| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Model | H 4 |
| Temperature Range | 25–100 °C |
| Temperature Stability | ±0.1 °C |
| Bath Volume | 3.5 L |
| Heating Power | 0.5 kW |
| Dimensions (W×D×H) | 340×290×275 mm |
| Bath Opening (W×L) | 100×245 mm |
| Usable Depth | 115 mm |
| Weight | 7 kg |
| Power Supply | 230 V, 50/60 Hz |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Model | H 41 |
| Temperature Range | 25–100 °C |
| Temperature Stability | ±0.1 °C |
| Bath Volume | 37.9 L |
| Heating Power | 1.5 kW |
| Dimensions (W×D×H) | 510×490×476 mm |
| Bath Opening (W×L) | 410×296 mm |
| Usable Depth | 285 mm |
| Weight | 22 kg |
| Power Supply | 230 V, 50/60 Hz |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Model | H 5 V |
| Temperature Range | 25–100 °C |
| Temperature Stability | ±3 °C |
| Bath Volume | 5.0 L |
| Heating Power | 1.0 kW |
| Dimensions (W×D×H) | 342×400×180 mm |
| Bath Diameter | 192 mm |
| Weight | 9 kg |
| Voltage/Frequency | 230 V, 50/60 Hz |
| Protection | Low-Level Cut-Off |
| Construction | Stainless Steel Bath, Heat-Resistant Plastic Lid Rings |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Model | H 6 V |
| Operating Temperature Range | 25–100 °C |
| Temperature Stability | ±3 °C |
| Bath Volume | 5.3 L |
| Heating Power | 1.0 kW |
| Dimensions (W×D×H) | 1010 × 270 × 192 mm |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Model | H 8 A |
| Temperature Range | 25–100 °C |
| Temperature Stability | ±0.1 °C |
| Bath Volume | 7.0 L |
| Heating Power | 1.0 kW |
| Dimensions (W×D×H) | 340×395×345 mm |
| Stirring | Integrated Magnetic Drive |
| Bath Opening | 245×200 mm |
| Usable Depth | 115 mm |
| Weight | 12 kg |
| Power Supply | 230 V, 50/60 Hz |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Model | H 8 |
| Temperature Range | 25–100 °C |
| Temperature Stability | ±0.1 °C |
| Bath Volume | 7.0 L |
| Heating Power | 1.0 kW |
| Dimensions (W×D×H) | 340×395×275 mm |
| Bath Opening (W×L) | 200×245 mm |
| Usable Depth | 115 mm |
| Weight | 10 kg |
| Power Supply | 230 V, 50/60 Hz |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Model | H 9 V |
| Temperature Range | 25–100 °C |
| Temperature Stability | ±3 °C |
| Bath Volume | 8.0 L |
| Heating Power | 1.5 kW |
| Dimensions (W×D×H) | 1010×270×192 mm |
| Bath Opening Diameter | 131 mm |
| Bath Usable Depth | 90 mm |
| Number of Bath Openings | 6 |
| Weight | 19 kg |
| Power Supply | 230 V, 50/60 Hz |
| Material | Stainless Steel (bath interior, bottom sieve plate, cover, heating element), Heat-Resistant Polymer (adjustable ring inserts) |
| Safety Features | Low-Level Fluid Detection, Auto-Shutoff |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Model | H2P |
| Temperature Range | 25–80 °C |
| Temperature Stability | ±0.5 °C |
| Bath Volume | 1.6 L |
| Heating Power | 0.3 kW |
| Dimensions (W×D×H) | 280×280×100 mm |
| Bath Chamber Diameter × Depth | 200×50 mm |
| Supply Voltage | 230 V, 50/60 Hz |
| Protection | Dry-run safety cutoff |
| Material | Black anodized aluminum bath chamber and wide heated rim |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Model | H5V |
| Bath Volume | 37.9 L |
| Temperature Range | 25–100 °C |
| Temperature Stability | ±0.1 K |
| Heating Power | 1.05 kW |
| Circulation | Internal & External |
| Control Type | Heating-Only |
| Bath Opening Dimensions | 342 × 400 mm |
| External Dimensions (W×D×H) | 342 × 400 × 180 mm |
| Construction Material | Stainless Steel (AISI 304) |
| Display | TFT, Dual-Scale (°C/°F) |
| Compliance | CE, RoHS, ISO 9001-certified Manufacturing |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Model | Integral 280 XTW |
| Cooling Method | Water-cooled |
| Temperature Range | –80 to +220 °C |
| Cooling Capacity | 9000 W |
| Temperature Stability | ±0.05 K |
| Circulation Pump Pressure | 3.1 bar |
| Circulation Flow Rate | 65 L/min |
| Reservoir Volume | 4.8–17.2 L |
| Operation Mode | Continuous |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Model | IN 2050 PW |
| Instrument Type | Integrated Circulating Chiller |
| Cooling Method | Water-Cooled |
| Temperature Range | –40 to +140 °C |
| Refrigeration Capacity | 15,000 W |
| Temperature Stability | ±0.05 °C |
| Pump Pressure | 6.0 bar |
| Pump Flow Rate | 120 L/min |
| Reservoir Volume | 11.1–36.3 L |
| Operating Mode | Continuous |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Model | IN2050 PW |
| Temperature Range | −40 to +140 °C |
| Bath Volume | 36.3 L |
| Circulation Type | Internal & External |
| Temperature Control Mode | Refrigeration & Heating |
| Fluid Compatibility | Water/glycol mix (non-flammable, pressurized up to 4 bar) |
| Pump | High-performance LAUDA variable-speed pressure pump (8 output levels, pressure regulation) |
| Programmability | 150-step temperature/time program (5 independent programs) |
| Display | TFT touchscreen with multi-interface switching (curve view, parameter view) |
| Connectivity | Built-in web server (LAN access via PC/tablet/smartphone), Ethernet & USB ports included |
| Accessories Included | Pt100 sensor, fault contactor, vacuum-fill nozzle tube |
| Expansion | Two modular expansion slots |
| Dimensions (W×D×H) | 1100 × 895 × 1865 mm |
| Heating Power | 16 kW |
| Cooling Power (at 20 °C) | 20 kW |
| Max Flow Rate / Pump Pressure | 120 L/min / 6.0 bar |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Model | Integral P |
| Temperature Range | -40 to +140 °C |
| Heat Transfer Fluid | Non-flammable water/ethylene glycol mixture |
| Max Operating Pressure | 4 bar (gauge) |
| Pump Type | Magnetically coupled, electronically controlled |
| Flow Rate | Adjustable per application |
| Compatible Controller | LAUDA MID 80 Flow Control Unit |
| Application Focus | Automotive, Aerospace, EV Battery Thermal Testing |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Model | IN 230 TW |
| Instrument Type | Integrated Circulating Chiller |
| Cooling Method | Water-Cooled |
| Temperature Range | –30 to 120 °C |
| Refrigeration Capacity | 2300 W |
| Temperature Stability | ±0.05 °C |
| Pump Pressure | 3.5 bar |
| Pump Flow Rate | 40 L/min |
| Reservoir Volume | 3.6–8.7 L |
| Operating Mode | Continuous |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Model | IN230T |
| Bath Volume | 25.5 L |
| Temperature Range | −30 to +150 °C |
| Temperature Stability | ±0.1 K |
| Circulation Type | Internal & External |
| Cooling/Heating Mode | Dual-function |
| Pump Type | Immersed High-Flow Pump with Overflow Connection |
| Controller | Rotatable Touchscreen Interface with Dedicated Keypad |
| Network Capability | Built-in Web Server (LAN Access via PC/Tablet/Smartphone) |
| Optional Extended Power | Up to 16 kW Heating / 13 kW Cooling |
| Bypass Valve | Integrated Pressure-Limiting Bypass with Standard Configuration |
| Fill/Drain Ports | Side-Mounted for Operational Convenience |
| Compliance | Designed for GLP/GMP-aligned process development environments |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Model | T1200 |
| Temperature Range | −25 °C to +120 °C |
| Temperature Stability | ±0.2 °C |
| Heating Power | 2.25 kW |
| Cooling Capacity at 20 °C | 1.2 kW |
| Pump Flow Rate | 40 L/min |
| Maximum Pump Pressure | 3.2 bar |
| Bath Volume | 7 L |
| Dimensions (W×D×H) | 450 × 550 × 790 mm |
| Cooling Type | Air-Cooled |
| Circulation Mode | Internal & External Dual Loop |
| Control System | Microprocessor-Based with Programmable Ramp-Soak Profiles (5 Programs, 150 Segments) |
| Display | Dual-Line LCD (Setpoint & Actual Temperature) |
| External Sensor Input | Pt100 Compatible for Remote Temperature Control |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Integral XT 950 W |
| Pricing | Upon Request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | XT 250 W |
| Pricing | Upon Request |
| Temperature Range | –45 to +200 °C |
| Temperature Stability at –10 °C | ±0.05 K |
| Heating Power | 3.5 kW |
| Cooling Capacity at 20 °C | 2.1 kW |
| Max. Pump Pressure | 2.9 bar |
| Max. Pump Flow Rate | 45 L/min |
| Minimum Fill Volume | 2.6 L |
| Expansion Tank Fill Volume | 5.5 L |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Model | IN 150 XT |
| Cooling Method | Air-Cooled |
| Temperature Range | -45 to 220 °C |
| Cooling Capacity | 1.5 kW (at 20 °C, Pump Level 8) |
| Temperature Stability | ±0.05 °C |
| Pump Pressure | 3.1 bar |
| Pump Flow Rate | 65 L/min |
| Reservoir Volume | 2.5–8.7 L |
| Operating Mode | Continuous |
| Heater Power | 3.5 kW |
| Max. Power Consumption | 3.7 kW |
| Noise Level | 60 dB(A) |
| Net Weight | 103 kg |
| Dimensions (W×D×H) | 430 × 550 × 760 mm |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Model | IN 1590 XTW |
| Cooling Method | Water-Cooled |
| Temperature Range | −90 °C to 220 °C |
| Refrigeration Capacity | 18.5 kW |
| Temperature Stability | ±0.05 °C |
| Circulation Pump Pressure | 3.1 bar |
| Circulation Flow Rate | 65 L/min |
| Bath Volume | 30.6 L |
| Operating Mode | Continuous |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Model | IN 1850 XTW |
| Cooling Method | Water-Cooled |
| Temperature Range | –50 °C to +220 °C |
| Refrigeration Capacity | 20,000 W |
| Temperature Stability | ±0.05 °C |
| Circulating Pump Pressure | 6.0 bar |
| Circulating Pump Flow Rate | 120 L/min |
| Bath Volume | 8.0–28.6 L |
| Operation Mode | Continuous |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Model | IN 550XTW |
| Cooling Method | Water-Cooled |
| Temperature Range | −50 °C to 220 °C |
| Cooling Capacity | 5800 W |
| Temperature Stability | ±0.05 °C |
| Pump Pressure | 3.1 bar |
| Pump Flow Rate | 65 L/min |
| Reservoir Volume | 4.8–17.2 L |
| Operation Mode | Continuous |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Model | IN 950 XTW |
| Cooling Method | Water-Cooled |
| Temperature Range | -50 °C to 220 °C |
| Refrigeration Capacity | 9500 W |
| Temperature Stability | ±0.05 °C |
| Circulation Pump Pressure | 3.1 bar |
| Circulation Flow Rate | 65 L/min |
| Reservoir Volume | 4.8–17.2 L |
| Operation Mode | Continuous |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Model | Integral XT |
| Type | Circulating Bath Chiller/Heater |
| Temperature Range | −50 °C to +300 °C |
| Temperature Stability | ±0.05 °C (typical) |
| Heating Power | up to 10.4 kW |
| Cooling Capacity at 20 °C | up to 18.5 kW |
| Pump Flow Rate | up to 90 L/min |
| Max. Pump Pressure | 5.8 bar |
| Reservoir Volume | 5.5–17.4 L |
| Cooling Method | Air-cooled or Water-cooled |
| Control Interface | Graphical LCD with detachable remote controller |
| Communication | RS-232/RS-485 standard, optional Ethernet/Modbus/Profibus modules |
| Compliance | CE, UL, ATEX optional |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Model | KHS3560W |
| Instrument Type | Circulating Bath Chiller/Heater |
| Circulation Mode | Internal Recirculation |
| Temperature Control | Dual-mode (Heating & Refrigeration) |
| Bath Volume | 55 L |
| Temperature Range | –60 °C to 200 °C |
| Temperature Stability | ±0.5 K |
| Heating Power | 18.0 kW |
| Refrigeration Power at 20 °C | 35.0 kW |
| Max Flow Rate / Pump Pressure | 85 L/min / 5.5 bar |
| Minimum Fill Volume | 15 L |
| Dimensions (W×D×H) | 920 × 1200 × 1700 mm |
| Pump Type | Magnetically Coupled, Speed-Adjustable |
| Refrigeration System | Two-Stage Compression |
| Cooling Method | Water-Cooled Condenser |
| Expansion Valve | Stepper-Motor Controlled |
| Standard Interfaces | USB, LEMO for External Sensor Input |
| Communication | Configurable Analog/Digital Modules (e.g., 4–20 mA, Modbus RTU, Profibus DP) |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Model | KHS 3560 W / KHS 2190 W |
| Temperature Range | –90 °C to +200 °C |
| Refrigeration System | Dual-stage compressor (down to –60 °C) or cascade refrigeration (down to –90 °C) |
| Cooling Method | External water-cooled condenser |
| Expansion Control | Stepper-motor-driven electronic expansion valve |
| Pressure Rating | Designed for pressurized operation with nitrogen (up to 6 bar typical, per system configuration) |
| Application Environment | Industrial process simulation, pharmaceutical synthesis, chemical R&D, automotive & aerospace environmental testing |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Model | LOOP 100 |
| Instrument Type | Integrated Circulating Chiller |
| Cooling Method | Air-Cooled |
| Temperature Range | 4–80 °C |
| Refrigeration Capacity | 60 W (at 10 °C output) |
| Temperature Stability | ±0.1 °C |
| Circulation Pump Pressure | 0.8 bar |
| Circulation Flow Rate | 2.6 L/min |
| Bath Volume | 0.28 L |
| Operating Mode | Continuous |
| Display | High-Contrast OLED Graphic Screen |
| Interface | RS232 |
| Power Supply | 100–240 V, 50/60 Hz |
| Max. Power Consumption | 0.24 kW |
| Dimensions (W×D×H) | 175 × 301 × 266 mm |
| Net Weight | 6.5 kg |
| Noise Level | 57 dB(A) |
| Fluid Compatibility | Water, Water/Ethylene Glycol Mixtures (Non-Flammable Only) |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Model | LOOP 250 |
| Instrument Type | Integrated Circulating Chiller |
| Cooling Method | Air-Cooled |
| Temperature Range | 4–80 °C |
| Refrigeration Capacity | 130 W (at 10 °C output) |
| Temperature Stability | ±0.1 °C |
| Circulation Pump Pressure | 0.8 bar |
| Circulation Flow Rate | 2.6 L/min |
| Bath Volume | 0.32 L |
| Operating Mode | Continuous |
| Heating Power | 400 W |
| Pump Max Flow (at zero head) | 3 L/min |
| Dimensions (W×D×H) | 261 × 368 × 312 mm |
| Weight | 12 kg |
| Noise Level | 57 dB(A) |
| Power Supply | 100–240 V, 50/60 Hz |
| Protection Class | IP20 |
| Fluid Compatibility | Water, Water/Glycol Mixtures (non-flammable) |
| Interface | RS232 |
| Display | High-contrast OLED Graphical Screen |
| Control Interface | 3-button intuitive navigation |
| Connection | Quick-release 1/4″ C-type fittings |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Model | LOOP |
| Temperature Range | 4–80 °C |
| Cooling Power | 120 W (L 100), 250 W (L 250) |
| Input Voltage | 100–240 V AC, 50/60 Hz |
| Cooling Method | Refrigerant-free air-cooled system |
| Fluid Compatibility | Non-flammable liquids (e.g., water, water/ethylene glycol mixtures) |
| Display | High-contrast graphical OLED |
| Interface | RS232 |
| User Interface | 3-key soft-touch control |
| Pump Connection | Quick-release fittings |
| Noise Level | Low (typ. <45 dB(A) at partial load) |
| Compliance | CE, RoHS, IEC 61010-1 |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Model | LOOP L100 |
| Instrument Type | Integrated Circulating Chiller |
| Cooling Method | Air-Cooled |
| Temperature Range | 4–80 °C |
| Temperature Stability | ±0.1 K |
| Refrigeration Capacity (at 20 °C) | 0.12 kW |
| Circulating Pump Pressure | 0.8 bar |
| Flow Rate | 3 L/min |
| Bath Volume | 0.28 L |
| Power Supply | 100–240 V AC, 50/60 Hz |
| Operating Mode | Plug-and-Play |
| Refrigerant-Free Operation | Yes |
| Compatible Heat Transfer Fluids | Water, Water-Glycol Mixtures (Non-Flammable) |
| Dimensions (W×D×H) | 175 × 301 × 266 mm |
| Weight | ~6.2 kg |