| Brand | Rudolph |
|---|---|
| Origin | USA |
| Model | J-Series Refractometer Module |
| Product Type | Benchtop Refractometer |
| Temperature Control | Yes (Dual-zone semiconductor Peltier) |
| Digital Display | Yes (10.4" color TFT touchscreen) |
| Measurement Range | 1.26–1.72 RI, 0–100 Brix |
| Measurement Resolution | 0.00001 RI |
| Accuracy | ±0.00002 RI, ±0.015 Brix |
| Temperature Control Range | 10–110 °C (120 °C optional) |
| Temperature Stability | ±0.01 °C |
| Prism Material | Sapphire |
| Interface | RS-232, USB, Cat5 Ethernet |
| Compliance | NIST-traceable calibration standards available |
| Design | Modular split architecture (separate measurement head and control unit) |
| Brand | TE / Trace Elemental Instruments |
|---|---|
| Origin | Netherlands |
| Model | XPLORER-V with VECTRA Liquid Autosampler |
| Analytical Method | Combustion Microcoulometry |
| Measurement Range | 0–10,000 ppm |
| Accuracy | ≤2% CV |
| Detection Limit | 10 ppb |
| Resolution | ≤2% CV |
| Brand | Formulaction |
|---|---|
| Origin | France |
| Model | TURBISCAN LAB |
| Measurement Principle | Static Multiple Light Scattering (MLS) |
| Wavelength | 880 nm (pulsed NIR source) |
| Scan Height | 55 mm |
| Spatial Resolution | 20 µm |
| Temp. Range | +5 °C above ambient to 60 °C |
| Temp. Control Accuracy | ±0.5 °C |
| Particle Size Range | 0.01–1000 µm |
| Max. Concentration | 95% v/v |
| Detectors | Dual photodiode (transmission + backscattering) |
| Sample Cell | Cylindrical glass cell (Ø 27.5 mm × H 55 mm), threaded black cap with butyl/PTFE seal |
| Data Acquisition Modes | Full-height scanning (1 scan/20 s) or fixed-position kinetics (1 measurement/s) |
| Max. Scan Programs | 250 |
| Software Output | BS/T vs. time, layer thickness vs. time, particle migration velocity, hydrodynamic diameter (d), volume fraction (φ), mean free path, TSI Stability Index, dispersion index |
| Brand | Biolin Scientific |
|---|---|
| Origin | Finland |
| Model | Theta Flow with 3D Topography Module |
| Instrument Type | Benchtop Video-Based Optical Contact Angle Analyzer |
| Contact Angle Range | 0–180° |
| Contact Angle Accuracy | ±0.01° |
| Contact Angle Resolution | 2592 × 2048 (5.3 MP) |
| Surface Tension Range | 0.01–2000 mN/m |
| Surface Tension Accuracy | ±0.01 mN/m |
| Sample Stage Dimensions | Unlimited (L) × 100 mm (W) × 320 mm (D) |
| Max Sample Size | Unlimited (L) × 320 mm (W) × 22 mm (H) |
| Imaging Sensor | 5.3 MP CMOS, 2592 × 2048 pixels |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Configuration | Benchtop/Polarized EDXRF |
| Element Range | Na (11) to Am (95), optional C (6) to Am (95) |
| Concentration Range | ppm to 100% |
| Energy Resolution | <135 eV (Mn Kα) |
| Repeatability | <0.1% RSD |
| Detector | HighSense™ Ultra-Low-Noise Silicon Drift Detector (SDD) |
| Compliance | ASTM D6481, ASTM D7751, ASTM D7220, ISO 13032, ASTM D4294, ISO 20847, ISO 8754, IP 336/496/532, JIS K2541-4, GB/T 11140 |
| Brand | Novasina |
|---|---|
| Origin | Switzerland |
| Model | LabTouch-aw |
| Measurement Range | 0.030–1.000 aw |
| Temperature Control Range | 15–30 °C |
| Accuracy | ±0.001 aw |
| Temperature Accuracy | ±0.1 °C |
| Display | Full-color TFT touchscreen |
| Probe Type | Patented Resistive Electrolyte Sensor (REMS) |
| Standard Reference | Long-life saturated salt solution standards |
| Host Weight | 1 kg |
| Compliance | NIST-traceable calibration, FDA-recognized methodology, ISO 21807, AOAC 975.34, USP <1112> |
| Brand | Formulaction (Microtrac) |
|---|---|
| Origin | France |
| Model | Rheolaser Master |
| Instrument Type | Optical Microrheometer |
| Sample State | Liquid |
| Measurement Principle | Multi-Speckle Diffusing Wave Spectroscopy (MS-DWS) |
| Temperature Range | +5°C above ambient to 90°C (optional up to 150°C) |
| Frequency Range | 10⁻⁴ Hz to 10² Hz |
| RMS Particle Displacement Range | 0.1 nm – 100 nm |
| Minimum Detectable Particle Size | 50 nm |
| Maximum Solid Volume Concentration | 90% v/v |
| Torque Specifications | Not applicable (non-mechanical, optical measurement) |
| Data Acquisition | High-resolution CMOS camera-based speckle image analysis |
| Sample Holder | 20 mL borosilicate glass cuvette with 6-position sample carousel |
| Brand | Particle Metrix |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ZetaView® Evolution |
| Zeta Potential Range | ±500 mV |
| pH Range | 1–13 |
| Operating Temperature Range | 5°C to 55°C |
| pH Resolution | 1–13 |
| Temperature Resolution | 0.1°C |
| Size Accuracy | ±5 nm |
| Size Repeatability | ±2 nm |
| Brand | TE / Trace Elemental Instruments |
|---|---|
| Origin | Netherlands |
| Model | XPLORER-V with XLS-26 Liquid Autosampler |
| Detection Principle | UV Fluorescence (S) / Chemiluminescence (N) |
| Portability | Benchtop (Non-portable) |
| Analyte Types | Total Sulfur and Total Nitrogen |
| Measurement Range | 20 ppb – 10,000 ppm |
| Analysis Time | 2–6 minutes per sample |
| LOD | 10 ppb (S and N) |
| Accuracy | ±2% of reading |
| Brand | Microtrac |
|---|---|
| Origin | Japan |
| Model | BELSORP MINI X |
| Instrument Type | Specific Surface Area and Pore Size Analyzer |
| Principle | Static Volumetric Gas Adsorption (Combined with Dynamic Pre-evacuation) |
| Analysis Stations | 4 |
| Surface Area Range | ≥0.01 m²/g (no upper limit) |
| Pore Size Range | 0.35–500 nm |
| Pressure Range | 0–133.3 kPa |
| Measurement Theory | Static Volumetric Method + Advanced Free Space Monitoring (AFSM™) |
| Compliance Options | FDA 21 CFR Part 11, IQ/OQ Documentation Package Available |
| Brand | Thermo Fisher |
|---|---|
| Origin | Italy |
| Model | FlashSmart |
| Element Range | CHNSO, CHNS, CHN, NCS, NC, N, S, O (configurable modes) |
| Analysis Time | 5–10 min (sample-weight- and matrix-dependent) |
| Detection Limit | <40 ppm (S: down to 4 ppm with FPD/IR |
| Measurement Precision | ≤0.05% RSD |
| Sample Introduction | Up to 500 µL liquid or 1 g solid |
| Detector Options | Thermal Conductivity Detector (TCD), Flame Photometric Detector / Infrared Detector (FPD/IR), Isotope Ratio Mass Spectrometer (IRMS) interface, Chlorine (Cl) measurement module |
| Combustion Temperature | Up to 1800 °C |
| Compliance | Designed for GLP/GMP environments |
| Brand | LS Instruments |
|---|---|
| Origin | Switzerland |
| Model | LSI Correlator |
| Application Scope | Dynamic Light Scattering (DLS), Fluorescence Correlation Spectroscopy (FCS), Diffusing Wave Spectroscopy (DWS), Diffuse Correlation Spectroscopy (DCS) |
| Correlation Algorithm | Multi-tau and Linear-tau Digital Correlation |
| Time Delay Range | 12.5 ns – 3436 s (13 decades) |
| Number of Channels | 322 total (296 detection + 26 auxiliary) |
| Fastest Configurable Initial Delay | 12.5 ns, 200 ns, 400 ns, 800 ns, or 3200 ns |
| Normalization Modes | Symmetric and Compensation Normalization |
| Max. Count Rate | 20 Mcps (at 52 ms integration) |
| Interface | USB 2.0 and Gigabit Ethernet |
| OS Support | Windows & Linux |
| Firmware Upgradability | Field-upgradable via host software |
| Power Supply | External stabilized DC source |
| Dimensions | 120 × 120 × 53.6 mm (aluminum housing) |
| Detector Protection | Real-time gated output with user-defined count-rate threshold |
| Synchronization | Dedicated clock output for hardware timing alignment |
| Software Integration | Native APIs for MATLAB, LabVIEW, Python |
| Brand | LS Instruments |
|---|---|
| Origin | Switzerland |
| Model | NanoLab 3D |
| Particle Size Range | 0.3 nm – 10 µm |
| Sample Volume | as low as 4 µL (optional) |
| Temperature Control Range | 4 °C – 85 °C |
| Viscosity Measurement Range | 0.01 cP – >1000 cP |
| Compliance | ISO 22412 (at ≤23 °C ambient) |
| Technique | Modulated 3D Cross-Correlation DLS |
| Brand | Trace Elemental Instruments |
|---|---|
| Origin | Netherlands |
| Model | XPLORER TX/TS |
| Detection Principle | Combustion Microcoulometry |
| Sample Types | Solids, Liquids, Gases, LPG |
| Measurement Range (S) | 0.0020–500 mg |
| Measurement Range (Cl) | 0.0025–1000 mg |
| LOD (S) | 0.020 mg/L |
| LOD (Cl) | 0.025 mg |
| Combustion Furnace Temperature | 1050 °C |
| Software | TEIS 2 Professional |
| Brand | Formulaction |
|---|---|
| Origin | France |
| Model | TURBISCAN TOWER |
| Detection Principle | Multiple Light Scattering (MLS) |
| Wavelength | 880 nm (pulsed NIR source) |
| Sample Capacity | 6 positions |
| Temperature Range | 4–80 °C |
| Temp. Control Accuracy | ±0.1 °C |
| Scan Height | 55 mm |
| Spatial Resolution | 20 µm per data point |
| Scan Interval | ≥20 s (user-configurable) |
| Particle Size Range | 0.01–1000 µm |
| Max. Concentration | 95% v/v |
| Measurement Modes | Transmission (T) and Backscattering (BS) |
| Software Compliance | FDA 21 CFR Part 11 ready, audit trail enabled, GLP/GMP-supportive workflows |
| Brand | Biolin Scientific |
|---|---|
| Origin | Finland |
| Model | Sigma 701 |
| Measurement Range | 1–2000 mN/m |
| Resolution (Surface Tension) | 0.001 mN/m |
| Accuracy (Surface Tension) | ±0.01 mN/m |
| Temperature Control Range | −20 to +200 °C |
| Temperature Resolution | 0.01 °C |
| Measurement Methods | Du Noüy Ring Method, Wilhelmy Plate Method |
| Density Range | 0–2.2 g/cm³ |
| Density Resolution | 0.0001 g/cm³ |
| Force Resolution | 0.05–0.1 µN |
| Contact Angle Range | 0–180° |
| Contact Angle Resolution | 0.01° |
| Motorized Stage Speed | 0.01–500 mm/min |
| Stage Positioning Accuracy | 0.016 µm |
| Dimensions (W×D×H) | 33.3 × 24.4 × 62 cm |
| Weight | 13–16 kg |
| Power Supply | 85–264 VAC, 47–440 Hz, 13 W |
| Brand | TE/Trace Elemental Instruments |
|---|---|
| Origin | Netherlands |
| Model | XPLORER NS |
| Detection Principle | UV Fluorescence for Sulfur / Chemiluminescence for Nitrogen |
| Sample Types | Liquids, Gases, LPG, Solids |
| Measurement Range | S and N from sub-ppb to percent level |
| Combustion Furnace Temperature | 1050 °C |
| Software | TEIS 2 Professional Control & Data Management Software |
| Compliance | ASTM D5453, D7183, D7184 |
| Optional Autosamplers | 105-position 2-mL vial XYZ autosampler (with auto-dilution & auto-calibration), Gas/LPG autosampler, 20-position solid autosampler |
| Detector | Temperature-controlled UVF and CLD detectors with active feedback loops |
| Automation Level | Fully automated combustion, gas flow control, calibration, and data validation |
| Brand | Porometer |
|---|---|
| Model | POROLUX™ Revo X |
| Origin | Germany |
| Measurement Principle | Gas-Liquid Capillary Flow (Capillary Flow Porometry, CFP) |
| Pore Size Range | 80 nm – 500 µm |
| Bubble Point Pressure Range | 0–8 bar (0–116 psi) |
| Max. Gas Flow Rate | 200 L/min |
| Dual Auto-Switching Flow Sensors | 0–10 L/min & 0–200 L/min |
| Dual Auto-Switching Pressure Sensors | 0–1 bar & 0–10 bar |
| Sample Holder Diameter | 25 mm |
| Max. Sample Thickness | 3 mm |
| Measurement Modes | Bubble Point (BP x-mL, BP pCF), Mean Flow Pore Size, Minimum Pore Size, Pore Size Distribution, Cumulative Flow Distribution, Gas Permeability |
| Optional Modules | Liquid Permeability, Fluid Source Integration |
| Software | PoreSmart™ with Curve Fitting, Statistical Pore Quantification (Total Pore Count, Total Pore Area [% & µm²], Open Porosity, Calculated Permeability in Darcy) |
| Patented Measurement Method | MP² (Multi-Step Pressure Progression) Technology |
| Compliance Ready | ASTM F316-22, ISO 15709:2022, USP <801>, GLP/GMP Data Integrity Support (Audit Trail, Electronic Signatures, 21 CFR Part 11 Ready) |
| Brand | Formulaction |
|---|---|
| Origin | France |
| Model | TURBISCAN DNS |
| Measurement Principle | Static Multiple Light Scattering (SMLS) |
| Detection Modes | Transmittance (T) and Backscattering (BS) |
| Sample Volume | 1.5–30 mL |
| Concentration Range | 0.0001–95% v/v |
| Particle Size Range | 10 nm–1 mm |
| Spatial Resolution | Vertical scanning with high-frequency acquisition |
| In-situ Options | T-MIX (stirred mode), T-LOOP (circulation mode) |
| Output Metric | Turbiscan Stability Index (TSI) |
| Brand | Octopus |
|---|---|
| Origin | Germany |
| Model | SAMILLA FIM |
| Detection Principle | High-Resolution Flow Imaging Microscopy (HiRes-FIM) |
| Particle Size Range | 0.2 µm – 2 mm |
| Camera Options | 12 MP monochrome or color, high-frame-rate sensor |
| Auto-focus | Real-time autofocus without focus beads |
| Magnification Switching | Tool-free, RFID-recognized modular objectives |
| Compliance | USP <788>, USP <789>, Ph. Eur. 2.9.19, ISO 14644-1, FDA 21 CFR Part 11, GLP/GMP-ready |
| Software | SMILLA View v5.x with audit trail, electronic signatures, LIMS integration via ASTM E1384 / LADS framework |
| Cleaning | Fully automated post-run rinse and backflush cycle |
| Pump Configurations | MACRO (peristaltic), MICRO1 (single syringe), MICRO2 (dual alternating syringe), HYBRID (peristaltic + syringe) |
| Brand | Biolin Scientific |
|---|---|
| Origin | Finland |
| Model | Theta Lite |
| Instrument Type | Benchtop Video Optical Contact Angle Analyzer |
| Contact Angle Measurement Range | 0–180° |
| Contact Angle Resolution | 0.01° |
| Contact Angle Accuracy | ±0.1° (standard), ±0.01° (high-precision mode) |
| Surface & Interfacial Tension Range | 0.01–2000 mN/m |
| Surface & Interfacial Tension Accuracy | ±0.1 mN/m (standard), ±0.01 mN/m (high-precision mode) |
| Camera Resolution | 1936 × 1216 pixels |
| Sample Stage Dimensions (L×W×H) | 495 × 130 × 310 mm |
| Max. Sample Weight Capacity | 5 kg |
| Image Magnification | Fixed optical path with high-magnification telecentric lens system |
| Measurement Modes | Static CA, Advancing/Receding CA, Roll-off Angle, Surface Free Energy (Owens-Wendt, Wu, van Oss), Interfacial Tension, Batch Analysis, Roughness-Corrected CA, Single-Fiber CA |
| Software | OneAttension v4.x (FDA 21 CFR Part 11 compliant audit trail option available) |
| Brand | Microtrac |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | BELMASS II |
| Instrument Type | Chemisorption Analyzer with Integrated Online MS Detection |
| Gas Inlet Ports | Up to 16 |
| Temperature Stability | ±0.001 °C |
| Supported Techniques | TPD, TPR, TPS, Pulse Titration, BET Surface Area Analysis (via coupled gas dosing) |
| Mass Range | 1–200 amu |
| Detector | Faraday Cup / Continuous Dynode Electron Multiplier (C-SEM) |
| Minimum Detectable Concentration | <1 ppm (gas-dependent) |
| Scan Speed Options | Auto, 0.01–10 sec per amu (selectable) |
| Detection Channels | Up to 16 simultaneous mass channels |
| Sample Interface | Heated capillary transfer line (up to 300 °C), integrated dry scroll pump |
| Brand | Biolin Scientific |
|---|---|
| Origin | Finland |
| Model | Sigma 703D |
| Measurement Range | 1–1000 mN/m |
| Resolution | 0.01 mN/m |
| Accuracy | ±0.01 mN/m |
| Temperature Display Range | −20 to +200 °C |
| Temperature Display Accuracy | ±0.01 °C |
| Measurement Methods | Du Noüy Ring Method, Wilhelmy Plate Method |
| Density Range | 0–2.2 g/cm³ |
| Density Resolution | 0.0001 g/cm³ |
| Force Resolution | 0.1 µN |
| Weight | 11 kg |
| Dimensions (W×D×H) | 33.3 × 24.4 × 62 cm |
| Power Supply | 85–264 VAC, 47–440 Hz, 13 W |
| Brand | Thermo Fisher |
|---|---|
| Origin | Italy |
| Instrument Type | Dumas Combustion Method |
| Automation Level | Fully Automated Nitrogen Determinator |
| Nitrogen Range | 0.001–500 mg N |
| Reproducibility | <0.3% RSD |
| Sample Weight | ≥1 g |
| Recovery Rate | 99.5–100% |
| Digestion/Combustion Time | 3–4 min per sample |
| Power Consumption | 1400 W |
| Dimensions (L×W×H) | 620 × 580 × 500 mm |
| Linearity Range | 0.001–500 mg N |
| Sample Capacity | Up to 125 positions (with optional multi-rack configuration) |
| Gas Flow Control | Electronic Flow Control (EFC) |
| Software Platform | EagerSmart™ Operating Software |
| Compliance | ASTM D515, ISO 13878, AOAC 992.15, USP <467>, EN ISO 13878, and GLP/GMP-ready audit trail support |