Environmental Monitoring Instruments
Filter
Showing 5551–5580 of 9112 results
| Origin | Austria |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | maMoS-100/200 |
| Price Range | USD 14,000 – 42,000 |
| Instrument Type | Continuous Emission Monitoring System (CEMS) |
| Indication Error | ≤ ±5% FS |
| Repeatability | ≤ 2% RSD |
| Response Time (T90) | ≤ 45 s |
| Stability | ≤ 5% FS drift over 1 h |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Manual Environmental Soil Sampling Kit |
| Price | Available Upon Request |
| Origin | Germany |
|---|---|
| Type | Imported Instrument |
| Model | MAC100ECO |
| Manufacturer Role | Authorized Distributor |
| Pricing | Available Upon Request |
| Brand | Merck |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | MAS-100 NT |
| Sampling Principle | Impaction-based Active Air Sampling |
| Flow Rate Range | 1–2000 L/min |
| Flow Measurement Accuracy | ±2.5% at 100 L/min |
| Total Operating Time | Approx. 5.5 h on full battery charge |
| Storage Temperature | −10°C to +50°C |
| Operating Temperature | 0°C to +40°C |
| Operating Relative Humidity | ≤80% RH (up to +31°C), linearly decreasing to ≤50% RH at +40°C, non-condensing |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model Variants | SP5 A / SP5 B / SP5 S / SP5 Zone2 |
| Instrument Class | Automated Online Water Sampler |
| Sampling Method | Vacuum-Driven Enrichment with Dual-Stage Filtration |
| Instrument Type | Online Enrichment Water Sampler |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ESP |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MCA03 |
| Price Range | USD 42,000–70,000 |
| Instrument Type | Extractive In-Situ Flue Gas Analyzer |
| Measurement Accuracy | ≤ ±2% of Full Scale |
| Repeatability | Not Specified |
| Response Time | ≤10 s |
| Stability | Not Specified |
| Brand | MCQ |
|---|---|
| Origin | Italy |
| Model | GB 100 |
| Flow Range (per channel) | 0–500 mL/min (standard), 0–200 mL/min (optional) |
| Accuracy | ±1.0% of setpoint (5–100% FS), ±0.2% of full scale (<5% FS) |
| Repeatability | ±0.1% of reading |
| Response Time | 50 ms per channel |
| Total Mixed Flow | Up to 1.5 L/min |
| Channels | 3 inlet, 1 outlet |
| Operating Pressure | ≤25 psi |
| Power Supply | 16–36 VDC, min. 1.5 A |
| Operating Temperature | 0–50 °C |
| Gas Compatibility | N₂, O₂, CO₂, CH₄, Air, NO, CO, Ar, C₂H₄, C₂H₆, C₃H₈, C₄H₁₀ (H₂ not supported) |
| Certifications | CE, TÜV, cTÜVus |
| Interface | USB PC connection, LED front-panel display |
| Software | Dedicated gas mixing control software (Windows-based), no third-party API support for GB100 variant |
| Brand | MCQ |
|---|---|
| Origin | Italy |
| Model | GB100PLUS |
| Input Channels | 3/4/6 (configurable) |
| Output Channels | 1 |
| Flow Range per Channel | 0–500 mL/min (standard) |
| optional ranges | 0–200 / 0–5,000 / 0–15,000 mL/min |
| Dilution Ratio | 1:1 to 1:1000 |
| Gas Compatibility | N₂, O₂, CO₂, CH₄, Air, NO, CO, Ar, C₂H₄, C₂H₆, SF₆, C₃H₈, C₄H₁₀, H₂, He, DME (C₂H₆O), N₂O, SO₂, and other gases upon consultation |
| Third-Party Software Integration | Yes (via RS-232, RS-485, or Ethernet with Modbus RTU/TCP protocol) |
| Compliance | CE-marked |
| Brand | MCQ |
|---|---|
| Origin | Italy |
| Model | GB15K |
| Inlet Channels | 3 |
| Outlet Channels | 1 |
| Flow Range per Channel | 0–15,000 mL/min |
| Dilution Ratio | 1–1000 |
| Third-Party Software Communication | Yes |
| Compatible Gases | N₂, O₂, CO₂, CH₄, Air, NO, CO, Ar, C₂H₄, C₂H₆, SF₆, C₃H₈, C₄H₁₀, H₂, He, DME (C₂H₆O), N₂O, SO₂ (custom gases available upon consultation) |
| Brand | MCQ |
|---|---|
| Model | GB3000 |
| Origin | Italy |
| Configuration | 3-inlet / 1-outlet |
| Max Flow per Channel | 0–5000 mL/min |
| Dilution Ratio Range | 1:1 to 1:1000 |
| Gas Compatibility | N₂, O₂, CO₂, CH₄, Air, NO, CO, Ar, C₂H₄, C₂H₆, SF₆, C₃H₈, C₄H₁₀, H₂, He, DME (C₂H₆O), N₂O, SO₂, etc. |
| Third-Party Software Integration | Yes |
| Regulatory Compliance | Designed for ISO/IEC 17025-compliant calibration labs and EPA/EN-certified environmental testing environments |
| Brand | MCQ |
|---|---|
| Origin | Italy |
| Model | GB4000 |
| Inlet Channels | 4 |
| Outlet Channels | 1 |
| Flow Range per Channel | 0–5000 mL/min |
| Dilution Ratio | 1:1 to 1:1000 |
| Gas Compatibility | N₂, O₂, CO₂, CH₄, Air, NO, CO, Ar, C₂H₄, C₂H₆, SF₆, C₃H₈, C₄H₁₀, H₂, He, DME (C₂H₆O), N₂O, SO₂, and other custom gases upon request |
| Third-Party Software Integration | Yes |
| Certification | CE-marked, compliant with ISO/IEC 17025 traceability requirements for gas standard generation |
| Brand | MCQ |
|---|---|
| Origin | Italy |
| Model | GB6000 |
| Input Channels | 6 |
| Output Channels | 1 |
| Flow Range per Channel | 0–5000 mL/min |
| Dilution Ratio | 1:1 to 1:1000 |
| Gas Compatibility | N₂, O₂, CO₂, CH₄, Air, NO, CO, Ar, C₂H₄, C₂H₆, SF₆, C₃H₈, C₄H₁₀, H₂, He, DME (C₂H₆O), N₂O, SO₂, and other custom gases upon consultation |
| Third-Party Software Integration | Yes |
| Certification Status | CE-marked, compliant with ISO/IEC 17025 traceability requirements for gas standard generation |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MDO-2 |
| Instrument Type | Portable |
| Measurement Range | 0–25 mg/L |
| Accuracy | ±1% of reading or ±0.02 mg/L (whichever is greater) |
| Resolution | 0.01 mg/L (≤4.00 mg/L), 0.1 mg/L (>4.00 mg/L) |
| Stability | ±0.01 mg/L |
| Repeatability | ±0.01 mg/L |
| Drift | <1% per year |
| Temperature Range (Sample) | 0–60°C |
| Response Time (t₉₅) | <60 s |
| Operating Environment | −20 to +70°C, 0–100% RH |
| IP Rating | IP66 |
| Sensor Cable Length | 6.0 m |
| Maximum Pressure Rating | 100 PSI |
| Sensor Lifetime | 7–10 years |
| Display | Backlit graphical LCD with UV-resistant housing and adjustable contrast |
| Data Storage | 50 measurement records |
| Interface | RS-232 serial output |
| Diagnostic Function | Built-in probe self-test |
| Power | Rechargeable battery |
| Brand | Medcom |
|---|---|
| Origin | USA |
| Model | CRM-100 |
| Detector Type | Halogen-quenched Geiger-Müller tube with mica end-window (45 mm diameter, 1.5–2.0 mg/cm² density) |
| Radiation Types Detected | Alpha, Beta, Gamma, and X-ray |
| Energy Range | 20 keV – 3 MeV |
| Dose Rate Range | 0.001–110.0 mR/h or 0.01–1100 µSv/h |
| Count Rate Range | 0–3,500 CPS / 0–350,000 CPM |
| Total Count Capacity | Up to 9,999,000 counts |
| Timer Range | Up to 40 hours |
| Sensitivity | ≥1,000 CPM per mR/h (referenced to Cs-137) |
| Accuracy | ±10% typical, ±15% maximum (mR/h and µSv/h modes) |
| Audio Feedback | Click-per-count (user-muteable) |
| Display | 4-digit LCD with mode indicators |
| Output Interface | 3.5 mm mono jack (CMOS-compatible TTL pulse output) |
| Input Interface | 2.5 mm calibration input port |
| Power | One 9 V alkaline battery (typical life: 2,160 hours) |
| Dimensions | 150 × 80 × 30 mm |
| Weight | 225 g (including battery) |
| Certifications | CE, RoHS, WEEE, ISO 9001:2001 & ISO 14001 |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Inspector Alert™ V2 |
| Detection Principle | Halogen-quenched Geiger-Müller tube with mica window (1.75" diameter, 1.5–2.0 mg/cm² density) |
| Radiation Types Detected | Alpha, Beta, Gamma, and X-ray |
| Dose Rate Range | 0.01–1100 µSv/hr |
| Exposure Rate Range | 0.001–110 mR/hr |
| Count Rate | 0–350,000 CPM / 0–5,000 CPS |
| Total Count Capacity | 1–9,999,000 counts |
| Alarm Thresholds | Adjustable for µSv/hr (0–500), mR/hr (0–50), CPM (0–160,000) |
| Display | 4-digit LCD with mode indicators |
| Update Interval | 3-second rolling average (adaptive to radiation level) |
| Power | Single AA alkaline battery (≥3500 hr at background) |
| Dimensions | 150 × 80 × 30 mm |
| Weight | 323 g (incl. battery) |
| Operating Temperature | –20 °C to +50 °C |
| Certifications | CE (EN 55011:1998+A2, EN 61326:2006, EN 61000-4-2:1995, EN 61000-4-3:1997), RoHS, WEEE, ISO 9001:2001, ISO 14001 |
| Brand | Medcom |
|---|---|
| Origin | USA |
| Model | Radalert100 |
| Detection Principle | Halogen-quenched Geiger-Müller tube |
| Energy Range | 20 keV – 3 MeV |
| Dose Rate Range (mR/hr) | 0.001 – 110.0 |
| Dose Rate Range (µSv/hr) | 0.01 – 1100 |
| Count Rate (CPM) | 0 – 350,000 |
| Count Rate (CPS) | 0 – 3,500 |
| Total Count Capacity | 1 – 9,999,000 |
| Calibration Source | ¹³⁷Cs (γ) |
| Sensitivity | 1,000 CPM per mR/hr (referenced to ¹³⁷Cs) |
| Accuracy | ±10% typical, ±15% maximum |
| Display | 4-digit LCD with mode indicators |
| Audio/Visual Alert | User-adjustable threshold, LED flash per count |
| Interface | 3.5 mm output jack (0–9 V, 1 kΩ impedance), 2.5 mm calibration input |
| Power | 9 V alkaline battery (≥700 h typical life) |
| Dimensions | 150 × 80 × 30 mm |
| Weight | 323 g (including battery) |
| Compliance | CE-marked |
| Brand | Merck |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Calcium Ion Titration Test Kit |
| Pricing | Upon Request |
| Brand | Merck Millipore |
|---|---|
| Origin | Germany |
| Product Type | Pre-calibrated Colorimetric Test Kits (AquaQuant®, MicroQuant®, Aquamerck®) |
| Parameter Range | Total Hardness, Free Chlorine, Alkalinity, Phosphate, Ammonia-N, Nitrate, Nitrite, Iron, Copper, Calcium, Magnesium, Dissolved Oxygen, Silica, Sulfate, Cyanide, Ozone, Chlorine Dioxide, and 30+ additional parameters |
| Compliance | ISO 9001-certified manufacturing |
| Brand | Merck |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Merckoquant |
| Instrument Type | Laboratory Water Quality Analyzer |
| Target Analytes | Ammonia-Nitrogen, Nitrate, Phosphate |
| Brand | Merck |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | MERCK |
| Instrument Type | Portable / Handheld Water Quality Analyzer |
| Analytes | Cyanide, Arsenic, Heavy Metals (Cu, Ni, Cr⁶⁺, Zn, Fe, Mn, Pb, Cd, etc.) |
| Detection Principle | Colorimetric Semi-Quantitative Visual Comparison |
| Compliance | ASTM D3370, ISO 9562, ISO 10530, EN ISO 11732, US EPA Method 9010B (Cyanide), US EPA Method 7196A (Hexavalent Chromium), DIN 38405-27 |
| Brand | Merck Millipore |
|---|---|
| Origin | Germany |
| Product Type | Multi-ion Colorimetric Test Strips |
| Parameter Range | H₂O₂/Peroxides, Total Hardness, pH, and 30+ Additional Analytes |
| Compliance | Designed for ISO/IEC 17025-aligned field testing and routine QC screening |
| Brand | Merck Millipore |
|---|---|
| Origin | Germany |
| Model | Prove |
| Instrument Type | Laboratory Water Quality Analyzer |
| Detection Capacity | 180 water quality parameters |
| Wavelength Range | 190–1,100 nm (UV-Vis) |
| Light Sources | Tungsten-halogen lamp (Prove100), Pulsed xenon lamp (Prove300/Prove600) |
| Spectral Bandwidth | 4 nm (Prove100), 1.8 nm (Prove300/Prove600) |
| Cuvette Compatibility | 16 mm round tubes |
| Display | Resistive touchscreen (Prove100/300), P-cap glass capacitive touchscreen (Prove600) |
| Language Support | 28 built-in languages |
| AQA Levels | AQA 1, AQA 2, pipette accuracy verification |
| Barcode Integration | Full QR-code support for reagent lot, expiry, calibration data, and method traceability |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | Merck Millipore |
|---|---|
| Origin | Germany |
| Model | TR320 / TR420 / TR620 |
| Display | LCD with real-time temperature & timer |
| Capacity | TR320: 12 × 16 mm tubes |
| TR420/TR620 | 24 × 16 mm tubes (TR620: dual independent 12-position blocks) |
| Temperature Range | TR320: 100–148 °C |
| TR420/TR620 | RT–170 °C |
| Temperature Accuracy | ±1.0 °C |
| Inter-zone Uniformity | ±1.5 °C vs setpoint |
| Built-in Programs | 7 preconfigured (e.g., 148 °C/20 min for COD, 120 °C/60 min for TOC, 100 °C/60 min for Ag/AOX) |
| Custom Programs | TR420/TR620 support up to 8 user-defined protocols (0–180 min, 1 °C resolution) |
| Power Supply | 115–230 V~, 50/60 Hz |
| Dimensions (H×W×D) | 180 × 256 × 307 mm |
| Weight | TR320: 2.85 kg |
| TR420/TR620 | 3.6 kg |
| Optional Accessories | External Pt100 temperature probe, PC interface cable for AQA documentation |
| Brand | Millipore |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Amicon Stirred Ultrafiltration Cell |
| Pricing | Available Upon Request |
| Brand | Merck Millipore |
|---|---|
| Type | Stirred Cell |
| Model | Amicon® Ultrafiltration Cell (11 mL capacity) |
| Max Operating Pressure | 100 psi (6.9 bar) |
| Effective Membrane Area | 4.2 cm² |
| Sample Volume Range | 0.5–11 mL |
| Material | Anodized Aluminum Body, PTFE Seals, Stainless Steel Stir Bar |
| Compatibility | Sterilizable (Autoclavable at 121°C), Solvent-Resistant Options Available |
| Compliance | Meets ASTM D4187 and ISO 15713 for membrane performance evaluation |
| Brand | Merck |
|---|---|
| Origin | USA |
| Product Line | MQuant® Ammonia-N Test Strips |
| Format | Dip-and-read colorimetric test strips |
| Measurement Range | 0.1–5.0 mg/L NH₃-N (typical for MQuant® Ammonia-N, per Merck technical documentation) |
| Detection Principle | Indophenol blue method (NH₃ + phenol + hypochlorite → blue chromophore) |
| Compliance | Designed to support ISO 7150-1, ASTM D1426, and EPA Method 350.1 screening protocols |
| Package Options | 50 or 100 tests per vial |
| Shelf Life | 24 months from manufacture when stored at 2–8 °C in sealed foil pouch |
| Brand | Merck |
|---|---|
| Origin | USA |
| Product Type | Imported Reagent Test Strips |
| Model Series | MQuant® Hydrogen Peroxide Test Strips |
| Measurement Range | 0.1–100 mg/L (ppm) H₂O₂ |
| Detection Method | Colorimetric (Peroxidase-catalyzed oxidation of chromogen) |
| Shelf Life | 24 months from manufacture (unopened, stored at 2–8 °C) |
| Format | Individual foil-wrapped strips (100 strips per pack) |
| Compliance | Designed in accordance with ISO 8694:1986 (Water quality — Determination of hydrogen peroxide — Spectrophotometric method) and compatible with GLP/GMP documentation workflows |
| Brand | Merck |
|---|---|
| Origin | USA |
| Product Type | Colorimetric Test Strips |
| Measurement Range | 10–500 mg/L NO₃⁻ |
| Method | Standardized Colorimetric Analysis |
| Pack Size | 100 strips per vial |
| Compliance | Designed for ISO 9001–certified manufacturing |
| Brand | Merck |
|---|---|
| Origin | Germany |
| Test Method | Colorimetric dip-strip assay |
| Detection Range | 0.5 – 20 mg/L NO₂⁻ (as N) |
| Resolution | 0.5 mg/L (semi-quantitative visual readout) |
| Format | Individual strips or strip vials (100 strips/vial) |
| Storage | 2–8 °C, protected from light and moisture |
| Shelf Life | 24 months from manufacture date when unopened |
| Compliance | Designed in accordance with ISO 8467:1993 (Water quality — Determination of nitrite nitrogen — Spectrophotometric method) and compatible with EPA Method 353.2 (Nitrite by Colorimetric Dip-and-Read Strips) |