Colorimeter
Filter
Showing 151–180 of 198 results
| Brand | Photo Research |
|---|---|
| Origin | USA |
| Model | PR-655 |
| Spectral Range | 380–780 nm |
| Detector Array | 128-element CCD |
| Spectral Resolution | 3.12 nm/pixel |
| Standard Aperture | 1° |
| Optional Apertures | 0.5° |
| Auto-Synchronization | Yes (to source refresh rate) |
| Data Storage | SD card |
| Interface | USB 2.0, Bluetooth (optional), RS-232 emulation via driver |
| Battery Life | Up to 12 hours (rechargeable Li-ion) |
| Display | 2.25" × 3" full-color touchscreen |
| Measurement Modes | Luminance, Illuminance, Radiance, Irradiance, Chromaticity (CIE x,y & u',v'), CCT, Duv, CRI (Ra, R1–R14), Dominant Wavelength, Purity, Spectral Power Distribution (SPD) |
| Remote Probe Support | Up to 15 filter-based probes (luminance, illuminance, or colorimetric) |
| Compliance | NIST-traceable calibration, ISO/IEC 17025-accredited calibration services available |
| Brand | Photo Research |
|---|---|
| Origin | USA |
| Model | PR-680L |
| Power Supply | Rechargeable Li-ion Battery |
| Display | 2.25" × 3" Full-Color Touchscreen |
| Detectors | 256-element CCD spectroradiometer + PMT photometer |
| Apertures | 1°, 0.5°, 0.25°, 0.125° (motorized) |
| Shutter | Motorized auto-shutter |
| Sync | AutoSync for flicker-free measurement |
| Interfaces | USB 2.0, Bluetooth (optional), RS-232 (via driver), Analog Output (optional) |
| Storage | SD card (up to 32 GB) |
| Operating Modes | Spectral Radiometry, PMT Photometry, Auto-Select Mode |
| Compliance | CIE 1931, CIE 1964, ISO/CIE 11664, ANSI C78.377, IEC 62368-1, FDA 21 CFR Part 11 (via SpectraWin software audit trail) |
| Brand | Photo Research |
|---|---|
| Origin | USA |
| Model | PR-730/735 |
| Detector Type | Cooled CCD (512 pixels) |
| Spectral Resolution | 0.781 nm/pixel |
| Minimum Luminance | 0.0003 cd/cm² |
| Spectral Bandwidth Options | 2 nm, 5 nm, 8 nm |
| Display | High-resolution full-color touchscreen |
| Communication Interfaces | USB, RS-232, Bluetooth (up to 100 m range) |
| Aperture Options | 8 interchangeable field-of-view apertures |
| Calibration Software | SpectraWin with user-accessible self-calibration module |
| Optical Compatibility | Fully compatible with PR LR-127 LED measurement accessory |
| Brand | Photo Research |
|---|---|
| Origin | USA |
| Model | PR-740/745 |
| Detector Type | Cooled 512-pixel CCD |
| Spectral Resolution | Up to 0.781 nm/pixel |
| Minimum Luminance | 0.000017 cd/cm² |
| Spectral Bandwidth Options | 2 nm, 5 nm, 8 nm |
| Display | High-Resolution Full-Color Touchscreen |
| Interface Options | USB, RS-232, Bluetooth (up to 100 m range) |
| Calibration | User-performed via SpectraWin Remote Mode & Built-in Self-Calibration Software |
| Optical Accessories | Eight interchangeable apertures |
| Compliance | ASTM E308, CIE 15:2018, ISO/CIE 11664, USP <1058> (analytical instrument qualification framework) |
| Brand | Photo Research |
|---|---|
| Origin | USA |
| Model | PR-920 |
| Detector | Scientific-grade thermoelectrically cooled 1024 × 1024 CCD array |
| Spectral Matching | CIE 1931 photopic (V(λ)) and colorimetric (x̄(λ), ȳ(λ), z̄(λ)) functions via precision interference filters |
| Measurement Parameters | Luminance (cd/m²), Chromaticity (CIE x,y |
| Spatial Resolution | Up to 1 megapixel full-frame acquisition |
| Optional Automation | Motorized 5-axis translation stage for programmable area scanning |
| Compliance | ASTM E308, CIE Publication No. 15, ISO/CIE 11664 series, USP <1058> (for instrument qualification in regulated environments) |
| Brand | Photo Research |
|---|---|
| Origin | USA |
| Model | PR-930 |
| Sensor Type | Interline-cooled CCD |
| Dynamic Range | 12-bit |
| Resolution | 8 MP (3,296 × 2,472) |
| Pixel Size | 5.5 × 5.5 µm |
| Minimum Measurable Spot | 27.5 × 27.5 µm (5×5 pixel binning) |
| FOV (@ 1 | 1 Macro Lens): 18.13 × 13.59 mm |
| Luminance Range | 0.005–500 cd/m² (ND-1 to ND-3 filters optional) |
| Luminance Accuracy (A-source) | ±2% (>0.05 cd/m²), ±3% (0.005–0.05 cd/m²) |
| Luminance Accuracy (Sample) | ±1% (>0.05 cd/m²), ±2% (0.005–0.05 cd/m²) |
| Luminance Repeatability (A-source) | ≥0.2% (>0.05 cd/m²), ≥1% (0.005–0.05 cd/m²) |
| Chromaticity Accuracy (A-source) | ±0.0015 CIE x,y (>0.05 cd/m²), ±0.005 CIE x,y (0.005–0.05 cd/m²) |
| Chromaticity Accuracy (Sample) | ±0.0015 CIE x,y (>0.05 cd/m²), ±0.005 CIE x,y (0.005–0.05 cd/m²) |
| Chromaticity Repeatability | ±0.001 CIE x,y (>0.05 cd/m²), ±0.003 CIE x,y (0.005–0.05 cd/m²) |
| Interface | USB 2.0 |
| Power Input | 100–240 VAC, 50–60 Hz |
| Power Consumption | 12 V, 3.8 A (45.6 W) |
| Operating Temperature | 5–30 °C, non-condensing |
| Weight | 3.77 kg |
| Brand | Radiant Vision Systems |
|---|---|
| Origin | USA |
| Model | PM-G |
| Sensor Resolution | 1536 × 1024 px (standard), 3072 × 2048 px (high-res option) |
| Dynamic Range | 14-bit (16,384 gray levels) |
| Luminance Range | 0.001 to 10¹⁰ nit (with ND filters) |
| Photometric Accuracy | Luminance (Y) ±3%, Illuminance ±3%, Chromaticity (x,y) ±0.003 |
| Short-Term Repeatability | Luminance <±0.5%, Chromaticity ±0.0006 |
| Lens Options | Motorized 35 mm, 50 mm, and 100 mm macro lenses with auto-focus and auto-iris |
| Measurement Speed (100 cd/m²) | Luminance-only: 2.3 s (G2/G3 mode) |
| Luminance + Chromaticity | 8 s (G2/G3 mode) |
| FOV | 40°×27° (35 mm), 30°×20° (50 mm), 15°×10° (100 mm macro) |
| Display | 125 mm diagonal LCD touchscreen (800×600) |
| Interface | USB 2.0/3.0, Gigabit Ethernet |
| Dimensions | 181 × 238 × 230 mm (H×W×D) |
| Weight | 4.9 kg |
| Operating Temperature | 0–30 °C |
| Operating Humidity | 20–70% RH (non-condensing) |
| Compliance | NIST-traceable calibration, ISO 11664, CIE S 014, ASTM E308, USP <1058> for analytical instrument qualification |
| Brand | Radiant Vision Systems |
|---|---|
| Origin | USA |
| Model | SIG-400 |
| Application | Near-field radiometric and photometric characterization of small light sources |
| Compatible Detector | ProMetric® imaging colorimeters and photometers |
| Output Format | Radiant Source Model™ (RSM), IES, EULUMDAT, ASAP, LightTools, TracePro, Zemax-compatible ray sets |
| Software Platform | ProSource® v5.0+ |
| Brand | Radiant ZEMAX |
|---|---|
| Origin | USA |
| Model | IS-LI |
| Type | Near-Field Imaging Measurement System for Angular Radiometric and Photometric Characterization |
| Application Scope | LED Light Sources, Flat Panel Displays (FPD), Diffusing Materials, Optical Films, Surface Scatter Analysis |
| Brand | Radiant Zemax |
|---|---|
| Origin | USA |
| Model | PM-1200 Series |
| Sensor Type | 12-bit CCD with CIE-matched optical filters |
| Measurement Capabilities | Luminance (cd/m²), Illuminance (lux), Radiance (W/sr·m²), Irradiance (W/m²), Luminous Intensity (cd), Radiant Intensity (W/sr) |
| Spatial Resolution | Up to 2.3 megapixels (configurable by model variant) |
| Dynamic Range | >1,000,000:1 (with electronic exposure control) |
| Compliance | ISO/CIE-compliant photometric and radiometric calibration traceable to NIST |
| Software Platform | ProMetric® v3.x or later (supports ASTM E308, CIE 15:2018, IEC 62368-1, and MIL-STD-3009 NVIS requirements) |
| Brand | Radiant Zemax |
|---|---|
| Origin | USA |
| Model | PM-1400F Series |
| Sensor Resolution | 768×512 / 1536×1024 / 3072×2048 pixels |
| ADC Dynamic Range | 14 bits (16,384 gray levels) |
| Luminance Range | 0.001 to 10¹⁰ nit (with ND filters) |
| Photometric Accuracy | Illuminance ±3%, Luminance (Y) ±3%, Chromaticity (x,y) ±0.003 |
| Short-Term Repeatability | Illuminance <±0.5%, Luminance <±0.5%, Chromaticity ±0.0006 |
| FOV Options | 1°–26° / 3°–50° / 5°–87° |
| Measurement Time (at 100 cd/m²) | 1.8–25 s depending on resolution |
| Interface | USB 2.0 |
| Dimensions | 154 × 242 × 200 mm |
| Weight | 4.8 kg |
| Operating Temperature | 0–30 °C |
| Operating Humidity | 20–70% RH (non-condensing) |
| Photometric Units | cd/m², cd/cm², fL, nit, mnit, W/sr/m², lux, fc, W/m², cd/sr, CIE (x,y), (u′,v′), CCT (K) |
| Brand | Radiant Zemax |
|---|---|
| Origin | USA |
| Model | PM-1600F Series |
| Detector Type | TE-Cooled Scientific CCD |
| Resolution | 512 × 512 or 1024 × 1024 pixels |
| Dynamic Range | 16-bit (65,536 gray levels) |
| Minimum Luminance | 0.0005 cd/m² |
| Maximum Luminance (with ND filters) | 10¹⁰ cd/m² |
| Photometric Accuracy | ±3% for luminance (Y) and illuminance |
| Chromaticity Accuracy | ±0.003 in CIE x,y |
| Short-Term Repeatability | <±0.5% for luminance, ±0.0006 in CIE x,y |
| Measurement Time (at 100 cd/m²) | 2–9 sec depending on resolution and binning |
| FOV Range | 2°–38° (512×512), 5°–80° (1024×1024) |
| Interface | USB 2.0 |
| Dimensions | 154 mm (H) × 242 mm (W) × 200 mm (D) |
| Weight | 4.8 kg |
| Operating Temperature | 0–30 °C |
| Operating Humidity | 20–70% RH (non-condensing) |
| Software | ProMetric® v5.x or later |
| Compliance | ASTM E308, ISO/CIE 11664, CIE 15:2018, USP <1058>, FDA 21 CFR Part 11 (audit trail & electronic signature support) |
| Brand | Radiant Zemmax |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | PM-I |
| Pricing | Available Upon Request |
| CCD Resolution | 3296 × 2472 px (Standard), 4896 × 3264 px (High-Resolution Option) |
| Dynamic Range | 12-bit (4096 grayscale levels) |
| Luminance Range | 0.01 to 10¹⁰ nit (with ND filters) |
| Photometric Accuracy | Illuminance ±3%, Luminance (Y) ±3%, Chromaticity (x,y) ±0.003 |
| Short-Term Repeatability | Illuminance <±0.5%, Luminance <±0.5%, Chromaticity ±0.0006 |
| Measurement Speed (100 cd/m²) | Luminance-only: 0.7 s |
| Luminance + Chromaticity | 3.7 s |
| Lens Options | 20 mm, 35 mm, 50 mm, 100 mm macro |
| Focus & Aperture | Motorized |
| Display | 125 mm diagonal LCD touchscreen (800 × 600) |
| Interface | USB 2.0/3.0, Gigabit Ethernet |
| Dimensions | 181 × 238 × 230 mm (H × W × D) |
| Weight | 4.9 kg |
| Operating Temperature | 0–30 °C |
| Operating Humidity | 20–70% RH (non-condensing) |
| Brand | Radiant Zemax |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SIG-300 |
| Pricing | Upon Request |
| CCD Type | Full-frame, thermoelectrically cooled CCD |
| CCD Dynamic Range | 16-bit (65,536:1) |
| Resolution Options | 512 × 512 or 1024 × 1024 pixels |
| FOV (Standard) | 2 mm, 4 mm, 8 mm (512×512) |
| FOV (Micro Extension) | 0.5 mm, 1.2 mm |
| FOV (Large Extension) | 40 mm, 80 mm |
| Color Filter Set | CIE 1931 XYZ tristimulus filters |
| Neutral Density Filters | ND0 to ND5 |
| Polar Rotation Range | −10° to +370° |
| Azimuthal Tilt Limit | ±24° from lamp axis |
| Angular Step Resolution | 0.10°/min |
| Mechanical-Optical-Software Runout | < 0.025 mm |
| System Dimensions | 120 cm × 77 cm × 177 cm |
| Minimum Operating Footprint | 120 cm × 120 cm |
| Mass | 360 kg |
| Structural Frame | Welded steel cast housing with thermal stability design |
| Software Platform | SIG 2.0 — supports luminance, illuminance, chromaticity (CIE x,y |
| Brand | Radiant Zemax |
|---|---|
| Origin | USA |
| Model | SIG-310 |
| CCD Type | Full-frame, thermoelectrically cooled CCD |
| Dynamic Range | 16-bit (65,536:1) |
| Resolution Options | 512 × 512 or 1024 × 1024 pixels |
| FOV (Standard) | 6–160 mm (512×512) |
| FOV (Macro) | 300 mm (512×512 only) |
| Color Filters | CIE 1931 XYZ tristimulus with ND filters (ND0–ND5) |
| Polar Rotation | −10° to +370° |
| Azimuthal Tilt | ±20° from lamp axis |
| Angular Step Resolution | 0.10°/min |
| Mechanical-Optical-Software Runout | ≤0.100 mm |
| System Dimensions | 145 cm × 133 cm × 204 cm |
| Operating Footprint | 343 cm × 312 cm |
| Weight | 640 kg |
| Structural Frame | Welded steel cast body with thermal-stability design |
| Software | SIG 2.0 — supports luminance, illuminance, chromaticity (CIE x,y |
| Brand | Radiant Zemax |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SIG-400 |
| Pricing | Upon Request |
| Brand | Radiant Zemax |
|---|---|
| Origin | USA |
| Model | VisionCAL |
| Type | Imaging Colorimeter-Based Display Calibration System |
| Application | Pixel-Level Luminance & Chromaticity Calibration of LED Displays |
| Compliance | Designed for ISO 11664, CIE S 014-2/E:2022, and ASTM E308-23 workflows |
| Software Architecture | Windows-based, FDA 21 CFR Part 11–ready audit trail support (optional), GLP/GMP-compatible data logging |
| Brand | Radiant Zemax |
|---|---|
| Origin | USA |
| Model | ZEMAX 13 |
| Type | Optical Design & Illumination Simulation Software |
| Compliance | ASTM E284, ISO/CIE 11664 (Colorimetry), USP <1059>, FDA 21 CFR Part 11 (via optional audit trail module) |
| CAD Integration | Native bidirectional sync with SolidWorks®, Autodesk Inventor®, Creo Parametric® |
| File Formats | STEP, SAT, IGES, STL, IES, LDT, ZMX, FRED, ASAP, LightTools® import/export |
| Programming Interface | ZPL (Zemax Programming Language), MATLAB® interoperability, COM/ActiveX, .NET API, user-defined DLL support |
| Optical Engine | Hybrid sequential/non-sequential ray tracing engine with physical optics propagation (Gaussian, Laguerre-Gaussian, TEM modes), BSDF material modeling, GRIN media, polarization & thin-film stack analysis |
| License Type | Perpetual or subscription-based floating/network license |
| Brand | SCHMIDT + HAENSCH |
|---|---|
| Origin | Germany |
| Model | Coloromat 100 |
| Optical Principle | Single-beam spectrophotometry |
| Spectral Range | 420–900 nm |
| Fixed Wavelengths | 340, 420, 720 nm |
| Customizable Wavelengths | up to 6 additional (340–900 nm), total ≤9 |
| Extinction Accuracy | ±0.020 (340 & 420 nm), ±0.010 (720 nm), ±0.020 (other wavelengths) |
| ICUMSA Range | 0–16.000 IU |
| ICUMSA Accuracy | ±10% (<20 IU), ±5% (>20 IU) |
| Extinction Resolution | 0.001 |
| Light Source | 12 V / 20 W halogen lamp |
| Display | Graphical touchscreen interface |
| Interface | RS232C |
| Operating Temperature | 10–40 °C |
| Power Supply | 85–265 V AC, 47–63 Hz |
| Language Support | English & German (others on request) |
| Internal Method Storage | 250 pre-programmed methods (ROM), up to 230 user-defined methods (RAM) |
| Data Storage Capacity | 2970 measurements, 99 sample IDs |
| Compliance | GLP/GMP-compliant data handling, audit-trail-ready operation |
| Brand | Schmidt + Haensch |
|---|---|
| Origin | Germany |
| Model | Saccharoflex 2020 |
| Measurement Principle | Reflectance Photometry |
| Wavelengths | 495 nm and 620 nm |
| ICUMSA Method Compliance | GS2-11 (1994) and GS2-13 (1994) |
| Range | 0–19.99 ICUMSA Color Units (CU) |
| Resolution | 0.01 CU |
| Accuracy | ±0.15 CU |
| Repeatability | ±0.15 CU |
| Light Source | 12 V / 20 W Halogen Lamp |
| Display | Backlit LCD |
| Interface | RS-232C and USB-B |
| Operating Temperature | 10–40 °C |
| Power Supply | 100–240 V AC, 50–60 Hz |
| Language Support | English and German |
| Calibration Standards | Brunswick ceramic reference tiles (CU 0 and CU 6 recommended) |
| Brand | Schmidt+Haensch (S+H) |
|---|---|
| Country of Origin | Germany |
| Model | Coloromat-S |
| Wavelength Range | 340–900 nm |
| Standard Filters | 340 nm, 420 nm, 720 nm |
| Optional Wavelengths | Up to 9 user-selectable wavelengths |
| Wavelength Calibration | Automatic |
| Light Source | 12 V / 20 W halogen lamp |
| Detector | Silicon photodiode |
| Display | Graphical color touchscreen interface |
| Sample Cell Pathlength | Up to 100 mm (flow-through or static cuvette) |
| Measurement Modes | Transmittance, absorbance, extinction, and CIE-based color values (e.g., CIELab, EBC, ICUMSA) |
| Compliance | GLP/GMP-ready with audit trail support (user login, method storage, data timestamping) |
| Brand | Schmidt+Haenscher |
|---|---|
| Origin | Germany |
| Model | Saccharoflex 2000 |
| Measurement Range | 0–19.99 CTU |
| Resolution | 0.01 CTU (low range), 0.05 CTU (high range) |
| Optical Wavelengths | 495 nm and 620 nm |
| Display | 30-character LCD |
| Interface | 4-button membrane keypad |
| Compliance | ICUMSA Method GS2/3-13 (2013) for sucrose color determination |
| Sample Form | Solid, granular, or powdered materials (e.g., crystalline sugar, ceramic powders, cement clinker) |
| Calibration Standards | Certified CTU reference standards (0 CTU and 6 CTU, sugar- or ceramic-matrix matched) |
| Brand | Shenchanghong |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic (China) |
| Model | LCLR-50 |
| Price | USD 420 (est.) |
| Measurement Range | 0.00–100 PCU |
| Resolution | 0.01 PCU |
| Basic Error | ±3% F.S. |
| Repeatability | ≤3% |
| Optical Stability | Absorbance drift <0.002 A within 20 min |
| Dimensions (H×W×D) | 266 mm × 200 mm × 130 mm |
| Weight | 1.0 kg |
| Operating Temperature | 5–40 °C |
| Relative Humidity | ≤85% RH |
| Power Supply | AC (220 ± 22) V, (50 ± 0.5) Hz |
| Light Source Lifetime | 100,000 hours |
| Filter System | Narrow-band optical interference filters |
| Compliance | GB/T 5750.4–2006 (Platinum-Cobalt Colorimetric Method) |
| Brand | Shenchanghong |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | LCLR-50A |
| Pricing | Upon Request |
| Measurement Range | 0.00–500 PCU |
| Resolution | 0.01 PCU |
| Basic Accuracy | ±3% of Full Scale |
| Repeatability | ≤3% |
| Optical Stability | Absorbance drift <0.002 A within 20 min |
| Dimensions (H×W×D) | 266 mm × 200 mm × 130 mm |
| Weight | 1 kg |
| Operating Temperature | 5–40 °C |
| Relative Humidity | ≤85% RH |
| Power Supply | AC (220 ± 22) V, (50 ± 0.5) Hz |
| Light Source Lifetime | 100,000 hours |
| Filter System | Narrow-band optical interference filters |
| Compliance | GB/T 5750.4–2006 (Platinum-Cobalt Colorimetric Method) |
| Brand | Shenchanghong |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | PCLR-20A |
| Price | USD 495 (FOB Guangdong) |
| Measurement Range | 5–500 PCU |
| Accuracy | ≤ ±3% FS |
| Repeatability | ≤ ±2% FS |
| Resolution | 0.1 PCU |
| Drift | < 0.002 A/h |
| Light Source | High-stability narrow-band cold LED |
| Optical System | Fixed-wavelength interference filter with 5 cm pathlength cuvettes |
| Power Supply | Rechargeable lithium-ion battery (6-month standby) |
| Weight | 1.0 kg |
| Dimensions | 80 × 230 × 55 mm |
| IP Rating | IP65 |
| Data Storage | 20 calibration curves + 199 measurement records |
| Interface | USB 2.0 |
| Display | Backlit Chinese LCD |
| Compliance | Designed per ISO 7887:2011 (Water quality — Examination of colour) principles |
| Brand | Shenchanghong |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | TCLR-50 |
| Price | Upon Request |
| Measurement Range | 5–100 PCU |
| Accuracy | ≤ ±3% FS |
| Repeatability | ≤ ±2% FS |
| Resolution | 0.01 PCU |
| Drift | < 0.1 PCU/h |
| Weight | 1 kg |
| Dimensions | 266 × 200 × 130 mm |
| Operating Temperature | 5–40 °C |
| Relative Humidity | ≤70% RH |
| Power Supply | AC (220 ±10%) V, 50 Hz |
| Display | Backlit LCD with Chinese UI |
| Data Storage | 10 calibration curves + 199 measurement records |
| Light Source | High-brightness, long-life (100,000 h) imported LED |
| Optical System | Narrow-band interference filter-based photometric detection |
| Housing Material | Corrosion-resistant ABS |
| Microcontroller | Low-power 16-bit MCU |
| Brand | Shenchanghong |
|---|---|
| Model | TCLR-50A |
| Measurement Range | 0.00–500 PCU |
| Resolution | 0.01 PCU |
| Accuracy | ±3% of full scale |
| Repeatability | ≤3% |
| Optical Drift | <0.002 A within 20 min |
| Dimensions | 340 × 250 × 130 mm |
| Weight | 4 kg |
| Operating Temperature | 5–40 °C |
| Relative Humidity | ≤85% |
| Power Supply | AC (220 ± 22) V, (50 ± 0.5) Hz |
| Light Source | High-brightness, long-life (100,000 h) imported LED |
| Display | Large LCD with Chinese interface |
| Data Storage | 10 calibration curves + 500 measurement records |
| Connectivity | USB port for data export |
| Optional | Thermal printer support |
| Brand | Shengaohua |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | 6B-50S (V9) |
| Measurement Range | 0–1000 degrees Pt-Co |
| Detection Limit | 0.001 degree Pt-Co |
| Accuracy | ±5% FS |
| Repeatability | ±3% RSD |
| Zero Drift | <0.001 AU |
| Light Source | Long-life Cold LED |
| Display | Backlit LCD with Touch Keypad |
| Data Storage | 8 GB Internal MicroSD Card |
| Power Supply | Integrated Rechargeable Battery |
| Compliance | GB/T 5750.4–2023 (Platinum-Cobalt Colorimetric Method) |
| Brand | SETA |
|---|---|
| Origin | United Kingdom |
| Model | AF650 |
| Measurement Range | 0.5–8.0 ASTM |
| Light Source | 12 V / 20 W Halogen Tungsten Lamp (CIE Illuminant C) |
| Cell Path Length | 33 mm |
| Standard Disc Sets | Disc 1 (0.5, 1.5, 2.5, 3.5, 4.5, 5.5, 6.5, 7.5), Disc 2 (1.0, 2.0, 3.0, 4.0, 5.0, 6.0, 7.0, 8.0) |
| Compliance | ASTM D1500, ISO 2049, IP 196, DIN 51578, BS 5859, JIS K2580, NF T60-104, NBN T52-109, FTM 719-102 |
| Certification | CE |
| Power Supply | 220 V AC input with 12 V DC adapter |
| Dimensions | 235 × 245 × 90 mm |
| Weight | 4.9 kg |
| Brand | Tintometer (Lovibond®) |
|---|---|
| Origin | United Kingdom |
| Model | Lovibond® Comparator 3000 |
| Light Source | CIE-compliant halogen tungsten lamp |
| Viewing Configuration | Tristimulus field (sample + two adjacent glass color standards) |
| Compliance | ASTM D1500, EBC Method 6.1, AOAC 920.147, ISO 4630, USP <631>, Gardner, FAC, US Military Resin Standards |
| Accessories | Industry-specific calibrated glass color discs (non-fading), optional NIST-traceable filter sets and certified reference standards |
| Application Scope | Petrochemicals, edible oils, resins, beverages, pharmaceutical excipients, industrial chemicals |