- All
- Favorite
- Popular
- Most rated
| Brand | Eppendorf |
|---|---|
| Origin | Japan |
| Manufacturer | Hitachi High-Technologies Corporation (Himac) |
| Type | Floor-standing refrigerated ultracentrifuge |
| Speed Range | 300–30,000 rpm |
| Max RCF | 110,000 × g |
| Max Capacity | 6 × 1,000 mL or 4 × 1,500 mL |
| Noise Level | < 56 dBA |
| Dimensions (W×D×H) | 708 × 892 × 866 mm |
| Weight | 310 kg |
| Temperature Control Accuracy | ±2 °C |
| Refrigerant | R410A |
| Power Supply | AC 220 V, 50/60 Hz, 1500 W max |
| Interface | 1× USB, 1× LAN |
| Program Storage | 1,000 protocols |
| Timer Range | 1 s–9 min 59 s (1-s increment) or 1 min–99 h 59 min (1-min increment), with hold function |
| Acceleration Profiles | 11 modes |
| Deceleration Profiles | 10 modes (incl. 2 variable slope) |
| Safety Features | Interlocked door, overspeed detection, imbalance sensing, rotor lid detection, overtemperature protection |
| Sterilization Compatibility | Autoclavable rotors (121 °C, 20 min) for R30AT, R10A3, R5S4 |
| Drive System | Inverter-controlled induction motor |
| Cooling System | Variable-speed rotary compressor |
| Brand | Eppendorf |
|---|---|
| Origin | Germany |
| Manufacturer | Eppendorf AG |
| Type | Benchtop Refrigerated Centrifuge |
| Model | 5920 R |
| Maximum Speed | 14,000 rpm |
| Maximum RCF | 22,132 × g |
| Maximum Capacity | 4 × 1000 mL |
| Temperature Range | −11 °C to 40 °C |
| Dimensions (W × D × H) | 740 × 710 × 400 mm |
| Rotor Type | Horizontal (Swinging-Bucket) |
| Application Class | Biomolecular Separation |
| Compliance | IEC 61010-1, ISO 13485 (for medical device manufacturing), GLP/GMP-ready audit trail support via software |
| Brand | Eppendorf |
|---|---|
| Origin | Germany |
| Manufacturer | Eppendorf AG |
| Product Type | Benchtop Refrigerated Centrifuge |
| Model | 5425 R |
| Speed Range | 100–15,060 rpm |
| Max RCF | 21,300 × g |
| Max Capacity | 10 × 5 mL |
| Temperature Range | −10 °C to 40 °C |
| Noise Level | <54 dB(A) |
| Timer Range | 10 s – 9 h 59 min |
| Dimensions (W × D × H) | 29 × 48 × 26 cm |
| Rotor Compatibility | Universal with Eppendorf 5425 series |
| Sterilization | Autoclavable rotors (CAMR-certified airtight lids) |
| Cooling System | High-efficiency compressor with ECO standby mode |
| Key Features | FastTemp pre-cooling (21 °C → 4 °C in 8 min), SOFT brake, At set rpm timing, Short spin button, rpm/rcf toggle, condensate tray |
| Brand | Eppendorf |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | 5804/R |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | High-Speed (10,000–30,000 rpm) |
| Function | Refrigerated Centrifuge |
| Configuration | Horizontal Rotor Centrifuge |
| Separation Class | Cellular & Bacterial Pelletization |
| Maximum Capacity | 4 × 250 mL or 2 × 5 Microtiter Plates (MTP) |
| Maximum Speed | 14,000 rpm |
| Maximum RCF | 20,913 × g |
| Dimensions (W × D × H) | 64 × 55 × 34 cm |
| Brand | Eppendorf |
|---|---|
| Origin | Germany |
| Manufacturer | Eppendorf AG |
| Product Type | Benchtop Microcentrifuge |
| Model | MiniSpin / MiniSpin Plus |
| Centrifugation Range | High-Speed (up to 14,500 rpm) |
| Max Rotor Capacity | 12 × 1.5/2.0 mL tubes + 2 × PCR strips |
| Max Speed | 14,500 rpm |
| Max RCF | 14,100 × g |
| Acceleration/Deceleration Time | <13 s (0 ↔ max speed) |
| Dimensions (W × D × H) | 22.6 × 23.9 × 12.0 cm |
| Rotor Material | Anodized Aluminum |
| Cooling Mechanism | Passive Airflow Optimization (No Active Refrigeration) |
| Timer Range | 10 s – 99 min (MiniSpin Plus only) |
| Instant Spin Function | Dedicated “Short Spin” Button |
| Lid Operation | Soft-close mechanism with automatic lid opening post-run |
| Compliance | IEC 61010-1, EN 61326-1 (EMC), CE Marked for Laboratory Use |
| Brand | Eppendorf |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | 5427 R |
| Instrument Type | Benchtop Centrifuge |
| Feature Parameter | High-Speed Centrifuge (10,000–30,000 rpm) |
| Function | Refrigerated Centrifuge |
| Typical Configuration | Fixed-Angle Rotor Centrifuge |
| Maximum Capacity | 48 × 1.5/2.0 mL, 12 × 5 mL |
| Maximum Speed | 16,220 rpm |
| Maximum RCF | 25,001 × g |
| Dimensions | 31.9 × 54.0 × 25.4 cm |
| Noise Level | < 56 dB(A) |
| Acceleration/Deceleration Time | 18 s each |
| Timer Range | 5 s to 9 h 59 min, continuous operation enabled |
| Temperature Range | −11 °C to 40 °C |
| Refrigerant | R290 (propane) |
| Power Consumption | 495 W |
| Net Weight (without rotors) | 30 kg |
| Rotor Count | 9 |
| ECO Standby Options | 1, 2, 4, or 8 hours |
| Brand | Eppendorf |
|---|---|
| Origin | Japan |
| Manufacturer | Eppendorf |
| Product Type | Floor-standing centrifuge |
| Speed Class | Ultracentrifuge (>30,000 rpm) |
| Cooling | Refrigerated |
| Configuration | Horizontal rotor system |
| Separation Target | Large organelles / Viruses |
| Max Capacity | 8.0 L |
| Max Speed | 40,000 rpm |
| Max RCF | 118,000 × g |
| Dimensions (W×D×H) | 175 × 115 × 295 cm |
| Brand | Eppendorf |
|---|---|
| Origin | Japan |
| Manufacturer | Hitachi High-Technologies (Himac) |
| Type | Floor-standing refrigerated centrifuge |
| Max Speed | 22,000 rpm |
| Max RCF | 58,700 × g |
| Max Capacity | 4 × 1,500 mL |
| Dimensions | 700 × 760 × 915 mm |
| Weight | 260 kg |
| Refrigerant | R410A |
| Noise Level | 64 dB(A) |
| Power Supply | 220–240 V, 50/60 Hz, 3200 W max |
| Interface | USB port for operation log export |
| Safety Features | Auto rotor recognition, non-contact imbalance detection, lid interlock, overspeed protection, rotor cover detection, overtemperature monitoring |
| Acceleration/Deceleration | 9 programmable modes each |
| Programmable Methods | 30 user-defined protocols with RCF and g·sec calculation |
| Compliance | Designed to support GLP/GMP workflows |
| Brand | Eppendorf |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Product Category | Imported |
| Model | 5910 Ri |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | High-Speed Centrifuge (10,000–30,000 rpm) |
| Function | Refrigerated Centrifuge |
| Configuration | Swinging-Bucket Centrifuge |
| Separation Level | Cellular & Bacterial |
| Maximum Capacity | 6 × 250 mL |
| Maximum Speed | 14,000 rpm |
| Maximum RCF | 22,132 × g |
| Dimensions | 72 × 66 × 37 cm |
| Noise Level | 53 dB(A) |
| Temperature Range | –11 °C to 40 °C |
| Acceleration/Deceleration | 10 adjustable profiles |
| Power Requirement | 1650 W |
| Voltage/Frequency | 230 V, 50–60 Hz |
| Rotor Compatibility | Fully compatible with all 5910 R rotors |
| Brand | Eppendorf |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | 5810/R |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | Up to 14,000 rpm |
| Max RCF | 20,913 × g |
| Max Capacity | 4 × 750 mL or 4 × 4 MTP (Microtiter Plates) |
| Temperature Range (5810 R only) | –9 °C to 40 °C |
| Dimensions (W × D × H) | 70 × 61 × 35 cm |
| Rotor Recognition | Automatic |
| Imbalance Detection | Integrated |
| Noise Level | ≤ 59 dB(A) |
| QuickLock System | Yes |
| FastTemp Pre-cooling | Yes |
| ECO Standby Mode | Yes |
| Dynamic Compressor Control (DCC) | Yes |
| Brand | Eppendorf |
|---|---|
| Origin | Germany |
| Manufacturer | Eppendorf AG |
| Product Type | Benchtop Centrifuge |
| Model | 5430 / 5430 R |
| Speed Range | 10,000–17,500 rpm |
| Max RCF | 30,130 × g |
| Max Capacity | 48 × 1.5/2.0 mL |
| Dimensions | 33 × 42 × 25 cm |
| Temperature Range (5430 R only) | –11 °C to 40 °C |
| Refrigeration | Patented compressor-based cooling system with FastTemp pro pre-cooling and continuous post-run cooling |
| Compliance | IEC 61010-1, ISO 13485 (for medical device manufacturing environments), GLP-compliant data logging capability |
| Brand | Eppendorf |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Models | CP100NX / CP90NX / CP80NX |
| Instrument Type | Floor-standing Ultracentrifuge |
| Speed Class | >30,000 rpm |
| Function | Refrigerated Ultracentrifuge |
| Configuration | Fixed-angle Rotor System |
| Separation Target | Organelles, Viruses, Exosomes, Macromolecular Complexes |
| Max Capacity | 1,690 mL (P32ZT rotor) / 1,380 mL (P21A2 rotor) |
| Max Speed | 100,000 rpm (CP100NX), 90,000 rpm (CP90NX), 80,000 rpm (CP80NX) |
| Max RCF | 803,000 × g (CP100NX), 700,000 × g (CP90NX), 615,000 × g (CP80NX) |
| Dimensions | 790 × 690 × 880 mm |
| Noise Level | 51 dB(A) |
| Cooling System | CFC/HCFC/HFC-free Thermo-module |
| Temperature Control Accuracy | ±0.5 °C |
| Vacuum System | Rotary Oil Pump + Oil Diffusion Pump |
| Acceleration Modes | 10 |
| Deceleration Modes | 11 (including coast-down) |
| Brake System | Regenerative Braking with Energy Recovery |
| Display | 6.5" Color LCD Touchscreen |
| User Management | 3-Tier Access Control |
| Program Storage | Up to 1,000 Protocols |
| Interface | 2× USB (host/device), 1× LAN |
| Power Supply | AC 200–240 V, 50/60 Hz, ≤1,000 W |
| Weight | 390 kg |
| Brand | Eppendorf |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | 5425 |
| Instrument Type | Benchtop Centrifuge |
| Category | High-Speed Centrifuge (10,000–30,000 rpm) |
| Function | General-Purpose Centrifuge |
| Configuration | Fixed-Angle Rotor Centrifuge |
| Separation Class | Biomacromolecules |
| Maximum Capacity | 10 × 5.0 mL |
| Maximum Speed | 15,060 rpm |
| Maximum RCF | 21,330 × g |
| Dimensions | 24 × 39 × 24 cm |
| Acoustic Noise Level | < 51 dB(A) |
| Rotor Recognition | Yes (5.0 mL fixed-angle rotor, PCR swing-bucket rotor) |
| Acceleration/Deceleration Programs | 10-step selectable |
| Quick-Start Function | Short-spin mode with single-button activation |
| Lid Mechanism | Eppendorf QuickLock® fast-locking system |
| Lid Opening | Automatic post-run opening |
| Safety Certification | Third-party validated hermetic rotor sealing |
| Brand | Eppendorf |
|---|---|
| Origin | Japan |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | CS150NX / CS150FNX |
| Instrument Type | Floor-standing Ultracentrifuge |
| Feature Parameter | Ultrahigh-speed Centrifuge (>30,000 rpm) |
| Function | Refrigerated Centrifuge |
| Typical Configuration | Fixed-angle Rotor Centrifuge |
| Separation Level | Organelles / Viruses |
| Maximum Capacity | 6 × 30 mL |
| Maximum Speed | 150,000 rpm |
| Maximum RCF | 1,050,000 × g |
| Dimensions (CS150FNX) | 440 × 520 × 910 mm |
| Brand | Eppendorf |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | 5702 / 5702 R / 5702 RH |
| Instrument Type | Benchtop Centrifuge |
| Speed Class | Low-Speed Centrifuge (max. 4,400 rpm) |
| Functionality | Refrigerated Centrifuge (5702 R & 5702 RH) / Ambient-Temperature Centrifuge (5702) |
| Configuration | Fixed-Angle Rotor Centrifuge |
| Target Applications | Cell and Bacterial Pellet Separation |
| Maximum Capacity | 4 × 100 mL |
| Maximum Speed | 4,400 rpm |
| Maximum RCF | 3,000 × g |
| Dimensions (W × D × H) | 32 × 40 × 24 cm |
Show next