Circulating Chiller
Filter
Showing 181–210 of 528 results
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Model | MC 1200 |
| Cooling Method | Air-Cooled |
| Temperature Range | –10 to +40 °C |
| Refrigeration Capacity | 1.20 kW at 20 °C (Ethanol) |
| Temperature Stability | ±0.5 °C |
| Pump Pressure | Up to 1.3 bar |
| Pump Flow Rate | 35 L/min |
| Reservoir Volume | 14.0 L |
| Operating Mode | Continuous |
| Power Supply | 230 V, 50 Hz |
| Refrigerant | R-134a (0.575 kg) |
| Dimensions (W × D × H) | 450 × 550 × 650 mm |
| Weight | 63 kg |
| Sound Pressure Level | 59 dB(A) |
| Max. Power Consumption | 1.15 kW |
| Max. Current | 6.5 A |
| Inlet/Outlet Thread | G 3/4" |
| Minimum Fill Volume | 7 L |
| Maximum Fill Volume | 14 L |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Model | MC 250 |
| Cooling Method | Air-Cooled |
| Temperature Range | –10 to 40 °C |
| Refrigeration Capacity | 0.25 kW at 20 °C (ethanol) |
| Temperature Stability | ±0.5 K |
| Pump Max. Pressure | 0.35 bar |
| Pump Flow Rate | 16 L/min |
| Reservoir Volume | 2.0–4.0 L |
| Power Supply | 230 V, 50 Hz |
| Refrigerant | R-134a (0.085 kg) |
| Dimensions (W×D×H) | 200 × 350 × 465 mm |
| Weight | 25 kg |
| Noise Level | 60 dB(A) |
| Max. Power Consumption | 0.23 kW |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Model | MC 350 |
| Cooling Method | Air-Cooled |
| Temperature Range | −10 to 40 °C |
| Cooling Capacity | 0.35 kW (at 20 °C with ethanol) |
| Temperature Stability | ±0.5 K |
| Pump Pressure | up to 0.35 bar |
| Pump Flow Rate | 16 L/min |
| Reservoir Volume | 4.0–7.0 L |
| Power Supply | 230 V, 50 Hz |
| Refrigerant | R-134a (0.095 kg) |
| Noise Level | 60 dB(A) |
| Dimensions (W×D×H) | 240 × 400 × 500 mm |
| Weight | 34 kg |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Model | MC 600 |
| Cooling Method | Air-Cooled |
| Temperature Range | −10 to 40 °C |
| Refrigeration Capacity | 0.60 kW at 20 °C (Ethanol) |
| Temperature Stability | ±0.5 °C |
| Pump Pressure | up to 1.3 bar |
| Pump Flow Rate | 35 L/min |
| Reservoir Volume | 4.0–8.0 L |
| Power Supply | 230 V, 50 Hz |
| Refrigerant | R-134a (0.295 kg) |
| Dimensions (W×D×H) | 240 × 400 × 500 mm |
| Weight | 50 kg |
| Noise Level | 57 dB(A) |
| Max. Power Consumption | 0.7 kW |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Model | RP 240 EC |
| Instrument Type | Integrated Circulating Chiller |
| Cooling Method | Hybrid (Air- and Water-Cooled) |
| Temperature Range | -40 to 200 °C |
| Cooling Capacity | 600 W at 20 °C |
| Temperature Stability | ±0.05 K |
| Pump Pressure | 0.68 bar |
| Pump Flow Rate | 22 L/min |
| Reservoir Volume | 2.4–4.4 L |
| Internal Fill Volume | Minimal (Optimized for Rapid Thermal Response) |
| Refrigerant | R-449A (GWP 1397, compliant with EU Regulation (EU) No 517/2014) |
| Power Supply | 230 V, 50 Hz |
| Max. Power Consumption | 3.7 kW |
| Dimensions (W×D×H) | 300 × 430 × 675 mm |
| Weight | 40 kg |
| Compliance | DIN 12876 Class I |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Model | RP 245 EC |
| Instrument Type | Integrated Circulating Chiller |
| Cooling Method | Hybrid (Air- and Water-Cooled) |
| Temperature Range | -45 to 200 °C |
| Cooling Capacity | 800 W at 20 °C |
| Temperature Stability | ±0.05 K |
| Circulating Pump Pressure | 0.68 bar |
| Circulating Pump Flow Rate | 22 L/min |
| Reservoir Volume | 2.4–4.4 L |
| Internal Fill Volume | Minimal (Optimized for Rapid Thermal Response) |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Model | RP 250 EC |
| Cooling Method | Hybrid (Air- and Water-Cooled) |
| Temperature Range | -50 to 200 °C |
| Temperature Stability | ±0.05 K |
| Refrigeration Capacity | 1.5 kW |
| Pump Pressure | 0.68 bar |
| Pump Flow Rate | 22 L/min |
| Bath Volume | 2.4–4.4 L |
| Heating Power | 2.5 kW |
| Internal Fill Volume | Minimal (Optimized for Rapid Thermal Response) |
| Refrigerant | R-452A (GWP 2140, compliant with EU Regulation (EU) No 517/2014) |
| Compliance | DIN 12876 Class I |
| Dimensions (W×D×H) | 300 × 430 × 675 mm |
| Weight | 48 kg |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Model | RP 290 EC |
| Cooling Method | Hybrid (Air- and Water-Cooled) |
| Temperature Range | –90 °C to +200 °C |
| Cooling Capacity | 800 W at 20 °C |
| Temperature Stability | ±0.05 °C |
| Circulating Pump Pressure | 0.68 bar |
| Flow Rate | 22 L/min |
| Reservoir Volume | 2.4–4.4 L |
| Heating Power | 2.5 kW |
| Max. Power Consumption | 3.7 kW |
| Refrigerants | R-452A (0.300 kg, GWP 2140) & R-170 (0.070 kg, GWP 3) |
| Compliance | DIN 12876, EU F-Gas Regulation (EU) No. 517/2014 |
| Interface Options | USB, Ethernet, RS-232/485, Profibus, EtherCAT, Analog I/O |
| Pump Type | LAUDA Varioflex (8-stage adjustable, pressure/suction capable) |
| Display | 5.7″ multi-touch color LCD |
| Programmability | 100 programs × 50 segments |
| User Management | Up to 20 users |
| Safety | Adjustable overtemperature protection with acoustic alarm |
| Dimensions (W×D×H) | 390 × 600 × 685 mm |
| Weight | 80 kg |
| Brand | LAUDA |
|---|---|
| Origin | USA |
| Model | Semistat S 2400 |
| Instrument Type | Split-System |
| Cooling Method | Water-Cooled |
| Temperature Range | -20 °C to 90 °C |
| Cooling Capacity | 2.45 kW |
| Temperature Stability | ±0.1 °C |
| Circulating Pump Pressure | 2.8 bar |
| Circulating Pump Flow Rate | 22 L/min |
| Reservoir Volume | 1.60 L |
| Operating Mode | Continuous Water Cooling |
| Heating Power (Min) | 6 kW |
| Minimum Fill Volume | 1.25 L |
| Maximum Fill Volume | 1.6 L |
| Dimensions (W×D×H) | 116 mm × 300 mm × 560 mm |
| Weight | 25 kg |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Model | UC 100 |
| Type | Split-System Circulating Chiller |
| Cooling Method | Water-Cooled |
| Temperature Control Range | −10 to 35 °C |
| Refrigeration Capacity | 100.0 kW (at 10 °C outlet water temperature) |
| Temperature Stability | ±0.5 °C |
| Circulation Pump Pressure | 5.4 bar |
| Circulation Flow Rate | 300 L/min |
| Reservoir Volume | 125 L |
| Operation Mode | Continuous |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Model | UC 14 |
| Type | Split-System Circulating Chiller |
| Cooling Method | Water-Cooled |
| Temperature Range | –10 to 35 °C |
| Temperature Stability | ±0.5 °C |
| Refrigeration Capacity | 15.8 kW (at 10 °C outlet water temperature) |
| Circulating Pump Pressure | 5.6 bar |
| Circulating Pump Flow Rate | 133 L/min |
| Reservoir Volume | 35 L |
| Duty Cycle | Continuous Operation |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Type | Split-System Circulating Chiller |
| Cooling Method | Water-Cooled |
| Temperature Range | –10 to 35 °C |
| Refrigeration Capacity | 2.4 kW (at 10 °C outlet water temperature) |
| Temperature Stability | ±0.5 °C |
| Circulation Pump Pressure | 5.5 bar |
| Circulation Flow Rate | 68 L/min |
| Reservoir Volume | 12 L |
| Operation Mode | Continuous |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Model | UC 24 |
| Cooling Type | Water-Cooled |
| Temperature Range | −10 to 35 °C |
| Temperature Stability | ±0.5 °C |
| Refrigeration Capacity | 24.3 kW @ 10 °C outlet |
| Circulating Pump Pressure | 5.8 bar |
| Flow Rate | 200 L/min |
| Reservoir Volume | 35 L |
| Duty Cycle | Continuous Operation |
| Enclosure Rating | IP54 |
| Configuration | Split System |
| Compliance | EU Ecodesign Directive (EU) 2016/2281, EN 60335-1, EN 60335-2-40 |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Model | UC 4 |
| Type | Split-System Circulating Chiller |
| Cooling Method | Water-Cooled |
| Temperature Range | –10 to 35 °C |
| Refrigeration Capacity | 4.8 kW (at 10 °C outlet water temperature) |
| Temperature Stability | ±0.5 °C |
| Circulating Pump Pressure | 5.5 bar |
| Circulating Pump Flow Rate | 68 L/min |
| Reservoir Volume | 12 L |
| Operation Mode | Continuous |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Model | UC 50 |
| Instrument Type | Split-System |
| Cooling Method | Water-Cooled |
| Temperature Control Range | –10 to 35 °C |
| Refrigeration Capacity | 51.2 kW (at 10 °C outlet water temperature) |
| Temperature Stability | ±0.5 °C |
| Circulation Pump Pressure | 6.5 bar |
| Circulation Flow Rate | 250 L/min |
| Reservoir Volume | 210 L |
| Operation Mode | Continuous |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Model | UC 65 |
| Cooling Type | Water-Cooled |
| Temperature Range | –10 to 35 °C |
| Temperature Stability | ±0.5 °C |
| Refrigeration Capacity | 66.9 kW (at 10 °C outlet water temperature) |
| Circulating Pump Pressure | 6.9 bar |
| Circulating Pump Flow Rate | 367 L/min |
| Reservoir Volume | 210 L |
| Operation Mode | Continuous |
| Configuration | Split-Type |
| Compliance | EU Ecodesign Directive (EU) 2016/2281, EN 60335-1, EN 60335-2-40 |
| Connectivity | LAUDA Cloud integration, remote monitoring via PC or IR remote control |
| Protection Rating | IP54 |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Model | UC 8 |
| Instrument Type | Split-System |
| Cooling Method | Water-Cooled |
| Temperature Range | –10 to 35 °C |
| Cooling Capacity | 10.2 kW (at 10 °C outlet water temperature) |
| Temperature Stability | ±0.5 °C |
| Circulation Pump Pressure | 5.6 bar |
| Circulation Flow Rate | 133 L/min |
| Reservoir Volume | 35 L |
| Operation Mode | Continuous |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Model | UC 80 |
| Cooling Type | Water-Cooled |
| Temperature Control Range | –10 to 35 °C |
| Temperature Stability | ±0.5 °C |
| Refrigeration Capacity | 80.0 kW (at 10 °C outlet water temperature) |
| Circulating Pump Pressure | 3.0 bar |
| Circulating Pump Flow Rate | 250 L/min |
| Reservoir Volume | 125 L |
| Operation Mode | Continuous |
| Configuration | Split-System |
| Compliance | EU Ecodesign Directive (EU) 2016/2281, EN 60335-1, EN 60335-2-40 |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Model | VC 2000W |
| Cooling Method | Water-Cooled |
| Temperature Range | –20 °C to +80 °C |
| Refrigeration Capacity | 2.00 kW (at +20 °C output) |
| Temperature Stability | ±0.05 K |
| Circulating Pump Pressure | 0.9 bar |
| Circulating Pump Flow Rate | 28 L/min |
| Reservoir Volume | 15 L |
| Operating Mode | Continuous |
| Refrigerant | R-449A (GWP 1397) |
| Dimensions (W×D×H) | 450 × 550 × 650 mm |
| Weight | 58 kg |
| Power Supply | 230 V, 14 A, 3.3 kW max |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Instrument Type | Integrated Circulating Chiller |
| Cooling Method | Water-Cooled |
| Temperature Range | −20 to 80 °C |
| Refrigeration Capacity | 1200 W at 20 °C |
| Temperature Stability | ±0.05 K (−20 to 40 °C) |
| Heating Power | 2.2 kW |
| Max. Pump Pressure | 0.9 bar |
| Pump Flow Rate | 28 L/min |
| Reservoir Volume | 15 L |
| Working Mode | Closed-Loop Cooling Water Circulation |
| Brand | The Great Wall |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Integrated Unit |
| Temperature Range | −80 °C to −40 °C |
| Cooling Capacity | 450 W (at −80 °C) / 1400 W (at −60 °C) / 2000 W (at −40 °C) |
| Temperature Stability | ±2 °C |
| Circulating Pump Pressure | 1 bar |
| Flow Rate | 30 L/min |
| Power Input | 4900 W |
| Supply Voltage | 3-phase, 380 V, 50 Hz |
| Refrigerants | R404A & R23 |
| Reservoir Volume | 10 L |
| Tank Material | SUS304 Stainless Steel |
| Dimensions (W×D×H) | 645 × 1060 × 1320 mm |
| Net Weight | 235 kg |
| Ambient Operating Conditions | 5–35 °C, ≤70% RH |
| Temperature Sensor | Pt100 |
| Display | Digital LED |
| Brand | The Great Wall |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | LT-100-80 |
| Instrument Type | Integrated Unit |
| Temperature Control Range | –80 °C to –40 °C |
| Cooling Capacity | 2500–10000 W |
| Temperature Stability | ±2 °C |
| Circulating Pump Pressure | 1 bar |
| Circulating Pump Flow Rate | 30 L/min |
| Brand | MICHEM |
|---|---|
| Origin | Beijing, China |
| Model | MC-10000C |
| Instrument Type | Split-System |
| Cooling Method | Water-Cooled |
| Temperature Control Range | 5–35 °C |
| Temperature Stability | ±0.1 °C |
| Refrigeration Capacity | 10,000 W |
| Circulating Pump Pressure | 7 bar |
| Circulating Pump Flow Rate | 6 L/min |
| Reservoir Volume | 100 L |
| Operating Mode | Continuous |
| Brand | MICHEM |
|---|---|
| Origin | Beijing, China |
| Model | MC-1000BP |
| Instrument Type | Integrated Circulating Chiller |
| Cooling Method | Water-Cooled |
| Temperature Range | 5–35 °C |
| Temperature Stability | ±0.1 °C |
| Refrigeration Capacity | 1000 W |
| Circulating Pump Pressure | 7 bar |
| Flow Rate | 6 L/min |
| Reservoir Volume | 10 L |
| Operating Mode | Continuous |
| Brand | MICHEM |
|---|---|
| Origin | Beijing, China |
| Model | MC-1000C |
| Instrument Type | Integrated Circulating Chiller |
| Cooling Method | Water-Cooled |
| Temperature Control Range | 5–35 °C |
| Cooling Capacity | 1000 W |
| Temperature Stability | ±0.1 °C |
| Circulation Pump Pressure | 7 bar |
| Circulation Flow Rate | 5 L/min |
| Reservoir Volume | 7 L |
| Operating Mode | Continuous |
| Compressor Type | Inverter-Driven |
| Control Algorithm | PID |
| Input Power | 500 W |
| Power Supply | 220 V, 10 A |
| Dimensions (W×D×H) | 520×420×680 mm |
| Brand | MICHEM |
|---|---|
| Model | MC-1000C |
| Type | On/Off-Controlled Recirculating Chiller |
| Cooling Capacity | 1000 W |
| Temperature Range | 5–35 °C |
| Temperature Stability | ±0.1 °C |
| Control Mode | PID with Auto-Tuning |
| Reservoir Volume | 7 L |
| Pump Flow Rate | 5 L/min |
| Max. Outlet Pressure | 5 bar |
| Power Input | 220 V, 10 A, 280 W |
| Dimensions (W×D×H) | 440 × 600 × 710 mm |
| Refrigeration Technology | Plate Heat Exchanger with Overcooling Protection |
| Temperature Sensor | Pt100 Platinum RTD with Line-Break & Voltage Fluctuation Compensation |
| Safety Features | Overvoltage Protection, Low-Temperature Cut-off (<3 °C), AL Alarm at <5 °C |
| Pump Type | Diaphragm Pump |
| Noise Level | Low-Noise Operation |
| Brand | MICHEM |
|---|---|
| Origin | Beijing, China |
| Model | MC-1600BP |
| Instrument Type | Integrated Circulating Chiller |
| Cooling Method | Water-Cooled |
| Temperature Range | 5–35 °C |
| Cooling Capacity | 1600 W |
| Temperature Stability | ±0.1 °C |
| Circulation Pump Pressure | 7 bar |
| Circulation Flow Rate | 6 L/min |
| Reservoir Volume | 10 L |
| Operating Mode | Continuous |
| Brand | MICHEM |
|---|---|
| Origin | Beijing, China |
| Model | MC-2500BP |
| Instrument Type | Integrated Circulating Chiller |
| Cooling Method | Water-Cooled |
| Temperature Control Range | 5–35 °C |
| Temperature Stability | ±0.1 °C |
| Refrigeration Capacity | 2500 W |
| Circulation Pump Pressure | 7 bar |
| Circulation Flow Rate | 6 L/min |
| Reservoir Volume | 10 L |
| Operating Mode | Continuous |
| Brand | MICHEM |
|---|---|
| Origin | Beijing, China |
| Model | MC-3500BP |
| Type | Split-System Circulating Chiller |
| Cooling Method | Water-Cooled |
| Temperature Range | 5–35 °C |
| Temperature Stability | ±0.1 °C |
| Refrigeration Capacity | 3500 W |
| Circulating Pump Pressure | 7 bar |
| Flow Rate | 6 L/min |
| Reservoir Volume | 20 L |
| Operation Mode | Continuous |
| Brand | MICHEM |
|---|---|
| Origin | Beijing, China |
| Model | MC-600C |
| Instrument Type | Integrated |
| Cooling Method | Water-Cooled |
| Temperature Range | 5–35 °C |
| Cooling Capacity | 600 W |
| Temperature Stability | ±0.1 °C |
| Circulation Pump Pressure | 7 bar |
| Circulation Flow Rate | 5 L/min |
| Reservoir Volume | 7 L |
| Operation Mode | Continuous |