- All
- Favorite
- Popular
- Most rated
| Brand | Countstar |
|---|---|
| Origin | Shanghai, China |
| Model | IC1000 |
| Measurement Time | <20 s |
| Cell Concentration Range | 1×10⁴–3×10⁷ cells/mL |
| Sample Volume | 20 µL |
| Throughput | 5 samples per slide |
| Detectable Cell Diameter | 5–180 µm |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model Capacity Range | 22 L to 707 L |
| Pricing | Available Upon Request |
| Brand | MMM |
|---|---|
| Origin | Germany |
| Model | CLC |
| Temperature Range (with humidification) | −20 °C to 160 °C |
| Temperature Uniformity | ±0.1 °C |
| Humidity Range | 10–95 % RH |
| Chamber Volume | 111–1212 L |
| Brand | Biogenstar |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Regional Classification | Domestic (China) |
| Model | BCTF |
| Quotation | Upon Request |
| Temperature Range | Ambient to 50 °C |
| Working Volume Range | 0.1–0.4 L |
| Brand | Countstar |
|---|---|
| Origin | Shanghai, China |
| Model | Mira FL Pro |
| Detection Time | 20–50 s |
| Sample Volume | 20 µL |
| Throughput | 5 samples per run |
| Optical Magnification | 10× |
| Imaging Sensor | 8.3 MP CMOS |
| Compatible Consumables | Standard Countstar counting chambers & newly developed 60-µm-depth chambers |
| Regulatory Compliance | FDA 21 CFR Part 11, GMP-aligned |
| Validation Support | Full 3Q (IQ/OQ/PQ) documentation available |
| Data Management | Audit trail, user access control, server & printer integration |
| Brand | Countstar |
|---|---|
| Origin | Shanghai, China |
| Model | AItair |
| Detection Time | 150 s |
| Cell Concentration Range | 1×10⁴–3×10⁷ cells/mL |
| Sample Volume | 20 µL |
| Throughput | 5 samples per run |
| Detectable Cell Diameter | 3–180 µm |
| Brand | Countstar |
|---|---|
| Origin | Shanghai, China |
| Model | Rigel |
| Detection Time | <20 s |
| Cell Concentration Range | 1×10⁴–3×10⁷ cells/mL |
| Sample Volume | 20 µL |
| Throughput | 5 samples per run |
| Detectable Cell Diameter | 3–180 µm |
| Fluorescence Channels | Up to 13 (4 excitation sources + 5 emission filter combinations) |
| Regulatory Compliance | CE-marked, FDA 21 CFR Part 11–compliant software architecture |
| Intended Use | Research use only (RUO), not for diagnostic purposes |
| Brand | Countstar |
|---|---|
| Origin | Shanghai, China |
| Model | Castor X |
| Fluorescence Channels | Dual (Green & Red) |
| Compatible Vessels | 6/12/24/96/384-well plates, Petri dishes, culture flasks |
| Imaging Sensor | Cooled high-resolution monochrome CMOS camera |
| Analysis Engine | AI-powered deep learning algorithms for clonal identification, confluency quantification, and transfection efficiency scoring |
| Software | Modular, GLP-compliant with audit trail and user permission management |
| Regulatory Alignment | Designed to support ISO 13485 workflows and FDA 21 CFR Part 11–ready data integrity practices |
| Brand | Countstar |
|---|---|
| Origin | Shanghai, China |
| Model | IY1200 |
| Detection Time | <20 s |
| Cell Concentration Range | 5×10⁴–3×10⁷ cells/mL |
| Sample Volume | 20 µL |
| Throughput | 5 samples per run |
| Detectable Cell Size | 2–180 µm |
| Brand | Countstar |
|---|---|
| Origin | Shanghai, China |
| Model | Mira HT |
| Detection Concentration Range | 1 × 10⁴ – 3 × 10⁷ cells/mL |
| Sample Volume | 20 µL |
| Throughput | 24 samples (standard) / 15 samples (fluorescence mode) |
| Detectable Cell Size | 1–180 µm |
| Imaging Sensor | 8.3 MP CMOS |
| Optical Resolution | Optimized for ≥2× field area vs. standard hemocytometer |
| Trypan Blue Mode Acquisition Time | <10 s per image |
| AO/PI Dual-Fluorescence Mode Acquisition Time | <22 s per image |
| Total Analysis Time per Sample | <30 s (brightfield), <60 s (fluorescence) |
| Software Compliance | FDA 21 CFR Part 11, GLP/GMP-ready audit trail, 3Q validation support |
| Brand | Countstar |
|---|---|
| Origin | Shanghai, China |
| Model | IA1000 |
| Analysis Time | <20 s |
| Detection Concentration Range | 5×10⁴–5×10⁷ cells/mL |
| Sample Volume | 20 µL |
| Throughput | 5 samples per run |
| Detectable Cell Size Range | 2–180 µm |
| Brand | Countstar |
|---|---|
| Origin | Shanghai, China |
| Model | IM1200 |
| Detection Time | <20 s |
| Cell Concentration Range | 5×10⁴–5×10⁷ cells/mL |
| Sample Volume | 20 µL |
| Throughput | 5 samples per run |
| Detectable Cell Diameter | 2–180 µm |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model Options | 111L, 222L, 404L, 707L |
| Pricing | Upon Request |
| Brand | MMM |
|---|---|
| Origin | Germany |
| Model Range | Friocell 22L, 55L, 111L, 222L, 404L, 707L, 1212L |
| Temperature Range | −10 °C to 99.9 °C (model-dependent |
| Friocell 22 | 5–70 °C |
| Friocell 1212 | 0–70 °C) |
| Display | 3-inch LCD (7.6 cm), digital setpoint resolution 0.1 °C |
| Chamber Material | AISI 304 stainless steel |
| Air Circulation | Top-mounted stainless-steel fan generating upward spiral airflow |
| Safety System | Independent adjustable temperature safety device (EU Class 3.1), visual & audible alarm |
| Compliance | CE, ISO 13485, compliant with ICH guidelines, USP <1031>, and Chinese Pharmacopoeia 2015 edition |
| Interfaces | RS232, USB, BMS relay contact alarm |
| Software | Warmcomm data logging & remote monitoring |
| Programmability | Up to 16-step profiles (temperature, fan speed, duration, ramp rates) |
| Accessories | Optional LED lighting modules, PT-100 probe ports, stainless-steel trays, printer interface, side access ports, IQ/OQ/PQ validation documentation |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Incucell, Incucell V |
| Pricing | Upon Request |
| Chamber Volumes | 22 L, 55 L, 111 L, 222 L, 404 L, 707 L |
| Internal Dimensions (W×D×H, cm) | 40×39×35 / 54×39×53 / 54×52×76 / 54×52×141 / 94×52×141 |
| External Dimensions (W×D×H, cm) | 62×64×88 / 76×64×106 / 76×79×130 / 101×79×191 / 141×79×191 |
| Temperature Range | +5 °C to 99.9 °C above ambient |
| Temperature Uniformity | ±0.3 °C (at 37 °C, natural convection) |
| Temperature Stability | ±0.1 °C |
| Heating Control | Microprocessor-based PID algorithm with fuzzy logic compensation |
| Chamber Material | AISI 304 stainless steel interior |
| Door | Double-glazed, low-emissivity inner glass door with ergonomic elbow-actuated opening mechanism |
| Air Filtration | Optional 0.3 µm HEPA-grade particulate filter (Incucell V only) |
| Sterilization | Dry-heat compatible up to 180 °C (validated for chamber and internal components) |
| Safety Certification | EN 61010-1 Class III.1 temperature safety cut-off |
| Communication Interface | RS232 serial port (standard), BMS relay alarm output |
| Software | Warmcomm data logging and remote monitoring suite |
| Validation Support | IQ/OQ/PQ documentation package available upon request |
| Regulatory Compliance | Designed and tested per IEC 61010-1, ISO 13485-aligned manufacturing controls, supports FDA 21 CFR Part 11-compliant audit trails when used with validated Warmcomm configuration |
| Brand | Countstar |
|---|---|
| Origin | Shanghai, China |
| Model | Mira FL |
| Detection Time | 20–50 s |
| Cell Concentration Range | 1×10⁴–3×10⁷ cells/mL |
| Sample Volume | 20 µL |
| Throughput | 5 samples per run |
| Detectable Cell Diameter | 1–180 µm |
| Brand | Hvita |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | Hvita |
| Pricing | Available Upon Request |
| Brand | Countstar |
|---|---|
| Origin | Shanghai, China |
| Model | Countstar Spica |
| Type | Label-Free Live-Cell Imaging System |
| Optical Configurations | Spica M1 (7.5×/10×/15× |
| 3-channel fluorescence | DAPI/GFP/RFP |
| 4-channel fluorescence | DAPI/GFP/RFP/APC |
| Environmental Integration | Incubator-compatible (37 °C, 5% CO₂, humidity control) |
| Software | AI-powered analysis platform with ≥12 pre-validated application modules, FDA 21 CFR Part 11–compliant audit trail (optional), GLP/GMP-ready data export (CSV, TIFF, JSON, PDF) |
| Brand | Biogenstar |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | CTF |
| Pricing | Available Upon Request |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | FITOCLIMA 600 & 1200 BIO |
| Price | Upon Request |
| External Dimensions (H×W×D, mm) | 1980×720×945 (600) / 1975×1440×810 (1200) |
| Internal Dimensions (H×W×D, mm) | 1330×600×650 (600) / 1330×1320×650 (1200) |
| Temperature Range | +5 °C to +45 °C (light ON), –5 °C to +45 °C (light OFF) |
| Temperature Uniformity | ±1.0 °C |
| Temperature Accuracy | ±0.5 °C |
| Humidity Range | 40–80% RH (light ON), 40–90% RH (light OFF) |
| Humidity Accuracy | ±1% RH |
| Humidity Uniformity | ±2% RH |
| Adjustable Shelves | 1–4 levels (600), 2–8 levels (1200), all with independent lighting control |
| Brand | Countstar |
|---|---|
| Origin | Shanghai, China |
| Model | Mira FL Plus |
| Measurement Time | 20–50 s |
| Cell Concentration Range | 1×10⁴ – 3×10⁷ cells/mL |
| Sample Volume | 20 µL |
| Throughput | 5 samples per run |
| Detectable Cell Size Range | 1–180 µm |
| Imaging Sensor | 8.3 MP CMOS |
| Optical Resolution | Enhanced via fixed-focus optical architecture |
| Fluorescence Channels | AO/PI, GFP, RFP |
| Compliance | FDA 21 CFR Part 11, GMP-aligned data integrity framework |
| Brand | Countstar |
|---|---|
| Origin | Shanghai, China |
| Model | IE1000 |
| Measurement Time | <20 s |
| Cell Concentration Range | 1×10⁴–3×10⁷ cells/mL |
| Sample Volume | 20 µL |
| Throughput | 5 samples per slide |
| Detectable Cell Diameter | 5–180 µm |
| Brand | PEA |
|---|---|
| Origin | Germany |
| Model | PEA VHP Series |
| Sterilization Agent | Vaporized Hydrogen Peroxide (VHP) |
| Sterility Assurance Level (SAL) | ≤10⁻⁶ |
| Log Reduction | ≥6-log against Geobacillus stearothermophilus (ATCC 12980 / ATCC 7953) |
| Filtration Class | ISO 14644-1 Class 5 (H14 HEPA) |
| Cycle Time | ~60 min |
| Operating Conditions | Ambient pressure, low-temperature (≤35 °C) |
| Decomposition Byproducts | H₂O and O₂ only |
| Compliance | EU GMP Annex 1, US FDA 21 CFR Part 11, ISO 14644, ISO 15883, EN 17175 |
| Brand | Countstar |
|---|---|
| Origin | Shanghai, China |
| Model | Mira BF |
| Detection Time | 20–50 s |
| Cell Concentration Range | 1×10⁴ – 3×10⁷ cells/mL |
| Sample Volume | 20 µL |
| Throughput | 5 samples per run |
| Detectable Cell Diameter | 2 – 180 µm |
Show next