| Brand | Lufft |
|---|---|
| Origin | Imported |
| Model | CHM15K |
| Laser Source | Solid-State Nd:YAG (1064 nm) |
| Detector Type | Avalanche Photodiode (APD) |
| Maximum Detection Range | 15 km |
| Pulse Repetition Frequency | 100 Hz |
| Vertical Resolution | 5 m |
| Temporal Resolution | Adjustable (1–60 s) |
| Data Output Formats | NetCDF, ASCII, BUFR |
| Communication Interfaces | Ethernet (TCP/IP), RS-485 |
| Environmental Operating Range | −40 °C to +60 °C |
| Enclosure | Dual-layer heated & ventilated housing |
| Calibration | Optional on-site calibration kit available |
| Compliance | WMO Guide to Instruments and Methods of Observation (CIMO Guide), ISO 9001-certified manufacturing |
| Brand | Lufft |
|---|---|
| Origin | Imported |
| Model | CHM8K |
| Laser Source | Laser Diode |
| Detector | Avalanche Photodiode (APD) |
| Operating Wavelength | 905 nm |
| Maximum Detection Height | 8 km |
| Pulse Repetition Frequency | 100 Hz |
| Data Output Formats | NetCDF, ASCII, BUFR |
| Communication Interfaces | Ethernet (TCP/IP), RS-485 |
| Environmental Operating Range | −40 °C to +60 °C (with integrated heating/cooling system) |
| Cloud Layer Detection Capacity | Up to 9 cloud layers + 2 aerosol layers |
| Signal Processing | Real-time enhanced wavelet transform algorithm |
| Brand | Lufft |
|---|---|
| Origin | Imported |
| Model | V200A-UMB |
| Instrument Type | Ultrasonic Anemometer |
| Resolution | 0.1 m/s |
| Measurement Range | 0–90 m/s |
| Accuracy | ±0.3 m/s or ±3% RMS (0–35 m/s), whichever is greater |
| Operating Temperature | −40 to +60 °C (with integrated heater) |
| Relative Humidity Range | 0–100% RH |
| Output Interfaces | Digital (RS-485, SDI-12, Modbus RTU) and Configurable Analog (4–20 mA, 0–10 V, or frequency output) |
| Measured Parameters | Wind Speed, Wind Direction, Virtual Temperature, Atmospheric Pressure, Air Density |
| Brand | Lufft |
|---|---|
| Origin | Imported |
| Model | Lufft Ventus-UMB |
| Instrument Type | Ultrasonic Anemometer |
| Resolution | 0.1 m/s |
| Measurement Range | 0–90 m/s |
| Accuracy | ±0.2 m/s or ±2% RMS (0–65 m/s), whichever is greater |
| Operating Temperature | −40 °C to +60 °C (with integrated heater) |
| Relative Humidity Range | 0–100% RH |
| Protection Rating | IP68 |
| Brand | Lufft |
|---|---|
| Origin | Germany |
| Model | VENTUS-X-UMB |
| Heating Function | Integrated PTC-based anti-icing system |
| Measurement Principle | Time-of-flight ultrasonic anemometry |
| Output Protocols | SDI-12, Modbus RTU, ASCII, CAN bus (configurable) |
| Environmental Certification | IP66, EN 60950-1, EN 61000-6-2/-6-3, IEC 60068-2-30 (damp heat), IEC 60068-2-14 (thermal cycling), IEC 60068-2-6 (vibration), IEC 60068-2-52 (salt mist), IEC 60068-2-31 (ice accretion test) |
| Operating Temperature Range | –40 °C to +70 °C (with active heating) |
| Wind Speed Range | 0–60 m/s |
| Wind Direction Range | 0–360° |
| Resolution | 0.1 m/s (wind speed), 1° (wind direction) |
| Accuracy | ±0.2 m/s (wind speed), ±2° (wind direction) |
| Power Supply | 12–30 V DC |
| Power Consumption | <1.5 W (standby), <4.5 W (heating active) |
| Brand | Lufft |
|---|---|
| Origin | Germany |
| Model | WS100-UMB |
| Measurement Principle | 24 GHz Doppler radar-based particle detection |
| Power Supply | DC 12–36 V (solar-compatible) |
| Operating Temperature | −40 °C to +70 °C |
| Heating Function | Integrated radar dome heater |
| Communication Protocols | Modbus RTU, SDI-12, CAN, ASCII, MQTT (optional) |
| IP Rating | IP66 |
| Maintenance | No moving parts, maintenance-free design |
| Compliance | CE, RoHS, EN 61326-1 (EMC), EN 61000-6-2/6-4 |
| Brand | Lufft |
|---|---|
| Origin | Germany |
| Model | WS200-UMB |
| Measurement Principle | Ultrasonic time-of-flight anemometry |
| Wind Speed Range | 0–60 m/s |
| Wind Direction Range | 0–360° |
| Power Supply | 12–24 VDC, solar-compatible |
| Operating Temperature | −40 to +70 °C |
| IP Rating | IP66 |
| Communication Protocols | SDI-12, RS-232/485, Modbus RTU, CAN bus, MQTT (optional) |
| Integrated Electronic Compass | Yes |
| Heating Function | Integrated ultrasonic transducer heating |
| Output Parameters | Wind speed (m/s), wind direction (°), wind quality index (WQI), status diagnostics |
| External Sensor Support | Rain gauge, temperature/humidity probe, barometric pressure sensor |
| Compliance | CE, RoHS, WMO Guide to Instruments and Methods of Observation (CIMO) |
| Brand | Lufft |
|---|---|
| Model | WS300-UMB |
| Measurement Parameters | Air Temperature, Relative Humidity, Atmospheric Pressure, Dew Point Temperature |
| Sensor Principles | NTC Thermistor (Temperature), Capacitive Polymer (Humidity), MEMS Barometric Sensor (Pressure) |
| Power Supply | Low-power design, compatible with solar power systems |
| Enclosure | Compact, integrated, IP66-rated housing |
| Fan-Assisted Aspiration | Integrated active ventilation fan for radiation-shielded temperature/humidity measurement |
| Communication Interfaces | RS-232, RS-485, SDI-12, Modbus RTU, CAN bus, UMB-ASCII |
| Expandability | Supports external rain gauge, PT100/PT1000 temperature probes, and third-party analog/digital sensors |
| Compliance | CE, RoHS, WEEE, EN 61326-1 (EMC), EN 61000-6-2/-6-4 |
| Operating Temperature Range | –40 °C to +70 °C |
| Storage Temperature Range | –40 °C to +70 °C |
| Relative Humidity Range | 0–100 % RH (non-condensing) |
| Pressure Range | 500–1100 hPa |
| Typical Power Consumption | <1.5 W (standby), <3.2 W (fan active) |
| Brand | Lufft |
|---|---|
| Origin | Germany |
| Model | WS500-UMB |
| Measurement Principles | Ultrasonic (wind speed & direction), NTC thermistor (temperature), Capacitive polymer (relative humidity), MEMS capacitive (barometric pressure) |
| Wind Speed Range | 0–60 m/s |
| Wind Speed Accuracy | ±0.3 m/s or ±3% (0–35 m/s) |
| Wind Direction Range | 0–359.9° |
| Wind Direction Accuracy | ±3° |
| Temperature Range | −50 to +60 °C |
| Temperature Accuracy | ±0.2 °C (−20 to +50 °C), ±0.5 °C (outside range) |
| Relative Humidity Range | 0–100 %RH |
| RH Accuracy | ±2 %RH |
| Barometric Pressure Range | 300–1200 hPa |
| Pressure Accuracy | ±1.5 hPa |
| Power Supply | 24 VDC ±10%, <4 VA (unheated), 10 W max with heater |
| Output Interface | RS-485, 2-wire, half-duplex |
| Operating Temperature | −50 to +60 °C |
| Enclosure Material | Anodized aluminum |
| Weight | 1.3 kg |
| Dimensions (H × Ø) | 290 mm × 150 mm |
| Color | White powder-coated finish |
| Protocol | Lufft UMB protocol (binary/ASCII over RS-485) |
| Brand | Lufft |
|---|---|
| Model | WS501-UMB |
| Measurement Principle | Ultrasonic time-of-flight (wind speed & direction), NTC thermistor (temperature), capacitive humidity sensor (relative humidity), MEMS capacitive barometer (atmospheric pressure), thermopile pyranometer (global solar radiation) |
| Power Supply | DC 12–30 V, solar-compatible |
| Communication Protocols | SDI-12, Modbus RTU (RS-485), CAN bus, UMB-ASCII (native), optional MQTT/HTTP via gateway |
| Wind Measurement Range | 0–60 m/s (±0.1 m/s @ <5 m/s), 0–360° (±2°) |
| Temperature Range | –40 to +70 °C (±0.2 °C) |
| Relative Humidity Range | 0–100 %RH (±2 %RH) |
| Pressure Range | 500–1100 hPa (±0.5 hPa) |
| Radiation Range | 0–2000 W/m² (±5 %) |
| Operating Temperature | –40 to +70 °C |
| IP Rating | IP66 |
| Heating | Integrated ultrasonic transducer heating (–40 to +5 °C activation) |
| Fan-Assisted Aspiration | Yes, continuous low-power fan for radiation and humidity sensor thermal stabilization |
| Sensor Mounting | Integrated, single-mast mounting |
| Data Output | Real-time analog/digital, quality flags per parameter |
| Compliance | CE, RoHS, EN 61326-1 (EMC), EN 61000-6-2/-4, WMO Guide to Instruments and Methods of Observation (CIMO) Class II recommended |
| Brand | Lufft |
|---|---|
| Origin | Germany |
| Model | WS502-UMB |
| Measurement Principles | Ultrasonic time-of-flight (wind speed/direction), NTC thermistor (air temperature), capacitive hygrometer (relative humidity), MEMS barometric pressure sensor, photodiode-based pyranometer (global solar radiation) |
| Power Supply | 12–30 V DC, solar-compatible |
| Communication Protocols | Modbus RTU/ASCII, SDI-12, CAN bus, UMB-protocol (native), optional MQTT/HTTP via gateway |
| Environmental Rating | IP66 |
| Operating Temperature Range | –40 °C to +70 °C |
| Wind Measurement Range | 0–75 m/s (0.01 m/s resolution), Direction: 0–360° (0.1° resolution) |
| Temperature Range | –40 to +70 °C (±0.2 °C accuracy) |
| Relative Humidity Range | 0–100 %RH (±2 %RH typical) |
| Pressure Range | 500–1100 hPa (±0.5 hPa) |
| Radiation Range | 0–2000 W/m² (±5 % uncertainty) |
| Integrated Fan Aspiration | Yes |
| Heating Function | Yes (ultrasonic transducers) |
| Data Output | Real-time wind quality index (e.g., signal-to-noise ratio, data validity flags), configurable sampling interval (1 s to 10 min) |
| External Sensor Support | Rain gauge (pulse input), Pt100/Pt1000 temperature probes, analog 4–20 mA inputs |
| Brand | Lufft |
|---|---|
| Model | WS601-UMB |
| Measurement Parameters | Wind Speed, Wind Direction, Air Temperature, Relative Humidity, Atmospheric Pressure, Precipitation |
| Principle | Ultrasonic Time-of-Flight (Wind), NTC Thermistor (Temperature), Capacitive Polymer Sensor (Humidity), MEMS Capacitive Barometer (Pressure), Tipping-Bucket Rain Gauge (Precipitation) |
| Power Supply | Low-power design, solar-compatible |
| Enclosure | Compact all-in-one housing with active ventilation fan and heated ultrasonic transducers |
| Output | Wind quality indicator, integrated electronic compass, optional external temperature probe support |
| Communication Protocols | Modbus RTU/ASCII, SDI-12, CAN bus, ASCII serial, optional MQTT/HTTP for IoT integration |
| Compliance | IP66 rated enclosure, CE marked, RoHS compliant |
| Brand | LUMEX |
|---|---|
| Origin | Russia |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AKMC-1 |
| Price Range | USD 13,500 – 40,500 |
| Measurement Principle | Potentiometric Titration |
| Detection Range | 0.25–250 ppm (as CaCO₃) |
| Sampling Frequency | 1–4 times/hour |
| Operating Temperature | +10 to +35 °C |
| Relative Humidity (at +25 °C) | <80% |
| Sample Pressure | 0.1–10 atm |
| Sample Temperature | +5 to +40 °C |
| Power Supply | 110/220 VAC, 50/60 Hz |
| Power Consumption | 100 W |
| Dimensions | 300 × 400 × 150 mm |
| Weight | 20 kg |
| Brand | LUMEX |
|---|---|
| Origin | Canada |
| Model | BA-15 |
| Detection Principle | Atomic Absorption Spectrometry with High-Frequency Zeeman Background Correction |
| Measurement Range | 0.1 ng/m³ – 10,000 mg/m³ |
| Response Time | 1 sec (real-time) – 5 min (integrated mode) |
| Zero Drift Compensation | Automatic |
| Sample Flow Rate | 7–10 L/min |
| Dimensions | 470 × 110 × 210 mm |
| Weight | 7 kg (15.4 lb) |
| Power Supply | 90–240 VAC, 50/60 Hz or 12 VDC |
| Power Consumption | 40 W |
| Brand | LUMEX |
|---|---|
| Origin | Russia |
| Model | CRAB |
| Type | Online Oil Film Monitoring System |
| Measurement Range | 0–111 mg/L (as mineral oil, typical calibration) |
| Detection Limit | 0.2 mg/L |
| Accuracy | ±1 mg/L |
| Resolution | 0.1 mg/L |
| Measurement Frequency | 1 Hz |
| Minimum Detectable Oil Film Thickness | ≥0.5 µm |
| Maximum Sensor-to-Water Distance | 25 m |
| Maximum Communication Distance (RS485) | 300 m |
| Operating Temperature | −10 to +50 °C |
| Relative Humidity | Up to 100% |
| Power Supply | 187–242 VAC, 50 Hz |
| Power Consumption | 20 W |
| Dimensions | 160 × 160 × 110 mm |
| Weight | 2 kg |
| Optical Field Tilt Tolerance | ±20° |
| Communication Interfaces | RS232, RS485 |
| Alarm Output | Relay + Visual/Audible Alert |
| Mounting Options | Fixed, pendant, angled, or UAV-integrated |
| Brand | LUMEX |
|---|---|
| Origin | Canada |
| Model | FLUORAT-02 |
| Instrument Type | Portable/Handheld Water Quality Analyzer |
| Detection Methods | Fluorometry, Photometry, Chemiluminescence |
| Measured Parameters | Oil in Water, Volatile Phenols, Anionic Surfactants, COD, Turbidity, Cyanide, Uranium, Vanadium, Molybdenum, Nickel, Manganese, Chromium |
| Spectral Range | 250–900 nm |
| Cuvette Pathlengths | 10, 20, and 40 mm |
| Power Supply | 200–240 VAC, 50 Hz |
| Dimensions | 305 × 320 × 110 mm |
| Weight | 6.5 kg |
| Power Consumption | 36 W |
| Brand | LUMEX |
|---|---|
| Origin | Russia |
| Model | Fluorat-02-5M |
| Instrument Type | Portable |
| Measurement Principle | UV Spectrophotometry & Fluorescence Detection |
| Detection Limit | 0.2 mg/L |
| Accuracy | ±1% |
| Resolution | 0.01 mg/L |
| Measurement Frequency | 2 samples/min |
| Spectral Range | 250–900 nm |
| Cuvette Pathlengths | 10, 20, and 40 mm |
| Power Supply | 200–240 VAC, 50 Hz |
| Dimensions | 305 × 320 × 110 mm |
| Weight | 6.5 kg |
| Power Consumption | 36 W |
| Brand | LUMEX |
|---|---|
| Origin | Russia |
| Model | Fluorat-AE-2 |
| Instrument Type | Online |
| Measurement Principle | UV Fluorescence with Patented Signal Separation Technology |
| Measurement Range | 0.001–500 mg/L |
| Detection Limit | 0.01 mg/L |
| Accuracy | <2% |
| Resolution | 0.1 mg/L |
| Measurement Frequency | 8 samples/hour |
| Sample Input | Up to 10 parallel aqueous streams |
| Power Supply | 187–242 VAC, 50 ±1 Hz / 12 VDC |
| Power Consumption | 100 W |
| Dimensions | 500 × 660 × 200 mm |
| Weight | 50 kg |
| Brand | LUMEX |
|---|---|
| Model | FLUORAT® AA-2 |
| Origin | Russia |
| Detection Range | 0.04–2 mg/L Al |
| Operating Temperature | +5 to +50 °C |
| Sample Flow Pressure | 0.1–10 atm |
| Cycle Time | 10–30 min |
| Output Interfaces | RS-485, RS-232, 4–20 mA (0–20 mA) |
| Power Supply | 187–242 V, 50 Hz ±1%, 12 V DC |
| Power Consumption | 100 W |
| Dimensions | 600 × 600 × 250 mm |
| Weight | ≤ 50 kg |
| MTBF | ≥ 10,000 h |
| IP Rating | Dust-protected and splash-resistant |
| Compliance | PND F 14.1:2.4.181-02, PND F 14.1:4.1.1255-03 |
| Brand | LUMEX |
|---|---|
| Origin | USA |
| Model | IRM-915 |
| Detection Principle | Zeeman-effect Background-Corrected Cold Vapor Atomic Absorption Spectrometry (CVAAS) with High-Temperature Dry Catalytic Conversion |
| Measurement Range | 0.05–1000 µg/m³ (wet basis, HgT and Hg⁰) |
| Zero Drift | ±2.5% |
| Precision | ±2.5% |
| Accuracy | ±5% |
| Conversion Temperature | 700–750 °C |
| Dilution Ratio | Up to 1:100 |
| Sample Flow | Heated probe + heated filter + dilution/conversion module |
| Power Requirement | 220 V, 1000 W |
| Compressed Air | 15–20 L/min at 80 psig |
| Data Output | Real-time acquisition |
| System Weight | 67 kg |
| Brand | LUMEX |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | OLM30B Sampler |
| Sampling Flow Rate | 1 L/min |
| Flow Accuracy | ±1% of full scale |
| Sampling Temperature | Up to 150 °C |
| Sample Target | Elemental and Oxidized Mercury (Hg⁰, Hg²⁺) |
| Flow Resolution | 0.01 L/min |
| Repeatability | ±1% FS |
| Max Flow Rate | 2 L/min |
| Power Supply | 110/220 V AC |
| Power Consumption | 500 W |
| Operating Temperature Range | –10 °C to 50 °C |
| Weight | Air Pump Unit 6.8 kg, Probe 14 kg |
| Compliance | EPA Method 30B, 40 CFR Part 60, ASTM D6784-22 |
| Brand | LUMEX |
|---|---|
| Origin | USA |
| Model | OLM915J |
| Detection Principle | High-Temperature Catalytic Conversion + Zeeman-Background-Corrected Atomic Absorption Spectrometry (AAS) |
| Measurement Range | 0.1–100 µg/m³ |
| Response Time | ≤30 seconds per reading |
| Compliance | EPA Method PS 12A (Level 3 Certified) |
| Sample Handling | Hot-wet extraction with heated sampling probe (10–50 ft customizable), Ni-based alloy filter/dilution module, dry catalytic conversion at 750 °C |
| Enclosure Rating | NEMA 4X |
| Operating Ambient Temperature | –10 to 50 °C |
| Power Requirement | 110/220 VAC, 2000 W |
| Compressed Air Supply | Dry, dew point ≤ –40 °C |
| Calibration | Integrated elemental Hg vapor generator, fully automated, no external standards required |
| Data Output | Real-time Ethernet (Modbus TCP/IP, OPC UA), Excel export via embedded industrial PC, ESC8832-compatible |
| Brand | LUMEX |
|---|---|
| Model | RA-915WM |
| Principle | High-Temperature Thermal Decomposition Coupled with Zeeman Atomic Absorption Detection |
| Detection Limit | 0.3 µg/L |
| Measurement Range | 0–200 µg/L |
| Analysis Frequency | Once every 0.5–3 hours |
| Calibration | Fully Automatic |
| Baseline Verification | Fully Automatic |
| Max. Dissolved Solids Tolerance | 1000 mg/L |
| Communication Interfaces | RS-232/485, LAN, Isolated 4–20 mA |
| Protocols | Modbus, GESYTEC |
| Output Relays | Open/Closed |
| Operating Temperature | 5–40 °C |
| Atmospheric Pressure Range | 84–106.7 kPa |
| Relative Humidity | <98% at +35 °C |
| Power Supply | 110/240 VAC, 50/60 Hz |
| Dimensions (L×W×H) | 1000 × 400 × 2000 mm |
| Origin | Italy |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LUPIN 5401 |
| Instrument Category | Ambient Dose Equivalent Rate Meter |
| Instrument Type | Laboratory-Grade |
| Detection Medium | Gas-Filled Proportional Counter |
| Detector Technology | He-3 or BF₃ Thermal-to-Fast Neutron Converter |
| Energy Range | 0.025 eV – 5 GeV |
| Sensitivity | 1 cps per µSv/h (He-3), 0.6 cps per µSv/h (BF₃) |
| Dose Equivalent Rate Range | 10 nSv/h – 100 mSv/h |
| Pulse Field Tolerance | ≤10% deviation at 2 µSv incident dose per pulse |
| Compliance | IEC 61000-4-3 (EMC), IEC 60846-2:2014 (Radiation Protection Instrumentation – Part 2: Ambient and Directional Dose Equivalent Meters for Neutrons) |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | LX501 |
| Pricing | Available Upon Request |
| Power Supply | 220 VAC / 12.6 VDC, 1 A adapter |
| Battery | 12 V / 3 Ah rechargeable Li-ion (up to 23 h continuous operation) |
| Detector | Φ30 mm Passivated Implanted Planar Silicon (PIPS) semiconductor detector |
| Display | 160 × 160 dot-matrix LCD with white backlight |
| Radon Concentration Range | 0–99,999 Bq·m⁻³ |
| Surface Exhalation Rate Range | 0.01–10,000 mBq·m⁻²·s⁻¹ |
| Measurement Uncertainty | ≤5% (at radon concentrations ≥200 Bq·m⁻³) |
| Sensitivity | 55 cpm per Bq·m⁻³ |
| Sampling Interval Options | 15 min or 60 min |
| Data Interface | RS-232 (9-pin D-sub), compatible with thermal microprinters |
| Memory | EEPROM non-volatile storage |
| Operating Environment | 0–40 °C, 0–90% RH (non-condensing) |
| Dimensions & Weight | 250 × 140 × 270 mm (W×H×D), 4.0 kg |
| Brand | LINGXI Optoelectronics |
|---|---|
| Model | LXEC-210 |
| Measurement Principle | Non-Dispersive Infrared (NDIR) Spectroscopy |
| Target Gases | CO₂, H₂O |
| Origin | Zhejiang, China |
| Gas Detection Configuration | Open-path, in-situ |
| Power Consumption | Low-power design, no pump required |
| Compliance Context | Designed for field-deployable eddy covariance (EC) flux measurements per AmeriFlux/ICOS protocols |
| Sample Interface | Direct atmospheric sampling, no inlet tubing or sample cell |
| Brand | LINGXI Optoelectronics |
|---|---|
| Origin | Zhejiang, China |
| Model | LXEC-210C |
| Measurement Principle | Non-Dispersive Infrared (NDIR) Spectroscopy |
| Measured Gases | CO₂ and H₂O |
| Gas Path Configuration | Closed-Path |
| Compliance Context | Designed for long-term eddy covariance flux measurements per AmeriFlux/ICOS protocols |
| Data Integrity Features | Automated zero calibration, temperature-stabilized optical bench, high-frequency sampling (up to 20 Hz) |
| Environmental Robustness | IP65-rated enclosure, -25 °C to +50 °C operating range, condensation-resistant sample line heating |
| Brand | ZHUOCHI |
|---|---|
| Origin | Zhejiang, China |
| Model | SK3-2.5-13 Complete System |
| Type | Laboratory Benchtop Tube Furnace |
| Temperature Range | 100–1300 °C |
| Temperature Stability | ±1 °C |
| Display Resolution | 1 °C |
| Furnace Chamber Dimensions | φ22 mm × 380 mm |
| Heating Zone Length | 280 mm |
| Max Ramp Rate | ≤50 °C/min (adjustable) |
| Power Rating | 2.5 kW |
| Supply | 220 V, 50 Hz |
| Weight | ~22 kg |
| Control System | LTDE Programmable PID Controller with SSR Output, Dual-Stage Over-Temperature Protection |
| Thermal Insulation | High-Efficiency Ceramic Fiber Blanket |
| Heating Element | Oxidation-Resistant High-Temperature Resistance Wire |
| Thermocouple Type | S-Type (Platinum-Rhodium/Platinum) |
| Brand | Zhuochi |
|---|---|
| Origin | Zhejiang, China |
| Model | SK3-2.5-13 |
| Type | Laboratory Benchtop Tube Furnace System |
| Temperature Range | 100–1300 °C |
| Temperature Uniformity | ±1 °C |
| Heating Zone Length | 280 mm |
| Tube ID Compatibility | φ22 mm |
| Max Ramp Rate | 50 °C/min (adjustable) |
| Power Rating | 2.5 kW |
| Supply | 220 V, 50 Hz |
| Weight | ~22 kg |
| Compliance | Designed for LYT 1255–1999 (Forestry Industry Standard of the People’s Republic of China: Determination of Total Sulfur in Soils by High-Temperature Combustion–Infrared Absorption Method) |
| Brand | Zhuochi |
|---|---|
| Origin | Zhejiang, China |
| Type | Laboratory Benchtop Combustion-Based Total Sulfur Analyzer |
| Model | LYT 1255-1999 compliant SK3-2.5-13 |
| Temperature Range | 100–1300 °C |
| Temperature Stability | ±1 °C |
| Furnace Tube ID | φ22 mm |
| Heating Zone Length | 280 mm |
| Max Ramp Rate | ≤50 °C/min (adjustable) |
| Power | 2.5 kW |
| Voltage/Frequency | 220 V, 50 Hz |