| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | CCS-XG-UHV |
| Price | Upon Request |
| Cooling Type | Closed-Cycle Refrigeration |
| Temperature Range | <4 K to 325 K |
| Typical Temperature Stability | ±50 mK |
| Sample Environment | Ultra-High Vacuum (UHV) |
| Bake-Out Temperature (Cold Head Removed) | 200 °C |
| Cool-Down Time | 2–3 h |
| Vibration Level | <40 nm (RMS) |
| Cold Head Position | Top-Mounted |
| Optical Window | Not Standard |
| Approximate Height | 559–660 mm |
| Weight | Configuration-Dependent |
| Recommended Cold Head Maintenance Interval | 10,000 h |
| Key | Brand: Lake Shore |
|---|---|
| Origin | USA |
| Model | FP Series Hall Probe |
| Field Range | Earth’s magnetic field to 35 T |
| Sensor Active Area | 0.1 mm² |
| Frequency Response | DC to 50 kHz |
| Output Type | Analog voltage (ratiometric or compensated) |
| Compensation | Built-in temperature and magnetic linearity compensation |
| Probe Form Factor | Handheld and mountable configurations |
| Axis Sensitivity | Axial, transverse, and triaxial options available |
| Calibration | NIST-traceable, factory-calibrated |
| Compliance | Designed for ASTM E1447, ISO/IEC 17025-compliant labs, compatible with Lake Shore F71/F41 Teslameters and 475/455/425 Gaussmeters |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | Infinite Helium |
| Pricing | Upon Request |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Model | RGC |
| Cooling Medium | Helium (gaseous & liquefied) |
| Operating Principle | Closed-loop cryogenic recirculation with pulse-tube or GM-based cold head |
| Compatible Cryostats | Lake Shore ST-100, ST-300, ST-400, ST-500, STVP series |
| Base Temperature (with ST-500) | ≤3.3 K (RGC4-20), ≤3.5 K (RGC4-15), ≤3.9 K (RGC4-12), ≤4.3 K (RGC4-10) |
| Cooling Power @ 5 K | up to 280 mW (RGC4-20) |
| Vibration Level (ST-500 + RGC) | <50 nm RMS (1–100 Hz) |
| Sample Exchange | Cold-insertion compatible (no warm-up required) |
| Compliance | Designed for GLP/GMP-adjacent research environments |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Model | SHI-950 |
| Cooling Type | Closed-cycle refrigeration |
| Temperature Range | 1.5 K to 800 K (300 mK with optional He-3 insert) |
| Typical Temperature Stability | ±50 mK |
| Sample Environment | Exchange gas |
| Sample Types | Solid, liquid, powder |
| Sample Exchange Time | <10 min |
| Cool-down Time | 8–9 h |
| Sample Cooling Time | ~80 min |
| Cryocooler Mounting | Top-mounted |
| Rotation Capability | Yes |
| Optical Window | Standard (configurable) |
| Sample Chamber Diameter | 51 mm (customizable) |
| Window Block Size | 108 mm square (standard) |
| Recommended Cryocooler Maintenance Interval | 13,000 h |
| Approximate Height | 142–168 cm |
| Approximate Weight | 113.4 kg |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | ST Series |
| Pricing | Available Upon Request |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Model | ST-100 |
| Cooling Method | Liquid Helium or Liquid Nitrogen Continuous-Flow |
| Temperature Range | 2 K to 500 K (ST-100) / 2 K to 800 K (ST-100-H) |
| Temperature Stability | ±50 mK |
| Sample Environment | High Vacuum (~10⁻⁵ Torr typical) |
| Optical Access | Yes, with standard optical windows |
| Cool-down Time | ≤15 min to 5 K |
| System Mass (excl. cryolines) | ~4.6 kg |
| Initial Cryogen Consumption (LHe, RT → base T) | 0.4 L |
| Steady-State LHe Consumption @ 5 K | 0.6 L/h |
| LN₂ Consumption @ 80 K | 0.1 L/h |
| Vacuum Requirement (initial) | ~10⁻³ Torr |
| Mounting Orientation | Omnidirectional |
| Sample Compatibility | Solid, thermally conductive specimens |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Model | ST-300 |
| Temperature Range | 2 K to 500 K |
| Temperature Stability | ±50 mK |
| Sample Environment | High Vacuum (Typical Operating Pressure: ~10⁻⁵ Torr) |
| Cooling Medium | Liquid Helium (down to 2 K) or Liquid Nitrogen (down to 77 K) |
| Cool-down Time to 5 K | ≤15 min |
| System Mass (excl. Transfer Lines) | ~4.6 kg |
| LN₂ Consumption @ 80 K | 0.1 L/h |
| LHe Consumption @ 5 K | 0.6 L/h |
| Initial LHe Fill (RT → Base Temp) | 0.4 L |
| Vacuum Requirement (Initial) | ~10⁻³ Torr |
| Optical Access | Standard Integrated Windows |
| Mounting Orientation | Omnidirectional |
| Compatibility | RGC Helium Recirculation Cryocooler (Helium-Free Operation) |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Model | ST-400 |
| Cooling Method | Liquid Helium (with optional RGC helium recirculator) |
| Temperature Range | 2 K to 500 K (ST-400) |
| Base Pressure | ≤1×10⁻¹¹ Torr |
| Temperature Stability | ±50 mK |
| Cool-down Time to 5 K | ≤15 min |
| Sample Environment | High-vacuum or ultra-high vacuum (UHV) chamber |
| Sample Mounting | Customizable sample holders (optical, DC, 4-probe, plug-in) |
| Optical Window Options | X-ray to THz spectral range |
| Electrical Feedthroughs | DC, BNC, SMA, triaxial |
| Initial LN₂ Consumption @ 80 K | 0.1 L/h |
| Liquid Helium Consumption @ 5 K | 0.6 L/h |
| System Mass (excl. transfer lines) | ~4.6 kg |
| Required Initial Pump-down | ~10⁻³ Torr |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Model | ST-500 |
| Temperature Range | 3.5 K to 475 K |
| Sample Environment | High Vacuum (1×10⁻⁵ Torr typical) |
| Vibration Level | ±15 nm RMS |
| Working Distance | As low as 1 mm |
| Cool-down Time | ~30 min to 5 K |
| Thermal Stability | ±50 mK |
| Optional Vacuum Extensions | LGV Large Vacuum Shroud, Superconducting Magnet & Electromagnet Integration Kits |
| Optical Window Options | X-ray to THz transmission range |
| Electrical Feedthrough Options | DC, BNC, SMA, Triaxial |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | STVP Series |
| Pricing | Upon Request |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | STVP-100 |
| Pricing | Upon Request |
| Cooling Medium | Liquid Helium or Liquid Nitrogen |
| Temperature Range | <2 K to 325 K (LHe), 65 K to 325 K (LN₂) |
| Temperature Stability | ±50 mK |
| Sample Environment | Continuous-flow cryogenic vapor |
| Cool-down Time to 5 K | 30 min |
| Optical Window | Optional |
| Top-Loading Configuration | Yes |
| Rotatable Sample Stage | Yes |
| Mounting Orientation | Vertical (required below 4.5 K) |
| Helium Consumption | 0.5 L (cooldown from RT to 4.2 K), 1.3 L/h (steady-state @ 5 K) |
| Height | 762 mm |
| Internal Sample Chamber Diameter | 38.1 mm |
| Sample Insertion Depth | 31 mm |
| Optical Window Block Size | 82.6 mm square |
| Weight (unit only) | 7 kg |
| Shipping Weight (unit + transfer line) | 61 kg |
| Shipping Dimensions | 1905 × 990.6 × 431.8 mm |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | STVP-FTIR / ST-FTIR / VPF-FTIR |
| Quotation | Upon Request |
| Temperature Range | 2 K to 500 K (STVP/ST), 65 K to 500 K (VPF) |
| Cooling Method | Liquid Helium (STVP/ST), Liquid Nitrogen (VPF) |
| Sample Environment | Flowing Vapor (STVP), High Vacuum (ST, VPF) |
| Temperature Stability | ±50 mK |
| Cool-down Time | ≤15 min to 5 K (STVP/ST), ≤15 min to 77 K (VPF) |
| Optical Access | Four Configurable Windows |
| Window Material Options | CaF₂, BaF₂, Sapphire, Polyethylene, Mylar, Silicon, Germanium (covering Far-IR to X-ray) |
| Translation Stage Travel | 51 mm |
| Sample Holder | 3-Position Rotatable Mount |
| Mounting Interface | Standard ISO-KF or CF Flange |
| Compatibility | Commercial FTIR Spectrometers (Bruker, Thermo Fisher, PerkinElmer, Nicolet) |
| Optional Accessories | Electrical Feedthroughs (DC, BNC, SMA, Triaxial), Custom Sample Stages (4-Probe, Plug-in, Optical), Vacuum-Compatible Thermometry (Cernox®, RuO₂, Diode) |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | STVP-NMR |
| Pricing | Upon Request |
| Temperature Range | <2 K (1.5 K in single-point mode) to 325 K (420 K optional) |
| Typical Temperature Stability | ±50 mK |
| Sample Environment | Continuous-flow helium vapor |
| Cooling Method | Liquid Helium |
| Cool-down Time | 30 min to 5 K |
| Sample Chamber Internal Diameter | 55 mm |
| Installation Orientation | Vertical (required below 4.5 K) |
| Liquid Helium Consumption | 0.5 L (from RT to 4.2 K) |
| Approx. Weight (unit only) | 7 kg |
| Approx. Shipping Weight | 79 kg |
| Approx. Shipping Dimensions | 1905 × 990.6 × 431.8 mm |
| Compatibility | Optimized for 89 mm bore NMR magnets, customizable for other bores |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Model | VNF-100 |
| Cooling Method | Liquid Nitrogen (LN₂) |
| Temperature Range | 65 K to 325 K (VNF-100) |
| Typical Temperature Stability | ±50 mK |
| Sample Environment | Flowing Nitrogen Vapor |
| Sample Types | Non-conductive & Conductive Solids, Liquids, Powders |
| Sample Exchange Time | ≤10 min |
| Cool-down to 77 K | ≤30 min |
| LN₂ Capacity | 1.2 L |
| Typical Hold Time | 6–8 h |
| Optical Window | Standard (VNF-100), Optional (VNF-100-TH) |
| Sample Chamber Inner Diameter | 30 mm (VNF-100), 22.35 mm (VNF-100-TH) |
| Height | 583 mm (VNF-100), 812.8 mm (VNF-100-TH) |
| Weight | 11.5 kg (net), 15.9 kg (shipping) |
| Shipping Dimensions | 762 × 508 × 431.8 mm |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | VPF-100 |
| Quotation | Upon Request |
| Cooling Method | Liquid Nitrogen (LN₂) Fill |
| Temperature Range | 65 K to 500 K (VPF-100), 65 K to 800 K (VPF-100-H) |
| Typical Temperature Stability | ±50 mK |
| Sample Environment | High Vacuum (~10⁻⁴ Torr) |
| Sample Types | Conductive, Solid |
| Cool-down Time to 77 K | 15 min |
| LN₂ Hold Time at 77 K | 8 h (VPF-100), 5 h (VPF-100-H) |
| LN₂ Hold Time at 100 K | 4.5 h |
| LN₂ Hold Time at 200 K | 2.5 h |
| Optical Window | Standard |
| Height (approx.) | 583 mm |
| Sample Chamber Inner Diameter | 76.2 mm (VPF-100), 63.5 mm (VPF-100-H) |
| Sample Mounting Diameter | 31.75 mm |
| Net Weight (approx.) | 3.3 kg |
| Shipping Weight (approx.) | 9.1 kg |
| Shipping Dimensions (approx.) | 610 × 406 × 305 mm |
| Brand | LANENDE Intelligent Technology |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | LD-DY24 |
| Price | USD 5,000 (FOB) |
| Brand | LANENDE Intelligent Technology |
|---|---|
| Model | LD-F8 |
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Category | Domestic Equipment |
| Price | USD 3,100 (approx.) |
| Dispensing Accuracy | ≤1.5% CV at 100 µL (96-well plate) |
| Minimum Dispense Volume | 5 µL |
| Throughput | Full 96-well plate in ≤12 s |
| Display | 7-inch color TFT touchscreen |
| Dispensing Mechanism | Precision peristaltic pump (non-contact) |
| Adjustable Flow Intensity | Dual-level (High/Low) |
| Waste Management | Removable waste tray with optional tubing for closed-loop waste collection |
| Brand | Langbo |
|---|---|
| Origin | Jiangsu, China |
| Model | CS-36 |
| Capacity | 36 L |
| Ultrasonic Frequency | 40 kHz |
| Ultrasonic Power | 600 W (adjustable) |
| Heating Power | 1800 W |
| Temperature Range | RT to 90 °C (adjustable, ±1 °C accuracy) |
| Timer Range | 1–999 min (adjustable) |
| Sound-Dampening Lid | Yes |
| Drain Valve | Yes |
| Rack Included | Yes |
| Power Supply | 220 V / 50 Hz |
| Type | General-purpose ultrasonic cleaner with thermostatic bath functionality |
| Brand | Langbo |
|---|---|
| Origin | Jiangsu, China |
| Model | DHG-9101-6SA |
| Temperature Range | RT+5°C to 300°C |
| Temperature Uniformity | ±3°C |
| Temperature Fluctuation | ±2°C |
| Temperature Resolution | 0.1°C |
| Internal Chamber Dimensions (W×D×H) | 1500 × 1000 × 1000 mm |
| External Dimensions (W×D×H) | 1860 × 1200 × 1300 mm |
| Chamber Material | SUS304 Stainless Steel |
| Heating Method | Forced-Air Circulation |
| Operating Ambient Temperature | Room Temperature Only |
| Compliance | Designed for GLP-compliant laboratory environments |
| Brand | Langbo |
|---|---|
| Model | DMK-1 |
| Temperature Range | −10 °C to 100 °C |
| Stability @ 100 °C | ≤ ±0.5 °C |
| Uniformity @ 40 °C | ≤ ±0.3 °C |
| Max. Module ΔT @ 40 °C | 0.3 °C |
| Display Resolution | 0.1 °C |
| Timer Range | 0–99 h 59 min |
| Heating Time (20 °C → 100 °C) | ≤15 min |
| Cooling Time (20 °C → −5 °C, 30 °C ambient) | ≤20 min |
| Cooling Time (20 °C → −10 °C, 25 °C ambient) | ≤30 min |
| Max. Power | 200 W |
| Dimensions (W×D×H) | 300 × 220 × 170 mm |
| Net Weight | 5 kg |
| Compliance | CE-marked design principles |
| Brand | Langbo |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | General Distributor |
| Product Category | Domestic |
| Model | HH-S |
| Instrument Type | Water/Oil Bath |
| Circulation Function | None |
| Temperature Control | Heating-Only |
| Bath Volume | 6–30 L |
| Temperature Range | Ambient to 300 °C |
| Temperature Stability | ±0.5 °C |
| Brand | Langbo Instruments |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HX-1030 |
| Price | USD 2,750 (FOB Jiangsu) |
| Temperature Range | −10 to 100 °C |
| Temperature Stability | ±0.05 °C |
| Chamber Dimensions | 400 × 325 × 230 mm (L×W×H) |
| Capacity | 30 L |
| Circulation Pump Flow Rate | 15 L/min |
| Opening Dimensions | 310 × 280 mm |
| Construction | Full Stainless Steel Interior and Work Surface |
| Control System | Digital Microprocessor-Based PID Controller with Dual Internal/External Circulation Modes |
| Safety Protections | Compressor Overheat & Overcurrent Protection |
| Optional Accuracy | ±0.01 °C or ±0.001 °C (with high-stability sensor and advanced PID tuning) |
| Brand | Langbo |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | LB-5E |
| Pricing | Available Upon Request |
| Temperature Control Range | 22.0 °C ± 2.0 °C |
| Alarm Thresholds | <20 °C or >24 °C |
| Oscillation Amplitude | 50 mm |
| Oscillation Frequency | 60 cycles/min |
| Oscillation Mode | Continuous horizontal reciprocating motion |
| Refrigeration System | Fan-cooled, R134a refrigerant |
| Compressor | Danfoss (Denmark) |
| Defrosting | Automatic |
| UV Sterilization | Integrated |
| Temperature Monitoring | Digital sensor with microprocessor control |
| Data Logging | Real-time LCD display with thermal printer interface |
| Ambient Operating Temperature | 5–35 °C |
| Input Voltage | 220–240 V AC, 50/60 Hz |
| Rated Current | 3.5 A |
| Cooling/Heating Power | 100 W each (IA-type) |
| External Dimensions (W×D×H) | 540 × 605 × 960 mm |
| Internal Chamber Dimensions (W×D×H) | 300 × 300 × 230 mm |
| Capacity | 5–10 platelet storage bags |
| Shelving | 5-tier adjustable rack |
| Brand | Langbo |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | LB-600 |
| Instrument Type | General-Purpose Ultrasonic Cleaner |
| Capacity | 600 L |
| Ultrasonic Frequencies | 25 kHz, 40 kHz, 80 kHz |
| Total Ultrasonic Power | 6 kW |
| Power Adjustment Range | 40–100% |
| Temperature Control Range | Ambient to 100 °C |
| Timer Range | 0–59 h 59 min |
| Sound-Dampening Lid | Included |
| Fill/Drain Fitting | Standard Integrated Ports |
| Tank Construction | Dual-layer stainless steel (SUS316 inner chamber, SUS304 outer shell) |
| Internal Dimensions | 750 × 740 × 550 mm |
| Heating Power | 3 kW (single-tank configuration), 6 kW (dual-tank option) |
| Input Power Supply | 220 V AC, 50 Hz |
| Custom Configurations | Available upon request |
| Brand | Langbo |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | LB-6000 |
| Instrument Type | Palm-Sized Centrifuge |
| Speed Range | 0–6,000 rpm |
| Max RCF | 1,600 × g |
| Max Capacity | 8 × 2.0 mL tubes |
| Rotor Configuration | Fixed-angle rotor (dual-standard: 1.5/2.0/0.5/0.2 mL tubes and 4 × 8-strip PCR tubes) |
| Dimensions | 150 × 120 × 180 mm (W × D × H) |
| Safety Features | Lid interlock, automatic rotor recognition, over-speed protection, imbalance detection |
| Housing Material | Reinforced polymer composite |
| Compliance | CE-marked per IEC 61010-1 for laboratory equipment safety |
| Brand | Langbo Instruments |
|---|---|
| Origin | Jiangsu, China |
| Model | LB-90 |
| Instrument Type | Precision Nitrogen-Purged Drying Oven |
| Temperature Range | RT+20°C to 250°C |
| Temperature Uniformity | ±1°C |
| Temperature Fluctuation | ±0.5°C |
| Control Resolution | 0.1°C |
| Internal Chamber Dimensions (W×D×H) | 300 mm × 250 mm × 80 mm |
| External Dimensions (W×D×H) | 450 mm × 400 mm × 350 mm |
| Heating Method | Forced-Air Electric Heating |
| Inner Chamber Material | Stainless Steel (AISI 304) |
| Power Supply | 220 V ±10%, 50/60 Hz |
| Rated Power | 500 W |
| Net Weight | ~20 kg |
| Nitrogen Inlet Pressure Range | 0.01–0.1 MPa |
| Flowmeter Range | 0.3–3.0 L/min |
| Max. Air Exchange Rate | 15 air changes per hour |
| Compliance Standards | GB/T 211–2007, GB/T 212–2008 |
| Brand | Langbo |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | LBSW-5E |
| Quotation | Upon Request |
| Temperature Control Range | 22.0 °C ± 2.0 °C |
| Alarm Thresholds | < 20 °C or > 24 °C |
| Oscillation Amplitude | 50 mm |
| Oscillation Frequency | 60 cycles/min |
| Oscillation Mode | Continuous horizontal reciprocating motion |
| Refrigeration System | Fan-cooled, R134a refrigerant |
| Compressor | Danfoss (Denmark) |
| Defrosting | Automatic |
| UV Sterilization | Integrated |
| Power Supply | 220–240 V AC, 3.5 A, 50/60 Hz |
| Cooling/Heating Power | 100 W each (IA-type) |
| External Dimensions (W×D×H) | 540 × 605 × 960 mm |
| Internal Chamber Dimensions (W×D×H) | 300 × 300 × 230 mm |
| Capacity | 5–10 platelet storage bags |
| Shelving | 5-tier adjustable stainless-steel racks |
| Ambient Operating Temperature | 5–35 °C |
| Data Logging | Real-time temperature recording with thermal printer output |
| Display | LCD interface with microprocessor-based control |
| Brand | Langbo |
|---|---|
| Model | LBSW-7E |
| Temperature Control Range | 22.0 °C ± 2.0 °C |
| Alarm Thresholds | <20 °C, >24 °C, Power Failure |
| Oscillation Mode | Continuous Horizontal Reciprocating |
| Stroke | 50 mm |
| Frequency | 60 cycles/min |
| Brand | Langbo |
|---|---|
| Model | MK-1 |
| Temperature Range | RT + 5°C to 150°C |
| Temperature Stability | ±0.5°C (40–100°C), ±1.0°C (100–150°C) |
| Uniformity Across Block | ≤ ±0.5°C |
| Max ΔT Within Block at 40°C | 0.3°C |
| Display Resolution | 0.1°C |
| Timer Range | 1 min to 99 h 59 min |
| Heating Time | ≤30 min (20°C → 150°C) |
| Block Dimensions | 96 × 96 × 49 mm |
| Compliance | CE-marked, RoHS-compliant, GLP-ready design |