| Brand | EDC |
|---|---|
| Origin | USA |
| Model | VDM-7500 |
| Measurement Principle | Video Imaging + Gravimetric Reference Correlation |
| Safety Rating | Non-Explosive (Non-Intrinsically Safe) |
| Measurement Range | 0.01–200 mg/m³ |
| Resolution | 0.01 mg/m³ |
| Accuracy | ±10% (vs. NIOSH-approved gravimetric filter method) |
| Particle Size Detection Range | 0.1–100 µm |
| Flow Rate | 1.0–3.3 L/min |
| Data Logging Capacity | 21,500 points |
| Sampling Interval | 1 s to 10 min |
| Operating Temperature | 0–50 °C |
| Battery Life | >8 h (NiMH rechargeable) |
| Dimensions (Main Unit) | 13.7 × 8.4 × 6.8 cm |
| Weight | 0.68 kg |
| Brand | -- |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | EDGE |
| Pricing | Upon Request |
| Brand | Edinburgh Instruments |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrumentation |
| Model | Boxed Gascard |
| Operating Voltage Range | 7–30 V DC |
| Communication Interface | RS232 (optional) |
| Onboard Pressure Compensation Range | 800–1150 mbar |
| Infrared Source | Field-replaceable |
| Temperature Compensation | Wide-range, integrated |
| Brand | Edinburgh Instruments |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Gascard NG |
| Operating Range | 0–5000 ppm to 0–100% (gas-dependent) |
| Pressure Compensation | 800–1150 mbar |
| Supply Voltage | 7–30 V DC |
| Communication Interface | RS232 |
| Light Source | Field-replaceable infrared source |
| Display Support | 4-bit and 128 × 64 pixel graphical LCD via expansion port |
| Target Gases | CO, CO₂, CH₄, N₂O (customizable) |
| Brand | Edinburgh Instruments |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | Guardian NG |
| Price Range | USD 3,800 – 5,100 (FOB UK) |
| Brand | Edinburgh Instruments |
|---|---|
| Origin | United Kingdom |
| Model | Guardian Plus |
| Detection Principle | Non-Dispersive Infrared (NDIR) Spectroscopy |
| Measurable Gases | CO₂ (0–3000 ppm to 0–100% vol), CH₄ (0–5% to 0–100% vol) |
| Output Options | 4–20 mA, RS-232/RS-485, Modbus RTU/TCP |
| Enclosure Rating | IP65 |
| Operating Temperature | –10 °C to +50 °C |
| Power Supply | 24 VDC ±10% |
| Compliance | CE, UKCA, RoHS, EMC Directive 2014/30/EU |
| Calibration | Factory-calibrated with optional user-accessible zero/span adjustment |
| Frequency Range | 3 kHz – 30 MHz |
|---|---|
| Electric Field Range | 0.02–1000 V/m |
| Magnetic Field Range | 0.6 mA/m – 300 A/m |
| Resolution Bandwidth | 1 kHz (min) |
| Dynamic Range | 80 dB |
| Battery Life | Up to 12 h (rechargeable Li-ion) |
| Probe Dimensions | 92 × 92 × 109 mm |
| Compliance | Designed for IEC 61786-1, IEEE C95.3, and EN 50492 assessment workflows |
| Brand | Eigenbrodt |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ANES 220 |
| Pricing | Available Upon Request |
| Brand | Eigenbrodt |
|---|---|
| Origin | Germany |
| Model | BUS125/KE |
| Collection Area | 500 cm² |
| Power Supply | 230 VAC, 50 Hz, max. 100 VA |
| Funnel Heating | 12 VDC, 50 W |
| Sample Heating | 12 VDC, 40 W |
| Sample Cooling | 12 VDC, 40 W |
| Operating Height | 1500 mm |
| Dimensions | H 1500 mm × Ø 315 mm |
| Weight | 35 kg |
| Funnel Material | DURAN® borosilicate glass |
| Temperature Control | Peltier-based heating/cooling, sample maintained at ~5 °C |
| Enclosure | Thick-walled PVC housing with lockable door |
| Compliance | VDI 3870, LAWA guidelines |
| Brand | Eigenbrodt |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrumentation |
| Model | Optional Module Set for UNS130/NSA181/NSA181-K/NMO191 Systems |
| Pricing | Upon Request |
| Brand | Eigenbrodt |
|---|---|
| Origin | Germany |
| Model | LAM630 / LAM630R |
| Operating Temperature Range | −30 °C to +70 °C |
| Enclosure Height | 215 mm |
| Top Diameter | 290 mm |
| Base Diameter | 250 mm |
| Total Assembled Height (with mounting post) | 440 mm |
| Fan Supply | 12 V DC, 100 mA |
| Material | UV-stabilized ABS layers + high-strength opal PMMA top shield |
| Weight (uncalibrated) | 3.0 kg |
| Weight (calibrated version) | 3.3 kg |
| Sensor Capacity | 1–4 integrated probes (temperature, relative humidity, barometric pressure, CO₂, solar radiation, precipitation detection) |
| Brand | Eigenbrodt |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | NES 210 |
| Pricing | Available Upon Request |
| Brand | Eigenbrodt |
|---|---|
| Origin | Germany |
| Model | NILU SF 1 |
| Construction Material | HD-polyethylene |
| Support Frame | Stainless Steel |
| Collection Aperture Diameter | 200 mm (ISO-compliant) |
| Total Height | 400 mm (ISO-compliant) |
| Adjustable Mounting Height | 1.7–2.6 m above ground level (incl. ISO reference height) |
| Standard Kit | Sampler body with lid, stainless steel retaining ring, nested basket, ground stakes |
| Optional Accessories | Telescopic ground anchors (for rocky or paved surfaces), individual component replacement parts |
| Brand | Eigenbrodt |
|---|---|
| Country of Origin | Germany |
| Model | NMO191 |
| Measurement Parameters | pH, Electrical Conductivity, Precipitation Intensity, Cumulative Precipitation Volume |
| Temperature-Controlled Measurement Chamber | 4–7 °C (active refrigeration with auto-defrost) |
| Collection Area | 500 cm² |
| Compliance | VDI 3870 (German Association of Engineers) |
| Enclosure | Double-walled insulated PVC housing |
| Sensor Interface | RS 85 precipitation sensor (standard), optional IRSS 88 or NRS 80 |
| Control System | SIEMENS® LOGO® programmable logic modules |
| Sample Handling Options | Single-bottle (5 L HD-PE), 8-day sequential (8 × 750 mL or 8 × 1000 mL HD-PE), with bottom-heated bottle tray |
| Materials | Chemically inert components throughout (HD-PE, borosilicate glass optional), corrosion-resistant fittings |
| Cooling System | FCKW-free plate-evaporator refrigeration unit with forced ventilation and particulate filter |
| Brand | Eigenbrodt |
|---|---|
| Origin | Germany |
| Model | NSA 161/R T-N |
| Collection Area | 5000 cm² |
| Power Supply | 230 VAC / 50 Hz, max. 400 VA |
| Heating System | 2 × 200 W convection heaters, thermostatically controlled |
| Operating Height | 1500 mm (requires base) |
| Enclosure Dimensions | H 1250 mm × Ø 900 mm |
| Weight | Sampler 68 kg, Base 14 kg |
| Construction | Double-walled cylindrical polyethylene housing with mineral wool insulation |
| Funnel | Open-top PE funnel with integrated sharp-edged rim for total deposition sampling |
| Sample Containers | 4 × 20 L HD-PE bottles |
| Temperature Control | Maintains internal chamber above 0 °C during winter to prevent freezing and melt snow |
| Overflow System | Integrated bypass for excess precipitation after all bottles are filled |
| Volume Indication | Calibrated scale per bottle |
| Brand | Eigenbrodt |
|---|---|
| Country of Origin | Germany |
| Model | NSA 181 |
| Sampling Configurations | E-type (single 5–10 L HD-PE bottle), D-type (dual-week, two 5 L HD-PE bottles), S-type (8-day sequential, eight 1 L HD-PE bottles) |
| Heating | Bottom-heated sample bottles (D/S types) or heated collection chamber (E-type) |
| Control System | Siemens LOGO! programmable logic controller |
| Power Backup | Integrated rechargeable battery supporting ≥24 h operation during mains failure |
| Enclosure | Double-insulated PVC housing with automatic ventilation |
| Collection Area | 500 cm² polyethylene funnel compliant with VDI 3870 |
| Sensor Interface | RS 485-compatible precipitation sensor (e.g., RS 85, NRS 80, IRSS 88) |
| Materials | Chemically inert HD-PE, DURAN® borosilicate glass, or PTFE components |
| Data Logging | Integrated LCD timer + digital data recording system |
| Structural Base | Galvanized steel mounting frame |
| Compliance | Designed per VDI 3870 |
| Brand | Eigenbrodt |
|---|---|
| Origin | Germany |
| Model | NSA181 |
| Application | Mercury (Hg) speciation sampling, wet/dry deposition monitoring, dual- or tri-weekly fractionated collection |
| Cooling | Continuous refrigerated sample chamber (4 °C) |
| Sample Allocation | Motorized multi-bottle distributor (3-position standard) |
| Material Compatibility | Borosilicate glass (DURAN®) and PTFE-wetted surfaces |
| Environmental Certification | Compliant with EN 14211, ISO 10473, and EU Directive 2004/107/EC for heavy metal deposition monitoring |
| Data Interface | RS-485, analog outputs, GSM-enabled telemetry (optional) |
| Power Options | 230 V AC / 12 V DC auto-switching |
| Optional Accessories | IRSS 88 infrared precipitation sensor, snow cover kit, magnetic isolation valve, GLP-compliant audit trail logging (via optional software module) |
| Brand | Eigenbrodt |
|---|---|
| Country of Origin | Germany |
| Model | NSA181/K-TYPE |
| Sampling Configurations | E-type (single 5–10 L bottle), D-type (dual 5 L weekly bottles), S-type (eight 1 L daily bottles) |
| Collection Area | 500 cm² |
| Temperature Control Range | 3–10 °C (standard operating setpoint: 4–6 °C) |
| Cooling Medium | R134a (CFC-free) |
| Sensor Interface | RS 85 precipitation sensor (standard) |
| Enclosure | Double-walled insulated PVC cabinet |
| Materials | Chemically inert components (HD-PE, DURAN® borosilicate glass, quartz options available) |
| Compliance | VDI 3870-compliant funnel geometry and material specification |
| Control System | SIEMENS® LOGO! programmable logic controller |
| Brand | Eigenbrodt |
|---|---|
| Origin | Germany |
| Model | RS85 / RS85OP / NRS80 |
| Power Supply | 24 V DC/AC (RS85/RS85OP: max. 20 W |
| NRS80 | max. 700 mA, half-wave rectified) |
| Output | Dry-contact relay (NO/NC), 100 V DC / 250 V AC, 5 A, 1250 VA |
| Sensing Area | RS85/RS85OP ≈ 60 cm² |
| Activation | Instant on-rain detection |
| Deactivation Delay | 0–270 s adjustable in 30 s increments |
| Heating | Dual-stage proportional electronic heating (24 V DC) |
| Enclosure Rating | IP65 |
| Dimensions | RS85/RS85OP 83 × 83 × 85 mm, 700 g |
| Compliance | Designed for continuous outdoor deployment in meteorological and environmental monitoring networks |
| Brand | Eigenbrodt |
|---|---|
| Origin | Germany |
| Model | UNS 130D/E |
| Collection Area | 500 cm² |
| Precipitation Sensor | RS 85 (binary yes/no output) |
| Power Supply | 230 VAC, 50 Hz, max. 250 VA |
| DC Heater Supply | 24 V DC, 2 × 30 W |
| Funnel Cover Drive Motor | 24 V DC, 50 W |
| Overall Height (with base) | 1500 mm |
| Dimensions (H × L × W) | 800 × 470 × 350 mm |
| Sampler Weight | 46 kg |
| Base Weight | 17 kg |
| Standard Configuration | Thick-walled PVC housing, HD-PE funnel, 5 L HD-PE sample bottle, lockable aluminum control cabinet with electronics and drive unit, thermostatically controlled heating system, RS 85 precipitation sensor |
| Brand | Eijkelkamp |
|---|---|
| Origin | Netherlands |
| Model | 01.11.SE |
| Weight | 29 kg |
| Max Sampling Depth | 5 m |
| Auger Diameter | 7 cm |
| Connection Type | Pin-lock coupling |
| Sample Type | Disturbed (non-intact) soil |
| Handle | Ergonomic reversible rotary handle |
| Included Augers | 4× Edelman augers (for clay, sand, coarse sand, and mixed soils), 1× Riverside auger, 1× stony-soil auger, 1× spiral auger, 1× semi-circular gouge auger |
| Accessories | Fiberglass multi-purpose probe with audible depth indicator, calibrated measuring tape with acoustic feedback, aluminum transport case, portable backpack, maintenance tools |
| Brand | Eijkelkamp |
|---|---|
| Origin | Netherlands |
| Model | 01.11.SO |
| Weight | 26 kg |
| Max Sampling Depth | 5 m (extendable to 8–10 m with extension rods) |
| Auger Bit Diameter | 7 cm |
| Connection Type | Pin-lock coupling |
| Sample Types | Undisturbed and disturbed soil cores |
| Core Components | Four Edelman augers (clay, sand, gravel, composite), Riverside auger, gravel auger, spiral auger, piston sampler, semi-circular gouge auger |
| Accessories | Fiberglass multi-purpose probe rod, depth gauge tape, push-pull handle, maintenance tools, field logbook, aluminum transport case |
| Weight | 13 kg |
|---|---|
| Sampling Depth | 1 m |
| Sampling Diameter | 2 cm |
| Sample Type | Intact Cylindrical Soil Core |
| Core Diameter (Internal) | 18 mm |
| Rod Length | 100 cm |
| Includes | Purolhauer-type cylindrical auger, 1-m nylon mallet, mechanical lever extraction system, rugged transport case |
| Compliance | Designed for ASTM D1586 (Standard Test Method for Penetration Testing and Split-Barrel Sampling of Soils), ISO 22027 (Soil Quality — Sampling), and EU Soil Thematic Strategy field protocols |
| Brand | Eijkelkamp |
|---|---|
| Origin | Netherlands |
| Model | 04.02.SC |
| Weight | 15 kg |
| Maximum Sampling Depth | 5 m |
| Core Diameter | 3 cm |
| Sample Length per Insertion | 100 cm |
| Sampling Type | Intact Cylindrical Soil Core |
| Connection Type | Threaded Coupling |
| Configuration | Single-tube, manual operation |
| Brand | Eijkelkamp |
|---|---|
| Model | 04.15.SB |
| Sampling Depth | 7 m |
| Core Diameter | 37 mm |
| Core Length | 22 cm |
| Construction | Stainless Steel |
| Liner Material | Disposable/Reusable Polyethylene Sleeve |
| Connection Type | Threaded Coupling |
| Included Accessories | Edelman Auger, Riverside Auger, T-Handle, Extension Rods, Push-Pull Handle, Sampling Tubes with Sample Cylinders, Liners, Maintenance Tools, Aluminum Transport Case |
| Origin | Netherlands |
| Brand | Eijkelkamp |
|---|---|
| Origin | Netherlands |
| Model | 04.16 |
| Sampling Depth | 5 m |
| Sampling Diameter | 40 mm (outer) × 38 mm (inner) |
| Sampling Length | 200 mm |
| Sample Volume | 226 mL |
| Material | Full stainless steel (316 SS contact surfaces) |
| Compliance | NEN 5743 |
| Core Configuration | Edelman-type pre-augering drill + vacuum-assisted stainless steel coring tube with valve-sealed base, removable liner, insulating plate, bottom cap, sample extruder, and maintenance tools |
| Transport Case | Anodized aluminum carrying case |
| Brand | Eijkelkamp |
|---|---|
| Origin | Netherlands |
| Model | 05.02 |
| Weight | 27 kg |
| Max Sampling Depth | 2 m |
| Sample Diameter | 8 cm |
| Sample Length | 15 cm |
| Connection Type | Threaded Coupling |
| Sampling Type | Intact Soil Core |
| Standard Drills Included | Edelman Drill (10 cm Ø), Riverside Drill |
| Accessories | Extension Rods, Fiberglass Multi-Purpose Probe, Maintenance Tools, Field Logbook, Scraper, Aluminum Transport Case |
| Brand | Eijkelkamp |
|---|---|
| Origin | Netherlands |
| Model | 05.07 |
| Weight | 84 kg |
| Maximum Sampling Depth | 1 m |
| Core Dimensions | 100 cm length × 93 mm diameter |
| Power Source | Gasoline-driven percussion hammer |
| Core Retrieval | Split-barrel, hinged side-wall design |
| Standard Accessories | Percussion hammer, split-core barrel with hinge mechanism, extension rods, lever-assisted lifting device, 10 cm Edelman auger, T-handle, cutting head extraction hook, scraper, brush, gloves, maintenance kit, and sample storage components |
| Soil Compatibility | Suitable for cohesive, granular, and moderately compacted soils |
| Brand | Eijkelkamp |
|---|---|
| Origin | Netherlands |
| Model | 07.53.SA |
| Sampling Depth | 2 m |
| Sample Dimensions | Ø53 × 50 mm (H), Volume: 100 cm³ |
| Connection Type | Pin-lock coupling |
| Ring Holder Type | Open-frame design |
| Standard Kit Includes | 1 open-frame ring holder, 1 Edelman auger, 1 Riverside auger, ergonomic handle, extension rods, 24 stainless steel sampling rings (Ø53 mm), accessories, and carrying backpack |
| Brand | Eijkelkamp |
|---|---|
| Model | 08.13 |
| Power Supply | 90–264 VAC input (worldwide compatible) with interchangeable plugs |
| Motor | 12/24 VDC |
| Sieve Assembly | 8-position aluminum sieve holder with standardized 39 × 39 mm sieves (0.250 mm aperture, 10.2 cm² active area) |
| Sample Container | Aluminum canisters (62.5 × 44 mm) |
| Operating Principle | Wet-sieving under controlled vertical oscillation |
| Compliance | Designed for ASTM D6913, ISO 10930, and USDA-NRCS soil structure protocols |