Environmental Monitoring Instruments
Filter
Showing 5521–5550 of 9112 results
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | M Air T Air Microbial Sampler |
| Pricing | Available Upon Request |
| Brand | M&C |
|---|---|
| Model | ECM-1 / ECM-2 / ECM-EX2-1 / ECM-EX2-2 |
| Origin | Germany |
| Cooling Principle | Compressor-based refrigerated drying with jet-type heat exchanger |
| Dew Point Range | Adjustable from +2 °C to +7 °C |
| Dew Point Accuracy | ±0.1 °C |
| Heat Exchanger Capacity | ECM-1/ECM-EX2-1: 1 × 250 Nl/h |
| ECM-2/ECM-EX2-2 | 2 × 150 Nl/h |
| Ambient Operating Temperature | Up to 50 °C |
| Certification | ATEX II 2G Ex db IIB T4 Gb, CSA C/US Class I Div 2, FM Class I Div 2, cCSAus |
| Condensate Removal | Peristaltic pump SR25.2 or automatic drain AD |
| Display | Front-panel digital temperature controller with real-time cooling temperature readout and alarm relay output (active at <2 °C or >8 °C) |
| Mounting | Compact rear-panel mounting |
| Housing Material Options | Standard heat exchanger tubes available in borosilicate glass, stainless steel (316L), or PVDF |
| Compliance | Designed for integration into EN 15267-, EPA PS-11-, and ISO 16911-compliant flue gas monitoring systems |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | M90S |
| Instrument Type | Online Water Quality Analyzer |
| Measurement Principles | Photometric (Colorimetric), Ion-Selective Electrode (ISE), and Specialized High-Purity Water Analysis Modules |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Regional Origin | Domestic (China) |
| Model | MA-003 |
| Pricing | Available Upon Request |
| Brand | Macam |
|---|---|
| Origin | United Kingdom |
| Model | Irradian PM203 |
| Optical Detector | Silicon photodiode |
| Spectral Range | 200–1100 nm |
| Calibration Accuracy | ±5% (400–1100 nm), ±7.5% (240–400 nm) |
| Power Range (Standard) | 0.001 nW – 199.99 µW (5 auto-ranging scales) |
| Power Range (Extended Option) | 10 nW – 1.9999 mW |
| Resolution | 0.001 nW (standard), 0.01 nW (extended) |
| Display | 4½-digit LCD, 10 mm digit height, LED backlight |
| Interface | RS232 (3-wire, 4800 baud, no parity, 1 stop bit) |
| Integration Time | 0.33 s |
| Linearity Error | <1% |
| Operating Temperature | 0–40 °C, 80% RH |
| Dimensions (Display Unit) | 150 × 80 × 45 mm |
| Weight | ~350 g |
| Detector Housing | Black anodized aluminum, 1.125" × 20 TPI thread |
| Traceability | NIST-traceable calibration |
| Brand | Macam |
|---|---|
| Origin | United Kingdom |
| Model | L202 |
| Display Unit | L201 |
| Detector | DET201L-Cos |
| Measurement Units | lux (illuminance), cd/m² (luminance) |
| Spectral Match | CIE V(λ) with <1% photopic error |
| Cosine Correction | High-precision acrylic diffuser, deviation <5% up to 70° from normal |
| Accuracy | ±2 digits + 1% linearity (1–20,000 lux), absolute calibration traceable to NPL |
| Operating Temperature | 0–40°C, 80% RH |
| Detector Temp. Coefficient | −0.10%/°C |
| Resolution | 1 lux |
| Display | 4½-digit LCD, 10 mm digit height, backlighted |
| Power | 9 V PP3 battery |
| Dimensions (Display) | 150 × 80 × 45 mm |
| Weight (Display) | 0.35 kg |
| Detector Diameter | 38 mm, Height: 30 mm |
| Interface | 8-pin mini-DIN (detector), RS232 (factory use only) |
| Brand | Macam |
|---|---|
| Origin | United Kingdom |
| Model | Q203 |
| Measurement Range (PAR) | 1.9999–19999 μmol·m⁻²·s⁻¹ |
| Spectral Range (PAR) | 400–700 nm |
| Spectral Range (Irradiance) | 400–1000 nm (configurable) |
| Units | μmol·m⁻²·s⁻¹, lux, W·m⁻² |
| Detector | Si photodiode (33 mm²) |
| Cosine Error | ≤ ±3.5° (0–70° from normal) |
| Display | 4½-digit LCD, 10 mm digits, LED backlight |
| Interface | RS232 (4800 baud, 3-wire) |
| Power | 9 V PP3 battery (~50 h operation, no backlight) |
| Operating Temp. | 0–40 °C (detector: –10–+60 °C) |
| Weight | ~350 g |
| Brand | Macam |
|---|---|
| Origin | United Kingdom |
| Model | SR9910 |
| Optical Input Channels | 2 |
| Spectral Range | 240–800 nm |
| Detector Type | UV-enhanced CCD array |
| Calibration Traceability | NPL-traceable irradiance calibration |
| Sensor Compatibility | Spherical and planar irradiance sensors |
| UV Measurement Capability | Simultaneous UVA (315–400 nm) and UVB (280–315 nm) irradiance |
| Typical Applications | In-water radiometric profiling, aquatic photobiology, optical oceanography, satellite validation, water quality parameter inversion |
| Brand | Macam |
|---|---|
| Origin | United Kingdom |
| Model | SR9910-V7 |
| Spectral Range | 240 nm – 800 nm |
| Optical Resolution (FWHM) | 0.25 nm |
| Slit Width Options | 2 nm (standard), 1 nm (optional) |
| Wavelength Accuracy | ±0.5 nm |
| Stray Light | <2 × 10⁻⁷ |
| Detector | Thermoelectrically Cooled Multi-Alkali Photomultiplier Tube (PMT) |
| Input Optics | Fiber-Coupled with Cosine Corrector (±3°–70° angular response) |
| Monochromator | Dual-Grating, 100 mm Focal Length |
| Filter Wheel | 4-position |
| Integration Time Range | Adjustable from 1 ms to 10 s (software-controlled) |
| Data Interface | USB 2.0 (with RS-232 adapter included) |
| Dimensions | 36 cm × 36 cm × 16 cm |
| Weight | 10.1 kg |
| Power Supply | 12 V DC |
| Brand | Macam |
|---|---|
| Origin | United Kingdom |
| Model | UV203-3 |
| Detector Configuration | Triple-channel (UVA, UVB2, RFF/Vis) |
| Submersible Depth Rating | 10 m |
| Display | 4½-digit LCD (10 mm digit height) |
| Microprocessor | 80C51-based, 3.1684 MHz clock |
| Memory | Onboard non-volatile RAM for calibration coefficients and settings |
| Gain Control | Auto/manual selectable per channel |
| Integration Time | 0.33 s |
| ADC Resolution | 17-bit |
| Accuracy | ±1 digit, linearity error < 1% |
| Cosine Response Error | ≤ ±3% (0–70° from normal incidence) |
| Operating Temperature | 0–40 °C, 80% RH |
| IP Rating | IP67 |
| Power | Two 9 V PP3 batteries (~150 h typical life, no RS232 active) |
| Interface | 3-wire RS232 (4800 baud, no parity, 1 stop bit) |
| Connectors | 8-pin circular screw-lock (detector), 5-pin (RS232), 3-pin (external power) |
| Weight | ~500 g |
| Dimensions | 180 × 130 × 60 mm |
| Brand | Macam |
|---|---|
| Origin | United Kingdom |
| Model | UV203/3 |
| Detector Configuration | Triple-channel (UVA, UVB2, RFF-Vis) |
| Submersible Depth Rating | 10 m |
| Display | 4½-digit LCD (10 mm digit height) |
| Microprocessor | 80C51-based, 3.1684 MHz clock |
| Memory | Onboard non-volatile RAM for calibration coefficients and settings |
| Gain Control | Auto/manual selectable per channel |
| Integration Time | 0.33 s |
| ADC Resolution | 17-bit |
| Accuracy | ±1 digit, linearity error < 1% |
| Cosine Response Error | ≤ ±3% (0–70° from normal incidence) |
| Operating Temperature | 0–40 °C, 80% RH |
| IP Rating | IP67 |
| Power | Two 9 V PP3 batteries (~150 h typical life, no RS232 active) |
| Interface | 3-wire RS232 (4800 baud, no parity, 1 stop bit) |
| Connectors | 8-pin circular screw-lock (detector), 5-pin (RS232), 3-pin (external power) |
| Detector Housing | Anodized aluminum |
| Detector Type | High-stability silicon (UVA, RFF-Vis) and GaAs (UVB2) photodiodes with individual low-noise, high-gain amplifiers and digital signal generators |
| Spectral Calibration | Traceable to NPL standards |
| Measurement Modes | Instant irradiance, min/max during averaging, integrated radiant exposure (mJ/m² or J/m²) |
| Zeroing | Background zero measurement with auto-store on power-off |
| Brand | Macherey-Nagel |
|---|---|
| Origin | Germany |
| Model | BioFix Lumi-10 |
| Instrument Type | Laboratory |
| Biological Agent | *Aliivibrio fischeri* (formerly *Vibrio fischeri*) |
| Operating Temperature | 18–25 °C |
| Reagent Storage & Assay Temperature | 20–25 °C |
| Coefficient of Variation (CV) | ≤5% (RSD) |
| Batch Capacity | 10 samples per run |
| Assay Duration | 30 minutes per batch |
| Detection Principle | Bioluminescence Inhibition/Enhancement |
| Photomultiplier Detector | Ultrafast Single-Photon Counter |
| Wavelength Range | 380–630 nm |
| Light Intensity Range | 0–120,000,000 photons/s |
| Detection Limit | 1 RLU |
| Display | Backlit monochrome LCD (128 × 64 pixels) |
| Data Storage | 2000 test records |
| Environmental Operating Range | 15–30 °C, 10–90% RH (non-condensing) |
| Power Supply | Rechargeable battery or AC adapter (230 V/50 Hz or 115 V/60 Hz) |
| Dimensions | 170 × 150 × 280 mm |
| Weight | 2.0 kg (including battery) |
| Compliance | EN ISO 11348-1/2/3, CE marked per 2006/95/EC (LVD) and 2004/108/EC (EMC) |
| Brand | Macherey-Nagel |
|---|---|
| Origin | Germany |
| Model | Lumi-10 |
| Detector | Ultra-high-speed single-photon-counting photomultiplier tube (PMT) |
| Wavelength Range | 380–630 nm |
| Display | LED, 128 × 64 pixels |
| Data Storage Capacity | 2,000 measurements |
| Operating Temperature | 15–30 °C |
| Relative Humidity | 10–90 % RH (non-condensing) |
| Power Supply | 3 × rechargeable Ni-Cd batteries or AC adapter (230 V/50 Hz or 115 V/60 Hz) |
| Dimensions (H×W×D) | 170 × 150 × 280 mm |
| Weight | 2.0 kg (including batteries) |
| Dynamic Range | >6 decades |
| Interface | RS-232 serial port |
| Preloaded Assay Templates | 6 |
| Language Options | English and German |
| Security | Password-protected user access |
| Compliance | EN ISO 11348-3, Directive 73/23/EEC (Low Voltage), Directive 89/336/EEC (EMC, incl. 92/31/EEC amendment) |
| Brand | Macherey-Nagel |
|---|---|
| Origin | Germany |
| Model | BioFix® Lumi-10 |
| Instrument Type | Portable |
| Biological Agent | *Aliivibrio fischeri* (formerly *Vibrio fischeri*) bioluminescent bacteria |
| Operating Temperature Range | 15–30 °C (recommended), functional range: 0–40 °C |
| Reagent Storage & Use Temperature | 0–40 °C |
| Coefficient of Variation (CV) | <10% |
| Photon Detection Speed | 5,000 photons per 0.1 s |
| Assay Duration | Default 10 s (adjustable from 0.5–20 s) |
| Detector | Fast single-photon-counting photomultiplier tube (PMT) |
| Wavelength Sensitivity | 380–630 nm |
| Display | LED, 128 × 64 pixels |
| Data Storage Capacity | 2,000 measurement records |
| Power Supply | 3× rechargeable Ni-Cd batteries or AC adapter (230 V/50 Hz or 115 V/60 Hz) |
| Dimensions (H×W×D) | 170 × 150 × 280 mm |
| Weight | 2.0 kg (including batteries) |
| Compliance | Low Voltage Directive 73/23/EEC, EMC Directive 89/336/EEC (incl. amendment 92/31/EEC) |
| Brand | Macherey-Nagel |
|---|---|
| Origin | Germany |
| Model | Vario mini |
| Digestion Method | Rapid Digestion |
| Heating Module | Single Block Heater |
| Batch Capacity | 6 samples |
| Temperature Range | 70–160 °C |
| Temperature Accuracy | ±1 °C |
| Sample Vessel Capacity | 60 mL |
| Timer Accuracy | ±1 min |
| Display | Graphical LCD (124 × 64 px) |
| Preset Temperatures | 70, 100, 120, 148, 150, 160 °C |
| Temperature Stability | ±1 °C (compliant with DIN, EN, ISO, and EPA standards) |
| Ramp Time | ≤25 min (20 °C → 160 °C at ambient 20 °C) |
| Digestion Durations | 30, 60, 120 min selectable |
| Safety Features | Lockable hinged safety lid, overheat protection |
| Interface | Mini-USB |
| Calibration Support | NANOCOLOR USB T-Set included for automated temperature verification and traceable calibration |
| Power Supply | 12 V DC, 5 A |
| Power Consumption | 60 W |
| Dimensions (W×D×H) | 105 × 125 × 170 mm |
| Weight | 0.67 kg (without power adapter) |
| Operating Environment | 10–40 °C, ≤80% RH (non-condensing) |
| Certification | CE |
| Warranty | 1 year |
| Brand | Macherey-Nagel |
|---|---|
| Origin | Germany |
| Model | PF-12 Plus |
| Instrument Type | Portable / Handheld Water Quality Analyzer |
| Detection Principle | Colorimetric Method |
| Measurable Parameters | Ni, Cu, Cr, COD, Ammonia-N, Total Phosphorus, Total Nitrogen, Turbidity (1–1000 NTU), Residual Chlorine, and up to 60 parameters |
| Optical System | Single-beam filter photometer with 7-position filter wheel (345, 436, 470, 540, 585, 620, 690 nm) + optional 860 nm LED for turbidity |
| Wavelength Accuracy | ±2 nm |
| Spectral Bandwidth | 10–12 nm |
| Photometric Range | ±3 A |
| Photometric Accuracy | ±1% |
| Stability | <0.002 A/h |
| Sample Cell | 16 mm round cuvette |
| Data Storage | 1000 measurements, GLP-compliant |
| Display | Backlit LCD (64×128 pixels) |
| Interface | USB 2.0 |
| Protection Rating | IP68 |
| Operating Temperature | 10–40 °C, RH ≤80% |
| Power Supply | USB bus power, AA alkaline/rechargeable batteries, or 12 V automotive adapter |
| Dimensions | 215 × 100 × 65 mm |
| Weight | 0.7 kg |
| Certification | CE |
| Brand | Madur |
|---|---|
| Origin | Austria |
| Model | CMS-7 |
| Instrument Type | Continuous Emission Monitoring System (CEMS) |
| Accuracy | ±5% of reading |
| Repeatability | ≤2% |
| Response Time (T90) | 45 s |
| Stability | ≤5% drift over 1 h |
| Gas Detection Principle | NDIR (CO₂, CH₄, CO), Electrochemical (CO, NO, NO₂, SO₂, H₂S, H₂), Paramagnetic/Zirconia (O₂) |
| Temperature Range (Operating) | 10–40 °C |
| Dimensions (L×H×W) | 600 × 635 × 518 mm |
| Weight (excl. probe) | 48 kg |
| Display | 320×240 pixel backlit LCD |
| Data Storage | 256 MB MMC card |
| Analog Outputs | 8 channels, 0–10 V / 0/4–20 mA |
| Communication | RS232C |
| Power Supply | 230 VAC, 50–60 Hz |
| Sample Flow Rate | 90 L/h (adjustable diaphragm pump) |
| Condensate Handling | Peltier-cooled condensate separator with peristaltic pump |
| Heated Sampling Line | 3 m, integrated 20 µm filter |
| Probe | Heated gas probe (standard 300 mm, custom lengths available) |
| Pressure Measurement | Differential and absolute pressure sensors (±25 hPa, 800–1200 hPa), resolution 0.1–1 Pa (configurable) |
| Flow Velocity | Pitot tube-based, 1–30 m/s |
| Brand | Madur |
|---|---|
| Origin | Austria |
| Model | GA-12plus |
| Instrument Type | Portable Flue Gas Analyzer |
| Accuracy (Indication Error) | ≤5% |
| Repeatability | ≤2% |
| Response Time | 45 s |
| Stability | ≤5% |
| Optional Electrochemical Sensors | NO, NO₂, SO₂, H₂S |
| Ambient CO Resolution | 0.1 ppm |
| Temperature Measurement Range | Flue Gas & Ambient Air |
| Differential Pressure Resolution | 0.1 Pa |
| Bacharach Smoke Number Test (Electronically Controlled Flow | 1.631 L/min) |
| Calculated Parameters | CO₂, Combustion Efficiency, Excess Air, Lambda, Losses, etc. |
| Data Storage | 32 Reports |
| Display | Backlit LCD (66 × 36 mm) |
| Battery Life | Up to 75 h (6 V, 4×AA Alkaline or Rechargeable) |
| Operating Temperature | 10–50 °C |
| Storage Temperature | −20–+55 °C |
| Dimensions (W×D×H) | 245 × 90/128 × 60 mm |
| Weight | 700 g |
| Probe Length | 150 mm |
| Gas Hose Length | 2 m |
| In-line Filter | 20 µm |
| Interface | IR, RS-232C |
| Compliance | EN 50379-1 & EN 50379-2 |
| Brand | Madur |
|---|---|
| Origin | Austria |
| Model | GA-21plus |
| Instrument Type | Portable Flue Gas Analyzer (not CEMS) |
| Measurement Principle | Electrochemical (O₂, CO, NO, NO₂, SO₂, H₂S, Cl₂, H₂) & NDIR (CO₂, CH₄) |
| O₂ Range | 0–25% (electrochemical) / 0–100% (bias-cell) |
| CO Range | 0–20,000 ppm |
| NO/NOₓ Range | 0–5,000 ppm |
| NO₂ Range | 0–1,000 ppm |
| SO₂ Range | 0–5,000 ppm |
| H₂S Range | 0–1,000 ppm |
| Cl₂ Range | 0–300 ppm |
| H₂ Range | 0–1,000 ppm |
| CO₂ Range | 0.5% or 0–100% (NDIR) |
| CH₄ Range | 0.5% or 0–100% (NDIR) |
| Gas Temperature | –40 to 1600 °C |
| Ambient Temperature | –40 to 100 °C |
| Pressure Range (Differential) | –25 to +25 hPa |
| Atmospheric Pressure | 800–1200 mbar |
| Flow Velocity | 0–50 m/s |
| Response Time (T₉₀) | 45 s (gas sensors), 30 s (temperature), 10 s (pressure/flow) |
| Accuracy | ±5 ppm or ±5% rel (electrochemical gases) |
| Repeatability | 5 ppm |
| Zero Drift Stability | ≤5% over 1 h |
| Display | Backlit graphical LCD (simultaneous multi-parameter view) |
| Data Storage | Internal memory for 1024 records (10 databases), up to 10 variables per record |
| Interface | RS232C |
| Power | 230 V/50 Hz or 110 V/60 Hz AC |
| Dimensions | 460 × 170 × 160 mm |
| Weight | 6.2 kg |
| Operating Temp. | 10–50 °C |
| Storage Temp. | –20 to +55 °C |
| Probe Max Temp. | ≥800 °C |
| Compliance | Meets SCAQMD requirements including automatic O₂ correction |
| Brand | Madur |
|---|---|
| Origin | Austria |
| Model | GA-60 |
| Instrument Type | Continuous Emission Monitoring System (CEMS) |
| Measurement Principle | Electrochemical & NDIR (Non-Dispersive Infrared) Sensor Technology |
| Accuracy (CO) | ±5 ppm |
| Repeatability | ≤2% |
| Response Time (T90) | 45 s |
| Stability | ≤5% |
| Gas Channels | 5 standard electrochemical sensors + up to 2 additional electrochemical + 3 NDIR sensors |
| Data Storage | 1 million records (256 MB) |
| Display | 320 × 240 pixel backlit LCD |
| Printer | Integrated 57 mm dot-matrix thermal printer |
| Power Supply | 12 V / 2.2 Ah rechargeable lead-acid battery (6 h operation) or 110–220 V AC adapter |
| Dimensions (L×H×W) | 500 × 410 × 180 mm |
| Weight | 9.5 kg |
| Operating Temperature | 10–50 °C |
| Storage Temperature | −20–55 °C |
| Humidity Range | 5–90% RH (non-condensing) |
| Pressure Resolution | 1 Pa (differential), 0.1 hPa (ambient, optional) |
| Temperature Inputs | 8 channels (4 thermocouples + 4 thermistors, optional) |
| Flow Control | Electronically regulated peristaltic pump (90 L/h nominal, 1.63 L/min sampling flow) |
| Sample Conditioning | Peltier-based gas dryer + heated probe (300 mm standard) + 5 µm/20 µm particulate filters |
| Brand | Madur |
|---|---|
| Origin | Austria |
| Model | GA40Tplus |
| Instrument Type | Continuous Emission Monitoring System (CEMS) |
| Accuracy | ±5 ppm |
| Repeatability | ≤2% |
| Response Time | 45 s |
| Stability | ≤5% |
| Sensor Configuration | Up to 8 sensors (6 electrochemical + 2 infrared) |
| Analog Inputs | 6 (voltage, current, temperature) |
| Analog Outputs | 2 (optional) |
| Data Storage | 1024 records across 10 databases |
| Display | 128×112-pixel backlit LCD |
| Printer | High-speed dot-matrix, 56 mm paper |
| Power | 110/230 V AC, 50/60 Hz |
| Dimensions | 460 × 170 × 160 mm |
| Weight | 10 kg |
| Brand | Madur |
|---|---|
| Origin | Austria |
| Model | PHOTON |
| Instrument Type | Portable Flue Gas Analyzer |
| Measurement Principle | Non-Dispersive Infrared (NDIR) + Electrochemical Sensors |
| Accuracy | ≤3% FS |
| Repeatability | ≤2% FS |
| Response Time (T90) | 45 s |
| Stability | ≤5% FS |
| Measured Gases | SO₂, NO, NO₂, CO, CO₂, CH₄, VOCs (via optional electrochemical sensors), O₂ |
| Operating Temperature | 0–50 °C |
| Storage Temperature | −20–+55 °C |
| Dimensions (W×H×D) | 500 × 340 × 150 mm |
| Weight | ~7 kg |
| Power Supply | 90–230 VAC, 50–60 Hz |
| Display | Backlit LCD, 320 × 240 px |
| Data Memory | 65,535 records |
| Analog I/O | 8-channel configurable voltage/current input/output |
| Compliance | Designed for EN 15267, EN 14181, ISO 12039, and EPA Method 6C/7E compatibility |
| Brand | Madur |
|---|---|
| Origin | Austria |
| Model | PHOTON S |
| Instrument Type | Continuous Emission Monitoring System (CEMS) |
| Measurement Principle | Non-Dispersive Infrared (NDIR) + Electrochemical Sensors |
| Accuracy (Indication Error) | ≤3% FS |
| Repeatability | ≤2% FS |
| Response Time (T90) | 45 s |
| Stability | ≤5% FS/7 days |
| Measured Gases | SO₂, NO, NO₂, O₂, CO, CO₂ |
| Brand | MAE |
|---|---|
| Country of Origin | Italy |
| Model | A6000S |
| Instrument Type | Portable Seismograph |
| ADC Resolution | 24-bit |
| Dynamic Range | 144 dB (theoretical) |
| Total Harmonic Distortion | ±0.001% |
| Bandwidth | 2 Hz to 30 kHz |
| Common-Mode Rejection Ratio | 110 dB @ 60 Hz |
| Input Noise Floor | 27 nV |
| Trigger Accuracy | ±1/30 sampling interval |
| Input Voltage Range | ±5 V |
| Input Impedance | 20 MΩ @ 1 kS/s |
| Programmable Gain | 0, 6, 12, 18, 24, 30, 36 dB (per-channel configurable) |
| Anti-Aliasing Filter | −3 dB at 80% Nyquist frequency, −80 dB stopband attenuation |
| Sampling Intervals | 0.033 ms to 20 ms (discrete steps) |
| Sample Count per Acquisition | 1,024–21,800 (512-sample increments) |
| Pre-trigger Time | 1–500 ms (26 selectable values) |
| Channel Configuration | 12 or 24 channels (user-selectable per acquisition) |
| Acquisition Modes | Triggered (all channels), Continuous (up to 12 channels) |
| Calibration | Automatic ADC calibration prior to each acquisition |
| Digital Filtering | Auto-configured based on sampling rate |
| Data Storage | Host PC internal storage |
| Trigger Polarity | Positive or negative (software-selectable) |
| Data Format | SEG-2 (32-bit binary) or ASCII |
| Sensor Diagnostics | Real-time open-circuit, short-circuit, and sensor failure detection via cable signal analysis |
| Interfaces | USB 2.0, 10/100/1000BASE-T Ethernet, VGA video output |
| Brand | MAE |
|---|---|
| Origin | Italy |
| Model | C313SEV |
| Output Voltage Range | ±50 V, ±100 V, ±250 V, ±500 V, ±800 V |
| Max Output Current | 5 A |
| Max Output Power | 250 W |
| Current Resolution | ±0.2 µA |
| Potential Measurement Range | ±25 V |
| Input Impedance | 2.5 MΩ |
| Potential Resolution | ±1.5 µV (within ±25 V) |
| Sampling Interval | 0.25 s |
| Noise Reduction | 2–10 sample averaging |
| Built-in Battery | 12 V / 12 Ah |
| Operating Temperature | −20 °C to +80 °C |
| Enclosure Rating | IP42 |
| Display | 7" TFT LCD touchscreen |
| Data Storage | Internal SD card (~3 GB), USB port (included) |
| Data Formats | TSV, CSV, DAT |
| Communication Ports | LAN, USB, VGA |
| Dimensions | 49 × 19 × 26.4 cm |
| Weight | 9.6 kg |
| Operating System | Embedded Windows |
| Language Support | English, Italian |
| Brand | Makewave |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | MCG-M60HBR |
| Pricing | Available Upon Request |
| Control System | PLC with Color Touchscreen HMI |
| Feed Form | Sealed Weighing Valve |
| Discharge Form | Dual-Density Collection System |
| Output Capacity | ≥10 Metric Tons/Year (Reduced Graphene Oxide) |
| External Dimensions | ~10 m (L) × 3 m (D) × 3.6 m (H) |
| Vacuum System | Integrated |
| Atmosphere Control | Multi-Gas Inlet Ports |
| Temperature Monitoring | Multi-Point RTD Sensors |
| Microwave Power | Adjustable |
| Safety Compliance | Microwave Leakage < GB 10436-2008 Limit |
| Brand | MakeWave |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | MHX-16B |
| Frequency | 2450 MHz |
| Time Control Range | 0–99 h |
| Sample Capacity | 1 vessel |
| Temperature Range | 0–900 °C |
| Temperature Control Accuracy | ±1 °C |
| Maximum Power Output | 16 kW (pyrolysis mode), 5 kW (thermal decomposition mode) |
| Chamber Volume | 66 L |
| Chamber Material | Fused quartz |
| Atmosphere Options | Vacuum or oxidizing (air-assisted) |
| Control System | PLC-based industrial automation with real-time monitoring of temperature, pressure, microwave power, and process sequencing |
| Exhaust Compliance | Meets GB 18484–2001 “Pollution Control Standard for Hazardous Waste Incineration” |
| Microwave Leakage | <5 mW/cm² (per GB 10436–2008) |
| Origin | Austria |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MAMOS 100-400 |
| Instrument Type | Continuous Emission Monitoring System (CEMS) |
| Measurement Accuracy | ≤ ±5% of reading |
| Repeatability | ≤ 2% |
| Response Time (T90) | ≤ 90 s |
| Long-Term Stability | ≤ 5% over 30 days |
| Sampling Pump Flow Rate | 1.5 L/min |
| Operating Humidity | 5–95% RH (non-condensing) |
| Ambient Temperature Range | 0–40 °C |
| Power Supply | 24 V AC |
| Power Consumption | ~8 W |
| Enclosure Rating | IP54 |
| Dimensions (H×W×D) | 380 × 300 × 140 mm |
| Weight | ~4 kg |
| Analog Outputs | 4–20 mA (linear), 0–10 V (programmable, linear) |
| Digital Interface | RS232C (TTL level) |
| Signal Averaging Time | 2–32 s (user-configurable) |
| Zero/Measurement Cycle | Fully automated, independently programmable |
| Origin | Austria |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | maMoS-100 |
| Pricing | Upon Request |
| Origin | Austria |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | maMoS-100-400 |
| Instrument Type | Continuous Emission Monitoring System (CEMS) |
| Measurement Accuracy | ≤5% FS |
| Repeatability | ≤2% FS |
| Response Time (T90) | 45 s |
| Stability | ≤5% FS over 30 days |
| Sensor Options | Electrochemical (O₂, CO, NO, NO₂, SO₂, H₂S, Cl₂, H₂) & NDIR (CO, CO₂, CH₄, N₂O) |
| Housing | IP54-rated ABS enclosure |
| Power Supply | 24 V AC, ~8 W |
| Operating Temperature | 0–40 °C |
| Storage Temperature | −20–+55 °C |
| Dimensions (H×W×D) | 380 × 300 × 140 mm |
| Weight | ~4 kg |
| Zero/Measurement Cycle | Fully automated dual-phase sequence with independent timing control |
| Output Signals | 4–20 mA and 0–10 V per channel |
| Digital Interface | RS232 |
| NDIR Response Time | T90 < 10 s |
| Built-in Sample Conditioning | Peltier-cooled dryer, particulate filter, condensate peristaltic pump |
| Calibration | Factory-calibrated sensors |