Environmental Monitoring Instruments
Filter
Showing 5581–5610 of 9112 results
| Brand | Merck |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported |
| Model | MQuant® pH Indicator Strips Series |
| Price | Upon Request |
| Brand | Merck |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | MQuant® Phosphate Test Strips Series |
| Pricing | Available Upon Request |
| Brand | Merck |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported |
| Model Series | MQuant® Total Hardness Test Strips |
| Pricing | Available Upon Request |
| Brand | Merck |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | NOVA30 |
| Instrument Category | Laboratory Water Quality Analyzer |
| Wavelengths | 340, 445, 525, 550, 605, 690 nm |
| Wavelength Accuracy | ±2 nm |
| Spectral Bandwidth | 10 nm |
| Photometric Repeatability | 0.001 A at 1.000 A |
| Absorbance Resolution | 0.001 A |
| Absorbance Range | −0.300 to 3.200 A |
| Light Source | Tungsten Halogen Lamp (no warm-up required) |
| Measurement Time | ~2 seconds per test |
| Cuvette Format | 16 mm round tubes |
| Barcode Method Recognition | Yes |
| AQA Modes | 3 (including zero-point and turbidity correction) |
| Data Storage Capacity | Up to 500 results |
| Interface | RS232-C |
| Real-Time Clock | Integrated |
| Power Supply | 220 V, 50 Hz with optional rechargeable battery |
| Operating Temperature | +5 °C to +40 °C |
| Storage Temperature | −25 °C to +65 °C |
| Relative Humidity | ≤75% (non-condensing) |
| Dimensions (H × D × W) | 140 × 270 × 260 mm |
| Weight | 2.8 kg |
| Brand | Merck |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | NOVA60A |
| Instrument Type | Laboratory Water Quality Analyzer |
| Measured Parameters | COD, Total Phosphorus, Total Nitrogen, and over 50 additional water quality parameters |
| Wavelength Range | 340–820 nm (12 fixed wavelengths) |
| Wavelength Accuracy | ±2 nm |
| Spectral Bandwidth | 10 nm |
| Photometric Repeatability | 0.001 A at 1.000 A |
| Absorbance Resolution | 0.001 A |
| Absorbance Range | –0.300 to 3.200 A |
| Cuvette Compatibility | 10 mm, 20 mm, 50 mm square cuvettes and 16 mm round tubes (auto-recognized) |
| Barcode Method Recognition | Yes |
| Light Source | Tungsten halogen lamp (no warm-up required) |
| Measurement Time | ~2 seconds per test |
| Quality Control Modes | 3 AQA modes (including zero-point correction and turbidity compensation) |
| Internal Memory | Up to 1000 measurement results |
| User-Defined Methods | Up to 50 custom calibration curves (10 at fixed wavelengths) |
| Real-Time Clock | Yes |
| Interface | RS232C (for PC connection, printer output, and method updates) |
| Power Supply | 220 V, 50 Hz |
| Operating Temperature | +5 °C to +40 °C |
| Storage Temperature | –25 °C to +65 °C |
| Relative Humidity | ≤75% (non-condensing) |
| Dimensions (H × D × W) | 140 × 270 × 260 mm |
| Weight | 2.3 kg |
| Battery Option | Rechargeable battery available for field use |
| Brand | Merck |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Spectroquant Multy |
| Price | Upon Request |
| Display | 6-digit LCD with backlight |
| Wavelengths | 430 nm, 530 nm, 560 nm, 580 nm, 610 nm, 660 nm (fixed LED sources) |
| Optical Technology | Dual-beam photometry with interference filter compensation |
| Temperature Compensation | 6-point automatic |
| Sample Holders | 16 mm and 24 mm round cuvettes (included) |
| Dimensions (instrument) | 265 × 195 × 70 mm |
| Dimensions (carrying case) | 440 × 370 × 140 mm |
| Interface | RS232 serial port |
| Power Supply | Rechargeable NiCd battery pack (7 cells) |
| Operating Conditions | 0–50 °C, <90% RH (non-condensing) |
| Data Storage | 1000 measurement records with timestamp, parameter ID, and user-defined sample ID |
| Keypad | Chemical-resistant capacitive touch keys |
| Self-Test | Automatic power-on diagnostic routine |
| Compliance | Designed to support ISO 7027, ISO 8466-1, ASTM D1253, EPA 180.1, and EN ISO 15704 for colorimetric water analysis |
| Brand | Merck |
|---|---|
| Origin | Germany |
| Model | NOVA60 / NOVA60A |
| Instrument Type | Benchtop & Field-Portable Photometric Water Analyzer |
| Wavelength Range | 12 fixed wavelengths (340, 410, 445, 500, 525, 550, 565, 605, 620, 665, 690, 820 nm) |
| Wavelength Accuracy | ±2 nm |
| Spectral Bandwidth | 10 nm |
| Absorbance Repeatability | ±0.001 A at 1.000 A |
| Absorbance Range | –0.300 to 3.200 A |
| Cell Compatibility | 10/20/50 mm square cuvettes and 16 mm round cells with automatic recognition |
| Barcode Method Recognition | Yes |
| Light Source | Tungsten halogen lamp (no warm-up required) |
| Measurement Time | ~2 seconds per test |
| Data Storage | Up to 1,000 results |
| User-Defined Methods | Up to 50 calibration curves |
| Power Supply | 220 V, 50 Hz (NOVA60) |
| Operating Temperature | +5 °C to +40 °C |
| Storage Temperature | –25 °C to +65 °C |
| Dimensions (H × D × W) | 140 × 270 × 260 mm |
| Weight | 2.3 kg |
| Brand | Merck |
|---|---|
| Origin | Germany |
| Model | Spectroquant TR 420 |
| Digestion Method | Rapid Digestion |
| Heating Modules | Dual heating blocks |
| Batch Capacity | 24 × 16 mm digestion tubes |
| Temperature Range | Ambient to 170 °C |
| Temperature Accuracy | ±1.0 °C |
| Display | LCD with real-time setpoint/actual temperature & time monitoring |
| Heating Status Indication | LED (flashing during ramp-up |
| Safety Features | Contact-protected heating surface |
| Preprogrammed Methods | 8 standard digestion protocols |
| Power Supply | 115–230 V, 50–60 Hz |
| Dimensions (H×W×D) | 180 × 256 × 307 mm |
| Weight | 3.6 kg |
| Brand | Merck |
|---|---|
| Origin | Germany |
| Model | Spectroquant® Move |
| Instrument Type | Portable |
| Measurement Principle | Absorption Photometry (LED-based, Fixed-Wavelength) |
| Measured Parameters | Residual Chlorine, Chlorine Dioxide, and Other Water Quality Parameters (via Preloaded Methods) |
| Range | 0.02–6 mg/L |
| Accuracy | ±1 nm (wavelength), ±3% FS (absorbance, 20–25°C) |
| Repeatability | ≤3% RSD |
| Resolution | 0.01 A (absorbance), 1 mAbs (instrumental) |
| LOD | 0.0035 mg/L |
| Wavelength | 530 nm |
| Light Source | High-Stability LED |
| Optical Path | Fixed 10-mm Cuvette Chamber |
| Display | LCD with Backlight |
| Keyboard | Chemical-Resistant Membrane |
| Power | 4 × AAA batteries (up to 17 h operation or ~5,000 measurements) |
| Weight | 260 g |
| Dimensions (H × W × D) | 155 × 75 × 35 mm |
| Carry Case Dimensions | 340 × 270 × 80 mm |
| Ingress Protection | IP68 |
| Data Storage | 16 measurement results |
| Data Transfer | Optional Infrared Interface (Spectroquant® IR Adapter) |
| Brand | Merck |
|---|---|
| Origin | Germany |
| Model | Pharo 100 |
| Instrument Type | Laboratory Water Quality Analyzer |
| Detection Capability | Multi-Parameter (≥50 parameters) |
| Wavelength Range | 320–1100 nm |
| Light Source | Tungsten Halogen Lamp |
| Optical System | Stabilized Single-Beam |
| Spectral Bandwidth | 4 nm |
| Wavelength Accuracy | ±1 nm |
| Absorbance Range | ±3.3 A |
| Absorbance Resolution | 0.001 A |
| Absorbance Accuracy | ±0.003 A (A < 0.600) |
| Cuvette Compatibility | 16 mm round, 10/20/50 mm square (auto-recognized) |
| Data Storage | 1000 test results + 4 MB for spectral/dynamic data (e.g., 100 scans, 400 kinetics curves) |
| Interfaces | 1× USB-A, 1× USB-B, 1× RS232 |
| Compliance | DIN, US EPA certified methods |
| Power | 100–240 V~, 50–60 Hz |
| Operating Temperature | +10 °C to +35 °C |
| Dimensions | 404 × 197 × 314 mm |
| Weight | ~3.7 kg (without battery) |
| Brand | Merck |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Laboratory Water Quality Analyzer |
| Model | Pharo 300 |
| Instrument Type | Benchtop UV-Vis Spectrophotometer for Water Analysis |
| Wavelength Range | 190–1100 nm |
| Light Source | Xenon Flash Lamp |
| Optical Design | Stabilized Single-Beam |
| Spectral Bandwidth | 4 nm |
| Wavelength Resolution | 1 nm |
| Wavelength Accuracy | ±1 nm |
| Absorbance Range | ±3.3 A |
| Absorbance Resolution | 0.001 A |
| Absorbance Accuracy | ±0.003 A (for A < 0.600 A), ±0.5 % (for 0.600 ≤ A ≤ 2.000 A), ±1.0 % (for A > 2.000 A) |
| Cuvette Compatibility | 16 mm round, and 10/20/50 mm square cuvettes with automatic recognition |
| Measurement Modes | Concentration, Absorbance, Transmittance, Multi-Wavelength, Full Spectrum Scan (1 nm increment), Kinetic Assays |
| AQA Levels | AQA1 (PhotoCheck/CertiPUR® wavelength verification), AQA2 (CombiCheck/CertiPUR® system verification), AQA3 (MatrixCheck interference assessment) |
| Data Storage | 1000 measurement results |
| Connectivity | 1× USB-A, 1× USB-B, 1× RS-232 |
| Compliance | DIN, US EPA, GLP-compliant audit trail, 21 CFR Part 11 ready (with optional software configuration) |
| Enclosure Rating | IP31 |
| Operating Temperature | +10 °C to +35 °C |
| Dimensions | 404 × 197 × 314 mm (L × H × W) |
| Weight | 3.7 kg (without battery) |
| Brand | Merck |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Pharo100 |
| Price | Upon Request |
| Wavelength Range | 320–1100 nm |
| Light Source | Tungsten Halogen Lamp |
| Optical Design | Stabilized Single-Beam |
| Spectral Bandwidth | 4 nm |
| Wavelength Resolution | 1 nm |
| Wavelength Accuracy | ±1 nm |
| Absorbance Range | ±3.3 A |
| Absorbance Resolution | 0.001 A |
| Absorbance Accuracy | ±0.003 A (for A < 0.600 A) |
| Cuvette Types | 16 mm round, and 10/20/50 mm square (auto-recognized) |
| Measurement Modes | Concentration, Absorbance, Transmittance, Multi-Wavelength, Full Spectrum Scan, Kinetics |
| AQA Levels | AQA1 (PhotoCheck/CertiPUR® wavelength verification), AQA2 (CombiCheck/CertiPUR® system verification), AQA3 (MatrixCheck interference assessment) |
| Data Storage | 1000 measurement results |
| Interfaces | 1× USB-A, 1× USB-B, 1× RS-232 |
| Compliance | DIN, USEPA, GLP-compliant audit trail, 21 CFR Part 11 ready (with optional software configuration) |
| Brand | Merck |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Picco Cl₂/O₃/pH/ClO₂/CyA |
| Instrument Type | Laboratory & Field-Portable Water Quality Analyzer |
| Optical System | Wavelength-Specific LED Light Source with Interference Filter |
| Measurement Wavelength | 528 nm |
| Measurement Time | 3–4 seconds per test |
| Power Supply | 9-V Alkaline Battery (≈600 measurements per battery) |
| Auto Power-Off | Activated after ≈5 minutes of inactivity |
| Operating Temperature | 5–40 °C |
| Operating Humidity | 30–90 % RH (non-condensing) |
| Compliance | CE-marked per DIN EN 55022, EN 61000-4-2, EN 61000-4-8, EN 50082-2, EN 50081-1, DIN V ENV 50140, EN 50204 |
| Brand | Merck |
|---|---|
| Origin | Germany |
| Model | Picco COD |
| Instrument Type | Portable |
| Wavelength | 610 ± 20 nm |
| Measurement Range | 0–10000 mg/L (multi-range, segmented) |
| Accuracy | ≤ ±10% |
| Repeatability | ≤ ±5% |
| LOD | 0.1 mg/L |
| Measurement Time | < 5 seconds (post-digestion) |
| Batch Capacity | 12 or 24 samples (digestion-dependent) |
| Power Supply | 9-V alkaline battery (≈600 measurements) |
| Operating Temperature | 5–40 °C |
| Relative Humidity | 30–90% RH (non-condensing) |
| Compliance | CE marked per DIN EN 55022, EN 61000-4-2, EN 61000-4-8, EN 50082-2, EN 50081-1, DIN V ENV 50140, EN 50204 |
| Brand | Merck |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Picco COD/CSB |
| Pricing | Available Upon Request |
| Optical System | LED Light Source with Interference Filter at 605 nm |
| Measurement Accuracy | ±3.5% |
| Measurement Time | 3–4 seconds |
| Operating Temperature | 5–40 °C |
| Operating Humidity | 30–90% RH (non-condensing) |
| Power Supply | 9-V Alkaline Battery (≈600 measurements per set) |
| Auto-Off Delay | ~5 minutes after last keypress |
| Safety Certifications | CE compliant per DIN EN 55022, EN 61000-4-2, EN 61000-4-8, EN 50082-2, EN 50081-1, DIN V ENV 50140, EN 50204 |
| Sample Cell Format | 16 mm round glass cuvettes |
| Required Pre-treatment | Digestion using external COD digestion unit (e.g., Merck Spectroquant® Thermoreactor) |
| Brand | Merck |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Picco F |
| Pricing | Upon Request |
| Brand | Supelco |
|---|---|
| Origin | Germany |
| Model | Prove100 / Prove300 / Prove600 |
| Instrument Type | Laboratory Water Quality Analyzer |
| Detection Parameters | COD, Ammonia-N, Total Phosphorus, Total Nitrogen |
| Wavelength Range | Prove100: 320–1100 nm |
| Prove300 & Prove600 | 190–1100 nm |
| Light Source | Prove100: Tungsten Halogen Lamp |
| Prove300 & Prove600 | Xenon Flash Lamp |
| Spectral Bandwidth | Prove100 & Prove300: 4 nm |
| Prove600 | 1.8 nm |
| Absorbance Range | ±3.0 Abs |
| Absorbance Resolution | 0.001 Abs |
| Wavelength Accuracy | ±1 nm |
| Stray Light | ≤0.1% T at 340 nm (all models) |
| Sample Holders | 16-mm round cuvettes |
| Built-in Methods | Pre-programmed Spectroquant® test protocols + 99 user-defined methods + 20 wavelength-scan/dynamic methods |
| Compliance | EN 61010-1, IEC 61010-1, EN IEC 61326-1, 2004/108/EC |
| IP Rating | IP31 |
| Operating Temperature | 10–35 °C |
| Dimensions | 416 × 276 × 237 mm |
| Weight | 6.8 kg |
| Brand | Merck |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Laboratory Water Quality Analyzers |
| Models | TR320, TR420, TR620 |
| Detection Parameters | COD, Total Phosphorus (TP), Total Nitrogen (TN) |
| Sample Capacity | TR320 – 12 × 16 mm tubes |
| TR420 & TR620 – 24 × 16 mm tubes (TR620 | two independent 12-position blocks) |
| Temperature Range | TR320 – 100 °C, 120 °C, 148 °C (fixed) |
| Temperature Uniformity | ±1.5 °C max deviation between center and peripheral wells |
| Heating Time Range | TR320 – preset only |
| Predefined Programs | 7 standard digestion protocols (e.g., 148 °C/20 min for COD, 120 °C/60 min for TP) |
| User-Defined Programs | TR420 & TR620 support up to 8 custom methods |
| Compliance Features | Optional external temperature probe for analytical quality assurance (AQA) |
| Power Supply | 115 V~ / 230 V~, 50/60 Hz |
| Dimensions (H×W×D) | 180 × 256 × 307 mm |
| Weight | TR320 – 2.85 kg |
| Brand | Supelco |
|---|---|
| Origin | Germany |
| Model | Spectroquant® Move100 |
| Instrument Type | Portable/HANDHELD Water Quality Analyzer |
| Detection Parameters | COD, Ammonia-N, Total Nitrogen, Total Phosphorus, Free Chlorine, Total Chlorine, Hardness, Phosphate, Sulfate, Iron, Copper, etc. |
| Light Source | LED (430, 530, 560, 580, 610, 660 nm) |
| Wavelength Accuracy | ±2% of range |
| Photometric Range | 0–2 A |
| Linearity Accuracy | ±0.002 A (0–1 A) |
| Linearity Repeatability | ±0.002 A (0–1 A) |
| Wavelength Selection | Automatic |
| Readout Modes | % Transmittance, Absorbance, Concentration |
| Data Storage | 1,000 measurements with timestamp, ID, and sample registration |
| Connectivity | IRiM infrared transmitter + PC interface via USB/serial adapter |
| Power Supply | 4 × AA alkaline batteries |
| Ingress Protection | IP68 |
| Weight | 470 g |
| Operating Environment | 0–50 °C, ≤90% RH |
| Included Accessories | Instrument body, carrying case, 4 AA batteries, three 24-mm cuvettes, three 16-mm cuvettes, adapter, mini screwdriver, user manual, certificate of conformity |
| Brand | Supelco |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Spectroquant® Prove |
| Instrument Type | Laboratory Water Quality Analyzer |
| Measurable Parameters | COD, Ammonia-Nitrogen, Total Phosphorus, Total Nitrogen |
| Optical Range | Prove 100 (320–1100 nm), Prove 300/600 (190–1100 nm) |
| Light Source | Tungsten Halogen (Prove 100), Xenon Flash Lamp (Prove 300 & 600) |
| Spectral Bandwidth | 4.5 nm (Prove 100/300), 1.8 nm (Prove 600) |
| Cuvette Compatibility | Round (13 mm, 16 mm) and Rectangular (10 mm, 20 mm, 50 mm, 100 mm) |
| AQA Compliance | Built-in Analytical Quality Assurance per ISO/IEC 17025 and DIN EN ISO 9001 guidelines |
| Data Transfer | USB, Bluetooth, optional Ethernet |
| Software | Spectroquant® Method Manager v5.x with FDA 21 CFR Part 11-compliant audit trail |
| Brand | Supelco |
|---|---|
| Origin | Germany |
| Model | TR320 / TR420 / TR620 |
| Digestion Method | Rapid Digestion |
| Heating Modules | Dual Independent Blocks (TR620), Single Block (TR320/TR420) |
| Batch Capacity | 12–24 samples (16 mm digestion tubes) |
| Temperature Range | Ambient to 170 °C (adjustable in 1 °C increments) |
| Temperature Accuracy | ±1.0 °C |
| Inter-Zone Uniformity | ±1.5 °C (vs. setpoint, center vs. periphery) |
| Timer Range | 0–180 min |
| Timer Accuracy | ±1 min |
| Power Supply | 115–230 V~, 50/60 Hz |
| Dimensions (H×W×D) | 180 × 256 × 307 mm |
| Weight | TR320: 2.85 kg |
| TR420/TR620 | 3.6 kg |
| Brand | Merck |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Total Alkalinity Titration Test Kit |
| Pricing | Available Upon Request |
| Brand | Merck |
|---|---|
| Origin | Germany |
| Model | TR 320 |
| Digestion Method | Rapid Digestion |
| Heating Modules | Dual Independent Heating Blocks |
| Batch Capacity | 12 samples |
| Temperature Setpoints | 100 °C, 120 °C, 148 °C |
| Temperature Accuracy | ±1.0 °C |
| Digestion Tube Diameter | 16 mm |
| Display | LCD with Real-Time Setpoint & Actual Temperature/Time Monitoring |
| Safety Features | Touch-Safe Heating Surface, Integrated Protective Cover |
| Power Supply | 115–230 V, 50–60 Hz |
| Dimensions (H×W×L) | 180 × 256 × 307 mm |
| Weight | 2.85 kg |
| Brand | Mercury Instruments |
|---|---|
| Origin | Germany |
| Model | SM-4 Mobile |
| Detection Principle | Cold Vapor Atomic Fluorescence Spectrometry (CVAFS) with Gold Amalgamation Pre-concentration |
| Measurement Range | 0.05–100 µg/m³ (Hg⁰, Hg²⁺, Hgₚ after catalytic conversion) |
| Response Time (t₉₀) | ≤180 s |
| Sample Line Length | Up to 73 m (240 ft) |
| Dilution Ratio | Adjustable, typically 1:10 to 1:100 |
| Operating Temperature | Heated sample path up to 180 °C |
| Compliance | EPA Method 29 / ASTM D6784-22 / EN 14181 QAL1 & QAL3 certified |
| Calibration Options | Integrated NIST-traceable elemental Hg vapor generator (optional), QAL3-compliant ionized Hg⁰ calibration source (optional) |
| Brand | Mercury Instruments |
|---|---|
| Origin | Germany |
| Model | SM-4 Mobile |
| Measurement Principle | Thermal Catalytic Conversion + Gold Amalgamation Cold Vapor Atomic Fluorescence (CVAFS) |
| Detection Limit | 0.05 µg/m³ |
| Response Time (t₉₀) | ~180 s |
| Sample Line Length | Up to 73 m (240 ft) |
| Dilution Ratio | Adjustable, up to 1:100 |
| Compliance | EU EN 15267-3 certified, US EPA Performance Specification 12A (PS-12A) and RATA validated |
| Calibration Options | Automated Hg⁰ and Hg²⁺ gas generators (NIST-traceable), QAL3-compliant auto-validation module |
| Waste Generation | Zero liquid or solid waste |
| Operating Temperature Range | Probe heated to >180 °C |
| Filter | Heated particulate filter with automatic air-purge cleaning |
| Brand | Met One Instruments (USA) |
|---|---|
| Origin | USA |
| Model | BAM-1020 |
| Certification | EPA EQPM-0798-122 |
| Measurement Principle | Beta Ray Attenuation |
| Range | 0–50 mg/m³ |
| Sampling Method | Impaction with Rotating Glass Impactor |
| Filter Tape | Circular, 30-sample capacity |
| Calibration | Automated zero & span drift correction using reference membrane |
| Data Storage | 182 days internal memory |
| Humidity Control | Integrated heater for RH conditioning |
| Connectivity | RS-232 serial interface |
| Compliance | EPA Reference Method for PM2.5 and PM10 |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | BAM-1020 |
| Pricing | Upon Request |
| Brand | MET ONE |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Stack Emission Heavy Metal & Black Carbon Analyzer |
| Model | BC 1054 |
| Measurement Principle | Optical Absorption (Multi-Wavelength Aethalometer Principle) |
| Measurement Range | <1 ng/m³ to >100,000 ng/m³ (effective) |
| Detection Limit | 0.1 ng/m³ |
| Filter Tape Replacement Interval | 24 hours |
| Operating Temperature Range | 1–40 °C |
| Operating Relative Humidity Range | 10–90 % RH (non-condensing) |
| Operating Pressure Range | 80–106 kPa |
| Wavelengths | 370, 430, 470, 525, 565, 590, 660, 700, 880, 950 nm |
| Time Resolution | Standard 1 min |
| Sample Flow Rate | 2 or 5 L/min (user-selectable) |
| Inlet Compatibility | TSP, PM₁₀, PM₂.₅, PM₁ |
| Calibration Method | Factory-calibrated in smoke chamber against traceable NIST-traceable reference standards per ASTM D6216 and ISO 12103-1 |
| Data Output | Analog (4–20 mA), RS-232/RS-485, Ethernet (TCP/IP), Modbus RTU/TCP |
| Compliance | Designed for EPA Reference Method equivalency assessment |
| Brand | Met One |
|---|---|
| Origin | USA |
| Model | BT-610 |
| Flow Rate | 1.0 cfm (28.3 L/min) |
| Flow Accuracy | ±5% |
| Timing Accuracy | ±10% |
| Repeatability | ±5% |
| Size Channel Resolution | 0.3–10.0 µm (6 calibrated channels at 0.3, 0.5, 1.0, 2.0, 5.0, 10.0 µm) |
| User-Selectable Sizing | 0.3–2.0 µm in 0.1 µm increments |
| Concentration Range | 0–3,000,000 particles/ft³ (0–105,900 particles/m³) |
| Measurement Accuracy | ±10% (per ISO 21501-4 calibration aerosol) |
| Data Storage Capacity | >8,000 sample events |
| Power | Internal 14.8 V Li-ion battery (8 h continuous / 24 h intermittent) |
| Communication Interfaces | RS-232, RS-485, USB, SD card slot |
| Analog Output | 0–5 VDC |
| Environmental Operating Range | 0–40 °C, 10–90% RH (non-condensing) |
| Dimensions (H×W×D) | 22.2 × 17.1 × 21.5 cm (3.67 kg) |
| Compliance | ISO 21501-4, ISO 14644-1, 21 CFR Part 11, CE, ISO 9001 |
| Brand | MET ONE |
|---|---|
| Origin | USA |
| Model | GT-324 |
| Instrument Type | Handheld |
| Flow Rate | 2.83 L/min |
| Flow Accuracy | ±5% |
| Timing Accuracy | ±0.0 s |
| Repeatability | ±5% |
| Size Distribution Accuracy | ±10% |
| Indication Accuracy | ±10% |
| Particle Size Channels | 0.3, 0.5, 0.7, 1.0, 2.5, 5.0, 10.0 µm (selectable 4-channel configuration) |
| Concentration Range | 0–3,000,000 particles/ft³ (0–105,900 particles/L) |
| Data Storage Capacity | 2,200 samples |
| Operating Temperature | 0–50 °C |
| Battery Life | 11 h (Li-ion, 7.2 V) |
| Charging Time | 2.5 h |
| Light Source | 780 nm laser diode, 90 mW |
| Display | 16×2 character LCD |
| Interface | Rotary encoder + membrane keypad |
| Communication | USB |
| Compliance | ISO 21501-4, FDA 21 CFR Part 11 (user access control) |