Circulating Chiller
Filter
Showing 151–180 of 481 results
| Brand | JULABO |
|---|---|
| Origin | Germany |
| Model | SC2500a |
| Cooling Method | Air-Cooled |
| Temperature Range | −20 to +80 °C |
| Cooling Capacity | 2500 W |
| Temperature Stability | ±0.1 °C |
| Circulation Pump Pressure | 3.5 bar |
| Circulation Flow Rate | 33 L/min |
| Reservoir Volume | 21–33 L |
| Operating Mode | Continuous |
| Heating Power | 0 kW (Standard), Optional up to 12 kW |
| Refrigerant Type | Environmentally Compliant HFC (R-410A or equivalent) |
| Communication Interface | RS232 |
| External Pt100 Input | Integrated |
| Sound Pressure Level | ≤65 dB(A) |
| Safety Classification | DIN 12876-1 Class III (FL) |
| Enclosure Rating | IP20 |
| Brand | JULABO |
|---|---|
| Origin | Germany |
| Model | SC5000a |
| Cooling Method | Air-Cooled |
| Temperature Range | -20 to +130 °C |
| Cooling Capacity | 5000 W |
| Temperature Stability | ±0.1 °C |
| Circulation Pump Pressure | 4.3 bar |
| Circulation Flow Rate | 33 L/min |
| Reservoir Volume | 43–60 L |
| Operation Mode | Continuous |
| Brand | JULABO |
|---|---|
| Origin | Germany |
| Model | SC5000w |
| Cooling Method | Water-cooled |
| Temperature Range | -20 to +130 °C |
| Cooling Capacity | 5000 W |
| Temperature Stability | ±0.1 °C |
| Circulation Pump Pressure | 4.3 bar |
| Circulation Flow Rate | 33 L/min |
| Reservoir Volume | 43–60 L |
| Operating Mode | Continuous |
| Heating Power (Optional) | Up to 12 kW |
| Communication Interface | RS232 (optional), Profibus (optional) |
| Compressor Cooling | Water-cooled |
| Safety Classification | DIN 12876-1 Class III (FL) |
| External PT100 Sensor Input | Integrated |
| Brand | JULABO |
|---|---|
| Origin | Germany |
| Model | SC Series |
| Cooling Method | Water-Cooled |
| Temperature Range | -20 to +130 °C |
| Temperature Stability | ±0.1 °C |
| Circulating Pump Pressure | 4.3 bar |
| Circulating Pump Flow Rate | 33 L/min |
| Reservoir Volume | 21–60 L |
| Operating Mode | Continuous |
| Heating Power | Up to 12 kW |
| Refrigeration Power | Up to 10 kW |
| Construction | Stainless Steel & Chemically Resistant Polymers |
| Compliance | CE, RoHS, ISO 9001 Certified |
| Brand | JULABO |
|---|---|
| Origin | Germany |
| Model | Semichill SC2500a |
| Cooling Type | Water-Cooled |
| Temperature Range | −20 °C to +130 °C |
| Refrigeration Capacity | 2500 W |
| Temperature Stability | ±0.1 °C |
| Circulation Pump Pressure | 4.3 bar |
| Circulation Pump Flow Rate | 43 L/min |
| Reservoir Volume | 33 L |
| Operation Mode | Continuous |
| Enclosure Classification | DIN 12876-1 Class III (FL) |
| Compressor Cooling Method | Water-Cooled |
| Integrated Pt100 Sensor Interface | Yes |
| Communication Interface | RS232 (optional), Profibus (optional) |
| Brand | JULABO |
|---|---|
| Origin | Germany |
| Model | SC2500w |
| Cooling Method | Water-Cooled |
| Temperature Range | −20 to +80 °C |
| Cooling Capacity | 2500 W |
| Temperature Stability | ±0.1 °C |
| Circulation Pump Pressure | 3.5 bar |
| Circulation Flow Rate | 33 L/min |
| Reservoir Volume | 21–33 L |
| Operating Mode | Continuous |
| Refrigeration Compressor Type | Water-Cooled |
| External Pt100 Sensor Input | Integrated |
| Communication Interface | RS232 (optional), Profibus (optional) |
| Sound Pressure Level | ≤63 dB(A) |
| Classification per DIN 12876-1 | Class III (FL) |
| Ambient Operating Temperature | 5–40 °C |
| Dimensions (W×L×H) | 49 × 62 × 105 cm |
| Weight | 123 kg |
| Pump Connection | NPT 3/4″ |
| Internal Tubing ID | 3/4″ |
| Brand | LabS |
|---|---|
| Origin | Guangdong, China |
| Model | FL-0904A / FL-1105A |
| Instrument Type | Integrated Circulating Chiller |
| Cooling Method | Water-Cooled |
| Temperature Range | 5–40 °C |
| Temperature Stability | ±0.5 °C |
| Refrigeration Capacity | 1600–2700 W |
| Circulating Pump Pressure | 1.0 bar |
| Circulating Pump Flow Rate | 42 L/min |
| Reservoir Volume | 8.5 L |
| Heat Exchanger Material | Stainless Steel |
| Compressor | Premium Industrial-Grade |
| Refrigerant Option | R134a or Eco-Friendly Alternative (Optional) |
| Noise Level | Low-Noise Operation |
| Control System | Microprocessor-Based Digital Controller |
| Dual-Circuit Capability | Internal + External Loop Support |
| Remote Control Interface | Optional 0–10 V or Dry Contact Input |
| Brand | LabTech |
|---|---|
| Origin | Beijing, China |
| Model | H35 |
| Instrument Type | Integrated Circulating Chiller |
| Cooling Method | Water-Cooled |
| Temperature Range | −5 to 35 °C |
| Cooling Capacity | 350 W (at 20 °C ambient) / 500 W (at 25 °C ambient) |
| Temperature Stability | ±0.3 °C |
| Circulation Pump Pressure | 1.0 bar |
| Circulation Flow Rate | 3.5 L/min |
| Reservoir Volume | 1.8 L |
| Operation Mode | Continuous |
| Control Technology | PID Digital Temperature Control + Hot Gas Bypass Compressor Modulation |
| Heat Exchanger | Plate-Type |
| Refrigerant | R134a (CFC-free, ozone-friendly) |
| Display | Backlit LCD |
| Brand | LabTech |
|---|---|
| Model | H35 |
| Type | Integrated Circulating Chiller |
| Cooling Method | Water-Cooled |
| Temperature Range | –5 to 35 °C |
| Temperature Stability | ±0.3 °C |
| Refrigeration Capacity | 350 W / 500 W |
| Circulation Pump Pressure | 1.0 bar |
| Flow Rate | 3.5 L/min |
| Reservoir Volume | 1.8 L |
| Operation Mode | Continuous |
| Control Technology | PID + Hot Gas Bypass |
| Heat Exchanger | Plate-Type |
| Refrigerant | R134a (CFC-free) |
| Power Consumption | Optimized for low-energy continuous operation |
| Compliance | Designed per IEC 61000-6-3 (EMC), IEC 61010-1 (Safety), and ISO 9001 manufacturing standards |
| Brand | LabTech |
|---|---|
| Origin | Beijing, China |
| Model | H500 |
| Instrument Type | Integrated Circulating Chiller |
| Cooling Method | Water-Cooled |
| Temperature Stability | ±0.2 °C |
| Design Architecture | Separated Refrigeration and Heat Dissipation Units |
| Low-Temperature Operation Capability | Functional at outdoor ambient temperatures down to −25 °C |
| Control Interface | Full-Color Touchscreen with Real-Time Multi-Parameter Display |
| Safety System | 13 Diagnostic Alarm Codes |
| Operational Flexibility | 12 Configurable System Parameter Sets |
| Hot Gas Bypass Technology | Integrated |
| PID Digital Temperature Control | Standard |
| Brand | LabTech |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | LCW-4000 Series |
| Instrument Type | Integrated Circulating Chiller |
| Cooling Method | Water-Cooled |
| Temperature Control Range | 8–35 °C |
| Refrigeration Capacity | 1.2–5.0 kW |
| Temperature Stability | ±0.2 °C |
| Circulation Pump Pressure | 4.0 bar |
| Circulation Flow Rate | 17.1 L/min |
| Reservoir Volume | 20–40 L |
| Operating Mode | Continuous Duty |
| Brand | LabTech |
|---|---|
| Origin | Beijing, China |
| Instrument Type | Integrated Circulating Chiller |
| Cooling Method | Water-Cooled |
| Temperature Control Range | –40 °C to +100 °C |
| Temperature Stability | ±0.05 °C (at setpoint, under stabilized conditions) |
| Bath Material | Seamless 304 Stainless Steel |
| Interface | RS485 for Remote Monitoring and Control |
| Safety Features | Dual High/Low Temperature Alarm, Low-Level Liquid Alarm |
| Circulation Mode | Switchable Internal/External Loop via Manual Knob |
| Power Supply | 220–240 VAC, 50/60 Hz |
| Brand | LabTech |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | SH150-3000 |
| Temperature Control Range | 8–35 °C |
| Cooling Capacity | 3000 W |
| Temperature Stability | ±0.1 °C |
| Circulation Pump Flow Rate | 12.1 L/min @ 4 bar |
| Reservoir Volume | 3.5 L |
| Brand | LabTech |
|---|---|
| Origin | Beijing, China |
| Model | SMART Series |
| Instrument Type | Integrated Circulating Chiller |
| Cooling Method | Air-Cooled |
| Temperature Range | 8–35 °C (Low-Temperature Models: −20 to 35 °C) |
| Refrigeration Capacity | 1000 W (@25 °C ambient) |
| Temperature Stability | ±0.1 °C |
| Circulation Pump Pressure | 3 bar (43.5 psi) |
| Flow Rate | 6.4 L/min |
| Reservoir Volume | ~5 L |
| Operating Mode | Continuous Duty (Hot Gas Bypass Control) |
| Brand | LabTech |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | SMART Series |
| Instrument Type | Integrated Unit |
| Cooling Method | Water-Cooled |
| Temperature Control Range | 8–35 °C |
| Cooling Capacity | 700–3000 W |
| Temperature Stability | ±0.1 °C |
| Circulation Pump Pressure | 1.0–6.0 bar |
| Circulation Flow Rate | 3.5–12.1 L/min |
| Reservoir Volume | 1.8–3.5 L |
| Operation Mode | Continuous |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Model | Integral 280 XTW |
| Cooling Method | Water-cooled |
| Temperature Range | –80 to +220 °C |
| Cooling Capacity | 9000 W |
| Temperature Stability | ±0.05 K |
| Circulation Pump Pressure | 3.1 bar |
| Circulation Flow Rate | 65 L/min |
| Reservoir Volume | 4.8–17.2 L |
| Operation Mode | Continuous |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Model | IN 2050 PW |
| Instrument Type | Integrated Circulating Chiller |
| Cooling Method | Water-Cooled |
| Temperature Range | –40 to +140 °C |
| Refrigeration Capacity | 15,000 W |
| Temperature Stability | ±0.05 °C |
| Pump Pressure | 6.0 bar |
| Pump Flow Rate | 120 L/min |
| Reservoir Volume | 11.1–36.3 L |
| Operating Mode | Continuous |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Model | IN 230 TW |
| Instrument Type | Integrated Circulating Chiller |
| Cooling Method | Water-Cooled |
| Temperature Range | –30 to 120 °C |
| Refrigeration Capacity | 2300 W |
| Temperature Stability | ±0.05 °C |
| Pump Pressure | 3.5 bar |
| Pump Flow Rate | 40 L/min |
| Reservoir Volume | 3.6–8.7 L |
| Operating Mode | Continuous |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Model | IN 150 XT |
| Cooling Method | Air-Cooled |
| Temperature Range | -45 to 220 °C |
| Cooling Capacity | 1.5 kW (at 20 °C, Pump Level 8) |
| Temperature Stability | ±0.05 °C |
| Pump Pressure | 3.1 bar |
| Pump Flow Rate | 65 L/min |
| Reservoir Volume | 2.5–8.7 L |
| Operating Mode | Continuous |
| Heater Power | 3.5 kW |
| Max. Power Consumption | 3.7 kW |
| Noise Level | 60 dB(A) |
| Net Weight | 103 kg |
| Dimensions (W×D×H) | 430 × 550 × 760 mm |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Model | IN 1590 XTW |
| Cooling Method | Water-Cooled |
| Temperature Range | −90 °C to 220 °C |
| Refrigeration Capacity | 18.5 kW |
| Temperature Stability | ±0.05 °C |
| Circulation Pump Pressure | 3.1 bar |
| Circulation Flow Rate | 65 L/min |
| Bath Volume | 30.6 L |
| Operating Mode | Continuous |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Model | IN 1850 XTW |
| Cooling Method | Water-Cooled |
| Temperature Range | –50 °C to +220 °C |
| Refrigeration Capacity | 20,000 W |
| Temperature Stability | ±0.05 °C |
| Circulating Pump Pressure | 6.0 bar |
| Circulating Pump Flow Rate | 120 L/min |
| Bath Volume | 8.0–28.6 L |
| Operation Mode | Continuous |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Model | IN 550XTW |
| Cooling Method | Water-Cooled |
| Temperature Range | −50 °C to 220 °C |
| Cooling Capacity | 5800 W |
| Temperature Stability | ±0.05 °C |
| Pump Pressure | 3.1 bar |
| Pump Flow Rate | 65 L/min |
| Reservoir Volume | 4.8–17.2 L |
| Operation Mode | Continuous |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Model | IN 950 XTW |
| Cooling Method | Water-Cooled |
| Temperature Range | -50 °C to 220 °C |
| Refrigeration Capacity | 9500 W |
| Temperature Stability | ±0.05 °C |
| Circulation Pump Pressure | 3.1 bar |
| Circulation Flow Rate | 65 L/min |
| Reservoir Volume | 4.8–17.2 L |
| Operation Mode | Continuous |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Model | LOOP 100 |
| Instrument Type | Integrated Circulating Chiller |
| Cooling Method | Air-Cooled |
| Temperature Range | 4–80 °C |
| Refrigeration Capacity | 60 W (at 10 °C output) |
| Temperature Stability | ±0.1 °C |
| Circulation Pump Pressure | 0.8 bar |
| Circulation Flow Rate | 2.6 L/min |
| Bath Volume | 0.28 L |
| Operating Mode | Continuous |
| Display | High-Contrast OLED Graphic Screen |
| Interface | RS232 |
| Power Supply | 100–240 V, 50/60 Hz |
| Max. Power Consumption | 0.24 kW |
| Dimensions (W×D×H) | 175 × 301 × 266 mm |
| Net Weight | 6.5 kg |
| Noise Level | 57 dB(A) |
| Fluid Compatibility | Water, Water/Ethylene Glycol Mixtures (Non-Flammable Only) |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Model | LOOP 250 |
| Instrument Type | Integrated Circulating Chiller |
| Cooling Method | Air-Cooled |
| Temperature Range | 4–80 °C |
| Refrigeration Capacity | 130 W (at 10 °C output) |
| Temperature Stability | ±0.1 °C |
| Circulation Pump Pressure | 0.8 bar |
| Circulation Flow Rate | 2.6 L/min |
| Bath Volume | 0.32 L |
| Operating Mode | Continuous |
| Heating Power | 400 W |
| Pump Max Flow (at zero head) | 3 L/min |
| Dimensions (W×D×H) | 261 × 368 × 312 mm |
| Weight | 12 kg |
| Noise Level | 57 dB(A) |
| Power Supply | 100–240 V, 50/60 Hz |
| Protection Class | IP20 |
| Fluid Compatibility | Water, Water/Glycol Mixtures (non-flammable) |
| Interface | RS232 |
| Display | High-contrast OLED Graphical Screen |
| Control Interface | 3-button intuitive navigation |
| Connection | Quick-release 1/4″ C-type fittings |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Model | Microcool |
| Instrument Type | Integrated Circulating Chiller |
| Cooling Method | Water-Cooled |
| Temperature Range | –10 °C to +50 °C |
| Refrigeration Capacity | 1200 W |
| Temperature Stability | ±0.5 K |
| Circulation Pump Pressure | 1.3 bar |
| Circulation Flow Rate | 35 L/min |
| Reservoir Volume | 7 L |
| Operating Mode | Continuous |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Model | MC 1200 |
| Cooling Method | Air-Cooled |
| Temperature Range | –10 to +40 °C |
| Refrigeration Capacity | 1.20 kW at 20 °C (Ethanol) |
| Temperature Stability | ±0.5 °C |
| Pump Pressure | Up to 1.3 bar |
| Pump Flow Rate | 35 L/min |
| Reservoir Volume | 14.0 L |
| Operating Mode | Continuous |
| Power Supply | 230 V, 50 Hz |
| Refrigerant | R-134a (0.575 kg) |
| Dimensions (W × D × H) | 450 × 550 × 650 mm |
| Weight | 63 kg |
| Sound Pressure Level | 59 dB(A) |
| Max. Power Consumption | 1.15 kW |
| Max. Current | 6.5 A |
| Inlet/Outlet Thread | G 3/4" |
| Minimum Fill Volume | 7 L |
| Maximum Fill Volume | 14 L |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Model | MC 250 |
| Cooling Method | Air-Cooled |
| Temperature Range | –10 to 40 °C |
| Refrigeration Capacity | 0.25 kW at 20 °C (ethanol) |
| Temperature Stability | ±0.5 K |
| Pump Max. Pressure | 0.35 bar |
| Pump Flow Rate | 16 L/min |
| Reservoir Volume | 2.0–4.0 L |
| Power Supply | 230 V, 50 Hz |
| Refrigerant | R-134a (0.085 kg) |
| Dimensions (W×D×H) | 200 × 350 × 465 mm |
| Weight | 25 kg |
| Noise Level | 60 dB(A) |
| Max. Power Consumption | 0.23 kW |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Model | MC 350 |
| Cooling Method | Air-Cooled |
| Temperature Range | −10 to 40 °C |
| Cooling Capacity | 0.35 kW (at 20 °C with ethanol) |
| Temperature Stability | ±0.5 K |
| Pump Pressure | up to 0.35 bar |
| Pump Flow Rate | 16 L/min |
| Reservoir Volume | 4.0–7.0 L |
| Power Supply | 230 V, 50 Hz |
| Refrigerant | R-134a (0.095 kg) |
| Noise Level | 60 dB(A) |
| Dimensions (W×D×H) | 240 × 400 × 500 mm |
| Weight | 34 kg |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Model | MC 600 |
| Cooling Method | Air-Cooled |
| Temperature Range | −10 to 40 °C |
| Refrigeration Capacity | 0.60 kW at 20 °C (Ethanol) |
| Temperature Stability | ±0.5 °C |
| Pump Pressure | up to 1.3 bar |
| Pump Flow Rate | 35 L/min |
| Reservoir Volume | 4.0–8.0 L |
| Power Supply | 230 V, 50 Hz |
| Refrigerant | R-134a (0.295 kg) |
| Dimensions (W×D×H) | 240 × 400 × 500 mm |
| Weight | 50 kg |
| Noise Level | 57 dB(A) |
| Max. Power Consumption | 0.7 kW |