Environmental Monitoring Instruments
Filter
Showing 7141–7170 of 8685 results
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | D10P-19 |
| Instrument Category | Multi-Ion Analyzer |
| Electrode | 9719BNWP Potassium Composite Electrode |
| Measurement Range (K⁺) | 0.04–39,000 ppm |
| pH Compatibility | 2.5–11 |
| Temperature Range | 0–40 °C |
| Repeatability | ±2% |
| Electrode Dimensions | 110 mm length × 13 mm body diameter × 16 mm cap diameter |
| Cable Length | 1 m |
| Main Unit Ion Range | 0–19,999 (units: ppm, mg/L, M, %, or unitless) |
| Ion Resolution | 1–3 significant digits |
| Ion Accuracy | ±0.1 mV or ±0.05% (whichever is greater) |
| pH Range | −2.000 to 19.999 |
| pH Resolution | 0.1 / 0.01 / 0.001 |
| pH Accuracy | ±0.001 |
| ORP Range | ±1999.9 mV |
| ORP Resolution | 0.1 mV |
| Temperature Range (instrument) | −5 to 105 °C |
| Temperature Accuracy | ±0.1 °C |
| Display | Dual-channel LCD |
| Interfaces | Dual BNC, dual reference electrode ports, dual MiniDIN (for ATC probes) |
| Method Storage | 20 methods |
| Data Storage | 1,000 entries with timestamp |
| GLP Compliance | Yes (audit trail, user passwords, method-level access control) |
| Connectivity | RS232 (bidirectional), optional USB cable |
| Enclosure Rating | IP54 |
| Certifications | CE, CSA, UL, TÜV, FCC Class A |
| Power | 4×AA batteries or universal AC adapter |
| Dimensions | 9.4 cm H × 17.0 cm W × 22.4 cm D |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | D10P-26 |
| Pricing | Available Upon Request |
| Electrode | 9606BNWP Cyanide Ion-Selective Electrode |
| Measuring Range (Cyanide) | 0.2–260 ppm |
| pH Range | 0–14 |
| Temperature Range | 0–80 °C |
| Repeatability | ±2% |
| Electrode Dimensions | Length 110 mm, Body Diameter 13 mm, Cap Diameter 16 mm, Cable Length 1 m |
| Main Unit Ion Concentration Range | 0–19999, Resolution: 1–3 significant digits, Accuracy: ±0.1 mV or ±0.05% (whichever is greater) |
| pH Range | −2.000 to 19.999, Resolution: 0.1/0.01/0.001, Accuracy: ±0.001 pH |
| ORP Range | ±1999.9 mV, Resolution: 0.1 mV |
| Temperature Measurement | −5 to 105 °C, Accuracy: ±0.1 °C |
| Data Storage | 1000 sets with timestamp |
| GLP Compliance | Yes |
| Connectivity | Dual RS232 (bidirectional), optional USB |
| Enclosure Rating | IP54 |
| Certifications | CE, CSA, UL, TÜV, FCC Class A |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Import Status | Imported |
| Model | D10P-29 |
| Price | Upon Request |
| Electrode | 9629BNWP Copper ISE |
| Measurement Range | 6.4×10⁻⁴ – 6354 ppm Cu²⁺ |
| pH Range | 2–12 |
| Temp. Range | 0–80°C continuous / 80–100°C intermittent |
| Reproducibility | ±4% |
| Electrode Dimensions | 110 mm length, 13 mm body dia., 16 mm cap dia., 1 m cable |
| Instrument Resolution | 1–3 sig. fig. (ion), 0.001 pH |
| Accuracy | ±0.001 pH |
| Calibration Points | 2–6 (ion), 1–6 (pH) |
| Data Storage | 1000 entries with timestamp |
| GLP Compliance | Yes |
| Connectivity | RS232, optional USB |
| IP Rating | IP54 |
| Certifications | CE, CSA, UL, TÜV, FCC Class A |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | D10P-32 |
| Pricing | Upon Request |
| Electrode System | 9332BNWP Hardness Half-Cell Electrode + 900100 Single-Junction Reference Electrode |
| Measurement Principle | Potentiometric Ion-Selective Electrode (ISE) Detection of Ca²⁺ and Mg²⁺ |
| pH Range | 7–10 |
| Temperature Range | 0–40 °C |
| Repeatability | ±4% |
| Ion Concentration Range | 6 × 10⁻⁶ M to 1 M (as CaCO₃ equivalent) |
| pH Range (Meter) | −2.000 to 19.999 |
| ORP Range | ±1999.9 mV |
| Temperature Accuracy | ±0.1 °C |
| Data Storage | 1000 entries with timestamp |
| GLP Compliance | Yes (audit trail, password protection, method locking) |
| Connectivity | RS232 and optional USB |
| Enclosure Rating | IP54 |
| Certifications | CE, CSA, UL, TÜV, FCC Class A |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | D10P-35 |
| Price | Upon Request |
| Electrode | 9635BNWP Bromide Composite Electrode |
| Bromide Range | 0.2–79,900 ppm |
| pH Range | 0–14 |
| Temperature Range | 0–80 °C |
| Repeatability | ±2% |
| Electrode Dimensions | 110 mm length, 13 mm body diameter, 16 mm cap diameter, 1 m cable |
| Meter Resolution | 1–3 significant digits (ion mode) |
| Accuracy | ±0.001 pH |
| Calibration Points | 2–6 (ion), 1–6 (pH) |
| Method Storage | 20 methods |
| Data Storage | 1,000 records with timestamp |
| GLP Compliance | Yes (audit trail, password protection, user-defined methods) |
| Connectivity | Dual RS232, optional USB |
| IP Rating | IP54 |
| Certifications | CE, CSA, UL, TÜV, FCC Class A |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | D10P-48 |
| Price | Upon Request |
| Electrode | 9648BNWP Cd²⁺ Composite Electrode |
| Cd²⁺ Measurement Range | 0.01–11,200 ppm |
| pH Range | 2–12 |
| Temp. Range (Continuous) | 0–80°C |
| Temp. Range (Intermittent) | 80–100°C |
| Reproducibility | ±4% |
| Electrode Dimensions | 110 mm (L) × 13 mm (body Ø) × 16 mm (cap Ø) |
| Cable Length | 1 m |
| Ion Concentration Resolution | 1–3 significant digits |
| Relative Accuracy | ±0.1 mV or ±0.05% (whichever is greater) |
| pH Range | −2.000 to 19.999 |
| pH Accuracy | ±0.001 |
| ORP Range | ±1999.9 mV |
| Temp. Accuracy | ±0.1°C |
| Data Storage | 1000 entries with timestamp |
| GLP Compliance | Yes |
| Communication | RS232 (bidirectional), optional USB |
| Enclosure Rating | IP54 |
| Certifications | CE, CSA, UL, TÜV, FCC Class A |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Category | Imported Instrument |
| Model | D10P-53 |
| Pricing | Upon Request |
| ISE Electrode | 9653BNWP |
| Iodide Measurement Range | 0.005–127,000 ppm |
| pH Range | 0–14 |
| Temperature Range | 0–80 °C |
| Reproducibility | ±2% |
| Electrode Dimensions | 110 mm length × 13 mm body diameter × 16 mm cap diameter |
| Cable Length | 1 m |
| Dual-Channel Meter Resolution | 1–3 significant digits |
| Relative Accuracy (Ion) | ±0.1 mV or ±0.05% (whichever is greater) |
| Ion Units | ppm, mg/L, M, %, or unitless |
| Calibration Points | 2–6 |
| pH Range | −2.000 to 19.999 |
| pH Resolution | 0.1 / 0.01 / 0.001 |
| pH Accuracy | ±0.001 |
| ORP Range | ±1999.9 mV |
| ORP Resolution | 0.1 mV |
| Temperature Range | −5 to 105 °C |
| Temp Accuracy | ±0.1 °C |
| Data Storage | 1000 sets with timestamp |
| GLP Compliance | Yes |
| Connectivity | RS232 (bidirectional), optional USB |
| Enclosure Rating | IP54 |
| Certifications | CE, CSA, UL, TÜV, FCC Class A |
| Power | 4×AA batteries or universal AC adapter |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | D10P-82 |
| Price | Upon Request |
| Electrode | 9682BNWP Lead Ion-Selective Electrode |
| Measurement Range (Electrode) | 0.2–20,700 ppm Pb²⁺ |
| pH Range | 4–7 |
| Temperature Range | 0–80°C (continuous), 80–100°C (intermittent) |
| Repeatability | ±4% |
| Sample Type | Aqueous solutions |
| Electrode Dimensions | 110 mm length, 13 mm body diameter, 16 mm cap diameter |
| Cable Length | 1 m |
| Instrument Resolution (Ion Mode) | 1–3 significant digits |
| Ion Accuracy | ±0.1 mV or ±0.05% (whichever is greater) |
| Ion Units | ppm, mg/L, M, %, or unitless |
| Calibration Points | 2–6 |
| pH Range | −2.000 to 19.999 |
| pH Resolution | 0.1 / 0.01 / 0.001 |
| pH Accuracy | ±0.001 |
| ORP Range | ±1999.9 mV |
| ORP Resolution | 0.1 mV |
| Temperature Range | −5 to 105°C |
| Temp. Accuracy | ±0.1°C |
| Display | Dual-channel LCD |
| Inputs | Two BNC, two reference electrode, two MiniDIN (for ATC probes) |
| Method Storage | 20 methods |
| Password Protection | Yes |
| Data Storage | 1000 data sets with timestamp |
| GLP Compliance | Yes (audit trail, user ID, calibration history) |
| Connectivity | RS232 (bidirectional), optional USB cable |
| Enclosure Rating | IP54 |
| Certifications | CE, CSA, UL, TÜV, FCC Class A |
| Operating Environment | 5–45°C, 5–85% RH (non-condensing) |
| Power | 4×AA batteries or universal AC adapter |
| Dimensions | 9.4 × 17.0 × 22.4 cm (H×W×L) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Singapore |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Laboratory BOD Analyzer |
| Model | 310D-24A |
| Measurement Principle | Polarographic & Luminescent (RDO) Dissolved Oxygen Detection |
| DO Range (Polarographic) | 0–90 mg/L |
| DO Resolution (Polarographic) | 0.1 / 0.01 mg/L |
| DO Accuracy (Polarographic) | ±0.2 mg/L |
| DO Range (RDO) | 0–50 mg/L |
| DO Accuracy (RDO) | ±0.1 mg/L (0–8 mg/L), ±0.2 mg/L (8–20 mg/L), ±10% of reading (20–50 mg/L) |
| Saturation Range (Polarographic) | 0–600% |
| Saturation Range (RDO) | 0–500% |
| Saturation Accuracy | ±2% |
| Temperature Range | 0–50 °C |
| Temperature Accuracy | ±0.1 °C |
| Atmospheric Pressure Compensation | 450.0–850.0 mmHg |
| Salinity Compensation | 0–45 ppt (automatic with conductivity module or manual) |
| Calibration Modes | Saturated air/water, Winkler titration, zero-oxygen water |
| Data Storage | 2000 GLP-compliant entries |
| Interface | 9-pin mini-DIN DO probe port, RS232, USB |
| Power | AC adapter (100–240 V AC) or 4 × AA batteries |
| IP Rating | IP54 |
| Brand | Thermo Fisher |
|---|---|
| Origin | Singapore |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Portable |
| Measurement Principle | Polarographic & Luminescent (RDO) |
| DO Range | 0–90 mg/L (polarographic), 0–50 mg/L (RDO) |
| Accuracy | ±0.2 mg/L (polarographic), ±0.1–±0.2 mg/L + 10% (RDO) |
| Saturation Range | 0–600% (polarographic), 0–500% (RDO) |
| Temperature Range | 0–50 °C |
| Temp Accuracy | ±0.1 °C |
| Atmospheric Pressure Compensation | 450.0–850.0 mmHg |
| Salinity Correction | 0–45 ppt |
| Data Storage | 2000 datasets (GLP-compliant) |
| IP Rating | IP67 |
| Interface | 9-pin mini-DIN probe port, USB, RS232 |
| Power | 4 × AA batteries or AC adapter |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | VERSA STAR (VM-01 refers to base configuration) |
| Compliance | GLP, USP <645>, ASTM D1125, ISO 7888, ISO 5814, ISO 10523, FDA 21 CFR Part 11 (with optional audit trail software) |
| Data Storage | 2000 GLP-compliant entries |
| Connectivity | Dual USB + RS232 |
| Module Capacity | Up to 4 simultaneous modules |
| IP Rating | IP54 |
| Power | 90–260 V AC, 50–60 Hz |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Model | Orion™ 3106 COD |
| Instrument Type | Online Analyzer |
| Measurement Principle | Potassium Dichromate Digestion with Photometric Detection |
| Wavelength | 450 nm |
| Measurement Ranges | 20–200–800–2000 mg/L COD |
| Accuracy | ±5 mg/L (for values <50 mg/L) or ±10% (for values >50 mg/L) |
| Repeatability | ≤5% |
| Limit of Detection (LOD) | 4 mg/L |
| Cycle Time | 40 min per sample |
| Sample Throughput | 500 samples per batch |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | Orion™ 3106 COD |
| Instrument Type | Online Analyzer |
| Measurement Principle | Potassium Dichromate Oxidation Digestion (Online Mode) |
| Detection Wavelength | 450 nm |
| Measurement Ranges | 20–200–800–2000 mg/L (auto-ranging) |
| Accuracy | ±5 mg/L (for values <50 mg/L) or ±10% (for values >50 mg/L) |
| Repeatability | ≤5% RSD |
| Limit of Detection (LOD) | 4 mg/L |
| Cycle Time | 40 minutes per sample |
| Sample Throughput | Up to 500 samples per batch |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | pDR-1000AN |
| Measurement Principle | Optical Light Scattering (Forward Scatter at 50–90°) |
| Measured Parameters | PM₁₀, PM₂.₅ |
| Detection Range | 0.001–400 mg/m³ |
| Particle Size Response | 0.1–10 µm |
| Output | Analog Voltage & Digital Serial (RS-232), Optional Alarm Relay |
| Weight | 0.5 kg |
| Dimensions | Palm-sized (approx. 12.7 × 8.9 × 4.4 cm) |
| Power | AC Adapter or Optional Rechargeable Battery |
| Calibration Traceability | NIST-traceable gravimetric calibration using SAE test dust |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | RadEye AB100 |
| Instrument Category | Dose Rate / Contamination Meter |
| Form Factor | Portable |
| Detector Type | Zinc-Loaded Plastic Scintillator |
| Active Detection Area | 69 mm × 145 mm (10,005 mm²) |
| Effective Sensitivity Area | 2500 px² (≈ 100 cm² equivalent in operational context) |
| Window Thickness | 0.87 mg/cm² aluminum-coated polymer foil |
| Alpha Efficiency (²⁴¹Am) | 36% |
| Beta Efficiency (⁶⁰Co) | 25% |
| Beta Efficiency (⁹⁰Sr/⁹⁰Y) | 49% |
| Gamma Response (¹³⁷Cs) | ~40 cps per µSv/h |
| Battery Life | Up to 1000 hours on NiMH rechargeable pack |
| Compliance | Meets ANSI N42.33, IEC 60846-1, and ISO 7503-1 for surface contamination monitoring |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | RadEye B20 |
| Instrument Type | Portable Radiation Survey Meter |
| Radiation Types Detected | Alpha, Beta, Gamma, and X-ray |
| Detector Type | Thin-window Geiger-Müller (GM) Tube with 44 mm Active Diameter and Adjustable Window Thickness (1.8–20 mg/cm²) |
| Dose Rate Range (γ) | 0–2 mSv/h (RadEye B20) |
| Count Rate Range (Contamination) | 0–10 kcps (B20) |
| Energy Response (with γ energy window) | 17 keV – 3 MeV |
| 2π Detection Efficiency | ²⁴¹Am: 28%, ⁶⁰Co: 25%, ⁹⁰Sr/⁹⁰Y: 36%, ¹⁴C: 19% |
| Calibration Source | 9 g Lutetium Oxide (Lu₂O₃) reference source, activity density 50 Bq/g (1.4 nCi/g) |
| Alarm Modes | Audible, Visual (LED), and Vibratory |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | RadEye G-10 |
| Instrument Category | Dose Rate Meter |
| Form Factor | Portable |
| Radiation Types Measured | X-ray and Gamma (γ) |
| Detector Type | Energy-Compensated Geiger-Müller (GM) Tube |
| Measurement Range | 0.5 µSv/h to 100 mSv/h |
| Energy Response Range | 50 keV to 3 MeV |
| Sensitivity (¹³⁷Cs) | 1.7 cps per µSv/h |
| Compliance | ANSI N42.33-2021, NATO AEP-117 Ed.3 |
| Battery Life | Up to 600 hours on two AAA alkaline cells |
| Environmental Robustness | Vibration-resistant housing, IP65-rated enclosure |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | RadEye G-EX |
| Instrument Category | Dose Rate Meter |
| Form Factor | Portable |
| Radiation Types Detected | Alpha, Beta, Gamma, Neutron |
| Measurement Range | 0.5 μSv/h – 100 mSv/h |
| Sensitivity (Cs-137, 662 keV) | ~1.7 cps/μSv/h |
| Ingress Protection | IP65 |
| ATEX Certification | II 2G Ex ia IIB T4, IBExU 10ATEX 1096 |
| Weight | 160 g |
| Display | Backlit High-Contrast LCD |
| Alarm Modes | Dual Adjustable Thresholds (Dose & Dose Rate) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Portable Radiation Survey Meter |
| Instrument Category | Gamma and Neutron Dose Rate Meter |
| Model | RadEye GN |
| Detection Principle | Dual-channel scintillation detection (CsI:Tl for gamma, LiI(Eu) for thermal neutrons) |
| Gamma Energy Range | 30 keV–1.3 MeV |
| Neutron Sensitivity | Cf-252 source, 4.3 cps per 20,000 n/s |
| Gamma Dose Rate Range (H*(10), energy-compensated) | 0.01 μSv/h–250 μSv/h |
| Gamma Dose Rate Energy Compensation Range | 45 keV–1.3 MeV |
| Neutron Counting Rate | 0.1–1000 cps |
| Dimensions | 96 mm × 61 mm × 31 mm |
| Weight | 160 g |
| Gamma Efficiency | Am-241: 900 cps/(μSv/h), Cs-137: 130 cps/(μSv/h), Co-60: 60 cps/(μSv/h) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | RadEye HEC |
| Instrument Category | Dose Rate / Activity Meter |
| Form Factor | Portable |
| Measured Radiation Types | Alpha and Beta Emitters |
| Detector Type | Scintillation Detector (Lu₂O₃-based) |
| Counting Range | Alpha: 1–10,000 cps |
| Beta | 1–100,000 cps |
| Background | Alpha <2 cpm, Beta <70 cpm (under 0.25 µSv/h gamma background) |
| Detector Diameter | 5 cm |
| Detection Efficiency (2π geometry, 50 mm source) | Pu-239 >85%, Am-241 >75%, Tc-99 >45%, Sr/Y-90 >70%, C-14 >20% |
| Sample Chamber Dimensions | 51.6 mm × 9.6 mm |
| Adjustable Sample Height | 3.2–7.9 mm |
| Data Storage | 250 system events (alarms/errors/parameter changes), 4500 full sample records |
| Calibration & Decay Correction | Built-in automated routines |
| Interface | Serial and USB |
| Regulatory Compliance | CE Marked |
| Internal Check Source | 9 g lutetium oxide (¹⁷⁶Lu) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | RadEye NBR |
| Instrument Category | Radiation Survey Meter / Dose Rate Meter |
| Form Factor | Portable |
| Detection Target | Trace Artificial Gamma Emitters |
| Detector Type | Multi-Function NBR Probe (FHZ 674) |
| Measurement Range | 0.01 µSv/h – 100 µSv/h |
| Sensitivity | >1500 cps per µSv/h (at 30 keV) |
| Operating Temperature | −20 °C to +50 °C |
| Dimensions (RadEye SX) | 110 mm × 67 mm × 62 mm |
| Weight (RadEye SX only) | ~160 g (with 2×AA batteries and rubber boot) |
| Weight (FHZ 674 probe + SX) | ~2.8 kg (excluding shoulder strap) |
| Battery Life | ~150 h (with FHZ 674 probe, part #4250693) |
| Data Storage | 1500 measurement records + 250 operation logs |
| Alarm | Dual configurable thresholds (count rate / dose rate), audible alarm ≥80 dB at 30 cm |
| Probe Cable | RG58, up to 1.5 m, MHV connector |
| High Voltage Output | 100–1400 V, 2 MΩ load |
| Compatible Probes | 16 selectable probe types (configurable via HV, calibration factor, dead-time correction, overload threshold, and range) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | RadEye NL |
| Instrument Category | Neutron Dose Rate Meter |
| Form Factor | Portable |
| Detector Type | Pressurized He-3 Proportional Counter (2.5 bar) |
| Measurement Range | <0.2 cps (in presence of 10 mSv/h Cs-137 gamma field) |
| Neutron Sensitivity | −0.15 cps per μSv/h (calibrated to Cf-252 neutron source) |
| Background Count Rate | 0.0025 cps (at 300 m elevation) |
| Gamma Rejection Ratio | <0.2 cps for 10 mSv/h Cs-137 |
| Units Displayed | Counts per second (cps) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Portable Personal Radiation Detector (PRD) |
| Detector Type | NaI(Tl) Scintillation Crystal |
| Measurement Principle | Gamma Photon Detection via Scintillation & Pulse Height Analysis |
| Dose Rate Range | 0.01 µSv/h – 250 µSv/h (PRD mode) |
| Extended Range (PRD-ER) | 0.01 µSv/h – 100 mSv/h |
| Energy Response Range | 60 keV – 1.3 MeV |
| Sensitivity | 150 cps/(µSv/h) for ¹³⁷Cs |
| Data Storage Capacity | 1600 dose rate readings with timestamps |
| Ingress Protection Rating | IP65 |
| Operating Temperature | –10 °C to +50 °C |
| Battery Life | Up to 1,000 hours (typical alkaline battery operation) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Portable Radiation Survey Meter / Dose Rate Meter |
| Detector Type | NaI(Tl), GM Tube, ZnS(Ag)-Plastic Scintillator, He-3 Proportional Counter |
| Radiation Types Detected | Alpha (α), Beta (β), Gamma (γ), X-ray, Neutron |
| Measurement Modes | Dose rate (μSv/h, mR/h), Count rate (cps), Surface contamination (Bq, Bq/cm², dpm), Spectral identification (RadEye GN+/NBR) |
| Dose Rate Range (RadEye PRD) | 0.01 μSv/h – 250 μSv/h |
| Sensitivity (Cs-137, RadEye PRD) | 150 cps per 1 μSv/h |
| Energy Response | 30 keV – 4 MeV (model-dependent) |
| Compliance | IEC 62533, IEC 62401, ANSI N42.32, ATEX II 2G Ex ia IIB T4 (G-10-Ex) |
| Operating Environment | Field-deployable, battery-powered, ruggedized for industrial, emergency response, and regulatory use |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Portable Radiation Spectrometer |
| Model | RIIDEye |
| Detector Types | NaI(Tl), LaBr₃(Ce), LiI(Eu), CLYC (Cs₂LiYCl₆:Ce) |
| Energy Range | 20 keV – 3 MeV |
| Dose Rate Range | 10 nSv/h – 0.1 Sv/h |
| Total Dose Range | 100 nSv – 1 Sv |
| Sensitivity | 3000 cps/μSv/h |
| ADC Resolution | 14-bit fast baseline restoration |
| Spectral Stabilization | K-40-based automatic temperature-compensated stabilization |
| Nuclide Library | ANSI N42.34-compliant library of 88 isotopes (expandable to 125), including ITRAP/IAEA, medical, industrial, SNM, and user-defined nuclides |
| Identification Algorithms | QCC™ Quantitative Composite Comparison and Hysteresis™ pattern-matching technologies |
| Display | 3.5″ color LCD (320×240, 32k colors) |
| Interface | 7-key single-finger keypad, Ethernet or RS-232 |
| Data Storage | ≥10,000 spectra with timestamp, GPS (optional), and full metadata |
| Power | Rechargeable battery or AA cells |
| Environmental Rating | IP67-rated ruggedized enclosure (RIIDEyeX) |
| Compliance | ANSI N42.34, IEC 62327, IEEE 309, MIL-STD-810G |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | SAM12 |
| Instrument Category | Dose Rate / Contamination Meter |
| Instrument Form Factor | Portable |
| Detection Target | Gamma-emitting Radionuclides |
| Detector Technology | Co-60–Optimized Scintillation Detection with NBR (Natural Background Rejection) Algorithm |
| Measurement Scope | Discrimination of Artificial vs. Natural Gamma Radioactivity |
| Performance Context | High-reliability detection under elevated natural background radiation conditions |
| Sensitivity | Enhanced for low-level gamma contamination screening |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Import Status | Imported |
| Model | 096019 |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | 17i |
| Instrument Type | Online Gas Analyzer |
| Detection Principle | Chemiluminescence (NO–O₃ Reaction) |
| Measurement Modes | NO, NOₓ, Nₜ |
| NH₃ Quantification Method | Stainless-Steel Catalytic Converter-Based Conversion to NO |
| Output Signals | Analog (0–10 V / 4–20 mA), Digital (Ethernet) |
| Data Storage | Internal Flash Memory |
| Remote Access | Yes, via Local Area Network |
| Compliance | Designed for EPA Reference Method Compliant Monitoring (e.g., EQOA-0038), Supports GLP/GMP Audit Trail Requirements (via optional software logging) |
| Operating Environment | Indoor/Outdoor Enclosure Rated NEMA 4X |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Dimensions | 48.3 cm W × 17.8 cm H × 55.9 cm D (19″ Rack Mountable) |
| Weight | 22.7 kg |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | 17i NH₃ Analyzer |
| Instrument Type | Online Gas Analyzer |
| Detection Principle | Chemiluminescence Detection (CLD) |
| Measurement Range | 0–50, 100, 200, 500, 1,000, 2,000, 10,000, 20,000 ppb |
| Alternate Units | 0–100, 200, 500, 1,000, 2,000, 5,000, 10,000, 20,000, 30,000 µg/m³ |
| Zero Noise | 0.5 ppb RMS (120-s averaging time) |
| Limit of Detection (LOD) | 1 ppb |
| Zero Drift (24 h) | ≤1 ppb |
| Span Drift (30 days) | ≤1% of full scale |
| Analog Outputs | Independent isolated 0–10 V or 4–20 mA outputs for NO, NO₂, NH₃, and NOₓ |
| Diagnostic Capability | Real-time status monitoring, remote performance diagnostics, built-in fault detection and logging |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | 17i |
| Instrument Type | Online Gas Analyzer |
| Detection Principle | Chemiluminescence (NO + O₃ → NO₂* + hν) with Catalytic Conversion for NH₃ and NO₂ |
| Measurement Modes | NO, NOₓ, Nₜ |
| Output Signals | Analog (0–10 V / 4–20 mA), Digital (Ethernet), RS-232/RS-485 |
| Range Options | 0–50 to 0–20,000 ppb |
| Zero Noise | 0.5 ppb RMS (120 s averaging) |
| LOD | 1 ppb |
| Zero Drift (24 h) | ≤1 ppb |
| Span Drift (30 days) | ≤1% FS |