01 °C |
| Eluent Concentration Range | Application-dependent (compatible with common carbonate/bicarbonate, hydroxide, methanesulfonic acid, and other IC eluents) |
| Brand | Sykam |
|---|---|
| Origin | Germany |
| Model | S-3115 |
| Detection Principle | Bipolar Pulsed Electrode Conductivity Measurement |
| Measuring Range | 0.05–10,000 µS |
| Rise Time | 0–10 s |
| Cell Volume | 0.2 µL |
| Temperature Control Range | Ambient to 85 °C |
| Temperature Stability | ±0.01 °C |
| Signal Offset Adjustment | 0–20% of full scale |
| Digital Signal Smoothing | Enabled |
| Auto-zero Function | Supported |
| External Control Interface | Analog (0–10 V) and RS232 |
| Dimensions | 330 × 220 × 160 mm |
| Weight | ~8 kg |
| Brand | Sykam |
|---|---|
| Origin | Germany |
| Model | S-3210, S-3210S, S-3210DAD, S-3240, S-3240DAD |
| Wavelength Range | 190–720 nm |
| Spectral Bandwidth | 6 nm (2 nm per diode) |
| Noise | ±1.5 × 10⁻⁵ AU |
| Drift | 5 × 10⁻⁵ AU/h |
| Wavelength Accuracy | ±0.5 nm |
| Absorbance Range | 0.0005–2.0 AU (full scale, 8 selectable ranges) |
| Flow Cell | PEEK, 10 mm path length, 12 µL volume |
| Scan Speed | 0.1 s for full 190–720 nm spectrum |
| Analog Outputs | 4 channels (0–1.0 V, full-scale matched to absorbance range) |
| Interface | RS232 |
| Detector Type | Diode Array Detector (DAD) or Programmable Single-Channel UV-Vis |
| Brand | Sykam |
|---|---|
| Origin | Germany |
| Model | S-3580 |
| Refractive Index Range | 1.00–1.75 RIU |
| Flow Rate Range | 0.2–3.0 mL/min (analytical/micro), 1.0–50 mL/min (semi-preparative) |
| Linear Range | 0–500, 0–1,000, or 0–20,000 µRIU |
| Noise Level | 5×10⁻⁹ to 10×10⁻⁸ RIU |
| Drift | <1 mV/h (at 1.0 mL/min, H₂O) |
| Cell Volume | 4 µL, 7 µL, or 9 µL |
| Cell Angle | 45° or 5° |
| Maximum Pressure Rating | 6 kg/cm² |
| Dead Volume | 6 µL, 24 µL, or 88/353 µL |
| Temperature Control | Ambient, 35–55 °C (1 °C increments) |
| Response Time Options | 0 s (real-time), 0.4 s, 0.8 s, 1.2 s |
| Output | ±1 V analog |
| Interface Frequency | 1 Hz or 10 Hz |
| Housing Dimensions | 220 × 350 × 155 mm |
| Weight | ~11 kg |
| Brand | Sykam |
|---|---|
| Origin | Germany |
| Model | S-433D |
| Instrument Type | Post-column Derivatization Amino Acid Analyzer |
| Pump Flow Rate | 0.000–9.999 mL/min |
| Maximum Pump Pressure | 40 MPa (400 bar, 6000 psi) |
| Autosampler Injection Volume | 1–500 µL |
| Autosampler Temperature Control | +4 °C to 70 °C (electronic thermostating) |
| Post-column Reactor Temperature Range | Ambient to 180 °C (temperature stability ±0.1 °C) |
| Detection Wavelengths | Simultaneous dual-wavelength detection at 570 nm and 440 nm |
| Flow Cell Volume | 8 µL |
| Brand | Sykam |
|---|---|
| Origin | Germany |
| Model | S-501 |
| Instrument Type | Conventional High-Performance Liquid Chromatograph |
| Flow Rate Range | 0.001–10.000 mL/min |
| Maximum Pressure | 40 MPa |
| Autosampler Capacity | 120 positions |
| Injection Volume Range | 0.1–999.9 µL |
| Column Oven Temperature Range | 4–100 °C |
| UV/Vis Wavelength Range | 190–800 nm |
| Data Acquisition Rate | 10 Hz |
| Brand | Sykam |
|---|---|
| Origin | Germany |
| Model | S-504 |
| Instrument Type | Conventional High-Performance Liquid Chromatograph |
| Flow Rate Range | 0.001–10.000 mL/min |
| Maximum Pressure | 40 MPa |
| Autosampler Capacity | 60 positions × 1.5 mL vials or 96 positions × 0.5 mL vials |
| Injection Volume Range | 0.1–999.9 µL |
| Column Oven Temperature Range | 4–100 °C |
| UV/Vis Wavelength Range | 190–800 nm |
| Data Acquisition Rate | 10 Hz |
| Brand | Sykam |
|---|---|
| Origin | Germany |
| Model | S433D |
| Instrument Type | Post-Column Derivatization System |
| Pump Flow Rate | 0–9.999 mL/min |
| Maximum Pump Pressure | 40 MPa |
| Autosampler Injection Volume | 0–500 µL |
| Autosampler Temperature Control | +5 °C to 70 °C (electronic thermostating) |
| Post-Column Reactor Temperature Range | Ambient to 180 °C |
| Detection Wavelengths | 570 nm and 440 nm |
| Flow Cell Volume | 8 µL |
| Brand | Sykam |
|---|---|
| Origin | Germany |
| Model | S5200 |
| Instrument Type | HPLC Autosampler |
| Sample Capacity | 120 vials (2 × 60-position trays) |
| Standard Loop Volume | 20 µL (exchangeable) |
| Precision | RSD < 0.5% (fixed-volume mode) |
| Carryover | < 0.01% (low-pressure wash) |
| Programmable Wash Protocol | Yes |
| Control Interface | Analog signal or RS-232 digital |
| Dimensions | 415 × 300 × 445 mm |
| Weight | ~20 kg |
| Brand | Synpec |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Instrument Type | Flame AAS |
| Model | AA3510 |
| Wavelength Range | 190–900 nm |
| Light Source | 4/6-lamp turret |
| Wavelength Repeatability | ±0.1 nm |
| Wavelength Accuracy | ±0.2 nm across full range |
| Spectral Bandwidth Options | 0.1, 0.2, 0.4, 1.0, 1.2, 2.0 nm |
| Resolution | 0.2 nm (resolves Mn doublet at 279.5/279.8 nm, valley-to-peak energy ratio <30%) |
| Monochromator | Plane grating (1800 lines/mm) |
| Optical System | Single-beam |
| Detector | Photomultiplier tube (PMT) |
| Background Correction | D₂ lamp + self-absorption method |
| Background Correction Capacity | ≥50× at 1 ABS background signal |
| Static Baseline Drift | ≤0.002 ABS/30 min (Cu) |
| Dynamic Baseline Drift (ignition) | ≤0.004 ABS/30 min (Cu) |
| Sensitivity | ≤0.025 µg/mL for 1% absorption |
| Detection Limit (Cu) | ≤0.006 µg/mL |
| Precision (RSD) | ≤0.5% (Cu, A > 0.8 ABS) |
| Flame Systems | Air–acetylene (100 mm burner head) |
| Safety Features | Automatic gas cutoff on low pressure, power interruption, flameout, or burner mismatch |
| Dimensions | 700 × 500 × 430 mm |
| Weight | 80 kg |
| Power Supply | 220 V AC |
| Brand | Synpec |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Flame AAS |
| Monochromator | Plane Grating |
| Optical System | Single-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | D₂ Lamp + Self-Absorption Method |
| Spectral Resolution | 0.2 nm |
| Sensitivity | ≤0.025 µg/mL for 1% absorption |
| RSD (Precision) | ≤0.5% |
| Cu Detection Limit | ≤0.006 µg/mL |
| Wavelength Range | 190–900 nm |
| Wavelength Accuracy | ±0.2 nm across full range |
| Wavelength Repeatability | ±0.1 nm |
| Spectral Bandwidth Options | 0.1, 0.2, 0.4, 1.0, 1.2, 2.0 nm |
| Baseline Drift (Static) | ≤0.002 ABS/30 min (Cu) |
| Baseline Drift (Dynamic, Ignition) | ≤0.004 ABS/30 min (Cu) |
| Mn Doublet Resolution | Resolves 279.5/279.8 nm with valley-to-peak energy ratio <30% at 0.2 nm SBW |
| Lamp Holder | 4-lamp turret (6-lamp optional) |
| Flame Burner Heads | 100 mm air–acetylene |
| Safety Interlocks | Automatic gas cutoff on low pressure, power failure, flameout, or burner mismatch |
| Dimensions | 700 × 500 × 430 mm |
| Weight | 80 kg |
| Grating Density | 1800 lines/mm |