| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Domestic Production | Yes |
| Model | MODEL2030 |
| Price | USD 3,950 (FOB) |
| Measurement Principle | Laser Backscatter Photometry |
| Explosion-Proof Rating | Ex d IIB T4 Gb |
| Measurement Range | 0.01–5000 mg/m³ (standard) |
| Resolution | 0.01 mg/m³ |
| Accuracy | ±1% of reading |
| Relative Error | ±2% FS |
| Operating Temperature | −40 °C to +65 °C |
| Humidity Range | 0–100% RH (non-condensing) |
| Max. Flue Gas Temperature | 300 °C (custom high-temp probe available) |
| Output Signal | 4–20 mA (max. load 500 Ω) |
| Power Supply | DC 16–24 V ±10% |
| Power Consumption | ≤3 W (typical), ≤5 W (max.) |
| Dimensions | 160 × 250 mm (H × D) |
| Weight | 4 kg |
| Flue Diameter Compatibility | 1–15 m |
| Minimum Detectable Concentration | 2 mg/m³ |
| Installation | Single-ended, tool-free mounting |
| Origin | Italy |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 8869 |
| Pricing | Available Upon Request |
| Measurement Principle | Non-Dispersive Infrared (NDIR) |
| Minimum Range | CO: 0–10 ppm, CO₂: 0–5 ppm |
| Certifications | CE, EN 50081-1, EN 50082-2 |
| Enclosure Rating | IP65 |
| Weight | ~32 kg |
| Power Supply | 220 VAC, 48–63 Hz, 35 W |
| Sample Pressure (Flexible Tubing) | 600–1500 hPa (absolute) |
| (Rigid Tubing) | 500–1500 hPa (absolute) |
| Purge Gas Pressure | <165 hPa (gauge), short-term >250 hPa (gauge) |
| Sample Flow Rate | 0.3–1.5 L/min |
| Sample Temperature | 0–50 °C (standard), 0–80 °C (with optional heater) |
| Sample Humidity | <90% RH |
| Warm-up Time | 2 hours |
| Response Time (T₉₀) | 5 s |
| Damping Time | 0–100 s adjustable |
| Dead Time | 0.5–2.5 s |
| Internal Signal Processing Time | <1 s |
| Output Stability | ±0.1% to ±1% of minimum range |
| Zero Drift | <1% of minimum range per month |
| Span Drift | <1% of full scale per month |
| Repeatability | 0.1–1% of full scale |
| Linearity Error | <0.5% FS |
| Analog Inputs | 2 × 0/2/4–20 mA (cross-interference compensation) |
| Digital Inputs | 6 × 24 V DC, floating |
| Relay Outputs | 6 × 24 V AC/DC, 1 A, floating |
| Communication Interface | RS-485 |
| Operating Ambient Temperature | 5–45 °C |
| Storage/Transport Temperature | −30–+70 °C |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | PM2.5 |
| Price Range | USD 14,000–21,000 |
| Measurement Principle | Laser Light Scattering |
| Measured Parameters | PM1.0, PM2.5, PM5, PM10, TSP |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | 1500A |
| Instrument Type | Laboratory Benchtop Analyzer |
| Power Supply | 220 V AC, 50 Hz |
| Optical Source | Laser Diode |
| Detection Principle | Laser Light Attenuation / Absorption |
| Particle Size Range | 2–400 µm |
| Number of Adjustable Size Channels | 8 |
| Minimum Detectable Size | 2 µm |
| Resolution | ≤9% @ 2 µm |
| Signal-to-Noise Ratio | 3:1 |
| Counting Efficiency | ≥50% @ 1 µm |
| Maximum Particle Concentration | 18,000 counts/mL |
| Coincidence Loss (at max concentration) | 10% |
| Flow Rate | 60 mL/min (controlled via overflow tube & hydraulic pressure) |
| Flow Accuracy | ≤2% |
| Sensor MTBF | 60,000–80,000 hours |
| Communication Interface | RS-485 (4-wire Modbus), optional 4–20 mA output |
| Baud Rate | 9600 bit/s |
| Data Modes | Cumulative or Time-Segmented |
| Maximum Display Value | 9,999,999 (cumulative count) |
| Sample Path Flushing | Semi-Automatic |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 740 |
| Pricing | Available Upon Request |
| Origin | United Kingdom |
|---|---|
| Distribution Model | Authorized Distributor |
| Import Status | Imported |
| Model | 715 |
| Pricing | Upon Request |
| Weight | 1.2 kg |
| Dimensions | 280 × 230 × 130 mm |
| Enclosure Rating | IP54 (main unit), IP68 (probe) |
| Cable Diameter | 5 mm |
| Standard Cable Length | 10 m (max. 15 m) |
| Operating Temperature | −20–60 °C (unit), 0–40 °C (probe) |
| Storage Temperature | −20–60 °C (unit), 0–40 °C (probe) |
| Power Supply | 9 V PP9 battery (typical lifespan: 3 months) |
| Response Time | 0.5 s |
| Interface Detection Accuracy | ±1 cm |
| Resolution | 1 cm (marked at 1 m intervals) |
| Measurement Principle | Near-infrared light scattering (960 nm) |
| Probe Options | IR100 (0–200 mg/L, 100 mm sensing gap), IR40 (0–1,500 mg/L, 40 mm), IR15 (0–10,000 mg/L, 15 mm), IR8 (0–30,000 mg/L, 8 mm) |
| Output | Audible tone (short in water, long in sludge), LED indicator, no analog/digital output |
| Brand | Not specified |
|---|---|
| Origin | South Korea |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | ECT400/D052 |
| Pricing | Upon Request |
| Frequency | 450 kHz (ECT400) / 50 kHz & 200 kHz dual-frequency (D052) / 30 kHz & 200 kHz dual-frequency (D032) |
| Beam Width | 5° (ECT400) / 27° & 7° (50/200 kHz, D052) / 26° & 5° (30/200 kHz, D032) |
| Depth Range | 0.15–100 m (standard), up to 1000 m (customizable) |
| Vertical Resolution | 1 mm |
| Temperature Sensor Accuracy | ±0.1 °C |
| Tilt Sensor | Optional dual-axis (roll & pitch), ±90° range, 0.1° resolution |
| Net Weight / Gross Weight | 275 g / 1.6 kg (ECT400), 460 g / 2.7 kg (D052), 740 g / 4.2 kg (D032) |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Domestic Production | Yes |
| Model | SQC-1000 |
| Pricing | Available Upon Request |
| Flow Range Options | 0.1–1.5 L/min, 0.1–2.0 L/min, or 0.1–3.0 L/min |
| Flow Accuracy | ≤ ±5% |
| Timing Accuracy | ≤ ±1% |
| Maximum Negative Pressure | ≥25 kPa |
| Power Supply | 10 V DC (rechargeable Ni-Cd battery) / 220 V AC, 50 Hz |
| Operating Temperature | –10 to +45 °C |
| Relative Humidity | ≤85% RH |
| Weight | ~2.0 kg |
| Brand | AMAE |
|---|---|
| Origin | Guangdong, China |
| Model | EM-2068E |
| Sampling Methods | Filter Gravimetry (TSP/PM₁₀/PM₂.₅), Absorption Solution Collection, Sorbent Tube Enrichment |
| Measured Parameters | TSP, PM₁₀, PM₂.₅, SO₂, NOₓ, VOCs, Halogenated Hydrocarbons, Aldehydes/Ketones |
| Particulate Flow Range | 10–120 L/min |
| Dual High-Flow Gas Channels | 100–1500 mL/min |
| Dual Low-Flow Gas Channels | 10–200 mL/min |
| Flow Stability | ±5% |
| Flow Resolution | 0.1 L/min (particulate), 1 mL/min (gas) |
| Power Supply | Internal Rechargeable DC Battery (6–8 h at nominal flow) |
| Weight | 4.5 kg (including thermoelectric temperature control module) |
| Brand | Vientiane Environment |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | WX-Q2 |
| Price | USD 12,300 (FOB) |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ENH-1000 |
| Price | USD 795 (FOB) |
| Measurement Range | 0–2000 ppb |
| Accuracy | ±5 ppb |
| Power Supply | DC 6 V (4 × AA batteries) |
| Dimensions | 40 mm (W) × 195 mm (H) × 40 mm (D) |
| Weight | 135 g |
| Electrode Protection Solution | Included (2 vials) |
| Accessories | Waterproof O-rings (2), Electrode Cleaning Paper, Carrying Case, User Manual |
| Brand | ENTECH |
|---|---|
| Model | CS1200E |
| Type | 24-Hour Constant-Flow, Ambient-Pressure Gas Samplers |
| Configuration | Single-Channel Passive Canister Sampling System |
| Flow Control | Sapphire Orifice + Precision Pressure Regulator |
| Calibration Traceability | NIST-Traceable McDaniel Controls Flow Meter |
| Surface Treatment | Electropolished Stainless Steel with Silonite™ Fused-Silica Coating (Optional, denoted by “S” suffix) |
| Operating Range | 1–168 hours (adjustable via interchangeable sapphire orifices) |
| Inlet Protection | Hydrophobic Cap with Particulate Filtration |
| Compliance | Designed for EPA TO-14A, TO-15, ASTM D5466, and ISO 16017-1 Compliant Sampling |
| Brand | Environ Lab |
|---|---|
| Origin | USA |
| Model | ENV-12 |
| Capacity | 12 sample vessels |
| Rotation Speed | 30 ± 2 rpm |
| Tumbling Angle | 30° ± 2° |
| Timer Range | 0.1–999.9 h |
| Vessel Volume | 1 L (standard HDPE or stainless-steel options) |
| Compliance | ASTM D3987, EPA Method 1311 (TCLP), EPA Method 1312 (SPLP), ISO 14669 |
| Brand | Envea |
|---|---|
| Origin | France |
| Model | MIR 9000P |
| Measurement Principle | Gas Filter Correlation – Non-Dispersive Infrared (GFC-NDIR) with Integrated Paramagnetic/O2 Sensor |
| Measured Gases | CO, CO₂, CH₄, N₂O, O₂ |
| Concentration Units | ppm and mg/m³ selectable |
| Compliance | CPA Certified (China Metrology Type Approval) |
| Environmental Operating Range | −10 °C to +50 °C |
| Data Storage | Internal SD card (USB expansion optional) |
| Connectivity | Bluetooth 4.2, RS232, optional 4–20 mA analog outputs |
| Power Supply | Rechargeable Li-ion battery (≥8 h continuous operation) |
| Enclosure Rating | IP65 |
| Weight | ≤6.2 kg |
| Brand | Envea |
|---|---|
| Origin | France |
| Model | MIR-FT/P |
| Measurement Principle | Fourier Transform Infrared Spectroscopy (FTIR) |
| Detectable Gases | HCl, NO, NO₂ (NOₓ), CO, CO₂, CH₄ (TOC), SO₂, HC, NH₃, HF, H₂O |
| Response Time | <60 s (gas-dependent) |
| Repeatability | ±2% FS |
| Interferometer Resolution | 8 cm⁻¹ |
| Multi-pass Cell Path Length | 5 m |
| Operating Temperature | +10 °C to +35 °C |
| Dimensions | 616 × 483 × 220 mm (L×W×H) |
| Weight | ~20 kg |
| Power Supply | 220 V ±15%, 50–60 Hz, 200 VA |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | ENVIdata |
| Pricing | Available Upon Request |
| Brand | Environ Lab |
|---|---|
| Origin | USA |
| Model | ChloroTech121A |
| Detection Principle | Dual-Channel UV-Induced Fluorescence |
| Weight | <500 g |
| Protection Rating | IP67 |
| Power Supply | 4 × AAA batteries (≥1000 measurements per set) |
| Calibration | Integrated reference module |
| Sample Format | Disposable cuvettes |
| Measurement Modes | Live chlorophyll a, Extracted chlorophyll a, Turbidity (any two simultaneously) |
| Compliance | Designed for field-deployable environmental monitoring per EPA Method 445.0 and ISO 10260:2021 |
| Brand | Environ Lab |
|---|---|
| Origin | USA |
| Model | Multipro |
| Instrument Type | Portable/Handheld Water Quality Analyzer |
| Measurable Parameters | Depth, Temperature, Turbidity, Dissolved Oxygen (DO), pH/ORP, Conductivity (Salinity, Total Dissolved Solids), Chlorophyll-a, Phycocyanin (Blue-Green Algae), Oil-in-Water, Ammonia-Nitrogen*, COD (UV254)* |
| IP Rating | IP67 |
| Maximum Submersion Depth | 250 m |
| Probe Interchangeability | User-replaceable in field without tools |
| Modular Architecture | Independent housing for battery compartment and electronics |
| Operating Modes | Standalone portable operation and fixed online deployment |
| Data Storage | Internal memory for autonomous field station operation |
| Sensor Capacity | Up to 7 simultaneous sensors |
| Housing Material | Polyoxymethylene (POM) and titanium alloy |
| Temperature Compensation | PT1000 sensor (±0.1 °C accuracy) across all compatible probes |
| Brand | Environ Lab |
|---|---|
| Origin | USA |
| Model | OilTech121 |
| Instrument Type | Portable |
| Measurement Principle | UV-Induced Fluorescence Spectrophotometry |
| Measurement Range | 0–1000 ppm and 50 ppb–50 ppm (dual-range) |
| Detection Limit | <5 ppb |
| Accuracy | ±5% of reading |
| Resolution | 1 ppb |
| Measurement Frequency | 60 tests/hour |
| Measurement Time | ≤5 seconds per test |
| Display | Backlit LCD |
| Operating Temperature | 5–40 °C |
| Auto Power-Off | After 3 minutes of inactivity |
| Dimensions | 195 × 100 × 70 mm |
| Weight | 500 g (including batteries) |
| Power Supply | 4 × AAA alkaline batteries (>1000 tests per set) |
| Enclosure Rating | IP67 |
| Compliance | EPA Method 1664A-compatible solvent usage (e.g., n-hexane), ASTM D7678 referenced |
| Sample Vessel | Disposable quartz-cuvette-style microcell (1.5 mL volume) |
| Brand | Environ Lab |
|---|---|
| Origin | USA |
| Model | TCLP |
| Agitator Speed | 30 ± 2 rpm |
| Vessel Capacity | 2.0 L (non-volatile) / 550 mL (volatile, zero-headspace) |
| Filtration Pressure Rating | ≥50 psi |
| Filter Disc Diameter | 142 mm (non-volatile) / 90 mm (volatile) |
| Filter Pore Size | 0.7 µm (glass fiber) / 0.5 µm (stainless steel) |
| Construction Materials | 316 stainless steel (filtration unit), borosilicate glass & PE & PTFE-compatible vessels |
| pH Adjustment | Manual in-situ capability |
| Safety | Overload protection, low-noise rotary drive, aluminum frame architecture |
| Compliance | Designed for EPA Method 1311 (TCLP), ASTM D5233, ISO 11372 |
| Brand | Environics |
|---|---|
| Origin | USA |
| Model | 4000 Series |
| Dilution Ratio | Up to 10,000:1 |
| Concentration Range | % to ppb |
| Flow Accuracy | ±1.0% of setpoint (concentration & flow) |
| Flow Repeatability | ±0.05% |
| Warm-up Time | 30 min |
| Gas Connection | 1/4" Swagelok® or compatible |
| Operating Pressure | 10–75 psig (0.67–5.04 bar) |
| UHP Leak Rate | ≤1×10⁻⁹ atm·cm³/sec He |
| Humidity Range (optional) | 0–95% RH (±5% accuracy, NIST-traceable) |
| Heating | Optional heated gas pathways (temperature-controlled) |
| Surface Treatment | Optional silanized stainless-steel tubing |
| Purge Pathway | Integrated electromagnetic valve purge system |
| Permeation Oven | Optional multi-zone permeation furnace with dual-permeation-tube capacity |
| Brand | Environics |
|---|---|
| Origin | USA |
| Model | 4040 |
| Dilution Ratio | Up to 10,000:1 |
| Flow Accuracy | ±1.0% of setpoint |
| Concentration Accuracy | ±1.0% of setpoint |
| Flow Repeatability | ±0.05% |
| Dimensions (Portable) | 43.18 cm × 17.78 cm × 38.1 cm |
| Weight | 8.2 kg (2-MFC), 10.4 kg (4-MFC), 15.9 kg (8-MFC) |
| Brand | Environics Oy |
|---|---|
| Origin | Finland |
| Model | S4000 / S4040 |
| Concentration Accuracy | ±1.0% of setpoint |
| Repeatability | ±1.0% |
| Max Operating Pressure | 75 psig (recommended: 25 psig) |
| Dilution Ratio | Up to 10,000:1 (S4040) |
| Gas Inputs | 4 (S4000) / 6 sample + 1 diluent (S4040) |
| Control Interface | RS-232, Windows-based software |
| Brand | MNK |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | VOC |
| Pricing | Available Upon Request |
| Brand | Environmental Express |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Heavy-Duty LE Rotator |
| Price Range | USD $13,500 – $40,500 (est.) |
| Rotation Speed | 30 rpm ±2 rpm |
| Time Control Range | 0–99 hours |
| Sample Bottle Capacity | 12 positions |
| Temperature Range | 0–99°C |
| Temperature Control Accuracy | ±1°C |
| Brand | Environmental Express |
|---|---|
| Origin | USA |
| Model | HotBlock® TKN Series |
| Temperature Range | Ambient to 450°C |
| Configurations | 28-position or 54-position |
| Heating Block Material | 316 Stainless Steel |
| Controller Type | Optional Advanced Touchscreen (up to 8 preloaded methods, 20-step programmable ramping) |
| Power Supply | 240 VAC, 50/60 Hz |
| Compliance | Designed for ASTM D5179, EPA 351.2, ISO 11905-1, and USP <467> residual nitrogen workflows |
| Sample Tube Compatibility | Standard threaded digestion tubes compatible with SimpleDist® distillation systems |
| Safety Design | Controller mounted externally to fume hood |
| Brand | PERIC |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | Customized Environmental Protection Concierge Service Integrated Platform |
| Pricing | Available Upon Request |
| Origin | Australia |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Environodour |
| Pricing | Available Upon Request |
| Origin | Canada |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MicroLAB/EcoLAB |
| Pricing | Upon Request |
| (在此处输出精准翻译� | �纯英文产品名称。极其重要:仅输出一行名称,严禁输出备选名、严禁换行重复、严禁包含任何中文字符) |
|---|---|
| [Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China-integrated, European-designed architecture) |
| Model | ENVIS |
| Pricing | Available upon Request] |