- All
- Favorite
- Popular
- Most rated
| Brand | New Brunswick |
|---|---|
| Origin | USA |
| Model | Innova 44/44 R |
| Instrument Type | Air-Jacketed Temperature-Controlled Orbital Shaker |
| Timer Range | Continuous Control |
| Oscillation Speed | 25–400 rpm |
| Orbit Diameter | 2.5 cm (1") and 5.1 cm (2") |
| Temperature Range | Innova 44: +5 °C above ambient to 80 °C |
| Innova 44 R | –20 °C below ambient to 80 °C (minimum 4 °C) |
| Number of Platforms | 1 |
| Brand | Eppendorf |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | DASGIP |
| Price Range | USD 25,000 – 65,000 (FOB Hamburg) |
| Temperature Control Range | 2–12 °C (external jacket cooling only |
| full bioreactor operating range | 20–55 °C with integrated heating/cooling) |
| Working Volume Range | 0.2–3.8 L per vessel |
| Vessel Configuration | 1, 3, or 4 parallel vessels |
| Gas Flow Control | Individual thermal mass flow controllers (MFCs) per vessel |
| Aeration Options | Ring sparger or microbubble diffuser |
| Agitation | Top-driven magnetic or mechanical stirrer (vessel-dependent) |
| pH Range | 2.0–12.0 (with standard electrodes) |
| Dissolved Oxygen (DO) Range | 0–200% air saturation |
| Sterilization Method | Autoclavable (121 °C, 20 min, 1.1 bar gauge) for glass vessels |
| Brand | Eppendorf |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Mastercycler X50 |
| Instrument Type | Gradient PCR Cycler |
| Sample Capacity | 96-well format |
| Heating Rate | 10 °C/s |
| Temperature Accuracy | ±0.15 °C |
| Inter-well Temperature Uniformity | <0.2 °C (at 20–72 °C), <0.3 °C (at 90 °C) |
| Network Capability | Up to 10 units daisy-chained locally |
| Thermal Lid | flexlid® automatic height-adjusting heated lid |
| Warranty | 2 years |
| Brand | Eppendorf |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Eppendorf Mastercycler® X40 Gradient PCR Cycler |
| Sample Capacity | 0.1 mL tubes, 0.2 mL tubes, 8-strip tubes, 96-well plates |
| Heating Rate | 3.3 °C/s |
| Temperature Accuracy | ±0.15 °C |
| Well-to-Well Uniformity | ±0.2 °C across 20–72 °C range |
| Gradient Range | 12-column linear gradient (max ΔT = 40 °C) |
| Dimensions (W × D × H) | 24.5 × 38.5 × 23 cm |
| Weight | 7.25 kg |
| Thermal Block Material | Anodized aluminum |
| Lid Temperature Control | SafeLid™ adaptive heated lid (up to 110 °C, pressure-adjustable) |
| Brand | Eppendorf |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported |
| Model | BioFlo 320 |
| Working Volume | 0.6 – 10.5 L |
| Total Volume | 2.5 – 14.0 L |
| Aeration System | 1, 3, or 4 thermal mass flow controllers |
| pH Control Range | 2.0 – 12.0 |
| Dissolved Oxygen (DO) Control Range | 0 – 200% air saturation |
| Temperature Control Range | 5°C (cooling fluid inlet) to 90°C |
| Brand | New Brunswick |
|---|---|
| Origin | USA |
| Model | NB Innova 40 R |
| Instrument Type | Refrigerated Temperature-Controlled Orbital Shaker |
| Timer Range | Continuous Operation |
| Oscillation Speed | 25–500 rpm |
| Orbit Diameter | 190 mm (standard), 250 mm (Innova 40 R) |
| Temperature Range | 5°C above ambient to 80°C |
| Platform | Single 46 × 46 cm stainless-steel shaker platform |
| Certifications | cETL, UL, CSA, CE |
| Sample Capacity | Up to three 3-L Erlenmeyer flasks simultaneously |
| Brand | Calibre |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | TransferMan 4r |
| Price Range | USD 13,500 – 40,500 (est. based on EUR/¥ conversion) |
| High-Voltage Range | Not applicable |
| Low-Voltage Range | Not applicable |
| Pulse Duration | Not applicable |
| Capacitance (µF) | Not applicable |
| Resistance | Not applicable |
| Brand | Calibre |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PiezoXpert |
| Pricing | Upon Request |
| Brand | Eppendorf |
|---|---|
| Origin | Germany |
| Manufacturer | Eppendorf AG |
| Type | Air-jacketed CO₂ incubated shaker |
| CO₂ Detection | Thermal Conductivity (TC) sensor |
| Temperature Range & Accuracy | +8 °C above ambient to 60 °C |
| CO₂ Concentration Range & Accuracy | 0.1–20% (±0.1% at 5% CO₂) |
| Humidity Control | Active dual-directional humidification, up to 85% rH, condensation-free operation |
| Chamber Capacity | 220 L |
| External Dimensions (W×D×H) | 77.3 × 131.8 × 80.5 cm |
| Brand | Eppendorf |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | CellXpert C170 |
| Temperature Range & Accuracy | +4 °C above ambient to 50 °C |
| Temperature Uniformity | ±0.25 °C at 37 °C |
| Humidity Range & Accuracy | 90–95 % RH at 37 °C |
| Chamber Capacity | 170 L |
| Brand | Eppendorf |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | DASbox Mini Bioreactor System |
| Temperature Range | 2–12 °C (external jacket control) |
| Working Volume Range | 0.06–0.25 L per vessel |
| Vessel Configuration | 1, 3, or 4 independent vessels |
| Gas Control | Four thermal mass flow controllers (MFCs) per vessel for air, O₂, CO₂, and N₂ |
| Sparging Options | Ring-type or microbubble spargers |
| pH/DO/Liquid Level Monitoring | Integrated electrochemical sensors with real-time feedback control |
| Sterilization Method | Autoclavable (121 °C, 20 min, saturated steam) |
| Agitation | Top-driven motor with interchangeable impellers (flat-blade, pitched-blade, marine propeller) |
| Cooling System | Water-free Peltier-based temperature regulation per vessel |
| Exhaust Condensation | Modular, tool-free, dry cold trap with one-click activation/deactivation |
| Feed Control | Peristaltic pumps with programmable speed and volumetric precision |
| Operational Modes | Batch, fed-batch, continuous, and perfusion culture |
| Brand | Eppendorf |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | CryoCube F101h |
| Effective Internal Volume | 101 L |
| Inner Dimensions (W × D) | 908 × 566 mm |
| External Dimensions (W × D) | 908 × 566 mm |
| Power Supply | 230 V / 50 Hz |
| Rated Power Consumption | 440 W |
| Brand | Eppendorf |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | BioFlo 120 |
| Vessel Total Volume | 2.5–14.0 L |
| Working Volume | 0.4–10.5 L |
| Aeration System | 1, 3, or 4 thermal mass flow controllers |
| pH Control Range | 2.0–12.0 |
| Dissolved Oxygen (DO) Control Range | 0–200% air saturation |
| Temperature Control Range | 5°C (cooling fluid inlet) to 90°C |
| Brand | Eppendorf |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | CellXpert C170i |
| Temperature Range & Accuracy | +4 °C above ambient to 50 °C |
| Temperature Uniformity | ±0.25 °C at 37 °C |
| Humidity Control Range & Accuracy | 90–95 % RH at 37 °C |
| Chamber Capacity | 170 L |
| Sterilization Mode | 180 °C dry-heat sterilization |
| Heating Method | Fanless, six-sided direct heating |
| Interface | Full-color capacitive touchscreen with audit trail-capable data logging |
| Brand | Eppendorf |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Mastercycler nexus X2 |
| Instrument Type | Gradient PCR Thermal Cycler |
| Sample Capacity | 96-well plate, 8-tube strip |
| Heating Rate | ≈ 3 °C/s |
| Temperature Accuracy | ±0.2 °C |
| Well-to-Well Temperature Uniformity | ≤ ±0.3 °C (20–72 °C) |
| Brand | Eppendorf |
|---|---|
| Country of Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | ThermoMixer C |
| Instrument Category | Orbital Shaker / Temperature-Controlled Mixer |
| Timer Range | 15 s – 99 h 30 min |
| Mixing Speed | 300 – 3000 rpm |
| Orbit Diameter | 3 mm |
| Temperature Range | 15 °C below ambient to 100 °C |
| Number of Available SmartBlock Modules | 11 |
| Brand | Eppendorf |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | BioBLU |
| Volume Range | 380 mL – 50 L |
| Aeration System | 1, 3, or 4 thermal mass flow controllers |
| pH Control Range | 2–12 |
| Dissolved Oxygen (DO) Control Range | 0–200% air saturation |
| Temperature Control Range | 5°C above coolant temperature to 60°C (via heating blanket) |
| Brand | Eppendorf |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | CellXpert C170i |
| Temperature Range & Accuracy | 4–50 °C |
| Temperature Uniformity | ±0.3 °C |
| Humidity Range & Accuracy | 90–95 %RH |
| Chamber Capacity | 170 L |
| Brand | Eppendorf |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | 5073t |
| Instrument Type | Magnetic Bead-Based Purification System |
| Throughput | 24 samples per run |
| Sample Volume Range | < 300 µL |
| Typical Run Time per Batch | < 2 hours |
| Brand | Eppendorf |
|---|---|
| Origin | Germany |
| Manufacturer | Eppendorf AG |
| Type | Imported |
| Model | CryoCube F440 |
| Configuration | Upright |
| Effective Volume | 440 L |
| Internal Dimensions | Not specified (standardized for 2" cryobox compatibility) |
| External Dimensions | 955 × 898 × 1960 mm (W × D × H) |
| Power Supply | 230 V, 50 Hz |
| Rated Power Consumption | 8300 W |
| Temperature Range | −50 °C to −86 °C |
| Refrigeration System | Two-stage cascade with R290/R170 eco-friendly refrigerants |
| Insulation | Polyurethane foam (F440n) or polyurethane + vacuum insulation panels (Vacupor NT, F440h) |
| Door Design | 5-compartment layout with 5 insulated inner doors |
| Wall Thickness | 130 mm |
| Vacuum Release Port | Integrated automatic pressure equalization valve |
| Brand | Eppendorf |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | MixMate |
| Instrument Category | Compact Vortex Mixer / Microplate Shaker |
| Timer Range | 15 s – 99 h 30 min |
| Oscillation Frequency | 300–3000 rpm |
| Orbit Diameter | 3 mm |
| Platform Configuration | Triple interchangeable platforms |
| Brand | Calibre |
|---|---|
| Origin | Germany |
| Model | Eporator |
| Voltage Presets | P1 = 1700 V, P2 = 2500 V |
| Display | Color LCD Interface |
| Safety | Integrated Electrode Slot with Leakage Protection |
| Compliance | GLP-Compliant Data Logging via USB |
| Dimensions | Compact Benchtop Form Factor |
| Regulatory Status | Import-Class Life Science Instrument for Transfection and Cell Fusion Applications |
| Brand | Eppendorf |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported |
| Model | CryoCube F570 |
| Form Factor | Upright |
| Effective Volume | 570 L |
| Interior Dimensions (mm) | 765 × 575 × 1265 |
| External Dimensions (mm) | 1025 × 852 × 1940 |
| Power Supply | 230 V, 50 Hz |
| Rated Power Consumption | 438 W |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ThermoStat C |
| Pricing | Available Upon Request |
Show next