| Origin | France |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | EME Guard XS |
| Pricing | Upon Request |
| Origin | France |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | EME Spy 121/100 |
| Price | Upon Request |
| Frequency Range (Spy 121) | 88 MHz – 2.5 GHz |
| Frequency Range (Spy 100) | 88 MHz – 2.17 GHz |
| Electric Field Probe | Triaxial isotropic E-field sensor |
| Sensitivity (Spy 121) | 0.05 V/m (dynamic range up to 10 V/m, 46 dB) |
| Sensitivity (Spy 100) | 0.05 V/m (dynamic range up to 5 V/m, 40 dB) |
| Data Points (Spy 121) | 12,540 |
| Data Points (Spy 100) | 7,168 |
| Logging Interval | 4–255 seconds |
| Operating Temperature | −10 °C to +50 °C |
| Relative Humidity | ≤85 % RH (non-condensing) |
| Battery | Rechargeable Li-ion |
| Battery Life | >20 days (typical continuous logging at 30-sec interval) |
| Power Adapter | 100–240 VAC, 50–60 Hz |
| Charger Output | Max 0.9 A |
| Dimensions (H × L × W) | 193 × 95.6 × 69.4 mm |
| Weight | 450 g |
| Ingress Protection | IP50 |
| Compliance Reference | ICNIRP 2020 Guidelines for Human Exposure to Electromagnetic Fields |
| Origin | France |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | EME Spy 140 |
| Price | Upon Request |
| Brand | EMS |
|---|---|
| Origin | Czech Republic |
| Type | Portable Weather Station |
| Data Logger | Modular RailBox RB System (16-channel standard, up to 64-channel expandable) |
| Power Supply | Solar panel + rechargeable battery (6.5–15 VDC, standby <1 mA) |
| Communication | GPRS/LAN/4G (backward-compatible with EDGE/GPRS) |
| GPS | Integrated geolocation tagging |
| Internal Memory | 220,000 timestamped records (expandable to 450,000) |
| MicroSD Storage | 8 GB (2–3 years of continuous logging) |
| Operating Temperature | −40 °C to +60 °C |
| Compliance | DIN rail mounting, SDI-12 & analog sensor support, IP67-rated enclosures for field deployment |
| Brand | EMS |
|---|---|
| Origin | Czech Republic |
| Model | EMScloud RainSet |
| Weight | 2.2 kg |
| Operating Temperature | −40 to +60 °C |
| Rainfall Resolution | 0.2 mm |
| Collection Area | 200 cm² |
| Temperature Range | −40 to +60 °C |
| Relative Humidity Range | 0–100 %RH |
| Temperature Accuracy | ±0.15 °C |
| RH Accuracy | ±2 %RH |
| Measurement Interval | 5 min |
| Storage Interval | 30 min |
| Transmission Interval | 60 min (or 10 min during rainfall events) |
| Power Supply | 3.6 V / 3.6 Ah SAFT LS17500 Lithium Thionyl Chloride Battery |
| Communication | LTE-M/NB-IoT with embedded o-SIM |
| Ingress Protection | IP63 |
| Dimensions | 250 × 250 × 160 mm |
| Brand | EMTEK |
|---|---|
| Origin | USA |
| Model | P100 |
| Sampling Flow Rates | 28.3 L/min or 100 L/min |
| Dimensions | 19.05 cm (L) × 13.97 cm (W) × 15.24 cm (H) |
| Weight | <2.45 kg |
| Inlet Cap | 300-hole precision array |
| Exhaust Filtration | Integrated HEPA filter (optional remote exhaust tubing) |
| Display | Touch-enabled LCD screen |
| Battery Life | >12 hours at 28.3 L/min |
| Data Storage | 500 sample records |
| Communication | Infrared remote control (start/stop/pause/resume) |
| Housing Material | Kydex® with Microban® antimicrobial protection |
| Inlet & Base Material | Anodized aluminum |
| Optional Accessories | Rotational slit sampler head, standard impactor head, directional inlet cap for unidirectional airflow sampling, compressed air/gas inlet adapter, extended sampling tubes |
| Brand | EMTEK |
|---|---|
| Origin | USA |
| Model | P100 |
| Flow Rates | 28.3 L/min or 100 L/min (selectable) |
| Sampling Principle | Isokinetic Impaction |
| Dimensions | 19.05 × 13.97 × 15.24 cm |
| Weight | <2.45 kg |
| Inlet Orifice Count | 300 |
| Exhaust Filtration | HEPA-filtered (with optional remote exhaust tubing) |
| Display | Touch-enabled LCD |
| Battery Life | >12 h (at 28.3 L/min) |
| Data Storage | 500 sampling records |
| Remote Control | IR-based start/stop/pause/resume |
| Housing Material | Microban®-infused Kydex® |
| Sample Head Compatibility | Standard slit-impactor and rotating-slit™ heads |
| Maximum Sample Volume | 3000 L |
| Adjustable Agar Height | Yes |
| Compliance | Designed to meet ISO 14698-1, EU GMP Annex 1, and USP <1116> requirements for viable particle monitoring |
| Brand | EMTEK |
|---|---|
| Origin | USA |
| Model | P100SS |
| Sampling Principle | Impaction-based viable air sampling |
| Flow Rates | 28.3 L/min (1 CFM) or 100 L/min (switchable via dedicated inlet caps) |
| Maximum Sampling Duration & Volume | 120 min / 3396 L @ 28.3 L/min |
| Flow Accuracy | ±1.5% via electronic closed-loop mass flow control |
| Operating Temperature | 5–40 °C |
| Relative Humidity | 10–80% RH (non-condensing) |
| Power Input | 100–240 VAC, 50/60 Hz |
| DC Output | 18 V, 3.6 A |
| Dimensions | 20 × 9.5 × 9.5 cm |
| Weight | 3.3 kg |
| Data Storage | 1 MB for sampling runs, 512 KB flash for firmware, 128 KB RAM, 512 KB EEPROM for calibration |
| Connectivity | USB 1.1 client, 10/100Base-T Ethernet |
| Compliance | ISO 14698-1, EN 17141, EU GMP Annex 1, CE |
| Brand | EMTEK |
|---|---|
| Origin | USA |
| Model | EMTEK-V100 |
| Sampling Principle | Slit-to-Agar Rotation & Andersen-Style Impaction |
| Flow Rates | 28.3, 50, or 100 L/min (user-selectable) |
| Dimensions | 25.4 × 20.3 × 17.8 cm (L×W×H) |
| Weight | 2.45 kg |
| Power Input | 100–115 V / 60 Hz or 220 V / 50 Hz |
| Data Storage Capacity | >500 test records |
| Sampling Duration per Cycle | 0–120 min |
| Maximum Sample Volume per Cycle | >300 L |
| Exhaust Filter | 0.2 µm sterilizing-grade hydrophobic PTFE |
| Housing & Sampling Heads | Microban®-infused Kydex® and 316 stainless steel |
| Remote Control | Infrared (Start/Stop/Pause/Resume) |
| Display | Full-color touchscreen LCD |
| Optional Output | Thermal printer (label + receipt modes), USB data export |
| Origin | Fujian, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | Xiamen Lawlink |
| Price Range | USD 70,000 – 140,000 |
| Brand | Junfang Lihua |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GXH-1050E |
| Instrument Type | Online Process Analyzer |
| Detection Target | Multi-component Gases |
| Minimum Range | 0–50 ppm |
| Repeatability | ≤1% F.S. |
| Resolution | 0.1 ppm |
| Response Time | ≤60 s |
| Zero Drift | ≤±2% F.S./24 h |
| Span Drift | ≤±2% F.S./24 h |
| Linearity Error | ≤±1% F.S. |
| Power Supply | AC 220 V ±10%, 50 Hz ±5% |
| Output Signal | 4–20 mA analog + RS232 digital interface |
| Operating Humidity | ≤90% RH (non-condensing) |
| Warm-up Time | ≤60 min |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | AQM60 |
| Gas Detection Range | O₃ (0–150 ppb, 0–500 ppb), NO₂ (0–200 ppb), CO (0–100 ppm), Non-Methane VOCs (0–25 ppm), Toluene (0–500 ppm), SO₂ (0–10 ppm), H₂S (0–10 ppm), NH₃ (0–100 ppm), CO₂ (0–2000 ppm, NDIR), Halogenated Hydrocarbons (0–500 ppm) |
| Sampling Pump | Brushless DC motor-driven helical vane |
| Sample Line Material | PFA, PTFE, Kynar |
| Enclosure Rating | IP66 / NEMA 4 |
| Dimensions | 361 × 254 × 165 mm |
| Weight | <10 kg (sensor-integrated unit) |
| Power Supply | 24 VDC, 1 A |
| Communication | RS232 / RS485 (DB9 / M12 connectors) |
| Data Logging Interval | 2 minutes |
| Certifications | FCC Part 15, EN 61000-6-3:2001, EN 61000-6-1:2001, CE, FC |
| Brand | Guangming Chemical |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Models | 104SA, 104SB, 104U |
| Pricing | Upon Request |
| Origin | United Kingdom |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | PR2 |
| Pricing | Available Upon Request |
| Measurement Principle | Frequency Domain Reflectometry (FDR) |
| Sensor Count Options | 4-sensor (PR1/4) or 6-sensor (PR1/6) configurations |
| Depth Intervals | 10, 20, 30, 40 cm (PR1/4) |
| Volumetric Water Content Range | 0–1.0 m³·m⁻³ (0–100% vol.) |
| Sensor Accuracy | ±3% (post-calibration) |
| Sensor Repeatability | ±1% |
| Operating Temperature | −20 to +70 °C |
| Standard Cable Length | 2 m (extendable up to 100 m) |
| Probe Diameter | 28 mm |
| PR1/4 Dimensions | 637 mm L × 28 mm Ø, 0.55 kg |
| PR1/6 Dimensions | 1246 mm L × 28 mm Ø, 0.95 kg |
| HH2 Handheld Meter Resolution | 1 mV |
| HH2 Memory Capacity | 1100 readings |
| HH2 Battery Life | ~6500 readings |
| HH2 Display Units | m³·m⁻³, % vol., mm, mV |
| Brand | HUANKONG |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory-Based Volatile Phenol & Anionic Detergent Analyzer |
| Model | 3100 |
| Compliance Standards | GB/T 7494–1987, GB/T 5750.4–2006, HJ 503–2009 |
| Configuration | Fully Automated Benchtop System with Integrated Sample Handling, Extraction, Reaction, and Photometric Detection |
| Origin | Qingdao, Shandong, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | 3012H |
| Pricing | Available Upon Request |
| Sampling Principle | Isokinetic Sampling via Pitot Tube + Gravimetric Collection |
| Gas Detection Method | Potentiostatic Electrolysis |
| Operating Power | AC 220 V ±10%, 50 Hz or DC 12 V |
| Dimensions | 450 × 168 × 410 mm |
| Weight | ~10.0 kg |
| Noise Level | <65 dB(A) |
| Power Consumption | <180 W |
| Data Storage Capacity | >100,000 measurement records |
| Brand | WTW |
|---|---|
| Origin | Germany |
| Model | Multi 3510 IDS |
| Instrument Type | Portable / Handheld Water Quality Analyzer |
| Detection Principle | Electrochemical Sensing (pH, ORP, Conductivity, DO) & Optical Turbidity Measurement (Nephelometry) |
| Measured Parameters | pH, ORP, Dissolved Oxygen (DO), Oxygen Saturation (%), Partial Pressure of Oxygen (pO₂), Electrical Conductivity, Resistivity, Salinity, TDS, Turbidity (NTU/FNU) |
| Repeatability | <1% |
| Display | Graphical LCD |
| Data Storage | Up to 10,000 datasets (manual + automatic logging) |
| Protection Rating | IP67 |
| Power Supply | 4 × AA alkaline or 4 × 1.2 V NiMH rechargeable batteries |
| Interface | Micro-USB-B |
| Wireless Capability | Optional Bluetooth module for real-time probe telemetry |
| Probe Interface | Digital IDS (Intelligent Digital Sensor) interface with auto-recognition and embedded calibration memory |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Domestic Production | Yes |
| Model | MODEL2030 |
| Price | USD 3,950 (FOB) |
| Measurement Principle | Laser Backscatter Photometry |
| Explosion-Proof Rating | Ex d IIB T4 Gb |
| Measurement Range | 0.01–5000 mg/m³ (standard) |
| Resolution | 0.01 mg/m³ |
| Accuracy | ±1% of reading |
| Relative Error | ±2% FS |
| Operating Temperature | −40 °C to +65 °C |
| Humidity Range | 0–100% RH (non-condensing) |
| Max. Flue Gas Temperature | 300 °C (custom high-temp probe available) |
| Output Signal | 4–20 mA (max. load 500 Ω) |
| Power Supply | DC 16–24 V ±10% |
| Power Consumption | ≤3 W (typical), ≤5 W (max.) |
| Dimensions | 160 × 250 mm (H × D) |
| Weight | 4 kg |
| Flue Diameter Compatibility | 1–15 m |
| Minimum Detectable Concentration | 2 mg/m³ |
| Installation | Single-ended, tool-free mounting |
| Origin | Italy |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 8869 |
| Pricing | Available Upon Request |
| Measurement Principle | Non-Dispersive Infrared (NDIR) |
| Minimum Range | CO: 0–10 ppm, CO₂: 0–5 ppm |
| Certifications | CE, EN 50081-1, EN 50082-2 |
| Enclosure Rating | IP65 |
| Weight | ~32 kg |
| Power Supply | 220 VAC, 48–63 Hz, 35 W |
| Sample Pressure (Flexible Tubing) | 600–1500 hPa (absolute) |
| (Rigid Tubing) | 500–1500 hPa (absolute) |
| Purge Gas Pressure | <165 hPa (gauge), short-term >250 hPa (gauge) |
| Sample Flow Rate | 0.3–1.5 L/min |
| Sample Temperature | 0–50 °C (standard), 0–80 °C (with optional heater) |
| Sample Humidity | <90% RH |
| Warm-up Time | 2 hours |
| Response Time (T₉₀) | 5 s |
| Damping Time | 0–100 s adjustable |
| Dead Time | 0.5–2.5 s |
| Internal Signal Processing Time | <1 s |
| Output Stability | ±0.1% to ±1% of minimum range |
| Zero Drift | <1% of minimum range per month |
| Span Drift | <1% of full scale per month |
| Repeatability | 0.1–1% of full scale |
| Linearity Error | <0.5% FS |
| Analog Inputs | 2 × 0/2/4–20 mA (cross-interference compensation) |
| Digital Inputs | 6 × 24 V DC, floating |
| Relay Outputs | 6 × 24 V AC/DC, 1 A, floating |
| Communication Interface | RS-485 |
| Operating Ambient Temperature | 5–45 °C |
| Storage/Transport Temperature | −30–+70 °C |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | PM2.5 |
| Price Range | USD 14,000–21,000 |
| Measurement Principle | Laser Light Scattering |
| Measured Parameters | PM1.0, PM2.5, PM5, PM10, TSP |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | 1500A |
| Instrument Type | Laboratory Benchtop Analyzer |
| Power Supply | 220 V AC, 50 Hz |
| Optical Source | Laser Diode |
| Detection Principle | Laser Light Attenuation / Absorption |
| Particle Size Range | 2–400 µm |
| Number of Adjustable Size Channels | 8 |
| Minimum Detectable Size | 2 µm |
| Resolution | ≤9% @ 2 µm |
| Signal-to-Noise Ratio | 3:1 |
| Counting Efficiency | ≥50% @ 1 µm |
| Maximum Particle Concentration | 18,000 counts/mL |
| Coincidence Loss (at max concentration) | 10% |
| Flow Rate | 60 mL/min (controlled via overflow tube & hydraulic pressure) |
| Flow Accuracy | ≤2% |
| Sensor MTBF | 60,000–80,000 hours |
| Communication Interface | RS-485 (4-wire Modbus), optional 4–20 mA output |
| Baud Rate | 9600 bit/s |
| Data Modes | Cumulative or Time-Segmented |
| Maximum Display Value | 9,999,999 (cumulative count) |
| Sample Path Flushing | Semi-Automatic |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 740 |
| Pricing | Available Upon Request |
| Origin | United Kingdom |
|---|---|
| Distribution Model | Authorized Distributor |
| Import Status | Imported |
| Model | 715 |
| Pricing | Upon Request |
| Weight | 1.2 kg |
| Dimensions | 280 × 230 × 130 mm |
| Enclosure Rating | IP54 (main unit), IP68 (probe) |
| Cable Diameter | 5 mm |
| Standard Cable Length | 10 m (max. 15 m) |
| Operating Temperature | −20–60 °C (unit), 0–40 °C (probe) |
| Storage Temperature | −20–60 °C (unit), 0–40 °C (probe) |
| Power Supply | 9 V PP9 battery (typical lifespan: 3 months) |
| Response Time | 0.5 s |
| Interface Detection Accuracy | ±1 cm |
| Resolution | 1 cm (marked at 1 m intervals) |
| Measurement Principle | Near-infrared light scattering (960 nm) |
| Probe Options | IR100 (0–200 mg/L, 100 mm sensing gap), IR40 (0–1,500 mg/L, 40 mm), IR15 (0–10,000 mg/L, 15 mm), IR8 (0–30,000 mg/L, 8 mm) |
| Output | Audible tone (short in water, long in sludge), LED indicator, no analog/digital output |
| Brand | Not specified |
|---|---|
| Origin | South Korea |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | ECT400/D052 |
| Pricing | Upon Request |
| Frequency | 450 kHz (ECT400) / 50 kHz & 200 kHz dual-frequency (D052) / 30 kHz & 200 kHz dual-frequency (D032) |
| Beam Width | 5° (ECT400) / 27° & 7° (50/200 kHz, D052) / 26° & 5° (30/200 kHz, D032) |
| Depth Range | 0.15–100 m (standard), up to 1000 m (customizable) |
| Vertical Resolution | 1 mm |
| Temperature Sensor Accuracy | ±0.1 °C |
| Tilt Sensor | Optional dual-axis (roll & pitch), ±90° range, 0.1° resolution |
| Net Weight / Gross Weight | 275 g / 1.6 kg (ECT400), 460 g / 2.7 kg (D052), 740 g / 4.2 kg (D032) |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Domestic Production | Yes |
| Model | SQC-1000 |
| Pricing | Available Upon Request |
| Flow Range Options | 0.1–1.5 L/min, 0.1–2.0 L/min, or 0.1–3.0 L/min |
| Flow Accuracy | ≤ ±5% |
| Timing Accuracy | ≤ ±1% |
| Maximum Negative Pressure | ≥25 kPa |
| Power Supply | 10 V DC (rechargeable Ni-Cd battery) / 220 V AC, 50 Hz |
| Operating Temperature | –10 to +45 °C |
| Relative Humidity | ≤85% RH |
| Weight | ~2.0 kg |
| Brand | AMAE |
|---|---|
| Origin | Guangdong, China |
| Model | EM-2068E |
| Sampling Methods | Filter Gravimetry (TSP/PM₁₀/PM₂.₅), Absorption Solution Collection, Sorbent Tube Enrichment |
| Measured Parameters | TSP, PM₁₀, PM₂.₅, SO₂, NOₓ, VOCs, Halogenated Hydrocarbons, Aldehydes/Ketones |
| Particulate Flow Range | 10–120 L/min |
| Dual High-Flow Gas Channels | 100–1500 mL/min |
| Dual Low-Flow Gas Channels | 10–200 mL/min |
| Flow Stability | ±5% |
| Flow Resolution | 0.1 L/min (particulate), 1 mL/min (gas) |
| Power Supply | Internal Rechargeable DC Battery (6–8 h at nominal flow) |
| Weight | 4.5 kg (including thermoelectric temperature control module) |
| Brand | Vientiane Environment |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | WX-Q2 |
| Price | USD 12,300 (FOB) |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ENH-1000 |
| Price | USD 795 (FOB) |
| Measurement Range | 0–2000 ppb |
| Accuracy | ±5 ppb |
| Power Supply | DC 6 V (4 × AA batteries) |
| Dimensions | 40 mm (W) × 195 mm (H) × 40 mm (D) |
| Weight | 135 g |
| Electrode Protection Solution | Included (2 vials) |
| Accessories | Waterproof O-rings (2), Electrode Cleaning Paper, Carrying Case, User Manual |
| Brand | ENTECH |
|---|---|
| Model | CS1200E |
| Type | 24-Hour Constant-Flow, Ambient-Pressure Gas Samplers |
| Configuration | Single-Channel Passive Canister Sampling System |
| Flow Control | Sapphire Orifice + Precision Pressure Regulator |
| Calibration Traceability | NIST-Traceable McDaniel Controls Flow Meter |
| Surface Treatment | Electropolished Stainless Steel with Silonite™ Fused-Silica Coating (Optional, denoted by “S” suffix) |
| Operating Range | 1–168 hours (adjustable via interchangeable sapphire orifices) |
| Inlet Protection | Hydrophobic Cap with Particulate Filtration |
| Compliance | Designed for EPA TO-14A, TO-15, ASTM D5466, and ISO 16017-1 Compliant Sampling |
| Brand | Environ Lab |
|---|---|
| Origin | USA |
| Model | ENV-12 |
| Capacity | 12 sample vessels |
| Rotation Speed | 30 ± 2 rpm |
| Tumbling Angle | 30° ± 2° |
| Timer Range | 0.1–999.9 h |
| Vessel Volume | 1 L (standard HDPE or stainless-steel options) |
| Compliance | ASTM D3987, EPA Method 1311 (TCLP), EPA Method 1312 (SPLP), ISO 14669 |